Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 12 de 12
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Synchrotron Radiat ; 29(Pt 5): 1284-1291, 2022 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-36073888

RESUMO

The development, construction, and first commissioning results of a new scanning microscope installed at the 5-ID Submicron Resolution X-ray Spectroscopy (SRX) beamline at NSLS-II are reported. The developed system utilizes Kirkpatrick-Baez mirrors for X-ray focusing. The instrument is designed to enable spectromicroscopy measurements in 2D and 3D with sub-200 nm spatial resolution. The present paper focuses on the design aspects, optical considerations, and specifics of the sample scanning stage, summarizing some of the initial commissioning results.

2.
J Synchrotron Radiat ; 26(Pt 4): 1316-1321, 2019 Jul 01.
Artigo em Inglês | MEDLINE | ID: mdl-31274460

RESUMO

The factors limiting the performance of alternative polycrystalline solar cells as compared with their single-crystal counterparts are not fully understood, but are thought to originate from structural and chemical heterogeneities at various length scales. Here, it is demonstrated that multimodal focused nanobeam X-ray microscopy can be used to reveal multiple aspects of the problem in a single measurement by mapping chemical makeup, lattice structure and charge collection efficiency simultaneously in a working solar cell. This approach was applied to micrometre-sized individual grains in a Cu(In,Ga)Se2 polycrystalline film packaged in a working device. It was found that, near grain boundaries, collection efficiency is increased, and that in these regions the lattice parameter of the material is expanded. These observations are discussed in terms of possible physical models and future experiments.

3.
J Synchrotron Radiat ; 24(Pt 6): 1113-1119, 2017 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-29091054

RESUMO

A hard X-ray scanning microscope installed at the Hard X-ray Nanoprobe beamline of the National Synchrotron Light Source II has been designed, constructed and commissioned. The microscope relies on a compact, high stiffness, low heat dissipation approach and utilizes two types of nanofocusing optics. It is capable of imaging with ∼15 nm × 15 nm spatial resolution using multilayer Laue lenses and 25 nm × 26 nm resolution using zone plates. Fluorescence, diffraction, absorption, differential phase contrast, ptychography and tomography are available as experimental techniques. The microscope is also equipped with a temperature regulation system which allows the temperature of a sample to be varied in the range between 90 K and 1000 K. The constructed instrument is open for general users and offers its capabilities to the material science, battery research and bioscience communities.

4.
J Synchrotron Radiat ; 22(2): 336-41, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25723934

RESUMO

Hard X-ray microscopy is a prominent tool suitable for nanoscale-resolution non-destructive imaging of various materials used in different areas of science and technology. With an ongoing effort to push the 2D/3D imaging resolution down to 10 nm in the hard X-ray regime, both the fabrication of nano-focusing optics and the stability of the microscope using those optics become extremely challenging. In this work a microscopy system designed and constructed to accommodate multilayer Laue lenses as nanofocusing optics is presented. The developed apparatus has been thoroughly characterized in terms of resolution and stability followed by imaging experiments at a synchrotron facility. Drift rates of ∼2 nm h(-1) accompanied by 13 nm × 33 nm imaging resolution at 11.8 keV are reported.

5.
Rev Sci Instrum ; 85(3): 033707, 2014 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-24689592

RESUMO

We have designed and constructed a dedicated instrument to perform ptychography measurements and characterization of multilayer Laue lenses nanofocusing optics. The design of the scanning microscope provides stability of components and minimal thermal drifts, requirements for nanometer scale spatial resolution measurements. We performed thorough laboratory characterization of the instrument in terms of resolution and thermal drifts with subsequent measurements at a synchrotron. We have successfully acquired and reconstructed ptychography data yielding 11 nm line focus.

6.
Rev Sci Instrum ; 84(3): 035006, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23556845

RESUMO

We have constructed a compact prototype apparatus for active correction of circle of confusion during rotational motion. Our system combines fiber optic interferometry as a sensing element, the reference cylinder along with the nanopositioning system, and a robust correction algorithm. We demonstrate dynamic correction of run-out errors down to 40 nm; the resolution is limited by ambient environment and accuracy of correcting nanopositioners. Our approach provides a compact solution for in-vacuum scanning nanotomography x-ray experiments with a potential to reach sub-nm level of correction.

7.
Rev Sci Instrum ; 84(3): 033701, 2013 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-23556821

RESUMO

Synchrotron based x-ray microscopy established itself as a prominent tool for noninvasive investigations in many areas of science and technology. Many facilities around the world routinely achieve sub-micrometer resolution with a few instruments capable of imaging with the spatial resolution better than 100 nm. With an ongoing effort to push the 2D/3D resolution down to 10 nm in the hard x-ray regime both fabrication of the nano-focusing optics and stability of a microscope become extremely challenging. In this work we present our approach to overcome technical challenges on the path towards high spatial resolution hard x-ray microscopy and demonstrate the performance of a scanning fluorescence microscope equipped with the multilayer Laue lenses focusing optics.

9.
Rev Sci Instrum ; 80(8): 083704, 2009 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-19725659

RESUMO

We have developed the variable temperature scanning force microscope capable of performing both magnetic resonance force microscopy (MRFM) and magnetic force microscopy (MFM) measurements in the temperature range between 5 and 300 K. Modular design, large scanning area, and interferometric detection of the cantilever deflection make it a sensitive, easy to operate, and reliable instrument suitable for studies of the dynamic and static magnetization in various systems. We have verified the performance of the microscope by imaging vortices in a Nb thin film in the MFM mode of operation. MRFM spectra in a diphenyl-picryl-hydrazyl film were recorded to evaluate the MRFM mode of operation.

10.
Phys Rev Lett ; 100(19): 197601, 2008 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-18518486

RESUMO

We report nanoscale scanned probe ferromagnetic resonance force microscopy (FMRFM) imaging of individual ferromagnetic microstructures. This reveals the mechanism for high spatial resolution in FMRFM imaging: the strongly inhomogeneous local magnetic field of the cantilever mounted micromagnetic probe magnet used in FMRFM enables selective, local excitation of ferromagnetic resonance (FMR). This approach, demonstrated here in individual permalloy disks, is straightforwardly extended to excitation of localized FMR modes, and hence imaging in extended films.

11.
Phys Rev Lett ; 90(19): 195301, 2003 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-12785952

RESUMO

We report the first observation of longitudinal sound propagation in three dimensionally distributed Bose and Fermi superfluids in an acoustic investigation of phase separated 3He-4He mixtures confined to aerogel. At mK temperatures, this inhomogeneous system exhibits simultaneous 3He and 4He superfluidity leading to two "slow modes" along with the conventional sound mode. We also infer the superfluidity of isolated bubbles of pure 3He in a large 4He concentration sample.

12.
Phys Rev Lett ; 92(24): 245502, 2004 Jun 18.
Artigo em Inglês | MEDLINE | ID: mdl-15245094

RESUMO

We report on the mechanical behavior of an a-SiO2 84 kHz torsional oscillator operated between 100> or =T> or =1.0 mK. Below 10 mK we observed well-differentiated transient responses which we attribute to the interaction with low-level background radiation (gamma quanta and cosmic ray micro) and which can be modeled in terms of a change in the spring constant.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA