Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 102
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Eur Heart J ; 44(15): 1331-1339, 2023 04 17.
Artigo em Inglês | MEDLINE | ID: mdl-36883599

RESUMO

AIMS: Paravalvular regurgitation (PVR) after transcatheter aortic valve implantation (TAVI) is associated with increased morbidity and mortality. The effect of transcatheter interventions to treat PVR after the index TAVI was investigated. METHODS AND RESULTS: A registry of consecutive patients who underwent transcatheter intervention for ≥ moderate PVR after the index TAVI at 22 centers. The principal outcomes were residual aortic regurgitation (AR) and mortality at 1 year after PVR treatment. A total of 201 patients were identified: 87 (43%) underwent redo-TAVI, 79 (39%) plug closure, and 35 (18%) balloon valvuloplasty. Median TAVI-to-re-intervention time was 207 (35; 765) days. The failed valve was self-expanding in 129 (63.9%) patients. The most frequent devices utilized were a Sapien 3 valve for redo-TAVI (55, 64%), an AVP II as plug (33, 42%), and a True balloon for valvuloplasty (20, 56%). At 30 days, AR ≥ moderate persisted in 33 (17.4%) patients: 8 (9.9%) after redo-TAVI, 18 (25.9%) after plug, and 7 (21.9%) after valvuloplasty (P = 0.036). Overall mortality was 10 (5.0%) at 30 days and 29 (14.4%) at 1 year: 0, 8 (10.1%), and 2 (5.7%) at 30 days (P = 0.010) and 11 (12.6%), 14 (17.7%), and 4 (11.4%) at 1 year (P = 0.418), after redo-TAVI, plug, and valvuloplasty, respectively. Regardless of treatment strategy, patients in whom AR was reduced to ≤ mild had lower mortality at 1 year compared with those with AR persisting ≥ moderate [11 (8.0%) vs. 6 (21.4%); P = 0.007]. CONCLUSION: This study describes the efficacy of transcatheter treatments for PVR after TAVI. Patients in whom PVR was successfully reduced had better prognosis. The selection of patients and the optimal PVR treatment modality require further investigation.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/métodos , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Prognóstico , Resultado do Tratamento , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia
2.
Catheter Cardiovasc Interv ; 102(2): 328-338, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37393603

RESUMO

BACKGROUND: Valve-in-valve (VIV) transcatheter aortic valve implantation (TAVI) is a less invasive therapeutic option compared with redo surgical valve replacement for high-risk patients. Relative to procedures within stented surgical valves, VIV-TAVI within stentless valves is associated with a higher complication rate due to challenging underlying anatomy and absence of fluoroscopic landmarks. AIMS: We share a single-center experience with VIV-TAVI in stentless valves, discussing our procedural insights and associated outcomes. METHODS: Our institutional database was queried, and 25 patients who had undergone VIV-TAVI within a stentless bioprosthesis, homograft, or valve-sparing aortic root replacement between 2013 and 2022 were found. Outcome endpoints were based on the Valve Academic Research Consortium-3 criteria. RESULTS: The mean age of the cohort was 69.5 ± 13.6 years. VIV implantation was performed within a homograft in 11 patients, a stentless bioprothesis in 10 patients, and a valve-sparing aortic root replacement in 4 patients. Nineteen (76%) balloon-expandable valves, 5 (20%) self-expanding valves, and one mechanically-expandable (4%) valve were implanted with 100% procedural success, with no instances of significant paravalvular leak, coronary occlusion, or device embolization. There was one (4%) in-hospitality mortality after an emergency procedure; one (4%) patient experienced a transient ischemic attack; and two (8%) patients required permanent pacemaker implantation. The median length of hospital stay was 2 days. After a median follow-up time of 16.5 months, valve function was acceptable in all patients with available data. CONCLUSION: VIV-TAVI within stentless valves can be safely performed with methodical procedural technique and can provide clinical benefit in patients at high reoperation risk.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Resultado do Tratamento , Desenho de Prótese , Estenose da Valva Aórtica/cirurgia
3.
Pharmacogenomics J ; 22(5-6): 303-307, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35449399

RESUMO

Loss-of-function CYP2C19 variants are associated with increased cumulative ischemic outcomes warranting CYP2C19 genotyping prior to clopidogrel administration. TAILOR-PCI was an international, multicenter (40 sites), prospective, randomized trial comparing rapid point of care (POC) genotype-guided vs. conventional anti-platelet therapy. The performance of buccal-based rapid CYP2C19 genotyping performed by non-laboratory-trained staff in TAILOR-PCI was assessed. Pre-trial training and evaluation involved rapid genotyping of 373 oral samples, with 99.5% (371/373) concordance with Sanger sequencing. During TAILOR-PCI, 5302 patients undergoing PCI were randomized to POC rapid CYP2C19 *2, *3, and *17 genotyping versus no genotyping. At 12 months post-PCI, TaqMan genotyping determined 99.1% (2,364/2,385) concordance with the POC results, with 90.7-98.8% sensitivity and 99.2-99.6% specificity. In conclusion, non-laboratory personnel can be successfully trained for on-site instrument operation and POC rapid genotyping with analytical accuracy and precision across multiple international centers, thereby supporting POC genotyping in patient-care settings, such as the cardiac catheterization laboratory.Clinical Trial Registration: https://www.clinicalTrials.gov (Identifier: NCT01742117).


Assuntos
Intervenção Coronária Percutânea , Humanos , Citocromo P-450 CYP2C19/genética , Inibidores da Agregação Plaquetária/uso terapêutico , Sistemas Automatizados de Assistência Junto ao Leito , Estudos Prospectivos , Genótipo , Ensaios Clínicos Controlados Aleatórios como Assunto , Estudos Multicêntricos como Assunto
4.
Catheter Cardiovasc Interv ; 99(4): 1206-1213, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-35084101

RESUMO

To highlight the trends of surgical (open) aortic valve replacement (SAVR) as well as to compare the outcome between transcatheter aortic valve replacement (TAVR) and SAVR in elderly dialysis patients. TAVR has evolved as an effective alternative to surgery (SAVR) for aortic stenosis. We identified dialysis-dependent patients who underwent SAVR or TAVR from 2000 to 2015 from the United States Renal Data System using ICD-9 codes. We defined high-risk surgical patients as age over 70 or older. The primary endpoint was survival at 3 years and we compared the outcome between SAVR and TAVR groups using inverse probability of treatment weighting (IPTW). A total of 4332 and 1280 dialysis patients underwent SAVR and TAVR, respectively, during the study period. Among SAVR cohort, 3312 patients underwent SAVR before June 2012 and 1020 after June 2012. In-hospital mortality was significantly worse before 2012 (14.6% vs. 11.3% after 2012, p = 0.007) as well as estimated 3-year mortality (69.1% vs. 60.3% after 2012, p < 0.001). After June 2012, the TAVR cohort was older and had more comorbidities including coronary artery disease and congestive heart failure compared to the SAVR cohort. After IPTW, in-hospital mortality was significantly lower after TAVR versus SAVR (odds ratio 0.38 [95% confidence interval [CI], 0.27-0.52], p < 0.001). However, TAVR had a significantly higher risk of 3-year mortality than SAVR (hazard ratio 1.24 [95% CI 1.1-1.39], p < 0.001). TAVR may be a reasonable and potentially preferable alternative to SAVR in the elderly dialysis population in the short-term period.


Assuntos
Estenose da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Estenose da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Diálise Renal/efeitos adversos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Estados Unidos/epidemiologia
5.
Catheter Cardiovasc Interv ; 99(7): 2028-2037, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-35419936

RESUMO

OBJECTIVES: The purpose of the current study was to use intravascular ultrasound (IVUS) to clarify anatomical and morphological lesion characteristics of uncrossable lesions. BACKGROUND: Uncrossable lesions are not always severely calcified. The prevalence of uncrossable lesions that are nonseverely calcified as well as other mechanisms for uncrossability has not been well clarified. METHODS: A total of 252 de novo uncrossable lesions in native coronary arteries that underwent either rotational or orbital atherectomy due to inability of any balloon to cross the lesion and 38 lesions with severe calcium in which IVUS crossed preatherectomy were included. Severe calcium is defined as maximum arc of calcium ≥270°. RESULTS: Severe calcification was absent in 16% of uncrossable lesions, 83% of which had a significant vessel bend. Compared with crossable lesions with severe calcium, uncrossable lesions with severe calcium more often had a bend in the vessel (71% vs. 21%, p < 0.001) and a longer length of continuous severe calcium (median length of calcium ≥270° 3.8 mm vs. 1.9 mm, p = 0.001). Other than severe calcium (especially long continuous calcium) or a bend in the vessel, anatomical factors associated with uncrossabilty were aorto-ostial lesion location and small vessels. CONCLUSIONS: Uncrossable lesions are not always severely calcified. The interaction of lesion morphology (continuous long and large arcs of calcium) and vessel geometry (bend in the vessel or ostial lesion location) affect lesion crossability.


Assuntos
Aterectomia Coronária , Doença da Artéria Coronariana , Calcificação Vascular , Aterectomia Coronária/efeitos adversos , Cálcio , Angiografia Coronária , Doença da Artéria Coronariana/diagnóstico por imagem , Humanos , Resultado do Tratamento , Ultrassonografia de Intervenção , Calcificação Vascular/diagnóstico por imagem
6.
Catheter Cardiovasc Interv ; 97(2): 201-205, 2021 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-32415916

RESUMO

BACKGROUND: The healthcare burden posed by the coronavirus disease 2019 (COVID-19) pandemic in the New York Metropolitan area has necessitated the postponement of elective procedures resulting in a marked reduction in cardiac catheterization laboratory (CCL) volumes with a potential to impact interventional cardiology (IC) fellowship training. METHODS: We conducted a web-based survey sent electronically to 21 Accreditation Council for Graduate Medical Education accredited IC fellowship program directors (PDs) and their respective fellows. RESULTS: Fourteen programs (67%) responded to the survey and all acknowledged a significant decrease in CCL procedural volumes. More than half of the PDs reported part of their CCL being converted to inpatient units and IC fellows being redeployed to COVID-19 related duties. More than two-thirds of PDs believed that the COVID-19 pandemic would have a moderate (57%) or severe (14%) adverse impact on IC fellowship training, and 21% of the PDs expected their current fellows' average percutaneous coronary intervention (PCI) volume to be below 250. Of 25 IC fellow respondents, 95% expressed concern that the pandemic would have a moderate (72%) or severe (24%) adverse impact on their fellowship training, and nearly one-fourth of fellows reported performing fewer than 250 PCIs as of March 1st. Finally, roughly one-third of PDs and IC fellows felt that there should be consideration of an extension of fellowship training or a period of early career mentorship after fellowship. CONCLUSIONS: The COVID-19 pandemic has caused a significant reduction in CCL procedural volumes that is impacting IC fellowship training in the NY metropolitan area. These results should inform professional societies and accreditation bodies to offer tailored opportunities for remediation of affected trainees.


Assuntos
COVID-19/epidemiologia , Cateterismo Cardíaco , Cardiologia/educação , Educação de Pós-Graduação em Medicina/organização & administração , Bolsas de Estudo/organização & administração , Intervenção Coronária Percutânea/educação , Acreditação , Humanos , New Jersey , Cidade de Nova Iorque , Diretores Médicos , Inquéritos e Questionários
7.
Catheter Cardiovasc Interv ; 95(5): 1051-1056, 2020 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-31478304

RESUMO

OBJECTIVES: This multicenter retrospective study of the initial U.S. experience evaluated the safety and efficacy of temporary cardiac pacing with the Tempo® Temporary Pacing Lead. BACKGROUND: Despite increasing use of temporary cardiac pacing with the rapid growth of structural heart procedures, temporary pacing leads have not significantly improved. The Tempo lead is a new temporary pacing lead with a soft tip intended to minimize the risk of perforation and a novel active fixation mechanism designed to enhance lead stability. METHODS: Data from 269 consecutive structural heart procedures were collected. Outcomes included device safety (absence of clinically significant cardiac perforation, new pericardial effusion, or sustained ventricular arrhythmia) and efficacy (clinically acceptable pacing thresholds with successful pace capture throughout the index procedure). Postprocedure practices and sustained lead performance were also analyzed. RESULTS: The Tempo lead was successfully positioned in the right ventricle and achieved pacing in 264 of 269 patients (98.1%). Two patients (0.8%) experienced loss of pace capture. Procedural mean pace capture threshold (PCT) was 0.7 ± 0.8 mA. There were no clinically significant perforations, pericardial effusions, or sustained device-related arrhythmias. The Tempo lead was left in place postprocedure in 189 patients (71.6%) for mean duration of 43.3 ± 0.7 hr (range 2.5-221.3 hr) with final PCT of 0.84 ± 1.04 mA (n = 80). Of these patients, 84.1% mobilized out of bed with no lead dislodgment. CONCLUSION: The Tempo lead is safe and effective for temporary cardiac pacing for structural heart procedures, provides stable peri and postprocedural pacing and allows mobilization of patients who require temporary pacing leads.


Assuntos
Estimulação Cardíaca Artificial , Procedimentos Cirúrgicos Cardíacos , Marca-Passo Artificial , Assistência Perioperatória/instrumentação , Idoso , Idoso de 80 Anos ou mais , Estimulação Cardíaca Artificial/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Desenho de Equipamento , Feminino , Frequência Cardíaca , Humanos , Masculino , Segurança do Paciente , Assistência Perioperatória/efeitos adversos , Sistema de Registros , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Função Ventricular Direita
8.
Eur Heart J ; 40(27): 2218-2227, 2019 07 14.
Artigo em Inglês | MEDLINE | ID: mdl-31505615

RESUMO

AIMS: Transcatheter aortic valve replacement (TAVR) is now an established therapy for intermediate-risk surgical candidates with symptomatic, severe aortic stenosis. The clinical impact of new-onset left bundle branch block (LBBB) after TAVR remains controversial and has not been studied in intermediate-risk patients. We therefore sought to analyse outcomes associated with new LBBB in a large cohort of intermediate-risk patients treated with TAVR. METHODS AND RESULTS: A total of 2043 patients underwent TAVR in the PARTNER II trial and S3 intermediate-risk registry and survived to hospital discharge. Patients were excluded from the current analysis due to baseline conduction disturbances, pre-existing permanent pacemaker (PPM), and new PPM during the index hospitalization. Clinical outcomes at 2 years were compared between patients with and without persistent, new-onset LBBB at hospital discharge, and multivariable analysis was performed to identify predictors of mortality. Among 1179 intermediate-risk patients, new-onset LBBB at discharge occurred in 179 patients (15.2%). Patients with new LBBB were similar to those without except for more frequent diabetes and more frequent treatment with SAPIEN 3 vs. SAPIEN XT. At 2 years, new LBBB was associated with increased rates of all-cause mortality (19.3% vs. 10.8%, P = 0.002), cardiovascular mortality (16.2% vs. 6.5%, P < 0.001), rehospitalization, and new PPM implantation. By multivariable analysis, new LBBB remained an independent predictor of 2-year all-cause [hazard ratio (HR) 1.98, 95% confidence interval (95% CI) 1.33, 2.96; P < 0.001] and cardiovascular (HR 2.66 95% CI 1.67, 4.24; P < 0.001) mortality. New LBBB was also associated with worse left ventricular systolic function at 1 and 2-year follow-up. CONCLUSIONS: In a large cohort of intermediate-risk patients from the PARTNER II trial and registry, persistent, new-onset LBBB occurred in 15.2% of patients without baseline conduction disturbances or pacemaker. New LBBB was associated with adverse clinical outcomes at 2 years, including all-cause and cardiovascular mortality, rehospitalization, new pacemaker implantation, and worsened left ventricular systolic function. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov #NCT01314313 and NCT03222128.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bloqueio de Ramo/etiologia , Complicações Pós-Operatórias/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Humanos , Masculino , Medição de Risco , Resultado do Tratamento
9.
Catheter Cardiovasc Interv ; 93(6): 1048-1056, 2019 05 01.
Artigo em Inglês | MEDLINE | ID: mdl-30489684

RESUMO

OBJECTIVES: We sought to determine the 1-year outcomes of patients receiving successful chronic total occlusion (CTO) percutaneous coronary intervention (PCI) procedures comparing subintimal versus intraplaque wire tracking patterns. BACKGROUND: CTO PCI utilizes both intraluminal and subintimal wire tracking to achieve successful percutaneous revascularization. Intravascular ultrasound (IVUS) can be used to precisely determine the path of wire tracking. METHODS: From 2014 to 2016, data from patients undergoing CTO PCI were collected in a single-center database. The primary composite endpoint was target vessel failure (TVF) defined as cardiovascular death, target vessel myocardial infarction (MI), or target vessel revascularization (TVR). RESULTS: In total 157 patients with successful CTO PCI and concomitant IVUS imaging completed 1-year follow-up. Subintimal tracking was detected in 53.5% of cases and those patients had a higher incidence of prior PCI, prior coronary artery bypass grafting, and higher J-CTO score. At 1-year, the unadjusted rate of TVF in the subintimal tracking group was higher than the intraplaque group (17.9 vs. 6.9%, HR 2.74, 95% CI 1.00-7.54, P = 0.04), driven by numerically higher rates of TVR and peri-procedural MI. After multivariable adjustment, no significant differences in the rates of the TVF between subintimal vs. intraplaque groups were present at 1-year (TVF: HR 1.51, 95% CI 0.38-6.00, P = 0.55). Landmark analysis excluding in-hospital events showed no significant differences in TVF to 1-year. CONCLUSIONS: IVUS-detected subintimal tracking was observed in over half of successful CTO PCI cases and correlated with baseline and angiographic factors that contributed to the overall rate of TVF at 1-year.


Assuntos
Angioplastia Coronária com Balão , Oclusão Coronária/terapia , Vasos Coronários/diagnóstico por imagem , Placa Aterosclerótica , Ultrassonografia de Intervenção , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Doença Crônica , Angiografia Coronária , Oclusão Coronária/diagnóstico por imagem , Oclusão Coronária/mortalidade , Oclusão Coronária/fisiopatologia , Vasos Coronários/fisiopatologia , Bases de Dados Factuais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Valor Preditivo dos Testes , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
10.
Pacing Clin Electrophysiol ; 42(5): 542-547, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30829416

RESUMO

BACKGROUND: Leadless pacemakers (LPMs) have been shown to have lower postoperative complications than traditional permanent pacemakers but there have been no studies on the outcomes of LPMs in patients with transcatheter heart valve replacements (THVRs). This study determined outcomes of LPMs compared to transvenous single-chamber pacemakers (SCPs) post-THVR. METHODS: This is a retrospective single-center study including 10 patients who received LPMs post-THVR between February 2017 and August 2018 and a comparison group of 23 patients who received SCP post-THVR between July 2008 and August 2018. LPM or SCP was implanted at the discretion of electrophysiologists for atrial fibrillation with slow ventricular response or sinus node dysfunction with need for single-chamber pacing only. RESULTS: LPMs were associated with decreased tricuspid regurgitation (P = 0.04) and decreased blood loss during implantation (7.5 ± 2.5 cc for LPMs vs 16.8 ± 3.2 cc for SCPs, P = 0.03). Five LPM patients had devices positioned in the right ventricular septum as seen on transthoracic echocardiogram. Frequency of ventricular pacing was similar between LPM and SCP groups. In the LPM group, one case was complicated by a pseudoaneurysm and one death was due to noncardiac causes. There was one pneumothorax and one pocket infection in the SCP group. CONCLUSIONS: In this small retrospective study, LPMs were feasible post-THVR and found to perform as well as SCPs, had less intraprocedural blood loss, and were associated with less tricuspid regurgitation. Further, larger studies are required to follow longer-term outcomes and complications.


Assuntos
Estimulação Cardíaca Artificial/métodos , Procedimentos Cirúrgicos Cardíacos , Marca-Passo Artificial , Complicações Pós-Operatórias/prevenção & controle , Substituição da Valva Aórtica Transcateter , Insuficiência da Valva Tricúspide/prevenção & controle , Idoso de 80 Anos ou mais , Ecocardiografia , Feminino , Humanos , Masculino , Desenho de Prótese , Estudos Retrospectivos
11.
J Interv Cardiol ; 31(5): 543-552, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-30225907

RESUMO

This article is a continuation of our previously published annual reviews of transcatheter aortic valve replacement (TAVR). In 2017, TAVR further established a foothold in the management of intermediate risk patients with the publication of SURTAVI trial. Randomized trials also addressed the use of cerebral protection during TAVR and single versus dual antiplatelet therapy after TAVR. Newer generation valve systems continued to be studied for their efficacy and safety. This paper summarizes the major studies published in 2017.


Assuntos
Estenose da Valva Aórtica , Complicações Pós-Operatórias/prevenção & controle , Substituição da Valva Aórtica Transcateter , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Humanos , Prognóstico , Risco Ajustado , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/instrumentação , Substituição da Valva Aórtica Transcateter/métodos
12.
Lancet ; 388(10060): 2618-2628, 2016 11 26.
Artigo em Inglês | MEDLINE | ID: mdl-27806900

RESUMO

BACKGROUND: Percutaneous coronary intervention (PCI) is most commonly guided by angiography alone. Intravascular ultrasound (IVUS) guidance has been shown to reduce major adverse cardiovascular events (MACE) after PCI, principally by resulting in a larger postprocedure lumen than with angiographic guidance. Optical coherence tomography (OCT) provides higher resolution imaging than does IVUS, although findings from some studies suggest that it might lead to smaller luminal diameters after stent implantation. We sought to establish whether or not a novel OCT-based stent sizing strategy would result in a minimum stent area similar to or better than that achieved with IVUS guidance and better than that achieved with angiography guidance alone. METHODS: In this randomised controlled trial, we recruited patients aged 18 years or older undergoing PCI from 29 hospitals in eight countries. Eligible patients had one or more target lesions located in a native coronary artery with a visually estimated reference vessel diameter of 2·25-3·50 mm and a length of less than 40 mm. We excluded patients with left main or ostial right coronary artery stenoses, bypass graft stenoses, chronic total occlusions, planned two-stent bifurcations, and in-stent restenosis. Participants were randomly assigned (1:1:1; with use of an interactive web-based system in block sizes of three, stratified by site) to OCT guidance, IVUS guidance, or angiography-guided stent implantation. We did OCT-guided PCI using a specific protocol to establish stent length, diameter, and expansion according to reference segment external elastic lamina measurements. All patients underwent final OCT imaging (operators in the IVUS and angiography groups were masked to the OCT images). The primary efficacy endpoint was post-PCI minimum stent area, measured by OCT at a masked independent core laboratory at completion of enrolment, in all randomly allocated participants who had primary outcome data. The primary safety endpoint was procedural MACE. We tested non-inferiority of OCT guidance to IVUS guidance (with a non-inferiority margin of 1·0 mm2), superiority of OCT guidance to angiography guidance, and superiority of OCT guidance to IVUS guidance, in a hierarchical manner. This trial is registered with ClinicalTrials.gov, number NCT02471586. FINDINGS: Between May 13, 2015, and April 5, 2016, we randomly allocated 450 patients (158 [35%] to OCT, 146 [32%] to IVUS, and 146 [32%] to angiography), with 415 final OCT acquisitions analysed for the primary endpoint (140 [34%] in the OCT group, 135 [33%] in the IVUS group, and 140 [34%] in the angiography group). The final median minimum stent area was 5·79 mm2 (IQR 4·54-7·34) with OCT guidance, 5·89 mm2 (4·67-7·80) with IVUS guidance, and 5·49 mm2 (4·39-6·59) with angiography guidance. OCT guidance was non-inferior to IVUS guidance (one-sided 97·5% lower CI -0·70 mm2; p=0·001), but not superior (p=0·42). OCT guidance was also not superior to angiography guidance (p=0·12). We noted procedural MACE in four (3%) of 158 patients in the OCT group, one (1%) of 146 in the IVUS group, and one (1%) of 146 in the angiography group (OCT vs IVUS p=0·37; OCT vs angiography p=0·37). INTERPRETATION: OCT-guided PCI using a specific reference segment external elastic lamina-based stent optimisation strategy was safe and resulted in similar minimum stent area to that of IVUS-guided PCI. These data warrant a large-scale randomised trial to establish whether or not OCT guidance results in superior clinical outcomes to angiography guidance. FUNDING: St Jude Medical.


Assuntos
Angiografia Coronária/métodos , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Tomografia de Coerência Óptica , Ultrassonografia de Intervenção/métodos , Idoso , Vasos Coronários/patologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/métodos , Resultado do Tratamento
13.
Am Heart J ; 182: 80-88, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27914503

RESUMO

BACKGROUND: Coexistence of moderate aortic stenosis (AS) in patients with heart failure (HF) with reduced ejection fraction is not uncommon. Moderate AS increases afterload, whereas pharmacologic reduction of afterload is a pillar of contemporary HF management. HYPOTHESIS: Unloading the left ventricle by reducing the transaortic gradient with transfemoral transcatheter aortic valve replacement (TAVR) may improve clinical outcomes in patients with moderate AS and HF with reduced ejection fraction. STUDY DESIGN: The TAVR UNLOAD (NCT02661451) is an international, multicenter, randomized, open-label, clinical trial comparing the efficacy and safety of TAVR with the Edwards SAPIEN 3 Transcatheter Heart Valve in addition to optimal heart failure therapy (OHFT) vs OHFT alone in patients with moderate AS (defined by a mean transaortic gradient ≥20 mm Hg and <40 mm Hg, and an aortic valve area >1.0 cm2 and ≤1.5 cm2 at rest or after dobutamine stress echocardiography) and reduced ejection fraction. A total of 600 patients will be randomized in a 1:1 fashion. Clinical follow-up is scheduled at 1, 6, and 12 months, and 2 years after randomization. The primary end point is the hierarchical occurrence of all-cause death, disabling stroke, hospitalizations related to HF, symptomatic aortic valve disease or nondisabling stroke, and the change in the Kansas City Cardiomyopathy Questionnaire at 1 year. Secondary end points capture effects on clinical outcome, biomarkers, echocardiographic parameters, and quality of life. SUMMARY: The TAVR UNLOAD trial aims to test the hypothesis that TAVR on top of OHFT improves clinical outcomes in patients with moderate AS and HF with reduced ejection fraction.


Assuntos
Estenose da Valva Aórtica , Insuficiência Cardíaca , Substituição da Valva Aórtica Transcateter , Idoso , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/cirurgia , Cateterismo Cardíaco/métodos , Ecocardiografia sob Estresse/métodos , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/cirurgia , Humanos , Masculino , Avaliação de Processos e Resultados em Cuidados de Saúde , Índice de Gravidade de Doença , Volume Sistólico , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos
14.
Eur Heart J ; 35(24): 1599-607, 2014 Jun 21.
Artigo em Inglês | MEDLINE | ID: mdl-24179072

RESUMO

AIMS: Cardiac conduction disturbances, including a left bundle branch block (LBBB), occur frequently following transcatheter aortic valve replacement (TAVR) and may be associated with adverse clinical events. This analysis examines the incidence and implications of new onset, persistent LBBB in patients undergoing TAVR with a balloon-expandable valve. METHODS AND RESULTS: Patients undergoing TAVR in the Placement of Aortic Transcatheter Valves (PARTNER) trial and continued access registries with baseline and discharge/7-day electrocardiograms were included. Prior permanent pacemaker implantation (PPI) and baseline intraventricular conduction abnormalities were exclusion criteria. Predictors of new LBBB were identified and outcomes compared between patients with and without new LBBB. New LBBB occurred in 121 of 1151 (10.5%) patients and persisted in more than half at 6 months to 1 year. The only predictor of new LBBB was prior coronary artery bypass grafting. New LBBB was not associated with significant differences in 1-year mortality, cardiovascular mortality, repeat hospitalization, stroke, or myocardial infarction. However, it was associated with increased PPI during hospitalization (8.3 vs 2.8%, P = 0.005) and from discharge to 1 year (4.7 vs. 1.5%, P = 0.01). The ejection fraction failed to improve after TAVR in patients with new LBBB and remained lower at 6 months to 1 year (52.8 vs. 58.1%, P < 0.001). CONCLUSION: Persistent, new-onset LBBB occurred in 10.5% of patients without intraventricular baseline conduction who underwent TAVR in the PARTNER experience. New LBBB was not associated with death, repeat hospitalization, stroke, or myocardial infarction at 1 year, but was associated with a higher rate of PPI and failure of left ventricular ejection fraction to improve.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bioprótese/efeitos adversos , Bloqueio de Ramo/etiologia , Próteses Valvulares Cardíacas/efeitos adversos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso de 80 Anos ou mais , Valva Aórtica , Estenose da Valva Aórtica/fisiopatologia , Ecocardiografia , Eletrocardiografia , Feminino , Humanos , Masculino , Prognóstico , Volume Sistólico/fisiologia , Resultado do Tratamento
15.
Am Heart J ; 167(1): 43-50, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24332141

RESUMO

BACKGROUND: Tirofiban and eptifibatide are both small-molecule, competitive glycoprotein IIb/IIIa receptor inhibitors (GPIs) that are guideline-supported for upstream therapy in acute coronary syndromes (ACS). This study sought to compare the efficacy and safety of tirofiban and eptifibatide in patients with ACS. METHODS: Within the ACUITY trial, 4,323 patients with moderate- and high-risk ACS received upstream, adjunctive GPI (tirofiban or eptifibatide) in addition to an antithrombin. Primary outcomes included 30-day rates of composite major adverse cardiac events (MACE), major bleeding (not related to coronary artery bypass grafting), and composite net adverse clinical events (NACE). The outcomes were compared based on the upstream GPI administered. RESULTS: There were significant differences in the baseline characteristics of patients treated with tirofiban vs eptifibatide, particularly related to country/region. In unadjusted analyses, treatment with upstream tirofiban vs eptifibatide was associated with similar rates of major bleeding (5.8% vs 6.5%, P = .39) and nonsignificantly lower rates of MACE (6.1% vs 7.6%, P = .06) and NACE (10.6% vs 12.6%, P = .06). After propensity-based multivariable adjustment, there were no significant differences between tirofiban and eptifibatide with respect to 30-day major bleeding, MACE, or NACE. CONCLUSIONS: Among more than 4,000 patients with moderate- and high-risk ACS treated with upstream GPI as part of an early invasive management strategy, the use of tirofiban and eptifibatide resulted in similar clinical outcomes. These data suggest equivalence of these 2 agents for upstream use, while highlighting some of the difficulties of nonrandomized comparative effectiveness analyses, specifically the difficulty in addressing geographic differences in the use of nonrandomized treatments.


Assuntos
Síndrome Coronariana Aguda/tratamento farmacológico , Peptídeos/uso terapêutico , Inibidores da Agregação Plaquetária/uso terapêutico , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/antagonistas & inibidores , Tirosina/análogos & derivados , Idoso , Pesquisa Comparativa da Efetividade , Angiografia Coronária , Eptifibatida , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Pontuação de Propensão , Tirofibana , Resultado do Tratamento , Tirosina/uso terapêutico
16.
Eur Heart J Case Rep ; 8(8): ytae261, 2024 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-39113778

RESUMO

Background: Limited data exist on strain changes after transcatheter aortic valve implantation (TAVI) in patients with aortic regurgitation (AR). Case summary: Three patients with AR undergoing TAVI showed an initial reduction in global longitudinal strain (GLS), followed by sustained GLS improvement within the first year. Discussion: Findings align with those of surgically treated patients with AR. There is a possible superiority of GLS to left ventricular end-diastolic diameter ratio in assessing patients with severe volume overload.

17.
Artigo em Inglês | MEDLINE | ID: mdl-39066744

RESUMO

BACKGROUND: New postprocessing software facilitates 3-dimensional (3D) echocardiographic determination of mitral annular (MA) and neo-left ventricular outflow tract (neo-LVOT) dimensions in patients undergoing transcatheter mitral valve replacement (TMVR). OBJECTIVES: This study aims to test the accuracy of 3D echocardiographic analysis as compared to baseline computed tomography (CT). METHODS: A total of 105 consecutive patients who underwent TMVR at 2 tertiary care centers between October 2017 and May 2023 were retrospectively included. A virtual valve was projected in both baseline CT and 3D transesophageal echocardiography (TEE) using dedicated software. MA dimensions were measured in baseline images and neo-LVOT dimensions were measured in baseline and postprocedural images. All measurements were compared to baseline CT as a reference. The predicted neo-LVOT area was correlated with postprocedural peak LVOT gradients. RESULTS: There was no significant bias in baseline neo-LVOT prediction between both imaging modalities. TEE significantly underestimated MA area, perimeter, and medial-lateral dimension compared to CT. Both modalities significantly underestimated the actual neo-LVOT area (mean bias pre/post TEE: 25.6 mm2, limit of agreement: -92.2 mm2 to 143.3 mm2; P < 0.001; mean bias pre/post CT: 28.3 mm2, limit of agreement: -65.8 mm2 to 122.4 mm2; P = 0.046), driven by neo-LVOT underestimation in the group treated with dedicated mitral valve bioprosthesis. Both CT- and TEE-predicted-neo-LVOT areas exhibited an inverse correlation with postprocedural LVOT gradients (r2 = 0.481; P < 0.001 for TEE and r2 = 0.401; P < 0.001 for CT). CONCLUSIONS: TEE-derived analysis provides comparable results with CT-derived metrics in predicting the neo-LVOT area and peak gradient after TMVR.

18.
J Am Coll Cardiol ; 84(8): 712-722, 2024 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-39142725

RESUMO

BACKGROUND: Acute brain infarction detected by diffusion-weighted magnetic resonance imaging (DW-MRI) is common after transcatheter aortic valve replacement (TAVR), but its clinical relevance is uncertain. OBJECTIVES: The authors investigated the relationship between DW-MRI total lesion number (TLN), individual lesion volume (ILV), and total lesion volume (TLV) and clinical stroke outcomes after TAVR. METHODS: Patient-level data were pooled from 4 prospective TAVR embolic protection studies, with consistent predischarge DW-MRI acquisition and core laboratory analysis. C-statistic was used to determine the best DW-MRI measure associated with clinical stroke. RESULTS: A total of 495 of 603 patients undergoing TAVR completed the predischarge DW-MRI. At 30 days, the rate of clinical ischemic stroke was 6.9%. Acute ischemic brain injury was seen in 85% of patients with 5.5 ± 7.3 discrete lesions per patient, mean ILV of 78.2 ± 257.1 mm3, and mean TLV of 555 ± 1,039 mm3. The C-statistic was 0.84 for TLV, 0.81 for number of lesions, and 0.82 for maximum ILV in predicting ischemic stroke. On the basis of the TLV cutpoint as defined by receiver operating characteristic (ROC), patients with a TLV >500 mm3 (vs TLV ≤500 mm3) had more ischemic stroke (18.2% vs 2.3%; P < 0.0001), more disabling strokes (8.8% vs 0.9%; P < 0.0001), and less complete stroke recovery (44% vs 62.5%; P = 0.001) at 30 days. CONCLUSIONS: Our study confirms that the number, size, and total volume of acute brain infarction defined by DW-MRI are each associated with clinical ischemic strokes, disabling strokes, and worse stroke recovery in patients undergoing TAVR and may have value as surrogate outcomes in stroke prevention trials. (A Prospective, Randomized Evaluation of the TriGuard™ HDH Embolic Deflection Device During TAVI [DEFLECT III]; NCT02070731) (A Study to Evaluate the Neuro-embolic Consequences of TAVR [NeuroTAVR]; NCT02073864) (The REFLECT Trial: Cerebral Protection to Reduce Cerebral Embolic Lesions After Transcatheter Aortic Valve Implantation [REFLECT I]; NCT02536196) (The REFLECT Trial: Cerebral Protection to Reduce Cerebral Embolic Lesions After Transcatheter Aortic Valve Implantation [REFLECT II]; NCT02536196).


Assuntos
Imagem de Difusão por Ressonância Magnética , Substituição da Valva Aórtica Transcateter , Humanos , Imagem de Difusão por Ressonância Magnética/métodos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Masculino , Feminino , Idoso de 80 Anos ou mais , Idoso , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estudos Prospectivos , Complicações Pós-Operatórias/diagnóstico por imagem , Complicações Pós-Operatórias/etiologia , AVC Isquêmico/etiologia , AVC Isquêmico/diagnóstico por imagem , Relevância Clínica
19.
J Soc Cardiovasc Angiogr Interv ; 3(1): 101066, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-39131970

RESUMO

Background: Lack of standardization in posttranscatheter aortic valve replacement (TAVR) conduction disturbance (CD) identification and treatment may affect permanent pacemaker implantation (PPI) rates and clinical outcomes. The safety and efficacy of a standardized TAVR CD algorithm has not been analyzed. This study analyzes the Optimize PRO post-TAVR CD management algorithm with Evolut PRO/PRO+ valves. Methods: Optimize PRO is a prospective, postmarket study implementing 2 strategies to reduce pacemaker rates: TAVR with cusp overlap technique and a post-TAVR CD algorithm. The 2-hour postprocedural electrocardiogram (ECG) stratified patients to early discharge in the absence of new ECG changes or to CD algorithms for (1) ECG changes with preexisting right or left bundle branch block (LBBB), interventricular conduction delay or first-degree atrioventricular block, (2) new LBBB, or (3) high-degree atrioventricular block (HAVB). Results: The interim analysis of the CD cohort consisted of 125/400 TAVR recipients. In the CD cohort, the 30-day new PPI rate was higher (28.1% vs 1.5%; P <.001), and 60 (48%) patients were discharged with a 30-day continuous ECG monitor. At 30 days, 90% of patients discharged with a monitor did not require PPI. Clinical outcomes, including mortality, stroke, bleeding, and reintervention, were similar in patients with and without CDs. No patient experienced sudden cardiac death. Conclusions: Effective management of CDs using a standard algorithm following Evolut TAVR provides similar 30-day safety outcomes to patients without CDs who undergo routine next day discharge. The CD algorithm may provide an effective strategy to recognize arrhythmias early, improve PPI utilization, and facilitate safe monitoring of patients after discharge.

20.
JACC Cardiovasc Interv ; 17(11): 1325-1336, 2024 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-38866455

RESUMO

BACKGROUND: Conduction disturbances requiring a permanent pacemaker (PPM) are a frequent complication of transcatheter aortic valve replacement (TAVR) with few reports of rates, predictors, and long-term clinical outcomes following implantation of the third-generation, balloon-expandable SAPIEN 3 (S3) transcatheter heart valve (THV). OBJECTIVES: The aim of this study was to investigate the rates, predictors, and long-term clinical outcomes of PPM implantation following TAVR with the S3 THV. METHODS: The current study included 857 patients in the PARTNER 2 S3 registries with intermediate and high surgical risk without prior PPM, and investigated predictors and 5-year clinical outcomes of new PPM implanted within 30 days of TAVR. RESULTS: Among 857 patients, 107 patients (12.5%) received a new PPM within 30 days after TAVR. By multivariable analysis, predictors of PPM included increased age, pre-existing right bundle branch block, larger THV size, greater THV oversizing, moderate or severe annulus calcification, and implantation depth >6 mm. At 5 years (median follow-up 1,682.0 days [min 2.0 days, max 2,283.0 days]), new PPM was not associated with increased rates of all-cause mortality (Adj HR: 1.20; 95% CI: 0.85-1.70; P = 0.30) or repeat hospitalization (Adj HR: 1.22; 95% CI: 0.67-2.21; P = 0.52). Patients with new PPM had a decline in left ventricular ejection fraction at 1 year that persisted at 5 years (55.1 ± 2.55 vs 60.4 ± 0.65; P = 0.02). CONCLUSIONS: PPM was required in 12.5% of patients without prior PPM who underwent TAVR with a SAPIEN 3 valve in the PARTNER 2 S3 registries and was not associated with worse clinical outcomes, including mortality, at 5 years. Modifiable factors that may reduce the PPM rate include bioprosthetic valve oversizing, prosthesis size, and implantation depth.


Assuntos
Estenose da Valva Aórtica , Valva Aórtica , Estimulação Cardíaca Artificial , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Desenho de Prótese , Sistema de Registros , Substituição da Valva Aórtica Transcateter , Humanos , Masculino , Feminino , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Substituição da Valva Aórtica Transcateter/instrumentação , Fatores de Risco , Idoso , Fatores de Tempo , Idoso de 80 Anos ou mais , Resultado do Tratamento , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/mortalidade , Valva Aórtica/cirurgia , Valva Aórtica/fisiopatologia , Valva Aórtica/diagnóstico por imagem , Medição de Risco , Arritmias Cardíacas/terapia , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/mortalidade , Estados Unidos/epidemiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA