Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 43
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Pediatr ; 272: 114122, 2024 May 28.
Artigo em Inglês | MEDLINE | ID: mdl-38815742

RESUMO

OBJECTIVE: To test the hypothesis that neonates with symptomatic tetralogy of Fallot (TOF) and absent ductus arteriosus (ADA) have worse clinical outcomes compared with those with a ductus arteriosus (DA), and that this difference is driven by those born with ADA and with critically deficient pulmonary blood flow (CDPBF). STUDY DESIGN: We performed a retrospective, multicenter cohort study of neonates who underwent intervention for symptomatic TOF comparing death and reintervention between subjects with and without a DA identified on fetal echocardiogram or on echocardiogram performed in the first postnatal day. Exclusion criteria were as follows: inability to define DA status, collaterals supplying pulmonary blood flow, atrioventricular septal defect, and absent pulmonary valve. We defined CDPBF as undergoing a procedure to augment pulmonary blood flow on the date of birth or extracorporeal membrane oxygenation prior to such a procedure. RESULTS: The study cohort included 519 patients, among whom 11% had ADA. Patients with ADA were more likely to have a genetic syndrome and had smaller branch pulmonary artery size. In analyses adjusting for center, interventional treatment strategy, genetic syndrome, and minimum branch pulmonary artery size, ADA was associated with higher mortality risk (adjusted hazard ratio of 2.37 (95% CI: 1.07,5.27; P = .034). Seven patients had CDPBF (1.3% of the entire cohort and 12% of patients with ADA). CONCLUSIONS: A minority of symptomatic TOF neonates have ADA, which is associated with higher adjusted mortality risk compared with those with a DA. CDPBF appears to be a rare but important entity in this population.

2.
J Pediatr ; 250: 22-28.e4, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35772511

RESUMO

OBJECTIVE: To evaluate early growth following primary or staged repair of neonatal symptomatic tetralogy of Fallot (sTOF). STUDY DESIGN: We performed a retrospective, multicenter cohort study of consecutive infants with sTOF who underwent initial intervention at age ≤30 days, from 2005 to 2017. Management strategies were either primary repair or staged repair (ie, initial palliation followed by complete repair). The primary outcome was change in weight-for-age z-score (ΔWAZ) from the initial intervention to age 6 ± 2 months. Secondary outcomes included method and mode of feeding, feeding-related medications, and feeding-related readmissions. Propensity score adjustment was used to account for baseline differences between groups. A secondary analysis was performed comparing patients stratified by the presence of adequate growth (6-month ΔWAZ > -0.5) or inadequate growth (6-month ΔWAZ ≤ -0.5), independent of treatment strategy. RESULTS: The study cohort included 143 primary repair subjects and 240 staged repair subjects. Prematurity was more common in the staged repair group. After adjustment, median ΔWAZ did not differ between treatment groups over the first 6 months of life (primary: -0.43 [IQR, -1.17 to 0.50]; staged: -0.31 [IQR, -1.31 to 0.71]; P = .55). For the entire cohort, ΔWAZ was negative (-0.36; IQR, -1.21 to 0.63). There were no between-group differences in the secondary outcomes. Secondary analysis revealed that the subjects with adequate growth were more likely to be orally fed at initial hospital discharge (P = .04). CONCLUSIONS: In neonates with sTOF, growth trajectory over the first 6 months of life was substandard, irrespective of treatment strategy. Those patients with adequate growth were more likely to be discharged from the index procedure on oral feeds.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Tetralogia de Fallot , Humanos , Lactente , Recém-Nascido , Tetralogia de Fallot/cirurgia , Estudos Retrospectivos , Estudos de Coortes , Resultado do Tratamento , Procedimentos Cirúrgicos Cardíacos/métodos
3.
Pediatr Cardiol ; 43(7): 1587-1598, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-35381860

RESUMO

Neonates with symptomatic tetralogy of Fallot (sTOF) may undergo palliations with varying physiology, namely systemic to pulmonary artery connections (SPC) or right ventricular outflow tract interventions (RVOTI). A comparison of palliative strategies based on the physiology created is lacking. Consecutive sTOF neonates undergoing SPC or RVOTI from 2005-2017 were reviewed from the Congenital Cardiac Research Collaborative. The primary outcome was survival with successful complete repair (CR) by 18 months. A variety of secondary outcomes were assessed including overall survival, hospitalization-related comorbidities, and interstage reinterventions. Propensity score adjustment was utilized to compare treatment strategies. The cohort included 252 SPC (surgical shunt = 226, ductus arteriosus stent = 26) and 68 RVOTI (balloon pulmonary valvuloplasty = 48, RVOT stent = 11, RVOT patch = 9) patients. Genetic syndrome (29 [42.6%] v 75 [29.8%], p = 0.04), weight < 2.5 kg (28 [41.2%] v 68 [27.0%], p = 0.023), bilateral pulmonary artery Z-score < - 2 (19 [28.0%] v 36 [14.3%], p = 0.008), and pre-intervention antegrade flow (48 [70.6%] v 104 [41.3%], p < 0.001) were more common in RVOTI. Significant center differences were noted (p < 0.001). Adjusted survival to CR by 18 months (HR = 0.87, 95% CI = 0.63-1.21, p = 0.41) and overall survival (HR = 2.08, 95% CI = 0.93-4.65, p = 0.074) were similar. RVOTI had increased interstage reintervention (HR = 2.15, 95% CI = 1.36-3.99, p = 0.001). Total anesthesia (243 [213, 277] v 328 [308, 351] minutes, p < 0.001) and cardiopulmonary bypass times (117 [103, 132] v 151 [143, 160] minutes, p < 0.001) favored RVOTI. In this multicenter comparison of physiologic palliation strategies for sTOF, survival to successful CR and overall survival were similar; however, reintervention burden was significantly higher in RVOTI.


Assuntos
Procedimento de Blalock-Taussig , Tetralogia de Fallot , Humanos , Lactente , Recém-Nascido , Cuidados Paliativos , Artéria Pulmonar/cirurgia , Estudos Retrospectivos , Resultado do Tratamento
4.
Pediatr Cardiol ; 43(3): 596-604, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34743224

RESUMO

The objective of this study was to evaluate the impact of the regular introduction of new technologies into interventional cardiac catheterization procedures, in this case new atrial septal defect (ASD) closure devices, while conducting a multi-center collaborative initiative to reduce radiation usage during all procedures. Data were collected prospectively by 8 C3PO institutions between January 1, 2014 and December 31, 2017 for ASD device closure procedures in the cardiac catheterization lab during a quality improvement (QI) initiative aimed at reducing patient radiation exposure. Radiation exposure was measured in dose area product per body weight (µGy*m2/kg). Use of proposed practice change strategies at the beginning and end of the QI intervention period was assessed. Radiation exposure was summarized by institution and by initial type of device used for closure. This study included 602 ASD device closures. Without changes in patient characteristics, total fluoroscopy duration, or number of digital acquisitions, median radiation exposure decreased from 37 DAP/kg to 14 DAP/kg from 2014 to 2017. While all individual centers decreased overall median DAP/kg, the use of novel devices for ASD closure correlated with a temporary period of worsening institutional radiation exposure and increased fluoroscopy time. The introduction of new ASD closure devices resulted in increased radiation exposure during a QI project designed to reduce radiation exposure. Therefore, outcome assessment must be contextualized in QI projects, hospital evaluation, and public reporting, to acknowledge the expected variation during innovation and introduction of novel therapies.


Assuntos
Comunicação Interatrial , Exposição à Radiação , Dispositivo para Oclusão Septal , Cateterismo Cardíaco/métodos , Fluoroscopia/métodos , Comunicação Interatrial/cirurgia , Humanos , Melhoria de Qualidade , Doses de Radiação , Exposição à Radiação/prevenção & controle , Estudos Retrospectivos , Resultado do Tratamento
5.
Pediatr Cardiol ; 42(3): 533-542, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-33394118

RESUMO

Isolated pulmonary artery (PA) of ductal origin (IPADO) is a rare cardiac defect which requires surgical repair, with or without preceding palliation. We sought to determine the impact of treatment strategy on outcomes. Retrospective study of consecutive patients with IPADO that underwent staged or primary repair from 1/05 to 9/16 at 6 Congenital Cardiac Research Collaborative centers. Patients with single ventricle physiology, major aortopulmonary collaterals, or bilateral IPADO were excluded. Primary outcome was isolated PA z-score at late follow-up. Secondary outcomes included PA symmetry index (isolated:confluent PA diameter) and reintervention burden. Propensity score adjustment was used to account for baseline differences. Of 60 patients in the study cohort, 26 (43%) underwent staged and 34 (57%) primary repair. The staged and primary repair groups differed in weight at diagnosis and presence of other heart disease but not in baseline PA dimensions. Staged patients underwent ductal stent (n = 16) or surgical shunt (n = 10) placement followed by repair at 210 vs. 21 days in the primary repair group (p < 0.001). At median follow-up of 4.5 years post-repair, after adjustment, isolated PA z-score (- 0.74 [- 1.75, - 0.26] vs. - 1.95 [- 2.91, - 1.59], p = 0.012) and PA symmetry index (0.81 [0.49, 1.0] vs. 0.55 [0.48, 0.69], p = 0.042) significantly favored the staged repair group. Freedom from PA reintervention was not different between groups (adjusted HR 0.78 [0.41, 1.48]; p = 0.445). A staged approach to repair of IPADO is associated with superior isolated PA size and symmetry at late follow-up. Consideration should be given to initial palliation in IPADO patients, when feasible.


Assuntos
Procedimentos Cirúrgicos Cardíacos/métodos , Cardiopatias Congênitas/cirurgia , Artéria Pulmonar/anormalidades , Artéria Pulmonar/cirurgia , Cateterismo Cardíaco/métodos , Permeabilidade do Canal Arterial/cirurgia , Feminino , Humanos , Lactente , Recém-Nascido , Masculino , Cuidados Paliativos/métodos , Reoperação/métodos , Estudos Retrospectivos , Stents , Resultado do Tratamento
6.
Cardiol Young ; 31(11): 1829-1834, 2021 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33726868

RESUMO

BACKGROUND: Multicentre research databases can provide insights into healthcare processes to improve outcomes and make practice recommendations for novel approaches. Effective audits can establish a framework for reporting research efforts, ensuring accurate reporting, and spearheading quality improvement. Although a variety of data auditing models and standards exist, barriers to effective auditing including costs, regulatory requirements, travel, and design complexity must be considered. MATERIALS AND METHODS: The Congenital Cardiac Research Collaborative conducted a virtual data training initiative and remote source data verification audit on a retrospective multicentre dataset. CCRC investigators across nine institutions were trained to extract and enter data into a robust dataset on patients with tetralogy of Fallot who required neonatal intervention. Centres provided de-identified source files for a randomised 10% patient sample audit. Key auditing variables, discrepancy types, and severity levels were analysed across two study groups, primary repair and staged repair. RESULTS: Of the total 572 study patients, data from 58 patients (31 staged repairs and 27 primary repairs) were source data verified. Amongst the 1790 variables audited, 45 discrepancies were discovered, resulting in an overall accuracy rate of 97.5%. High accuracy rates were consistent across all CCRC institutions ranging from 94.6% to 99.4% and were reported for both minor (1.5%) and major discrepancies type classifications (1.1%). CONCLUSION: Findings indicate that implementing a virtual multicentre training initiative and remote source data verification audit can identify data quality concerns and produce a reliable, high-quality dataset. Remote auditing capacity is especially important during the current COVID-19 pandemic.


Assuntos
COVID-19 , Confiabilidade dos Dados , Humanos , Recém-Nascido , Pandemias , Estudos Retrospectivos , SARS-CoV-2
7.
Catheter Cardiovasc Interv ; 95(4): 726-733, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-31815357

RESUMO

BACKGROUND: Carotid artery (CA) and axillary artery (AA) access are increasingly used for transcatheter stenting of the patent ductus arteriosus (PDA), although reports are limited. METHODS: The Congenital Catheterization Research Collaborative (CCRC) reviewed multicenter data from infants who underwent PDA stenting via the CA or AA approach from 2008 to 2017, and compared outcomes to those of infants undergoing PDA stenting via the femoral artery (FA) approach. Post-procedure ultrasound (US) imaging was reviewed. RESULTS: Forty-nine infants underwent PDA stenting from the CA (n = 43) or AA (n = 6) approach, compared with 55 infants who underwent PDA stenting from the FA approach. The PDA was the sole pulmonary blood flow (PBF) source in 61% of infants in the CA/AA cohort, compared with 33% of the FA cohort (p < .01). Ductal tortuosity for CA/AA cohort was Type I (straight) in 10 (20%), Type II (one turn) in 17 (35%), and Type III (multiple turns) in 22 (45%) infants and reflected a greater degree of tortuosity when compared to the FA cohort (p < .01). In 17 infants with CA/AA approach, the "flip technique" was used, and was associated with shorter procedure times for highly tortuous PDA (Type III) patients. Rates of procedural complications were similar across access sites. Most common complications were access site injury (thrombus or bleeding) and stent malposition. No complications were specifically related to the "flip technique." CONCLUSIONS: Use of CA and AA approach for PDA stenting was found to be more commonly employed in sole source PBF and highly tortuous PDAs. Procedural modifications such as the "flip technique" may lead to shorter procedure times. CA and AA approaches are associated with a similar burden of procedural or late complications. Post-procedural surveillance of the CA and AA is suggested, given the incidence of vascular findings on US.


Assuntos
Artéria Axilar , Cateterismo Cardíaco/instrumentação , Artérias Carótidas , Cateterismo Periférico , Permeabilidade do Canal Arterial/terapia , Artéria Femoral , Cuidados Paliativos , Circulação Pulmonar , Stents , Artéria Axilar/diagnóstico por imagem , Cateterismo Cardíaco/efeitos adversos , Artérias Carótidas/diagnóstico por imagem , Cateterismo Periférico/efeitos adversos , Permeabilidade do Canal Arterial/diagnóstico por imagem , Permeabilidade do Canal Arterial/fisiopatologia , Feminino , Artéria Femoral/diagnóstico por imagem , Humanos , Recém-Nascido , Masculino , Punções , Estudos Retrospectivos , Resultado do Tratamento , Ultrassonografia de Intervenção , Estados Unidos
8.
Cardiol Young ; 30(12): 1923-1929, 2020 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-33050969

RESUMO

OBJECTIVE: Operators are mindful of the balloon-to-aortic annulus ratio when performing balloon aortic valvuloplasty. The method of measurement of the aortic valve annulus has not been standardised. METHODS AND RESULTS: Patients who underwent aortic valvuloplasty at two paediatric centres between 2007 and 2014 were included. The valve annulus measured by echocardiography and angiography was used to calculate the balloon-to-aortic annulus ratio and measurements were compared. The primary endpoint was an increase in aortic insufficiency by ≥2 degrees. Ninety-eight patients with a median age at valvuloplasty of 2.1 months (Interquartile range (IQR): 0.2-105.5) were included. The angiographic-based annulus was 8.2 mm (IQR: 6.8-16.0), which was greater than echocardiogram-based annulus of 7.5 mm (IQR: 6.1-14.8) (p < 0.001). This corresponded to a significantly lower angiographic balloon-to-aortic annulus ratio of 0.9 (IQR: 0.9-1.0), compared to an echocardiographic ratio of 1.1 (IQR: 1.0-1.1) (p < 0.001). The degree of discrepancy in measured diameter increased with smaller valve diameters (p = 0.041) and in neonates (p = 0.044). There was significant disagreement between angiographic and echocardiographic balloon-to-aortic annulus ratio measures regarding "High" ratio of >1.2, with angiographic ratio flagging only 2/12 (16.7%) of patients flagged by echocardiographic ratio as "High" (p = 0.012). Patients who had an increase in the degree of aortic insufficiency post valvuloplasty, only 3 (5.5%) had angiographic ratio > 1.1, while 21 (38%) had echocardiographic ratio >1.1 (p < 0.001). Patients with resultant ≥ moderate insufficiency more often had an echocardiographic ratio of >1.1 than angiographic ratio of >1.1 There was no association between increase in balloon-to-aortic annulus ratio and gradient reduction. CONCLUSIONS: Angiographic measurement is associated with a greater measured aortic valve annulus and the development of aortic insufficiency. Operators should use caution when relying solely on angiographic measurement when performing balloon aortic valvuloplasty.


Assuntos
Estenose da Valva Aórtica , Valvuloplastia com Balão , Angiografia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico , Estenose da Valva Aórtica/cirurgia , Criança , Ecocardiografia , Humanos , Lactente , Recém-Nascido , Estudos Retrospectivos , Resultado do Tratamento
9.
Catheter Cardiovasc Interv ; 92(7): E471-E477, 2018 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-30208245

RESUMO

OBJECTIVES: To evaluate differences in radiation dose and image quality across institutions, fluoroscope vendors and generations of fluoroscopes for pediatric cardiac catheterization. BACKGROUND: Increased recognition of the potentially harmful effects of ionizing radiation has spurred technological advances in fluoroscopes, as well as increased focus on optimizing fluoroscope performance. There is currently little understanding of variability in the dose-image quality relationship across institutions, fluoroscope vendor and/or generation of equipment. METHODS: We evaluated latest generation fluoroscopes from Phillips, Siemens, GE, and Toshiba, and an older generation Phillips fluoroscope (release date 2003) at three different institutions. Radiation dose was measured using an anthropomorphic dose-assessment phantom with effective dose in mSv estimated from Monte Carlo simulations. Image quality phantom images were scored on a 12-point scale by three blinded reviewers. RESULTS: Fluoroscope effective doses ranged from 0.04 to 0.14 mSv/1,000 pulses for fluoroscopy with associated composite image quality scores ranging from 8.0 ± 0.6 to 10.4 ± 1.3. For cineangiography, effective doses ranged from 0.17 to 0.57 mSv/1,000 frames with image quality scores ranging from 10.1 ± 0.3 to 11.1 ± 0.3. There was modest correlation between effective dose and image quality (r = 0.67, P = 0.006). The older generation fluoroscope delivered consistently higher doses than the newer generation systems (2.3- to 3.5-fold higher for fluoroscopy; 1.1- to 3.4-fold higher for cineangiography) without appreciable differences in image quality. CONCLUSION: Technological advances have markedly improved fluoroscope performance. Comparing latest generation systems across vendors and institutions, we found variability in the dose-IQ relationship and speculate that this reflects both equipment and institutional optimization practices.


Assuntos
Cateterismo Cardíaco/instrumentação , Cineangiografia/instrumentação , Angiografia Coronária/instrumentação , Doses de Radiação , Exposição à Radiação , Radiografia Intervencionista/instrumentação , Cateterismo Cardíaco/efeitos adversos , Cineangiografia/efeitos adversos , Simulação por Computador , Angiografia Coronária/efeitos adversos , Desenho de Equipamento , Fluoroscopia/instrumentação , Humanos , Método de Monte Carlo , Imagens de Fantasmas , Valor Preditivo dos Testes , Exposição à Radiação/efeitos adversos , Monitoramento de Radiação , Radiografia Intervencionista/efeitos adversos , Reprodutibilidade dos Testes
10.
Pediatr Cardiol ; 39(1): 191-194, 2018 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-28780711

RESUMO

There is controversy regarding the management of projectile embolization, a rare complication of penetrating trauma. We present the case of a 5-year-old, 20 kg male with retrograde venous projectile embolization following traumatic injury with a pellet gun. The projectile was successfully removed utilizing a novel, percutaneous approach.


Assuntos
Embolia/cirurgia , Corpos Estranhos/cirurgia , Traumatismos Cardíacos/cirurgia , Ferimentos por Arma de Fogo/complicações , Pré-Escolar , Embolia/etiologia , Corpos Estranhos/complicações , Traumatismos Cardíacos/complicações , Traumatismos Cardíacos/etiologia , Humanos , Masculino , Ferimentos por Arma de Fogo/cirurgia
11.
Cardiol Young ; 27(4): 697-705, 2017 May.
Artigo em Inglês | MEDLINE | ID: mdl-27456367

RESUMO

OBJECTIVE: Shone's syndrome is a complex consisting of mitral valve stenosis in addition to left ventricle outflow obstruction. There are a few studies evaluating the long-term outcomes in this population. We sought to determine the long-term outcomes in our paediatric population with Shone's syndrome and the factors associated with left heart growth. METHODS: All patients diagnosed with Shone's syndrome with biventricular circulation treated between 1978 and 2010 were reviewed. Baseline echocardiograms and data from catheterisations were also reviewed. Number of interventions (surgical+transcatheter), incidence of mitral valve replacement, and incidence of heart transplantation were tracked. Survival of the population and left heart structural growth were also reviewed. RESULTS: A total of 121 patients with Shone's syndrome presented at a median age of 28 days (0-17.3 years) and were followed-up for 7.2 years (0.01-35.5 years). These patients underwent 258 interventions during the study period, and the presence of coarctation was associated with repeat left heart interventions. The 10-year, transplant-free survival was 86%. Presence of pulmonary hypertension was associated with mortality. Left heart structural growth was seen for mitral and aortic valve annuli and left ventricular end-diastolic dimension over time. CONCLUSIONS: Shone's syndrome patients undergo a number of left heart interventions. Coarctation of the aorta is associated with an increased likelihood for repeat interventions. Survival appears to be more favourable than expected. Significant left heart growth will occur in the population. Pulmonary hypertension is associated with an increased risk of mortality.


Assuntos
Estenose da Valva Aórtica/epidemiologia , Valva Aórtica/anormalidades , Hipertensão Pulmonar/complicações , Estenose da Valva Mitral/epidemiologia , Valva Mitral/anormalidades , Adolescente , Coartação Aórtica/diagnóstico por imagem , Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/congênito , Estenose da Valva Aórtica/diagnóstico por imagem , Criança , Pré-Escolar , Ecocardiografia , Feminino , Seguimentos , Georgia/epidemiologia , Cardiopatias Congênitas/diagnóstico por imagem , Cardiopatias Congênitas/cirurgia , Transplante de Coração , Humanos , Hipertensão Pulmonar/epidemiologia , Lactente , Recém-Nascido , Modelos Lineares , Masculino , Valva Mitral/diagnóstico por imagem , Estenose da Valva Mitral/congênito , Estenose da Valva Mitral/diagnóstico por imagem , Reoperação , Análise de Sobrevida , Síndrome
12.
J Pediatr ; 171: 67-72.e1-2, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26707578

RESUMO

OBJECTIVE: To review our institutional experience with tissue plasminogen activator (tPA) to determine outcomes related to bleeding complications and thrombus resolution. STUDY DESIGN: We performed a retrospective review of all patients who received systemic tPA for thrombolysis. Data points included location of thrombus, initial and maximum tPA dose, and duration of tPA. The primary endpoint was bleeding complication. RESULTS: Between 2005 and 2014, 46 patients received systemic tPA for thrombolysis: 17 (37%) were patients with a primary cardiac diagnosis, there were 17 (37%) hematology/oncology patients, and 12 (26%) patients with noncardiac, nonhematology/oncology diagnoses. The indication for tPA was central venous thrombus (n = 23), pulmonary artery thrombus (n = 9), and cardiac or aortic thrombus (n = 14). Bleeding complications occurred in 15 patients (33%). Median initial tPA dose in the bleeding complication group was 0.10 mg/kg/h vs 0.03 mg/kg/h in the group without bleeding complication group (P = .01). Cardiac patients experienced more bleeding complications (P = .01). Multivariate analysis indicated that dose of tPA (P = .01) and diagnostic category (P < .01) were associated with bleeding complication. Complete thrombus resolution occurred in 21 patients, partial in 10 patients, and no resolution in 15 patients. Complete resolution of thrombus was not associated with diagnosis, thrombus location, tPA dose, or duration. CONCLUSIONS: Cardiac patients appear to be at highest risk of bleeding complication; bleeding complications were associated with higher doses of tPA, and cardiac patients were the cohort who received the highest doses of tPA. Higher tPA doses are associated with increased risk of bleeding complication but are not associated with successful thrombus resolution.


Assuntos
Hemorragia/terapia , Trombose/tratamento farmacológico , Ativador de Plasminogênio Tecidual/uso terapêutico , Adolescente , Criança , Pré-Escolar , Feminino , Insuficiência Cardíaca/congênito , Insuficiência Cardíaca/terapia , Humanos , Lactente , Unidades de Terapia Intensiva Pediátrica , Masculino , Análise Multivariada , Probabilidade , Estudos Retrospectivos , Fatores de Risco , Terapia Trombolítica/métodos , Resultado do Tratamento
13.
Catheter Cardiovasc Interv ; 86(2): 271-7, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25726838

RESUMO

OBJECTIVES: The purpose of this study was to examine the outcomes of catheter dilation interventions in general upon surgical anastomotic sites in the immediate postoperative period. BACKGROUND: Early postoperative cardiac catheter intervention is regarded as high-risk, particularly when a dilation intervention across a fresh suture line is performed. METHODS: All catheter dilation interventions performed upon a fresh suture line within 30 days of congenital heart surgery between August 2005 and December 2013 were reviewed. Values are reported as median and interquartile range (IQR). Primary endpoint was procedural success, which was defined as an increase in vessel diameter of >75% of the adjacent normal vessel or 50% increase over pre-dilation diameter. Secondary endpoints included procedural complications and survival to hospital discharge. RESULTS: Forty-five patients, median age 0.15 years (0.03-0.51 years), weight 4.1 kg (3.1-6.4 kg), underwent 62 interventional procedures on median postoperative day 7 (3-13 days). Among the 62 dilation interventions at surgical anastomotic areas, were 30 stent and 32 balloon angioplasty procedures. There were two major complications including: arterial dissection during stent placement and a procedural mortality due to pulmonary artery avulsion during angioplasty. There were 12 deaths (27%) prior to hospital discharge. The median ratio of maximum stent diameter to stenosis diameter was 2.62 (2.27-3.73). The median ratio of maximum balloon diameter to stenosis diameter was 2.27 (1.84-2.94). Stent placement was more likely to result in procedural success (OR 2.1; 95% confidence interval 1.6-2.8). CONCLUSION: Though caution is paramount, early postoperative catheter dilation intervention across fresh suture lines can be performed safely in small, critically ill children.


Assuntos
Angioplastia Coronária com Balão , Cateterismo Cardíaco , Procedimentos Cirúrgicos Cardíacos , Cardiopatias Congênitas/terapia , Técnicas de Sutura , Fatores Etários , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/instrumentação , Angioplastia Coronária com Balão/mortalidade , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/mortalidade , Cateteres Cardíacos , Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Procedimentos Cirúrgicos Cardíacos/mortalidade , Pré-Escolar , Dilatação , Georgia , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/mortalidade , Cardiopatias Congênitas/cirurgia , Mortalidade Hospitalar , Humanos , Lactente , Alta do Paciente , Desenho de Prótese , Radiografia Intervencionista , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Stents , Técnicas de Sutura/efeitos adversos , Técnicas de Sutura/mortalidade , Fatores de Tempo , Resultado do Tratamento
14.
Catheter Cardiovasc Interv ; 86(5): 834-40, 2015 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-26154511

RESUMO

OBJECTIVE: The objective is to quantify radiation dose in children undergoing cardiac catheterization and determine the impact of increased reporting transparency on total radiation exposure. BACKGROUND: Cardiac catheterization (cath) can result in significant radiation exposure in children. There has been growing interest in quantifying and reducing radiation exposure in pediatric cath procedures. Our center underwent a slight change in practice recently that resulted in direct physician reporting of radiation dose following every case. METHODS: We reviewed cath procedures across three different eras in four cath categories: post-heart transplant annual cath, unilateral pulmonary artery (PA) stent placement, pre-Fontan cath, and pre-Glenn cath. The eras were defined as: Era 1, 1/2009-1/2011; Era 2, 1/2011-9/2013; and Era 3, 9/2013-5/2014. In Era 3, the physician performing the cath was responsible for reporting the radiation data. RESULTS: Across the three eras, there were significant decreases in cumulative air KERMA (mGy) among all four cath categories. From Era 2 to Era 3, the greatest decreases in radiation were noted, particularly in dose area product (cGy·cm2) in the transplant annual evaluation and pre-Glenn cases. In Era 1, 2 cases (1.2%) had a frame rate reduction, while in Era 2, 22 cases (12.0%), and in Era 3, 83 cases (21.6%) had frame rate changes (P<0.01). CONCLUSIONS: Increased physician awareness of radiation exposure is associated with a significant reduction in radiation dose across a variety of cath procedures. This is seen not only by the overall reduction in radiation across case types, but also as the frame rate was more frequently changed during individual cases, indicating an important change in physician behavior and practice.


Assuntos
Cateterismo Cardíaco , Angiografia Coronária , Cardiopatias Congênitas/diagnóstico por imagem , Papel do Médico , Doses de Radiação , Exposição à Radiação/prevenção & controle , Monitoramento de Radiação/métodos , Radiografia Intervencionista , Adolescente , Fatores Etários , Atitude do Pessoal de Saúde , Cateterismo Cardíaco/efeitos adversos , Criança , Pré-Escolar , Angiografia Coronária/efeitos adversos , Georgia , Conhecimentos, Atitudes e Prática em Saúde , Cardiopatias Congênitas/terapia , Humanos , Lactente , Padrões de Prática Médica , Exposição à Radiação/efeitos adversos , Proteção Radiológica , Radiografia Intervencionista/efeitos adversos , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo
15.
Pediatr Cardiol ; 36(6): 1153-8, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-25792000

RESUMO

Prior to initiation of a formal screening program, 30 % of patients referred for device closure of an atrial septal defect (ASD) at our institution had atrial septal anatomy which precluded ASD device closure. This resulted in inefficiencies in workflow, staff utilization, and inconvenience for families. Our objective was to report our experience with an ASD prescreening evaluation/protocol and family consultation process. This is a retrospective study of pediatric patients who underwent a comprehensive ASD prescreening evaluation at Children's Healthcare of Atlanta between January 2011 and June 2013. The comprehensive prescreening process included a detailed transthoracic echocardiogram and family consultation. Upon establishing a formal prescreening process for patients with secundum ASDs, 138 patients were screened for appropriateness of ASD device closure. At time of prescreening, 40 patients (29 %) were deemed not to be suitable candidates for device ASD closure. In 9 patients (6.5 %), after discussion with the interventionalist, parents elected to pursue surgical ASD closure. A total of 78 patients (56.5 %) underwent successful transcutaneous ASD device closure. In addition, there was a significant discrepancy in the reported size of the ASD between the outside evaluation and the ASD size discovered during the prescreening process. The addition of a prescreening program for transcatheter ASD closure has decreased the incidence of unsuccessful ASD closure from 30 to 10.3 %. The use of a comprehensive evaluation process for ASD device closure improves the likelihood of successful device implantation and permits adequate preprocedural counseling for the patient and family.


Assuntos
Septo Interatrial/diagnóstico por imagem , Cateterismo Cardíaco/métodos , Diagnóstico Precoce , Ecocardiografia , Comunicação Interatrial/cirurgia , Avaliação de Programas e Projetos de Saúde/métodos , Criança , Pré-Escolar , Estudos de Avaliação como Assunto , Feminino , Comunicação Interatrial/diagnóstico por imagem , Humanos , Masculino , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
16.
Circ Cardiovasc Interv ; 17(3): e012834, 2024 03.
Artigo em Inglês | MEDLINE | ID: mdl-38258562

RESUMO

BACKGROUND: Current metrics used to adjust for case mix complexity in congenital cardiac catheterization are becoming outdated due to the introduction of novel procedures, innovative technologies, and expanding patient subgroups. This study aims to develop a risk adjustment methodology introducing a novel, clinically meaningful adverse event outcome and incorporating a modern understanding of risk. METHODS: Data from diagnostic only and interventional cases with defined case types were collected for patients ≤18 years of age and ≥2.5 kg at all Congenital Cardiac Catheterization Project on Outcomes participating centers. The derivation data set consisted of cases performed from 2014 to 2017, and the validation data set consisted of cases performed from 2019 to 2020. Severity level 3 adverse events were stratified into 3 tiers by clinical impact (3a/b/c); the study outcome was clinically meaningful adverse events, severity level ≥3b (3bc/4/5). RESULTS: The derivation data set contained 15 224 cases, and the validation data set included 9462 cases. Clinically meaningful adverse event rates were 4.5% and 4.2% in the derivation and validation cohorts, respectively. The final risk adjustment model included age <30 days, Procedural Risk in Congenital Cardiac Catheterization risk category, and hemodynamic vulnerability score (C statistic, 0.70; Hosmer-Lemeshow P value, 0.83; Brier score, 0.042). CONCLUSIONS: CHARM II (Congenital Heart Disease Adjustment for Risk Method II) risk adjustment methodology allows for equitable comparison of clinically meaningful adverse events among institutions and operators with varying patient populations and case mix complexity performing pediatric cardiac catheterization.


Assuntos
Cateterismo Cardíaco , Cardiopatias Congênitas , Criança , Humanos , Lactente , Fatores de Risco , Resultado do Tratamento , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/métodos , Cardiopatias Congênitas/diagnóstico , Cardiopatias Congênitas/terapia , Hemodinâmica , Risco Ajustado/métodos
17.
Catheter Cardiovasc Interv ; 82(5): E704-7, 2013 Nov 01.
Artigo em Inglês | MEDLINE | ID: mdl-23420640

RESUMO

A newborn infant with obstructed supracardiac total anomalous pulmonary venous return underwent emergent surgical correction on day of life 0. A surgically placed transthoracic pulmonary artery catheter was used to monitor pulmonary artery pressure and removed on postoperative day 3. Following acute deterioration in respiratory status requiring reintubation, echocardiographic assessment demonstrated findings consistent with pulmonary hypertension and diminished flow to the left lung. Cardiac catheterization confirmed elevated pulmonary artery pressure and near complete occlusion of his left pulmonary artery due to a thrombus. He underwent successful percutaneous catheter-based thrombectomy using the AngioJet rheolytic catheter, recovered fully, and was discharged home on postoperative day 30. Although thrombotic events resulting in respiratory and hemodynamic compromise are rare in infants, recognition is important and treatment using mechanical thrombectomy can be life saving.


Assuntos
Procedimentos Cirúrgicos Cardíacos/efeitos adversos , Hipertensão Pulmonar/cirurgia , Artéria Pulmonar/cirurgia , Síndrome de Cimitarra/cirurgia , Trombectomia/métodos , Trombose/cirurgia , Pressão Arterial , Hipertensão Pulmonar Primária Familiar , Humanos , Hipertensão Pulmonar/diagnóstico , Hipertensão Pulmonar/etiologia , Hipertensão Pulmonar/fisiopatologia , Recém-Nascido , Masculino , Artéria Pulmonar/diagnóstico por imagem , Artéria Pulmonar/fisiopatologia , Radiografia , Síndrome de Cimitarra/diagnóstico , Trombose/diagnóstico , Trombose/etiologia , Trombose/fisiopatologia , Resultado do Tratamento
18.
Pediatr Cardiol ; 34(8): 1966-8, 2013.
Artigo em Inglês | MEDLINE | ID: mdl-22987110

RESUMO

This report describes the case of two pediatric patients who demonstrated echocardiographic evidence of pulmonary hypertension (PH) during the acute phase of Kawasaki disease. The etiology of PH development in this setting is currently unknown, but the authors hypothesize that pulmonary vasculitis may play a significant role. Fortunately, the PH appeared to be self-limited and resolved in both cases with routine treatment of Kawasaki disease.


Assuntos
Hipertensão Pulmonar/etiologia , Síndrome de Linfonodos Mucocutâneos/complicações , Adolescente , Pré-Escolar , Diagnóstico Diferencial , Ecocardiografia , Humanos , Hipertensão Pulmonar/diagnóstico , Hipertensão Pulmonar/fisiopatologia , Masculino , Síndrome de Linfonodos Mucocutâneos/diagnóstico , Pressão Propulsora Pulmonar , Tomografia Computadorizada por Raios X
19.
Pediatr Cardiol ; 34(2): 316-21, 2013 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-22890625

RESUMO

Infants with congenital heart disease have impaired weight gain during the first several months of life. Efforts have focused on improving weight gain and nutritional status during the first months of life. Close examination of the data suggests that the immediate postoperative period is problematic. Etiology of this early growth failure should be identified to develop effective interventions. This is a retrospective study of neonates who underwent modified systemic-to-pulmonary artery shunt, including Norwood palliation, at Children's Healthcare of Atlanta between January 2009 and July 2011. We analyzed growth from time of surgical intervention to hospital discharge. Measures of calculated weight-for-age Z-score (WAZ score) were performed using the World Health Organization's Anthro Software (version 3.2.2, January 2011; WHO, Geneva, Switzerland). Seventy-three patients were identified. Eight patients did not meet inclusion criteria. Complete data were collected on the remaining 65 patients. Median caloric intake patients received was 50.4 [interquartile range (IQR) 41.6 to 63.6] calories/kg/day while exclusively on parental nutrition. At hospital discharge, the median WAZ score was -2.0 (IQR -2.7 to -1.2) representing an overall median WAZ score decrease of -1.3 (IQR -1.7 to -0.7) from time of shunt palliation to hospital discharge. Despite studies showing poor weight gain in infants with congenital heart disease after neonatal palliation, this study reports the impact of hospital-based nutritional practices on weight gain in infants during the immediate postoperative period. Our data demonstrate that actual caloric intake during the cardiac intensive care unit stay is substantially below what is recommended.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Ingestão de Energia , Insuficiência de Crescimento/dietoterapia , Cardiopatias Congênitas/cirurgia , Estado Nutricional , Peso Corporal , Insuficiência de Crescimento/diagnóstico , Insuficiência de Crescimento/etiologia , Feminino , Seguimentos , Cardiopatias Congênitas/complicações , Humanos , Recém-Nascido , Masculino , Período Perioperatório , Estudos Retrospectivos , Aumento de Peso
20.
JTCVS Open ; 16: 844-854, 2023 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-38204728

RESUMO

Objective: To identify risk factors for aortopulmonary collateral (APC) development and assess the impact of severe APCs in children undergoing staged single ventricle palliation. Methods: Children undergoing a bidirectional Glenn operation between January 1, 2016, and March 31, 2021, at our center were included. All underwent angiography prior to Glenn and Fontan; APC flow was graded on a scale of 0 (no appreciable collateral flow) to 4 (severe burden). Demographic data, congenital diagnosis, clinical history, and outcomes were stratified by Glenn assessment; Fontan outcomes were stratified by pre-Fontan grade. Results: Sixty patients met the inclusion criteria, all of whom had angiographic evidence of APCs. There were 7 transplants and 9 deaths in the cohort. There were no significant differences in demographics among the patients. Right ventricular morphology was more common in patients with severe pre-Glenn collaterals (24 of 44 vs 2 of 6 vs 7 of 8; P = .014). Longer stage 1 aortic cross-clamp duration was associated with greater severity pre-Glenn (44 minutes vs 34 minutes vs 66 minutes; P = .023). Patients with grade 3 pre-Glenn collaterals more commonly required transplantation than those with grade 1 collaterals (P < .001) and had lower overall transplant-free survival than those with grade 1 (P = .005) or grade 2 (P = .04) collaterals. Conclusions: The ubiquity of APCs in this study demonstrates their prevalence in single ventricle disease. Right ventricular morphology and prolonged aortic cross-clamp duration are associated with higher burden. Greater severity was associated with decreased transplant-free survival. These data emphasize the negative long-term impact of these collaterals.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA