Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 190
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38507041

RESUMO

BACKGROUND: The withdrawal timing of direct oral anticoagulants (DOACs) among patients in need of elective invasive surgery is based on DOAC pharmacokinetics in order to perform the procedure out of the DOAC peak plasma concentration. We aimed to investigate the prevalence and predictors of plasma levels of DOACs out of trough range in patients with atrial fibrillation (AF) in need of elective cardiac procedure. MATERIALS AND METHODS: We evaluated all consecutive AF patients on DOAC therapy in need of elective cardiac procedure, admitted to our division from January 2022 to March 2022. All patients underwent DOAC plasma dosing the morning of procedure day. They were categorized as in range, above range, and below range, according to the DOAC reference range at the downstream point. The timing of discontinuation of DOAC therapy was considered as appropriate or not, according to the current recommendations. The clinical predictors of out-of-range DOAC plasma levels have been evaluated. RESULTS: We included 90 consecutive AF patients (56.6% male, mean age 72.95 ± 10.12 years); 74 patients (82.22%) showed DOAC concentration out of the expected reference range. In half of them (n, 37), the DOAC plasma concentration was below the trough reference range. Of the study population, 17.7% received inappropriate DOAC dosages (10% overdosing, 7% underdosing), and 35.5% had incorrect timing of DOAC withdrawal (26% prolonged, 9.5% shortened). At multivariable analysis, inappropriate longer DOAC withdrawal period (OR 10.13; P ≤ 0.0001) and increased creatinine clearance (OR 1.01; P = 0.0095) were the independent predictors of plasma DOAC levels below the therapeutic trough range. In contrast, diabetes mellitus (OR 4.57; P = 0.001) was the only independent predictor of DOAC plasma level above the therapeutic trough range. CONCLUSION: Increased creatinine clearance and inappropriate longer drug withdrawal period are the only independent predictors of DOAC plasma levels below the reference range; in contrast, diabetes is significantly correlated with DOAC plasma levels above the reference.

2.
Clin Auton Res ; 34(1): 137-142, 2024 02.
Artigo em Inglês | MEDLINE | ID: mdl-38402334

RESUMO

BACKGROUND: Approximately 50% of patients with unexplained syncope and negative head-up tilt test (HUTT) who have an electrocardiogram (ECG) documentation of spontaneous syncope during implantable loop recorder (ILR) show an asystolic pause at the time of the event. OBJECTIVE: The aim of the study was to evaluate the age distribution and clinical predictors of asystolic syncope detected by ILR in patients with unexplained syncope and negative HUTT. METHODS: This research employed a retrospective, single-center study of consecutive patients. The ILR-documented spontaneous syncope was classified according to the International Study on Syncope of Uncertain Etiology (ISSUE) classification. RESULTS: Among 113 patients (54.0 ± 19.6 years; 46% male), 49 had an ECG-documented recurrence of syncope during the observation period and 28 of these later (24.8%, corresponding to 57.1% of the patients with a diagnostic event) had a diagnosis of asystolic syncope at ILR: type 1A was present in 24 (85.7%), type 1B in 1 (3.6%), and type 1C in 3 (10.7%) patients. The age distribution of asystolic syncope was bimodal, with a peak at age < 19 years and a second peak at the age of 60-79 years. At Cox multivariable analysis, syncope without prodromes (OR 3.7; p = 0.0008) and use of beta blockers (OR 3.2; p = 0.002) were independently associated to ILR-detected asystole. CONCLUSIONS: In patients with unexplained syncope and negative HUTT, the age distribution of asystolic syncope detected by ILR is bimodal, suggesting a different mechanism responsible for asystole in both younger and older patients. The absence of prodromes and the use of beta blockers are independent predictors of ILR-detected asystole.


Assuntos
Parada Cardíaca , Síncope , Humanos , Masculino , Adulto Jovem , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Estudos Retrospectivos , Distribuição por Idade , Síncope/diagnóstico , Síncope/etiologia , Parada Cardíaca/complicações , Eletrocardiografia , Eletrocardiografia Ambulatorial/efeitos adversos
3.
Eur Heart J ; 44(27): 2473-2479, 2023 Jul 14.
Artigo em Inglês | MEDLINE | ID: mdl-37264671

RESUMO

BACKGROUND: The traditional nitroglycerin (NTG) head-up tilt test (HUTT) is time-consuming and the test duration is a barrier to widespread utilization in clinical practice. It was hypothesized that a short-duration protocol is not inferior to the traditional protocol regarding the positivity rate and has a similar distribution of hemodynamic response. METHODS AND RESULTS: Patients undergoing HUTT were randomized 1:1 to a 10 min passive phase plus a 10 min 0.3 mg NTG if the passive phase was negative (Fast) or to a 20 min passive phase plus a 15 min 0.3 mg NTG if the passive phase was negative (Traditional). A sample size of 277 patients for each group achieved 80% power to detect an expected difference of 0% with a non-inferiority margin of -10% using a one-sided t-test and assuming a significant level alpha of 0.025. A total of 554 consecutive patients (mean age 46.6 ± 19.3 years, 47.6% males) undergoing HUTT for suspected vasovagal syncope were randomly assigned to the Fast (n = 277) or Traditional (n = 277) protocol. A positive response was defined as the induction of syncope in presence of hypotension/bradycardia, and was observed in 167 (60.3%) patients with Fast and in 162 (58.5%) patients with the Traditional protocol. There was a trend of lesser vasodepressor response (14.8% Fast vs. 20.6% Traditional) which was significant during the passive phase (P = 0.01). CONCLUSION: The diagnostic value of the Fast HUTT protocol is similar to that of the Traditional protocol and therefore the Fast protocol can be used instead of the Traditional protocol.


Assuntos
Nitroglicerina , Síncope Vasovagal , Masculino , Humanos , Adulto , Pessoa de Meia-Idade , Idoso , Feminino , Síncope Vasovagal/diagnóstico , Vasodilatadores , Síncope/diagnóstico , Teste da Mesa Inclinada/métodos , Ensaios Clínicos Controlados Aleatórios como Assunto
4.
J Cardiovasc Pharmacol ; 82(3): 196-200, 2023 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-37405837

RESUMO

ABSTRACT: Sodium-glucose cotransporter 2 inhibitors (SGLT2-i) are a novel class of oral hypoglycemic agents currently used among patients with type 2 diabetes mellitus (T2DM). The effects of SGLT2-i inhibitors on cardiac structure and function are not fully understood. The aim of this study is to evaluate the echocardiographic changing among patients with well-controlled T2DM treated with SGLT2-i in real-world setting. Thirty-five well-controlled T2DM patients (65 ± 9 years, 43.7% male) with preserved left ventricular ejection fraction (LVEF) and 35 age and sex-matched controls were included. T2DM patients underwent clinical and laboratory evaluation; 12-lead surface electrocardiogram; 2-dimensional color Doppler echocardiography at enrolment, before SGLT2-i administration, and at 6 months follow-up after an uninterrupted 10 mg once daily of empagliflozin (n: 21) or dapagliflozin (n: 14). Standard echocardiographic measurements, LV global longitudinal strain (LV-GLS), global wasted work, and global work efficiency were calculated. T2DM patients showed higher E\E' ratio (8.3 ± 2.5 vs. 6.3 ± 0.9; P < 0.0001 ) and lower LV-GLS (15.8 ± 8.1 vs. 22.1 ± 1.4%; P < 0.0001 ) and global myocardial work efficiency (91 ± 4 vs. 94 ± 3%; P: 0.0007 ) compared with age and sex-matched controls. At 6-month follow-up, T2DM patients showed a significant increase in LVEF (58.9 ± 3.2 vs. 62 ± 3.2; P < 0.0001 ), LV-GLS (16.2 ± 2.8 vs. 18.7 ± 2.4%; P = 0.003 ), and global work efficiency (90.3 ± 3.5 vs. 93.3 ± 3.2%; P = 0.0004 ) values; conversely, global wasted work values (161.2 ± 33.6 vs. 112.72 ± 37.3 mm Hg%; P < 0.0001 ) significantly decreased. Well-controlled T2DM patients with preserved LVEF who are treated with a SGLT2-i on top of the guidelines direct medical therapy showed a favorable cardiac remodeling, characterized by the improvement of LV-GLS and myocardial work efficiency.


Assuntos
Diabetes Mellitus Tipo 2 , Disfunção Ventricular Esquerda , Humanos , Masculino , Feminino , Volume Sistólico , Função Ventricular Esquerda , Diabetes Mellitus Tipo 2/diagnóstico , Diabetes Mellitus Tipo 2/tratamento farmacológico , Transportador 2 de Glucose-Sódio/farmacologia , Transportador 2 de Glucose-Sódio/uso terapêutico , Deformação Longitudinal Global , Glucose , Sódio
5.
J Cardiovasc Pharmacol ; 81(2): 129-133, 2023 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-36607629

RESUMO

ABSTRACT: Dual pathway inhibition (DPI) with low-dose rivaroxaban and aspirin in patients with coronary artery disease (CAD) and/or peripheral artery disease (PAD) reduces the occurrence of cardiovascular (CV) events; however, the underlying mechanisms explaining these latter CV benefits are not clearly understood. Our explorative observational study aimed to evaluate the effect of dual pathway inhibition on plasma inflammation and coagulation markers among real-world patients with CAD and/or PAD. We prospectively included all consecutive patients with an established diagnosis of CAD and/or PAD treated with aspirin 100 mg once daily (OD) and rivaroxaban 2.5 mg twice daily (TD). Clinical evaluation and laboratory analyses, including hemoglobin, renal function (creatinine, urea, and cystatin-C), coagulation markers (INR and aPTT), inflammation markers (IL-6, CRP, lipoprotein-associated phospholipase A2, and copeptin), and growth differentiation factor-15 (GDF-15), were conducted at baseline, before starting treatment, and at 4 and 24 weeks after study drug administration. Fifty-four consecutive patients (mean age 66 ± 7 years; male 83%) who completed the 6-month follow-up were included. At 24-week follow-up, a statistically significant reduction in IL-6 serum levels [4.6 (3.5-6.5) vs. 3.4 (2.4-4.3) pg/mL ; P = 0.0001] and fibrinogen [336 (290-390) vs. 310 (275-364) mg/dL; P = 0.04] was shown; moreover, a significant increase in GDF-15 serum level [1309 (974-1961) vs. 1538 (1286-2913) pg/mL; P = 0.002] was observed. Hemoglobin, renal function, and cardiovascular homeostasis biomarkers remain stable over the time. The anti-Xa activity at both [0.005 (0-0.02) vs. 0.2 (0.1-0.34); P < 0.0001) significantly increased. The dual pathway inhibitions with low-dose rivaroxaban and aspirin in patients with CAD and/or PAD were associated with the reduction of inflammation biomarkers.


Assuntos
Aterosclerose , Doença da Artéria Coronariana , Doença Arterial Periférica , Idoso , Humanos , Masculino , Pessoa de Meia-Idade , Aspirina , Aterosclerose/tratamento farmacológico , Biomarcadores , Doença da Artéria Coronariana/tratamento farmacológico , Quimioterapia Combinada , Inibidores do Fator Xa , Fator 15 de Diferenciação de Crescimento , Inflamação/tratamento farmacológico , Interleucina-6 , Doença Arterial Periférica/tratamento farmacológico , Inibidores da Agregação Plaquetária , Rivaroxabana , Feminino
6.
Europace ; 25(1): 112-120, 2023 02 08.
Artigo em Inglês | MEDLINE | ID: mdl-36036679

RESUMO

AIMS: The safety and efficacy of leadless intracardiac-permanent pacemaker (L-PM) have been demonstrated in multiple clinical trials, but data on comparisons with conventional transvenous-permanent pacemaker (T-PM) collected in a consecutive, prospective fashion are limited. The aim of this analysis was to compare the rate and the nature of device-related complications between patients undergoing L-PM vs. T-PM implantation. METHODS AND RESULTS: Prospective, multicentre, observational project enrolling consecutive patients who underwent L-PM or T-PM implantation. The rate and nature of device-related complications were analysed and compared between the two groups. Individual 1:1 propensity matching of baseline characteristics was performed. A total of 2669 (n = 665 L-PM) patients were included and followed for a median of 39 months, L-PM patients were on average older and had more co-morbidities. The risk of device-related complications at 12 months was significantly lower in the L-PM group (0.5% vs. 1.9%, P = 0.009). Propensity matching yielded 442 matched pairs. In the matched cohort, L-PM patients trended toward having a lower risk of overall device-related complications (P = 0.129), had a similar risk of early complications (≤30 days) (P = 1.000), and had a significantly lower risk of late complications (>30 days) (P = 0.031). All complications observed in L-PM group were early. Most (75.0%) of complications observed in T-PM group were lead- or pocket-related. CONCLUSION: In this analysis, the risk of device-related complications associated with L-PM implantation tended to be lower than that of T-PM. Specifically, the risk of early complications was similar in two types of PMs, while the risk of late complications was significantly lower for L-PM than T-PM.


Assuntos
Arritmias Cardíacas , Marca-Passo Artificial , Humanos , Resultado do Tratamento , Desenho de Equipamento , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia , Arritmias Cardíacas/etiologia , Marca-Passo Artificial/efeitos adversos , Fatores de Tempo
7.
Europace ; 25(5)2023 05 19.
Artigo em Inglês | MEDLINE | ID: mdl-36932709

RESUMO

AIMS: In subcutaneous implantable cardioverter defibrillator (S-ICD) recipients, the UNTOUCHED study demonstrated a very low inappropriate shock rate on programming a conditional zone between 200 and 250 bpm and a shock zone for arrhythmias >250 bpm. The extent to which this programming approach is adopted in clinical practice is still unknown, as is its impact on the rates of inappropriate and appropriate therapies. METHODS AND RESULTS: We assessed ICD programming on implantation and during follow-up in a cohort of 1468 consecutive S-ICD recipients in 56 Italian centres. We also measured the occurrence of inappropriate and appropriate shocks during follow-up. On implantation, the median programmed conditional zone cut-off was set to 200 bpm (IQR: 200-220) and the shock zone cut-off was 230 bpm (IQR: 210-250). During follow-up, the conditional zone cut-off rate was not significantly changed, while the shock zone cut-off was changed in 622 (42%) patients and the median value increased to 250 bpm (IQR: 230-250) (P < 0.001). UNTOUCHED-like programming of detection cut-offs was adopted in 426 (29%) patients immediately after device implantation, and in 714 (49%, P < 0.001) at the last follow-up. UNTOUCHED-like programming was independently associated with fewer inappropriate shocks (hazard ratio 0.50, 95%CI 0.25-0.98, P = 0.044), and had no impact on appropriate and ineffective shocks. CONCLUSIONS: In recent years, S-ICD implanting centres have increasingly programmed high arrhythmia detection cut-off rates, at the time of implantation in the case of new S-ICD recipients, and during follow-up in the case of pre-existing implants. This has contributed significantly to reducing the incidence of inappropriate shocks in clinical practice. Rordorf: Programming of the S-ICD. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Assuntos
Desfibriladores Implantáveis , Taquicardia Ventricular , Humanos , Desfibriladores Implantáveis/efeitos adversos , Taquicardia Ventricular/diagnóstico , Seguimentos , Estudos Prospectivos , Cardioversão Elétrica , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/terapia
8.
Europace ; 25(6)2023 06 02.
Artigo em Inglês | MEDLINE | ID: mdl-37350404

RESUMO

AIMS: Subcutaneous implantable cardioverter-defibrillator (S-ICD) therapy is expanding rapidly. However, there are few data on the S-ICD extraction procedure and subsequent patient management. The aim of this analysis was to describe the procedure, management, and outcome of S-ICD extractions in clinical practice. METHODS AND RESULTS: We enrolled consecutive patients who required complete S-ICD extraction at 66 Italian centres. From 2013 to 2022, 2718 patients undergoing de novo implantation of an S-ICD were enrolled. Of these, 71 required complete S-ICD system extraction (17 owing to infection). The S-ICD system was successfully extracted in all patients, and no complications were reported; the median procedure duration was 40 (25th-75th percentile: 20-55) min. Simple manual traction was sufficient to remove the lead in 59 (84%) patients, in whom lead-dwelling time was shorter [20 (9-32) months vs. 30 (22-41) months; P = 0.032]. Hospitalization time was short in the case of both non-infectious [2 (1-2) days] and infectious indications [3 (1-6) days]. In the case of infection, no patients required post-extraction intravenous antibiotics, the median duration of any antibiotic therapy was 10 (10-14) days, and the re-implantation was performed during the same procedure in 29% of cases. No complications arose over a median of 21 months. CONCLUSION: The S-ICD extraction was safe and easy to perform, with no complications. Simple traction of the lead was successful in most patients, but specific tools could be needed for systems implanted for a longer time. The peri- and post-procedural management of S-ICD extraction was free from complications and not burdensome for patients and healthcare system. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Assuntos
Desfibriladores Implantáveis , Humanos , Administração Intravenosa , Antibacterianos , Hospitalização , Resultado do Tratamento
9.
Europace ; 25(4): 1423-1431, 2023 04 15.
Artigo em Inglês | MEDLINE | ID: mdl-36794691

RESUMO

AIMS: A previous randomized study demonstrated that the subcutaneous implantable cardioverter defibrillator (S-ICD) was noninferior to transvenous ICD with respect to device-related complications and inappropriate shocks. However, that was performed prior to the widespread adoption of pulse generator implantation in the intermuscular (IM) space instead of the traditional subcutaneous (SC) pocket. The aim of this analysis was to compare survival from device-related complications and inappropriate shocks between patients who underwent S-ICD implantation with the generator positioned in an IM position in comparison with an SC pocket. METHODS AND RESULTS: We analysed 1577 consecutive patients who had undergone S-ICD implantation from 2013 to 2021 and were followed up until December 2021. Subcutaneous patients (n = 290) were propensity matched with patients of the IM group (n = 290), and their outcomes were compared. : During a median follow-up of 28 months, device-related complications were reported in 28 (4.8%) patients and inappropriate shocks were reported in 37 (6.4%) patients. The risk of complication was lower in the matched IM group than in the SC group [hazard ratio 0.41, 95% confidence interval (CI) 0.17-0.99, P = 0.041], as well as the composite of complications and inappropriate shocks (hazard ratio 0.50, 95% CI 0.30-0.86, P = 0.013). The risk of appropriate shocks was similar between groups (hazard ratio 0.90, 95% CI 0.50-1.61, P = 0.721). There was no significant interaction between generator positioning and variables such as gender, age, body mass index, and ejection fraction. CONCLUSION: Our data showed the superiority of the IM S-ICD generator positioning in reducing device-related complications and inappropriate shocks. CLINICAL TRIAL REGISTRATION: Clinical Trial Registration: ClinicalTrials.gov; NCT02275637.


Assuntos
Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Estudos de Casos e Controles , Morte Súbita Cardíaca/etiologia , Estudos Retrospectivos , Resultado do Tratamento
10.
Europace ; 25(9)2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37536671

RESUMO

AIMS: Patients with cardiomyopathies and channelopathies are usually younger and have a predominantly arrhythmia-related prognosis; they have nearly normal life expectancy thanks to the protection against sudden cardiac death provided by the implantable cardioverter defibrillator (ICD). The subcutaneous ICD (S-ICD) is an effective alternative to the transvenous ICD and has evolved over the years. This study aimed to evaluate the rate of inappropriate shocks (IS), appropriate therapies, and device-related complications in patients with cardiomyopathies and channelopathies who underwent modern S-ICD implantation. METHODS AND RESULTS: We enrolled consecutive patients with cardiomyopathies and channelopathies who had undergone implantation of a modern S-ICD from January 2016 to December 2020 and who were followed up until December 2022. A total of 1338 S-ICD implantations were performed within the observation period. Of these patients, 628 had cardiomyopathies or channelopathies. The rate of IS at 12 months was 4.6% [95% confidence interval (CI): 2.8-6.9] in patients with cardiomyopathies and 1.1% (95% CI: 0.1-3.8) in patients with channelopathies (P = 0.032). No significant differences were noted over a median follow-up of 43 months [hazard ratio (HR): 0.76; 95% CI: 0.45-1.31; P = 0.351]. The rate of appropriate shocks at 12 months was 2.3% (95% CI: 1.1-4.1) in patients with cardiomyopathies and 2.1% (95% CI: 0.6-5.3) in patients with channelopathies (P = 1.0). The rate of device-related complications was 0.9% (95% CI: 0.3-2.3) and 3.2% (95% CI: 1.2-6.8), respectively (P = 0.074). No significant differences were noted over the entire follow-up. The need for pacing was low, occurring in 0.8% of patients. CONCLUSION: Modern S-ICDs may be a valuable alternative to transvenous ICDs in patients with cardiomyopathies and channelopathies. Our findings suggest that modern S-ICD therapy carries a low rate of IS. CLINICAL TRIAL REGISTRATION: URL: http://clinicaltrials.gov/Identifier: NCT02275637.


Assuntos
Cardiomiopatias , Canalopatias , Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Canalopatias/complicações , Canalopatias/terapia , Resultado do Tratamento , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Cardiomiopatias/complicações , Cardiomiopatias/terapia , Sistema de Registros
11.
Pacing Clin Electrophysiol ; 46(12): 1500-1508, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37885375

RESUMO

BACKGROUND: Remote monitoring is recommended for patients with implantable cardiac monitors (ICMs), but compared to other cardiac implantable devices, ICMs are less accurate and transmit a higher number of alerts. OBJECTIVE: The aim of this study was to investigate the predictors of false-positive (FP) arrhythmic alerts in patients with unexplained syncope who were implanted with ICM and followed by an automatic remote monitoring system. METHODS: We retrospectively evaluated all consecutive patients who received a long-sensing vector ICM for unexplained syncope between January 2019 to September 2021 at our Syncope Unit. The primary endpoint was the incidence of the first FP episode. The secondary endpoints included assessing the incidence of FP episodes for all types of algorhythms and indentifying the reasons for the misdetection of these episodes. RESULTS: Among 105 patients (44.8% males, median age 51 years), 51 (48.6%) transmitted at least one FP alert during a median follow-up of 301 days. The presence of pre-ventricular complexes (PVCs) on the resting electrocardiogram was the only clinical characteristic associated with an increased risk of FP alerts (adjusted Hazard ratio [HR] 5.76 [2.66-12.4], p = 0.010). The other significant device-related variables were a low-frequency filter at 0.05 Hz versus the default 0.5 Hz (adjusted HR 3.82 [1.38-10.5], p = 0.010) and the R-wave amplitude (adjusted HR 0.35 [0.13-0.99], p = 0.049). CONCLUSION: Patients who have PVCs are at higher risk of inappropriate ICM activations. To reduce the occurrence of FP alerts, it may be beneficial to target a large R-wave amplitude during device insertion and avoid programming a low-frequency filter at 0.05 Hz.


Assuntos
Arritmias Cardíacas , Eletrocardiografia , Masculino , Humanos , Pessoa de Meia-Idade , Feminino , Estudos Retrospectivos , Arritmias Cardíacas/diagnóstico , Arritmias Cardíacas/complicações , Síncope/diagnóstico , Síncope/etiologia , Eletrocardiografia Ambulatorial
12.
Pacing Clin Electrophysiol ; 46(10): 1258-1268, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37665040

RESUMO

BACKGROUND: Conduction system pacing (CSP), including His-bundle pacing (HBP) and left bundle branch area pacing (LBBAP), have been proposed as alternatives to biventricular pacing (BVP) in patients scheduled for ablate and pace (A&P) strategy. The aim of this study was to compare the clinical outcomes, including the rate and nature of device-related complications, between BVP and CSP in a cohort of patients undergoing A&P. METHODS: Prospective, multicenter, observational study, enrolling consecutive patients undergoing A&P. The risk of device-related complications and of heart failure (HF) hospitalization was prospectively assessed. RESULTS: A total of 373 patients (75.3 ± 8.7 years, 53.9% male, 68.9% with NYHA class ≥III) were enrolled: 263 with BVP, 68 with HBP, and 42 with LBBAP. Baseline characteristics of the three groups were similar. Compared to BVP and HBP, LBBAP was associated with the shortest mean procedural and fluoroscopy times and with the lowest acute capture thresholds (all p < .05). At 12-month follow-up LBBAP maintained the lowest capture thresholds and showed the longest estimated residual battery longevity (all p < .05). At 12-months follow-up the three study groups showed a similar risk of device-related complications (5.7%, 4.4%, and 2.4% for BVP, HBP, and LBBAP, respectively; p = .650), and of HF hospitalization (2.7%, 1.5%, and 2.4% for BVP, HBP, and LBBAP, respectively; p = .850). CONCLUSIONS: In the setting of A&P, CSP is a feasible pacing modality, with a midterm safety profile comparable to BVP. LBBAP offers the advantage of reducing procedural times and obtaining lower and stable capture thresholds, with a positive impact on the device longevity.


Assuntos
Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Humanos , Masculino , Feminino , Estudos Prospectivos , Sistema de Condução Cardíaco , Doença do Sistema de Condução Cardíaco , Fontes de Energia Elétrica , Insuficiência Cardíaca/terapia , Fascículo Atrioventricular , Resultado do Tratamento , Eletrocardiografia , Estimulação Cardíaca Artificial
13.
Medicina (Kaunas) ; 59(2)2023 Jan 28.
Artigo em Inglês | MEDLINE | ID: mdl-36837457

RESUMO

Atrial fibrillation (AF) is the most common cardiac arrhythmia associated with an increased thromboembolic risk. The impact of the female sex as an independent risk factor for thromboembolic events in AF is still debated. Background and Objectives: The aim of this review is to evaluate the gender-related differences in cardioembolic risk and response to anticoagulants among AF patients. Materials and Methods: The PubMed database is used to review the reports about gender differences and thromboembolic risk in atrial fibrillation. Results: Non-vitamin K oral anticoagulants (NOACs) represent the gold standard for thromboembolic risk prevention in patients with non-valvular atrial fibrillation (NVAF). Despite a similar rate of stroke and systemic embolism (SE) among men and women in NOACs or vitamin K antagonists (VKAs) treatment, the use of NOACs in AF women is associated with a lower risk of intracranial bleeding, major bleeding, and all-cause mortality than in men. Conclusions: The female sex can be defined as a stroke risk modifier rather than a stroke risk factor since it mainly increases the thromboembolic risk in the presence of other risk factors. Further studies about the efficacy and safety profile of NOACs according to sex are needed to support clinicians in performing the most appropriate and tailored anticoagulant therapy, either in male or female AF patients.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Tromboembolia , Feminino , Humanos , Masculino , Anticoagulantes/uso terapêutico , Fibrilação Atrial/complicações , Administração Oral , Fatores Sexuais , Acidente Vascular Cerebral/complicações , Fatores de Risco
14.
J Cardiovasc Electrophysiol ; 33(11): 2288-2296, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-35930617

RESUMO

INTRODUCTION: In patients with symptomatic permanent atrial fibrillation (PEAF) and narrow QRS, atrio-ventricular junction ablation (AVJA) plus cardiac resynchronization therapy (CRT) is superior to medical therapy in reducing heart failure (HF) hospitalization and all-cause mortality. To compare the mortality of a population of patients with HF, reduced EF (rEF), and PEAF treated with AVJA plus CRT with that of a contemporary cohort of patients in sinus rhythm (SR) with similar baseline characteristics. METHODS AND RESULTS: In this prospective, multicentre, observational study, all-cause mortality in a group of consecutive patients undergoing AVJA and implantable cardioverter-defibrillator (ICD) combined with CRT implantation for HFrEF, narrow QRS, and PEAF with uncontrolled ventricular rate was compared with that of a contemporary cohort of patients in SR undergoing ICD implantation (not combined with CRT) for HFrEF and narrow QRS. Individual 1:1 propensity matching of baseline characteristics was performed. A total of 824 patients were enrolled. Propensity matching yielded 107 matched pairs. After a median follow-up of 52 months, all-cause mortality was similar in patients treated with AVJA plus CRT and in the control group (p = .434). In AVJA plus CRT patients, mortality was significantly lower than in control group patients with a history of paroxysmal/persistent AF (n = 45, p = .020), and similar to that of patients without a history of AF (n = 62, p = .459). CONCLUSIONS: After adjustment for patient characteristics, the long-term prognosis of patients with HFrEF, narrow QRS, and PEAF who underwent AVJA plus CRT was similar to that of a population of patients in SR with similar characteristics.


Assuntos
Fibrilação Atrial , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Disfunção Ventricular Esquerda , Humanos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/etiologia , Estudos Prospectivos , Volume Sistólico , Resultado do Tratamento , Disfunção Ventricular Esquerda/terapia
15.
J Cardiovasc Pharmacol ; 79(4): 472-478, 2022 04 01.
Artigo em Inglês | MEDLINE | ID: mdl-34935699

RESUMO

ABSTRACT: No data on the add-on sacubitril/valsartan (S/V) therapy among cardiac resynchronization therapy with a defibrillator (CRT-D) nonresponder patients are currently available in literature. We conducted a prospective observational study including 190 CRT-D nonresponder patients with symptomatic heart failure with reduced ejection fraction despite the optimal medical therapy from at least 1 year. The primary endpoint was the rate of additional responders (left ventricular end-systolic volume reduction >15%) at 12 months from the introduction of S/V therapy. At the end of the 12 months follow-up, 37 patients (19.5%) were deemed as "additional responders" to the combination use of CRT + S/V therapy. The only clinical predictor of additional response was a lower left ventricular ejection fraction [OR 0.881 (0.815-0.953), P = 0.002] at baseline. At 12 months follow-up, there were significant improvements in heart failure (HF) symptoms and functional status [New York Heart Association 2 (2-3) vs. 1 (1-2), P < 0.001; physical activity duration/day: 10 (8-12) vs. 13 (10-18) hours, P < 0.001]. Compared with the 12 months preceding S/V introduction, there were significant reductions in the rate of HF rehospitalization (35.5% vs. 19.5%, P < 0.001), in atrial tachycardia/atrial fibrillation burden [6.0 (5.0-8.0) % vs. 0 (0-2.0) %, P < 0.001] and in the proportions of patients experiencing ventricular arrhythmias (21.6% vs. 6.3%; P < 0.001). Our results indicate that S/V add-on therapy in CRT-D nonresponder patients is associated with 19.5% of additional responders, a reduction in HF symptoms and rehospitalizations, AF burden, and ventricular arrhythmias.


Assuntos
Fibrilação Atrial , Terapia de Ressincronização Cardíaca , Insuficiência Cardíaca , Aminobutiratos , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/tratamento farmacológico , Compostos de Bifenilo , Terapia de Ressincronização Cardíaca/efeitos adversos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/tratamento farmacológico , Humanos , Volume Sistólico , Resultado do Tratamento , Valsartana/efeitos adversos , Função Ventricular Esquerda
16.
Europace ; 24(7): 1148-1155, 2022 07 21.
Artigo em Inglês | MEDLINE | ID: mdl-35861549

RESUMO

AIMS: Myotonic dystrophy type 1 (DM1) predisposes to the development of life-threatening arrhythmias and sudden cardiac death. Our study aimed to evaluate the prognostic value of programmed ventricular stimulation (PVS) in DM1 patients with conduction system disease. METHODS AND RESULTS: Arrhythmic CArdiac DEath in MYotonic dystrophy type 1 patients (ACADEMY 1) is a double-arm non-randomized interventional prospective study. Myotonic dystrophy type 1 patients with permanent cardiac pacing indication were eligible for the inclusion. The study population underwent to pacemaker (PM) or implantable cardioverter-defibrillator (ICD) implantation according to the inducibility of ventricular tachyarrhythmias at PVS. Primary endpoint of the study was a composite of appropriate ICD therapy and cardiac arrhythmic death. The secondary study endpoint was all-cause mortality. Seventy-two adult-onset DM1 patients (51 ± 12 years; 39 male) were enrolled in the study. A ventricular tachyarrhythmia was induced in 25 patients (34.7%) at PVS (PVS+) who underwent dual chambers ICD implantation. The remaining 47 patients (65.3%) without inducible ventricular tachyarrhythmia (PVS-) were treated with dual-chamber PM. During an average observation period of 44.7 ± 10.2 months, nine patients (12.5%) met the primary endpoint, four in the ICD group (16%) and five (10.6%) in the PM group. Thirteen patients died (18.5%), 2 in the ICD group (8%) and 11 in PM group (23.4%). The Kaplan-Meier analysis did not show a significantly different risk of both primary and secondary endpoint event rates between the two groups. CONCLUSIONS: The inducibility of ventricular tachyarrhythmias has shown a limited value in the arrhythmic risk stratification among DM1 patients.


Assuntos
Desfibriladores Implantáveis , Distrofia Miotônica , Taquicardia Ventricular , Adulto , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/prevenção & controle , Desfibriladores Implantáveis/efeitos adversos , Humanos , Masculino , Distrofia Miotônica/complicações , Distrofia Miotônica/diagnóstico , Distrofia Miotônica/terapia , Estudos Prospectivos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/terapia
17.
Cardiovasc Drugs Ther ; 36(4): 705-712, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-33988835

RESUMO

PURPOSE: The clinical course of COVID-19 may be complicated by acute respiratory distress syndrome (ARDS) and thromboembolic events, which are associated with high risk of mortality. Although previous studies reported a lower rate of death in patients treated with heparin, the potential benefit of chronic oral anticoagulation therapy (OAT) remains unknown. We aimed to investigate the association between OAT with the risk of ARDS and mortality in hospitalized patients with COVID-19. METHODS: This is a multicenter retrospective Italian study including consecutive patients hospitalized for COVID-19 from March 1 to April 22, 2020, at six Italian hospitals. Patients were divided into two groups according to the chronic assumption of oral anticoagulants. RESULTS: Overall, 427 patients were included; 87 patients (19%) were in the OAT group. Of them, 54 patients (13%) were on treatment with non-vitamin k oral anticoagulants (NOACs) and 33 (8%) with vitamin-K antagonists (VKAs). OAT patients were older and had a higher rate of hypertension, diabetes, and coronary artery disease compared to No-OAT group. The rate of ARDS at admission (26% vs 28%, P=0.834), or developed during the hospitalization (9% vs 10%, P=0.915), was similar between study groups; in-hospital mortality (22% vs 26%, P=0.395) was also comparable. After balancing for potential confounders by using the propensity score matching technique, no differences were found in term of clinical outcome between OAT and No-OAT patients CONCLUSION: Oral anticoagulation therapy, either NOACs or VKAs, did not influence the risk of ARDS or death in patients hospitalized with COVID-19.


Assuntos
Fibrilação Atrial , COVID-19 , Síndrome do Desconforto Respiratório , Administração Oral , Anticoagulantes , Fibrilação Atrial/tratamento farmacológico , Fibrinolíticos/uso terapêutico , Humanos , Estudos Retrospectivos , Vitamina K
18.
Eur J Clin Pharmacol ; 78(5): 879-886, 2022 May.
Artigo em Inglês | MEDLINE | ID: mdl-35138442

RESUMO

PURPOSE: Older age is associated with inappropriate dose prescription of direct oral anticoagulants. The aim of our study was to describe the prevalence and the clinical predictors of inappropriate DOACs dosage among octogenarians in real-world setting. METHODS: Data for this study were sourced from the multicenter prospectively maintained Atrial Fibrillation (AF) Research Database (NCT03760874). Of the AF patients aged ≥ 80 who received DOACs treatment, 253 patients were selected. Participants were categorized as appropriate dosage, overdosage, or underdosage. Underdosage and overdosage were, respectively, defined as administration of a lower or higher DOAC dose than recommended in the EHRA consensus. RESULTS: A total of 178 patients (71%) received appropriate DOACs dose and 75 patients (29%) inappropriate DOACs dose; among them, 19 patients (25.6%) were overdosed and 56 (74.4%) were underdosed. Subgroup analysis demonstrated that underdosage was independently associated with male gender [OR = 3.15 (95% IC; 1.45-6.83); p < 0.001], coronary artery disease [OR = 3.60 (95% IC 1.45-9.10); p < 0.001] and body mass index [OR = 1.27 (1.14-1.41); p < 0.001]. Overdosage was independently associated with diabetes mellitus [OR = 18 (3.36-96); p < 0.001], with age [OR = 0.76 (95% IC; 0.61-0.96; p = 0.045], BMI [OR = 0.77 (95% IC; 0.62-0.97; p = 0.043] and with previous bleedings [OR = 6.40 (0.7; 1.43-28); p = 0.039]. There wasn't significant difference in thromboembolic, major bleeding events and mortality among different subgroups. Underdosage group showed a significatively lower survival compared with appropriate dose group (p < 0.001). CONCLUSION: In our analysis, nearly one-third of octogenarians with AF received an inappropriate dose of DOAC. Several clinical factors were associated with DOACs' overdosage (diabetes mellitus type II, previous bleeding) or underdosage (male gender, coronary artery disease, and higher body mass index). Octogenarians with inappropriate DOACs underdosage showed less survival.


Assuntos
Fibrilação Atrial , Doença da Artéria Coronariana , Acidente Vascular Cerebral , Administração Oral , Idoso de 80 Anos ou mais , Anticoagulantes , Fibrilação Atrial/complicações , Doença da Artéria Coronariana/tratamento farmacológico , Hemorragia/induzido quimicamente , Hemorragia/epidemiologia , Humanos , Masculino , Prevalência , Fatores de Risco , Acidente Vascular Cerebral/tratamento farmacológico
19.
Pacing Clin Electrophysiol ; 45(10): 1210-1215, 2022 10.
Artigo em Inglês | MEDLINE | ID: mdl-35983947

RESUMO

BACKGROUND: Air entrapment has been recently described as a cause of inappropriate shock (IAS) among patients who underwent subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation. Data about this complication are lacking in the literature. METHODS: In this meta-summary 14 case reports describing IAS due to air entrapment were included. Patients' characteristics, S-ICD implant technique and air entrapment properties were collected. RESULTS: All patients experienced IAS within 4 days following S-ICD implant. The subcutaneous air was demonstrated by chest x-ray in 11 cases (73.3%). The sensing vector was reprogrammed in 11 cases (73.3%), and ICD was switched off in 2 cases (1.3%). CONCLUSIONS: IAS due to air entrapment is an early complication of S-ICD implant. No association was observed between the implant technique and air retention. Diagnosis is confirmed by chest x-ray and device interrogation. Management includes switching off the device or, preferably, changing the sensing vector.


Assuntos
Desfibriladores Implantáveis , Humanos , Desfibriladores Implantáveis/efeitos adversos , Resultado do Tratamento , Fatores de Risco
20.
Pacing Clin Electrophysiol ; 45(5): 612-618, 2022 05.
Artigo em Inglês | MEDLINE | ID: mdl-35383979

RESUMO

BACKGROUND: Although radiofrequency (RF) catheter ablation of cavo-tricuspid isthmus (CTI) is an established treatment for typical right atrial flutter (RAFL), it remains to be established whether local tissue impedance (LI) is able to predict effective CTI ablation and what LI drop values during ablation should be used to judge a lesion as effective. We aimed to investigate the ability of LI to predict ablation efficacy in patients with RAFL. METHODS: RF delivery was guided by the DirectSense™ algorithm. Successful single RF application was defined according to a defragmentation of atrial potentials (DAP), reduction of voltage (RedV) by at least 80% or changes on unipolar electrogram (UPC). The ablation endpoint was the creation of bidirectional conduction block (BDB) across the isthmus. RESULTS: 392 point-by-point RF applications were analyzed in 48 consecutive RAFL patients. The mean baseline LI was 105.4 ± 12Ω prior to ablation and 92.0 ± 11Ω after ablation (p < 0.0001). According to validation criteria, absolute drops in impedance were larger at successful ablation sites than at ineffective ablation sites (DAP: 17.8 ± 6Ω vs. 8.7 ± 4Ω; RedV: 17.2 ± 6Ω vs. 7.8 ± 5Ω; UPC: 19.6 ± 6Ω vs. 10.1 ± 5Ω, all p < 0.0001). LI drop values significantly increased according to the number of criteria satisfied (ranging from 7.5Ω to 19.9). BDB was obtained in all cases. No procedure-related adverse events were reported. CONCLUSIONS: A LI-guided approach to CTI ablation was safe and effective in treating RAFL. The magnitude of LI drop was associated with effective lesion formation and BDB and could be used as a marker of ablation efficacy. CLINICAL TRIAL REGISTRATION: Catheter Ablation of Arrhythmias with a High-Density Mapping System in Real-World Practice (CHARISMA). URL: http://clinicaltrials.gov/ Identifier: NCT03793998.


Assuntos
Flutter Atrial , Ablação por Cateter , Ablação por Cateter/efeitos adversos , Impedância Elétrica , Bloqueio Cardíaco/etiologia , Humanos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA