Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Zhongguo Yi Liao Qi Xie Za Zhi ; 46(3): 292-295, 2022 May 30.
Artigo em Zh | MEDLINE | ID: mdl-35678439

RESUMO

The treatment of refractory Glaucoma is a difficult problem in clinical ophthalmology. For refractory glaucoma patients with hyphema, shallow anterior chamber, anterior conglutination of peripheral chamber angle, corneal endothelium dystrophy or decompensated, at present, there is no effective treatment. In order to solve this problem, a new type posterior integral glaucoma valve with IOP control device was designed using medical titanium alloy, and the valve model was established by Abaqus software, and the stiffness and preload of the valve were analyzed by finite element method. The results showed that the opening and closing of the valve were controlled automatically by the pressure difference between the front and back of the valve, and the opening and flow rate of the valve increase dynamically with the increase of intraocular pressure, and finally reached the set ideal IOP value of steady state.


Assuntos
Implantes para Drenagem de Glaucoma , Glaucoma , Análise de Elementos Finitos , Seguimentos , Humanos , Pressão Intraocular , Resultado do Tratamento
2.
Int J Ophthalmol ; 15(9): 1483-1487, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-36124197

RESUMO

AIM: To assess the reproducibility of macular perfusion parameters in non-proliferative diabetic retinopathy (NPDR) patients measured by different examiners and two different sweep modes of optical coherence tomography angiography (OCTA). METHODS: Ninety-eight (98 eyes) patients with NPDR were included in this study. All participates were performed three times using Cirrus OCTA with Angiography 3×3 mm2 and 6×6 mm2 sweep mode by two examiners. The macular foveal avascular zone (FAZ) and vessel density (VD) in the superficial retinal layer (SRL) were measured. The reproducibility of the measurements was evaluated with intraclass correlation coefficients (ICC) and coefficient of variation (CoV). RESULTS: The intra-mode ICCs of Angiography 3×3 mm2 and 6×6 mm2 sweep mode were 0.957 to 0.959 and 0.964 to 0.977, respectively; and the inter-mode ICCs were 0.962 to 0.970. The intra-examiner ICCs of macular perfusion parameters were >0.950; and the inter-examiner ICCs were 0.928 to 0.969. All CoVs were <1.0%. CONCLUSION: Cirrus OCTA can measure macular perfusion parameters in NPDR patients with excellent reproducibility. The measurements of FAZ and VD in the SRL determined by Angiography 3×3 mm2 and 6×6 mm2 sweep mode are highly consistent and both sweep modes are suitable for macular perfusion parameters measurement.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA