Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
J Pediatr Ophthalmol Strabismus ; 27(5): 242-4, 1990.
Artigo em Inglês | MEDLINE | ID: mdl-2246736

RESUMO

Although chloral hydrate sedation has been proposed as an alternative to evaluation under anesthesia for pediatric patients who are unable to cooperate with routine test procedures, a careful study of the drug's safety and effectiveness is lacking. This study reports the effectiveness and safety of high-dose chloral hydrate for ophthalmic examination in 302 patients between the ages of 1 month and 5 years. The patients had nothing to eat or drink for 4 hours prior to drug administration. The patients were monitored during sedation and until fully awake. Eighty-eight percent of the patients (266/302) were successfully sedated without a supplemental dose. There were no reports of any complications including emesis, respiratory distress or depression, behavioral problems, changes in vital signs, patient injury, or hospital admission. The high-dose chloral hydrate protocol described, results in safe and generally successful sedation of pediatric patients for ophthalmic examination.


Assuntos
Hidrato de Cloral/administração & dosagem , Testes Visuais , Pré-Escolar , Hidrato de Cloral/efeitos adversos , Relação Dose-Resposta a Droga , Eletrofisiologia , Oftalmopatias/diagnóstico , Humanos , Lactente , Recém-Nascido , Estudos Retrospectivos , Suturas
2.
Ophthalmic Surg Lasers ; 27(1): 66-9, 1996 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-8630756

RESUMO

BACKGROUND AND OBJECTIVE: The minimal scleral flap thickness to ensure transscleral flow following a trabeculectomy has never been determined. The present study was designed to determine, in vitro, the critical scleral flap thickness that allows transscleral flow. MATERIALS AND METHODS: The apparatus consisted of two horizontal glass chambers (A and B) connected to each other by a customized scleral disc holder. High-pressure chamber A (at 25 mm Hg) was filled with sodium pertechnetate (99mTc) labeled normal saline and low-pressure chamber B (at 5 mm Hg) with normal saline. Transscleral flow of labeled normal saline from high-pressure chamber A via varying thickness scleral discs to low-pressure chamber B was observed over 16 hours using a gamma camera. Computer analysis was performed on the obtained images. RESULTS: Transscleral flow of labeled saline was observed only with scleral discs 0.5 mm thick or less. CONCLUSIONS: If the findings hold true for the in vivo situation, aqueous humor may reach the subconjunctival space following trabeculectomy via the transscleral route, provided scleral flap thickness is less than 0.5 mm. In addition, normal uveoscleral aqueous outflow may occur across sclera less than 0.5 mm thick, e.g., posterior to extraocular muscle insertions.


Assuntos
Humor Aquoso/fisiologia , Esclera/fisiologia , Cadáver , Desenho de Equipamento , Câmaras gama , Humanos , Processamento de Imagem Assistida por Computador , Projetos Piloto , Tecnécio
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA