Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 239
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
J Clin Monit Comput ; 37(2): 345-350, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36125636

RESUMO

In this article we present the learning from a clinical study of airway device evaluation, conducted under the framework of the Difficult Airway Society (DAS, UK) 'ADEPT' (airway device evaluation project team) strategy. We recommend a change in emphasis from small scale randomised controlled trials conducted as research, to larger-scale observational, post-marketing evaluation audits as a way of obtaining more meaningful information.

2.
J Clin Monit Comput ; 37(2): 517-524, 2023 04.
Artigo em Inglês | MEDLINE | ID: mdl-36063277

RESUMO

To address the problem of lack of clinical evidence for airway devices introduced to the market, the Difficult Airway Society (UK) developed an approach (termed ADEPT; Airway Device Evaluation Project Team) to standardise the model for device evaluation. Under this framework we assessed the LMA Protector, a second generation laryngeal mask airway. A total of 111 sequential adult patients were recruited and the LMA Protector inserted after induction of general anaesthesia. Effective insertion was confirmed by resistance to further distal movement, manual ventilation, and listening for gas leakage at the mouth. The breathing circuit was connected to the airway channel and airway patency confirmed with manual test ventilation at 20 cm H20 (water) pressure for 3 s. Data was collected in relation to the time for placement, intraoperative performance and postoperative performance of the airway device. Additionally, investigators rated the ease of insertion and adequacy of lung ventilation on a 5-point scale. The median (interquartile range [range]) time taken to insertion of the device was 31 (26-40[14-780]) s with the ability to ventilate after device insertion 100 (95% CI 96.7- 100)%. Secondary endpoints included one or more manoeuvres 60.3 (95% CI 50.6-69.5)% cases requiring to assist insertion; a median ease of insertion score of 4 (2-5[3-5]), and a median adequacy of ventilation score of 5 (5-5[4-5]). However, the first time insertion rate failure was 9.9% (95% CI 5.1-17.0%). There were no episodes of patient harm recorded, particularly desaturation. The LMA Protector appears suitable for clinical use, but an accompanying article discusses our reflections on the ADEPT approach to studying airway devices from a strategic perspective.


Assuntos
Máscaras Laríngeas , Adulto , Humanos , Intubação Intratraqueal , Respiração Artificial , Movimento , Boca
3.
Anaesthesia ; 77(12): 1395-1415, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-35977431

RESUMO

Across multiple disciplines undertaking airway management globally, preventable episodes of unrecognised oesophageal intubation result in profound hypoxaemia, brain injury and death. These events occur in the hands of both inexperienced and experienced practitioners. Current evidence shows that unrecognised oesophageal intubation occurs sufficiently frequently to be a major concern and to merit a co-ordinated approach to address it. Harm from unrecognised oesophageal intubation is avoidable through reducing the rate of oesophageal intubation, combined with prompt detection and immediate action when it occurs. The detection of 'sustained exhaled carbon dioxide' using waveform capnography is the mainstay for excluding oesophageal placement of an intended tracheal tube. Tube removal should be the default response when sustained exhaled carbon dioxide cannot be detected. If default tube removal is considered dangerous, urgent exclusion of oesophageal intubation using valid alternative techniques is indicated, in parallel with evaluation of other causes of inability to detect carbon dioxide. The tube should be removed if timely restoration of sustained exhaled carbon dioxide cannot be achieved. In addition to technical interventions, strategies are required to address cognitive biases and the deterioration of individual and team performance in stressful situations, to which all practitioners are vulnerable. These guidelines provide recommendations for preventing unrecognised oesophageal intubation that are relevant to all airway practitioners independent of geography, clinical location, discipline or patient type.


Assuntos
Dióxido de Carbono , Intubação Intratraqueal , Humanos , Intubação Intratraqueal/métodos , Capnografia , Esôfago , Manuseio das Vias Aéreas
4.
Anaesthesia ; 76(2): 251-260, 2021 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-32839960

RESUMO

It is now apparent that severe acute respiratory syndrome coronavirus-2 (SARS-CoV-2) and coronavirus disease 2019 (COVID-19) will remain endemic for some time. Improved therapeutics and a vaccine may shorten this period, but both are far from certain. Plans must be put in place on the assumption that the virus and its disease will continue to affect the care of patients and the safety of staff. This will impact particularly on airway management due to the inherent risk to staff during such procedures. Research is needed to clarify the nature and risk of respiratory aerosol-generating procedures. Improved knowledge of the dynamics of SARS-CoV-2 infection and immunity is also required. In the meantime, we describe the current status of airway management during the endemic phase of the COVID-19 pandemic. Some controversies remain unresolved, but the safety of patients and staff remains paramount. Current evidence does not support or necessitate dramatic changes to choices for anaesthetic airway management. Theatre efficiency and training issues are a challenge that must be addressed, and new information may enable this.


Assuntos
Manuseio das Vias Aéreas/métodos , COVID-19 , Pandemias , Anestesia , Humanos , Controle de Infecções , Salas Cirúrgicas/organização & administração , Equipamento de Proteção Individual
5.
Diabet Med ; 37(12): 2044-2049, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-30710451

RESUMO

AIMS: The purpose of this study was to identify the number of pregnancies affected by pre-gestational diabetes in the Republic of Ireland; to report on pregnancy outcomes and to identify areas for improvement in care delivery and clinical outcomes. METHODS: Healthcare professionals caring for women with pre-gestational diabetes during pregnancy were invited to participate in this retrospective study. Data pertaining to 185 pregnancies in women attending 15 antenatal centres nationally were collected and analysed. Included pregnancies had an estimated date of delivery between 1 January and 31 December 2015. RESULTS: The cohort consisted of 122 (65.9%) women with Type 1 diabetes and 56 (30.3%) women with Type 2 diabetes. The remaining 7 (3.8%) pregnancies were to women with maturity-onset diabetes of the young (MODY) (n = 6) and post-transplant diabetes (n = 1). Overall women were poorly prepared for pregnancy and lapses in specific areas of service delivery including pre-pregnancy care and retinal screening were identified. The majority of pregnancies 156 (84.3%) resulted in a live birth. A total of 103 (65.5%) women had a caesarean delivery and 58 (36.9%) infants were large for gestational age. CONCLUSIONS: This audit identifies clear areas for improvement in delivery of care for women with diabetes in the Republic of Ireland before and during pregnancy.


Assuntos
Diabetes Mellitus Tipo 1/tratamento farmacológico , Diabetes Mellitus Tipo 2/terapia , Cuidado Pré-Concepcional/estatística & dados numéricos , Resultado da Gravidez/epidemiologia , Gravidez em Diabéticas/terapia , Aborto Espontâneo/epidemiologia , Adulto , Aspirina/uso terapêutico , Cesárea , Auditoria Clínica , Atenção à Saúde , Parto Obstétrico , Diabetes Mellitus Tipo 1/metabolismo , Diabetes Mellitus Tipo 2/metabolismo , Retinopatia Diabética/diagnóstico , Feminino , Macrossomia Fetal/epidemiologia , Ácido Fólico/uso terapêutico , Hemoglobinas Glicadas/metabolismo , Humanos , Hipoglicemiantes/uso terapêutico , Recém-Nascido , Bombas de Infusão Implantáveis , Insulina/uso terapêutico , Sistemas de Infusão de Insulina , Unidades de Terapia Intensiva Neonatal/estatística & dados numéricos , Irlanda/epidemiologia , Nascido Vivo/epidemiologia , Programas de Rastreamento , Metformina/uso terapêutico , Inibidores da Agregação Plaquetária/uso terapêutico , Gravidez , Nascimento Prematuro/epidemiologia , Estudos Retrospectivos , Natimorto/epidemiologia , Complexo Vitamínico B/uso terapêutico
6.
Anaesthesia ; 75(4): 509-528, 2020 04.
Artigo em Inglês | MEDLINE | ID: mdl-31729018

RESUMO

Awake tracheal intubation has a high success rate and a favourable safety profile but is underused in cases of anticipated difficult airway management. These guidelines are a comprehensive document to support decision making, preparation and practical performance of awake tracheal intubation. We performed a systematic review of the literature seeking all of the available evidence for each element of awake tracheal intubation in order to make recommendations. In the absence of high-quality evidence, expert consensus and a Delphi study were used to formulate recommendations. We highlight key areas of awake tracheal intubation in which specific recommendations were made, which included: indications; procedural setup; checklists; oxygenation; airway topicalisation; sedation; verification of tracheal tube position; complications; management of unsuccessful awake tracheal intubation; post-tracheal intubation management; consent; and training. We recognise that there are a range of techniques and regimens that may be effective and one such example technique is included. Breaking down the key practical elements of awake tracheal intubation into sedation, topicalisation, oxygenation and performance might help practitioners to plan, perform and address complications. These guidelines aim to support clinical practice and help lower the threshold for performing awake tracheal intubation when indicated.


Assuntos
Intubação Intratraqueal/métodos , Intubação Intratraqueal/normas , Adulto , Humanos , Sociedades Médicas , Vigília
7.
Anaesthesia ; 75(12): 1671-1682, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33165958

RESUMO

Multiple professional groups and societies worldwide have produced airway management guidelines. These are typically targeted at the process of tracheal intubation by a particular provider group in a restricted category of patients and reflect practice preferences in a particular geographical region. The existence of multiple distinct guidelines for some (but not other) closely related circumstances, increases complexity and may obscure the underlying principles that are common to all of them. This has the potential to increase cognitive load; promote the grouping of ideas in silos; impair teamwork; and ultimately compromise patient care. Development of a single set of airway management guidelines that can be applied across and beyond these domains may improve implementation; promote standardisation; and facilitate collaboration between airway practitioners from diverse backgrounds. A global multidisciplinary group of both airway operators and assistants was assembled. Over a 3-year period, a review of the existing airway guidelines and multiple reviews of the primary literature were combined with a structured process for determining expert consensus. Any discrepancies between these were analysed and reconciled. Where evidence in the literature was lacking, recommendations were made by expert consensus. Using the above process, a set of evidence-based airway management guidelines was developed in consultation with airway practitioners from a broad spectrum of disciplines and geographical locations. While consistent with the recommendations of the existing English language guidelines, these universal guidelines also incorporate the most recent concepts in airway management as well as statements on areas not widely addressed by the existing guidelines. The recommendations will be published in four parts that respectively address: airway evaluation; airway strategy; airway rescue and communication of airway outcomes. Together, these universal guidelines will provide a single, comprehensive approach to airway management that can be consistently applied by airway practitioners globally, independent of their clinical background or the circumstances in which airway management occurs.


Assuntos
Manuseio das Vias Aéreas/métodos , Guias de Prática Clínica como Assunto , Humanos
8.
Anaesthesia ; 75(11): 1437-1447, 2020 11.
Artigo em Inglês | MEDLINE | ID: mdl-32516833

RESUMO

Healthcare workers involved in aerosol-generating procedures, such as tracheal intubation, may be at elevated risk of acquiring COVID-19. However, the magnitude of this risk is unknown. We conducted a prospective international multicentre cohort study recruiting healthcare workers participating in tracheal intubation of patients with suspected or confirmed COVID-19. Information on tracheal intubation episodes, personal protective equipment use and subsequent provider health status was collected via self-reporting. The primary endpoint was the incidence of laboratory-confirmed COVID-19 diagnosis or new symptoms requiring self-isolation or hospitalisation after a tracheal intubation episode. Cox regression analysis examined associations between the primary endpoint and healthcare worker characteristics, procedure-related factors and personal protective equipment use. Between 23 March and 2 June 2020, 1718 healthcare workers from 503 hospitals in 17 countries reported 5148 tracheal intubation episodes. The overall incidence of the primary endpoint was 10.7% over a median (IQR [range]) follow-up of 32 (18-48 [0-116]) days. The cumulative incidence within 7, 14 and 21 days of the first tracheal intubation episode was 3.6%, 6.1% and 8.5%, respectively. The risk of the primary endpoint varied by country and was higher in women, but was not associated with other factors. Around 1 in 10 healthcare workers involved in tracheal intubation of patients with suspected or confirmed COVID-19 subsequently reported a COVID-19 outcome. This has human resource implications for institutional capacity to deliver essential healthcare services, and wider societal implications for COVID-19 transmission.


Assuntos
Betacoronavirus , Infecções por Coronavirus/transmissão , Pessoal de Saúde , Intubação Intratraqueal , Exposição Ocupacional/efeitos adversos , Pneumonia Viral/transmissão , Adulto , COVID-19 , Infecções por Coronavirus/epidemiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pandemias , Pneumonia Viral/epidemiologia , Modelos de Riscos Proporcionais , Estudos Prospectivos , Risco , SARS-CoV-2
9.
BJOG ; 126(4): 514-524, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30303614

RESUMO

OBJECTIVE: To determine whether a dietary intervention in pregnancy had a lasting effect on maternal outcomes of diet, HbA1c and weight retention 5 years post-intervention; and to establish whether modifiable maternal behaviours were associated with these outcomes. DESIGN: Randomised control trial of low glycaemic index (GI) diet in pregnancy with longitudinal follow up to 5 years post-intervention. SETTING: Dublin, Ireland (2007-2016). POPULATION: In all, 403 women of 759 (53.1%) were followed up at 5 years. A total of 370 (intervention n = 188; control n = 182) were included in this analysis. METHODS: Fasting glucose was measured at 13 and 28 weeks' gestation and HbA1c (mmol/mol) at 5-year follow up. Weight retention (kg) from early pregnancy to 5 years post-intervention was calculated. Dietary intakes, anthropometry, and lifestyle factors were measured in pregnancy and 5 years post-intervention. Multiple linear regression models, controlling for confounders, were used for analysis. OUTCOME: Maternal diet, HbA1c, and weight retention at 5 years post-intervention. RESULTS: There was no difference between the intervention and control at 5 years post-intervention for any long-term maternal outcomes measured. HbA1c at 5 years post-intervention was associated with early-pregnancy fasting glucose (B 1.70, 95% CI 0.36-3.04) and parity ≥3 (B 1.04, 95% CI 0.09-1.99). Weight retention was associated with change in well-being from pregnancy to 5 years (B -0.06, 95% CI -0.11 to -0.02), gestational weight gain (B 0.19, 95% CI 0.00-0.38), and GI (B 0.26, 95% CI 0.06-0.46) at 5 years. CONCLUSIONS: The ROLO low-GI dietary intervention in pregnancy had no impact on maternal dietary intakes, HbA1c or body composition 5 years post-intervention. Maternal factors and lifestyle behaviours in pregnancy have long-term effects on glucose metabolism and weight retention up to 5 years later. TWEETABLE ABSTRACT: Pregnancy factors are associated with maternal glucose metabolism and weight retention 5 years later-findings from the ROLO Study.


Assuntos
Dieta/métodos , Índice Glicêmico , Período Pós-Parto/sangue , Complicações na Gravidez/dietoterapia , Adulto , Glicemia/metabolismo , Jejum/sangue , Feminino , Seguimentos , Ganho de Peso na Gestação , Hemoglobinas Glicadas/metabolismo , Humanos , Modelos Lineares , Estudos Longitudinais , Fenômenos Fisiológicos da Nutrição Materna , Gravidez , Complicações na Gravidez/sangue , Tempo , Fatores de Tempo
11.
Anaesthesia ; 74(2): 158-166, 2019 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-30255496

RESUMO

The Lancet Commission on Global Surgery emphasised the importance of access to safe anaesthesia care. Capnography is an essential monitor for safe anaesthesia, but is rarely available in low-income countries. The aim of this study was twofold: to measure the prevalence of capnography in the operating theatres and in intensive care units; and to determine whether its introduction was feasible and could improve the early recognition of critical airway incidents in a low-income country. This is the first project to do this. Forty capnographs were donated to eight hospitals in Malawi. Thirty-two anaesthesia providers received a 1-day capnography training course with pre- and post-course knowledge testing. Providers kept logbooks of capnography use and recorded their responses to abnormal readings. On follow-up at 6 months, providers completed questionnaires on any significant patient safety incidents identified using capnography. In January 2017, at the commencement of the project, only one operating theatre had a capnograph. Overall, 97% and 100% 'capnography gaps' were identified in the theatres and intensive care units, respectively. The mean (SD) scores of our capnography multiple choice questionnaires improved after training from 15.00 (3.16) to 18.70 (0.99), p = < 0.001. The capnography equipment was appropriately robust and performed well. Six months following implementation, 24 (77%) anaesthesia providers reported recognising 44 oesophageal intubations and 28 (90%) believed that capnography had saved lives. This study has shown it is feasible to introduce capnography in a low-income country, resulting in early recognition of critical airway incidents and ultimately helping to save lives. Building on the experience of the first trial of pulse oximetry implementation in low-income countries in 2007, we believe this is one of the most important projects in anaesthesia safety in the last decade.


Assuntos
Capnografia/normas , Melhoria de Qualidade , Adulto , Países em Desenvolvimento , Feminino , Humanos , Malaui , Masculino , Segurança do Paciente
12.
Ir Med J ; 112(1): 853, 2019 01 15.
Artigo em Inglês | MEDLINE | ID: mdl-30719894

RESUMO

Aims This paper examines admissions for the last ten years for those recorded as of no fixed abode (NFA) on the National Psychiatric In-Patient Reporting System (NPIRS). Methods The Health Research Board's (HRB) NPIRS data were analysed using SPSS to develop an overview of admissions with NFA recorded for the years 2007-2016 (n=2,176). Results In the period 2007-2016 there were 2,176 admissions with NFA recorded. In that 10-year period there was a 44% increase in admissions with NFA from 188 in 2007 to 271 in 2016. The analysis shows that the characteristics of this cohort have remained largely unchanged in the 10 years; almost three-quarters (1,598; 73.4%) were male, almost half (1,068; 49.1%) were less than 35 years of age and three-quarters (1,638; 75.2%) were less than 45 years. Three-quarters (1,643; 75.5%) were single and a similar proportion was unemployed (1,640; 75.4%). In addition, the highest proportion had a diagnosis of schizophrenia (621; 28.5%) followed by drugs/alcohol disorders (590; 27.1%). These characteristics are consistent with the single 'chronically homeless' people described in the literature. Discussion The paper concludes the need to use routinely collected data to help understand and address the need of specific homeless sub-groups particularly those on institutional circuits that include psychiatric in-patient facilities. To enable this it recommends the implementation of the individual health identifier as a matter of urgency.


Assuntos
Transtornos Mentais/epidemiologia , Admissão do Paciente/estatística & dados numéricos , Adulto , Fatores Etários , Alcoolismo/epidemiologia , Feminino , Pessoas Mal Alojadas/estatística & dados numéricos , Humanos , Irlanda/epidemiologia , Masculino , Pessoa de Meia-Idade , Esquizofrenia/epidemiologia , Fatores Sexuais , Transtornos Relacionados ao Uso de Substâncias/epidemiologia , Fatores de Tempo
14.
Anaesthesia ; 73(6): 703-710, 2018 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-29533465

RESUMO

In this exploratory study we describe the utility of smartphone technology for anonymous retrospective observational data collection of emergency front-of-neck airway management. The medical community continues to debate the optimal technique for emergency front-of-neck airway management. Although individual clinicians infrequently perform this procedure, hundreds are performed annually worldwide. Ubiquitous smartphone technology and internet connectivity have created the opportunity to collect these data. We created the 'Airway App', a smartphone application to capture the experiences of healthcare providers involved in emergency front-of-neck airway procedures. In the first 18-month period, 104 emergency front-of-neck airway management reports were received; 99 (95%) were internally valid and unique from 21 countries. Eighty-one (82%) were performed by non-surgeons and 63 (64%) were 'cannot intubate, cannot oxygenate' emergencies. Overall first-attempt success varied by technique; 45 scalpel-bougie cricothyroidotomy (37 first-attempt success), 25 surgical cricothyroidotomy (15 first-attempt success), eight cannula cricothyroidotomy (five first-attempt success), six wire-guided cricothyroidotomy (three first-attempt success) and 15 tracheostomy reports (11 first-attempt success). The most commonly reported positive human factors were good communication, good teamwork and/or skilled personnel. The most commonly reported negative human factors were fixation on multiple tracheal intubation attempts, delay in initiating emergency front-of-neck airway and/or the failure to plan for failure. Due to the anonymous nature of reporting, reports are open to recollection bias and spurious reporting. We conclude collection of data using a smartphone application is feasible and has the potential to expand our knowledge of emergency front-of-neck airway management.


Assuntos
Manuseio das Vias Aéreas/métodos , Aplicativos Móveis , Pescoço/cirurgia , Smartphone , Adulto , Idoso , Idoso de 80 Anos ou mais , Competência Clínica , Comunicação , Cartilagem Cricoide/cirurgia , Coleta de Dados , Serviços Médicos de Emergência , Feminino , Humanos , Intubação Intratraqueal , Masculino , Pessoa de Meia-Idade , Equipe de Assistência ao Paciente , Gravidez , Estudos Retrospectivos , Inquéritos e Questionários , Traqueostomia , Traqueotomia/estatística & dados numéricos
15.
Eur J Cancer Care (Engl) ; 27(2): e12520, 2018 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-27271027

RESUMO

The purpose of this study was to quantify the general cancer support activities that long-term carers of head and neck cancer (HNC) survivors engage in; and the relationships between these care activities and psychological well-being. Respondents answered a survey detailing their caring activities, the amount of time that they spent on those activities and how comfortable they felt engaging in them. Psychological well-being was assessed by the Depression Anxiety Stress Scales-21. A total of 197 carers took part in the study. The majority (76%) were women, mean age 57.4. Mean time since diagnosis was 6.2 years. In the past month, 45% of carers did not spend any extra time per week helping their relative/friend with general caring activities such as cleaning the house; 31% spent 1-19 hr/week and 23% spent 20 or more hours/week doing so. Most carers were comfortable assisting their relative/friend, though more carers felt uncomfortable assisting with HNC-specific support tasks (31% uncomfortable helping with medication) compared with general support tasks (7% uncomfortable helping with appointments). Feeling uncomfortable with head and neck-specific care tasks was a significant predictor of experiencing depression and anxiety.


Assuntos
Cuidadores/psicologia , Neoplasias de Cabeça e Pescoço/enfermagem , Adulto , Idoso , Ansiedade/etiologia , Transtorno Depressivo/etiologia , Feminino , Neoplasias de Cabeça e Pescoço/psicologia , Humanos , Modelos Logísticos , Masculino , Pessoa de Meia-Idade , Fatores de Risco , Autoeficácia , Apoio Social , Estresse Psicológico/etiologia
16.
Am J Transplant ; 17(8): 2207-2211, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28199784

RESUMO

It is recognized that patients may become sensitized to donor-specific HLA antigens as a result of previous antigenic exposures, classically through previous transplantation, pregnancy, or blood transfusion. We present an unusual case of a patient who unexpectedly developed a range of anti-HLA antibodies following orthopedic surgery where a bone graft was deployed intraoperatively. We describe the case of a 52-year-old man awaiting a renal transplantation, undergoing elective orthopedic surgery requiring a small-volume bone graft. His postoperative antibody profile was found to be substantially changed compared to his previous negative samples, with the presence of HLA-DR, DQ, and DP specificities, at levels that would be likely to give a positive flow cytometry crossmatch and therefore according to local procedures required listing as unacceptable antigens for organ allocation. We perform a literature review of all previous cases of allosensitization following bone graft. This case is the first to demonstrate allosensitization following minor surgery with ;low-volume bone graft. Previous evidence is very limited and pertains only to massive osteochondral surgery for trauma or malignancy, and is confounded by potential concomitant blood transfusion. Clinicians should be aware of the risk of allosensitization where bone grafts are used.


Assuntos
Transplante Ósseo , Antígenos HLA/imunologia , Histocompatibilidade/imunologia , Hipersensibilidade/imunologia , Isoanticorpos/sangue , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico
17.
Anaesthesia ; 77(8): 945, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35466400
19.
Anaesthesia ; 72(6): 686-693, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28439886

RESUMO

Pulse oximetry is an essential monitor for safe anaesthesia but is often not available in low-income countries. The aim of this study was to determine whether the introduction of pulse oximetry with training was feasible and could reduce the incidence of oxygen desaturation during anaesthesia in a low-income country. Pulse oximeters were donated, with training, to 83 non-physician anaesthetists in Malawi. Knowledge was tested immediately before and after training and at follow-up. Providers were asked to record the lowest peripheral oxygen saturation (SpO2 ) for the first 100 cases anaesthetised after training. The primary clinical outcome was the proportion of cases with an oxygen desaturation event (SpO2 < 90%). Seventy-seven of 83 (93%) participants completed all pre- and post-training tests. Pulse oximetry knowledge improved after training from a median (IQR [range]) score of 39 (37-42 [28-48]) to 44 (42-46 [35-50]) and this knowledge was maintained for 8 months (p < 0.001). Oxygen saturation data and provider responses were recorded for 4772 cases. The proportion of oxygen desaturation episodes decreased from 17.2% to 6.5%, representing a 36% reduction in the odds of an oxygen desaturation event in the second 50 cases compared with the first 50 (OR 0.64, 95%CI 0.50-0.82, p < 0.001). We conclude that donation of pulse oximeters, with training, in Malawi was feasible, improved knowledge and reduced the incidence of oxygen desaturation events.


Assuntos
Anestesia , Anestesiologia/educação , Hipóxia/diagnóstico , Complicações Intraoperatórias/diagnóstico , Oximetria , Adulto , Idoso , Países em Desenvolvimento , Feminino , Humanos , Hipóxia/epidemiologia , Hipóxia/terapia , Complicações Intraoperatórias/epidemiologia , Malaui/epidemiologia , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica , Oxigênio/sangue , Inquéritos e Questionários , Resultado do Tratamento , Adulto Jovem
20.
J Quant Spectrosc Radiat Transf ; 186: 17-39, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-32817995

RESUMO

TEMPO was selected in 2012 by NASA as the first Earth Venture Instrument, for launch between 2018 and 2021. It will measure atmospheric pollution for greater North America from space using ultraviolet and visible spectroscopy. TEMPO observes from Mexico City, Cuba, and the Bahamas to the Canadian oil sands, and from the Atlantic to the Pacific, hourly and at high spatial resolution (~2.1 km N/S×4.4 km E/W at 36.5°N, 100°W). TEMPO provides a tropospheric measurement suite that includes the key elements of tropospheric air pollution chemistry, as well as contributing to carbon cycle knowledge. Measurements are made hourly from geostationary (GEO) orbit, to capture the high variability present in the diurnal cycle of emissions and chemistry that are unobservable from current low-Earth orbit (LEO) satellites that measure once per day. The small product spatial footprint resolves pollution sources at sub-urban scale. Together, this temporal and spatial resolution improves emission inventories, monitors population exposure, and enables effective emission-control strategies. TEMPO takes advantage of a commercial GEO host spacecraft to provide a modest cost mission that measures the spectra required to retrieve ozone (O3), nitrogen dioxide (NO2), sulfur dioxide (SO2), formaldehyde (H2CO), glyoxal (C2H2O2), bromine monoxide (BrO), IO (iodine monoxide),water vapor, aerosols, cloud parameters, ultraviolet radiation, and foliage properties. TEMPO thus measures the major elements, directly or by proxy, in the tropospheric O3 chemistry cycle. Multi-spectral observations provide sensitivity to O3 in the lowermost troposphere, substantially reducing uncertainty in air quality predictions. TEMPO quantifies and tracks the evolution of aerosol loading. It provides these near-real-time air quality products that will be made publicly available. TEMPO will launch at a prime time to be the North American component of the global geostationary constellation of pollution monitoring together with the European Sentinel-4 (S4) and Korean Geostationary Environment Monitoring Spectrometer (GEMS) instruments.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA