RESUMO
PURPOSE: To investigate the feasibility of the avatera system for performing robot-assisted radical cystectomy (RARC) followed by intracorporeal reconstruction of ileal neobladder. METHODS: Six anesthetized female pigs were used to perform RARC and formation of the intracorporeal orthotopic ileal neobladder. Three surgeons with different level of expertise in the use of robotic systems performed RARC after a short instructional lecture and a 2-h hands-on training. The urinary diversion phase was performed only by the experienced surgeon. The successful completion of the procedure, operative time for demolitive and reconstructive phases, intraoperative blood loss and malfunction of the robotic system were evaluated. RESULTS: An improvement of the operative time was observed for each surgeon. The experienced surgeon, the fellow and the resident improved their time by 11, 15, and 22 min, respectively, between the first and the second RARC performed. The most significant time difference was demonstrated by the resident, who had no previous experience in using robotic systems. The time difference between the first and the last orthotopic ileal neobladder creation for the experienced surgeon was 51 min. CONCLUSION: The feasibility of avatera system for performing complex surgical procedure such as RARC with intracorporeal neobladder formation was demonstrated by this experimental study. No major bleeding or severe malfunctions were observed during the procedures. Significant improvement in operative time was demonstrated with the increasing experience from 1st to 6th case.
Assuntos
Procedimentos Cirúrgicos Robóticos , Robótica , Neoplasias da Bexiga Urinária , Derivação Urinária , Feminino , Animais , Suínos , Cistectomia/métodos , Neoplasias da Bexiga Urinária/cirurgia , Estudos de Viabilidade , Resultado do Tratamento , Derivação Urinária/métodos , Procedimentos Cirúrgicos Robóticos/métodosRESUMO
INTRODUCTION AND OBJECTIVES: Virtual BasketTM , Bubble BlastTM , and Vapor TunnelTM are three laser pulse modulation technologies that modify the holmium: yttrium-aluminum-garnet (Ho:YAG) laser pulse transmission through the creation of bubbles emerging from the fiber tip with different effects on the target stone. The primary outcome of the current study was to test the stone ablation rates for the different pulse modulation modes, Virtual Basket, Bubble Blast, and Vapor Tunnel, using different power, energy, and frequency settings. MATERIALS AND METHODS: Quanta Cyber: Ho 150 WTM , a 365 µm PrecisionTM fiber, and hard and soft phantom BegoStonesTM were used in an in vitro experimental configuration in a saline bath. In the Virtual Basket mode, the combinations of power, energy and frequency were tested; 10 W = 0.5 J × 20 Hz, 10 W = 0.5 J × 20 Hz, 60 W = 1 J × 60 Hz and 60 W = 2 J × 30 Hz. In the Bubble Blast mode, the combinations, 12 W = 1.2J × 10 Hz, 60 W = 1.2J × 50 Hz and 60 W = 2 J × 30 Hz, were tested. Similarly, the combination of 10 W = 0.5 J × 20 Hz was tested with Vapor Tunnel mode. High-speed camera captures of the bubble formation and regular photographs of the fragmentation pattern were also taken for each mode. RESULTS: High power lithotripsy was faster and related to higher ablation rates. The Virtual Basket, Bubble Blast, and Vapor Tunnel modalities showed different ablation rates for the same energy and frequency settings. For hard stones, there was an improvement in the ablation rate using 60 W = 2 J × 30 Hz compared with 60 W = 1 J × 60 Hz and 60 W = 1.2 J × 50 Hz. The highest ablation rates were recorded using the Virtual Basket mode with the high-power settings of 2 J of energy and 30 Hz of frequency. CONCLUSIONS: The Virtual BasketTM pulse-modulation technology was related to the highest ablation rates for both hard and soft stones, compared to the Bubble BlastTM and the Vapor TunnelTM technologies in high-power and low-power lithotripsy respectively. For the same high power settings, higher energy seems to provide higher ablation rates.
Assuntos
Lasers de Estado Sólido , Litotripsia a Laser , Hólmio , Lasers de Estado Sólido/uso terapêutico , Imagens de FantasmasRESUMO
(1) Background: This study aims to evaluate how different irrigation settings and the use of ureteral access sheaths (UASs) of varying sizes impact intrarenal pressure (IRP) during flexible ureteroscopy (fURS) procedures in pigs. (2) Methods: This study utilized three anesthetized female pigs. A novel flexible ureteroscope with the ability to continuously record live intrarenal pressure was used to perform ureteroscopy in different settings. Ureteroscopy was performed without UAS and with the use of 11/13 and 12/14 UAS at the ureteropelvic junction. Two different irrigation methods were employed for each parameter: one using gravity flow and the other using manual pumping with a commercial pump. IRP was also recorded with the presence of a laser fiber or lithotripsy basket. (3) Results: The recorded mean IRP during flexible URS without UAS was 28.25 (±11.2) under gravity irrigation; 35.46 (±10.08) under manual pumping; 22.5 (±3.05) and 30.75 (±5.79) with a laser fiber under gravity irrigation and manual pumping, respectively; and 16.45 (±1.27) and 17.27 (±3.69) with a lithotripsy basket under gravity irrigation and manual pumping, respectively. With an 11/13 UAS, the mean IRP was 15.41 (±8.57) and 19.33 (±4.26) under gravity and manual pumping irrigation, respectively; 14.56 (±2.50) and 18.64 (±5.13) with a laser in each irrigation setting, respectively; and 13.10 (±3.39) and 13.86 (±4.63) with a lithotripsy basket, respectively. With a 12/14 UAS, the mean IRP was 7.64 (±3.08) and 9.25 (±1.42) under gravity and manual pumping irrigation, respectively; 9.50 (±6.04) and 10.28 (3.46), respectively, in each setting when the laser fiber was used; and 5.32 (±1.57) and 6.26 (±1.79), respectively, when the lithotripsy basket was inserted. (4) Conclusion: Novel flexible ureteroscopes with integrated pressure sensors are both a feasible and reliable tool during fURS, giving the surgeon the ability to live-track the IRP. The results of the IRP measurements with and without UAS are in accordance with the current literature and exhibit a consistent pattern with previous studies.
RESUMO
Inflatable penile prosthesis (IPP) surgery is an effective treatment for erectile dysfunction (ED), but infections pose a significant threat to its success. Current guidelines lack antifungal recommendations, despite rising fungal infection rates post-IPP surgery. This review examines epidemiology, risk factors (including diabetes mellitus, immunosuppression, and obesity), and pathogenesis, highlighting the role of biofilm formation in device contamination. Clinical manifestations vary from acute to delayed, with fungal biofilms presenting challenges in diagnosis. Prophylactic strategies, including broad-spectrum antibiotics and antifungals, are crucial, with evidence suggesting a 92% reduction in infections. With fungal infections showing lower salvage rates, management involves culture-guided treatment, irrigation, and oral antibiotics. Future research aims to understand biofilm mechanisms and develop biomaterials to reduce infection rates. Implementing antifungal therapy, along with standard practices like the no-touch technique and antibiotic dips, is crucial in preventing IPP infections.
RESUMO
PURPOSE: The aim of this study is the evaluation of the distribution of paclitaxel (PTX) released by a coated balloon in the layers of rabbit's urethra. METHODS: 18 rabbits were included. A laser device was used for the stricture formation. After two weeks, dilation of the strictured urethra was performed by using Advance 35LP PTA balloons and Advance 18 PTX PTA balloons. The experimental models were divided into 3 groups. The group Α included two rabbits without any intervention except for the stenosis procedure. Group B compromised six rabbits that underwent dilation with Advance 35LP PTA balloons. Group C consisted of 10 rabbits to which dilation with both Advance 35LP PTA balloons and Advance 18 PTX PTA balloons was applied. Histological evaluation and Immunohistochemistry were performed on all specimens. RESULTS: Inflammation, fibrosis and ruptures were detected in the specimens of the study. In specimens of Group C the decrease of inflammation and fibrosis rate was greater. Anti-PTX antibody was detected in the epithelium, lamina propria and smooth muscle layer of all specimens of urethras that have been harvested immediately and 1 day after the dilation with Advance 18 PTX PTA balloon and it was not observed in any layer of the urethral wall of the rest of the examined specimens of Group C. CONCLUSIONS: PTX's enrichment was detected in the smooth muscle layer of all specimens that have been harvested immediately and 24h after the dilation with Advance 18 PTX PTA balloons. PTX may play an inhibitive role in the recurrence of the stenosis.
Assuntos
Estreitamento Uretral , Animais , Coelhos , Estreitamento Uretral/terapia , Paclitaxel , Uretra , Constrição Patológica , Fibrose , InflamaçãoRESUMO
OBJECTIVE: To evaluate retrospectively the feasibility of Florence robotic intracorporeal neobladder technique in laparoscopic radical cystectomy. METHODS: Fourteen patients with muscle-invasive bladder cancer underwent laparoscopic radical cystectomy and Florence robotic intracorporeal neobladder between September 2021 and February 2023. Patients' characteristics, pathology data, perioperative outcomes, postoperative complications, and follow-up data were collected. RESULTS: All operations were successfully completed laparoscopically. The median total operative time was 343 minutes, and the median estimated blood loss was 169.5 mL. No intraoperative complications were observed. The median hospitalization time was 7days, while the median time to regular diet was 3days. Clavien Dindo Grade < III complications appeared in five patients within 30days postoperation. No other complications were noted over the 90days follow-up. Organ-confined disease was confirmed in 11 patients and locally advanced disease in three patients. At 3months follow-up, eight and four patients were daytime and night-time continent, respectively. CONCLUSION: Replicating Florence robotic intracorporeal neobladder in laparoscopic radical cystectomy is safe, feasible, and repeatable, based on the encouraging perioperative, oncological, and functional outcomes of our study. However, further prospective studies on a larger scale are required to prove its long-term results.
Assuntos
Laparoscopia , Procedimentos Cirúrgicos Robóticos , Neoplasias da Bexiga Urinária , Derivação Urinária , Humanos , Cistectomia/métodos , Estudos Retrospectivos , Estudos Prospectivos , Resultado do Tratamento , Neoplasias da Bexiga Urinária/patologia , Laparoscopia/métodos , Derivação Urinária/métodos , Procedimentos Cirúrgicos Robóticos/métodosRESUMO
Objective: To evaluate the efficacy and safety of Holmium: Yttrium-Aluminum-Garnet (Ho:YAG) laser in bladder lithotripsy using high-power settings > 100 W. Materials and Methods: A combined experimental and clinical study was conducted. The Quanta Cyber: Ho 150 with a 550 µm Quanta optical fiber was utilized in all set-ups. Ablation rates for soft and hard artificial stones were tested in vitro using 100 W and 20 W power settings. In the experiment, a porcine bladder was used. The optical fiber was inserted through a rigid cystoscope, whilst a K-type thermocouple was inserted in the bladder dome. The tested high-power settings were 152 W, 120 W and 105 W. In every trial, the lasing time was over 60 s. In the clinical study, 35 patients underwent transurethral high-power bladder lithotripsy. Laser settings were set between 100 W and 150 W. Results: Stone mass (stone weight) was significantly lower after stone ablation independently of the stone type or the laser settings. Significantly higher mass decrease and ablation rate were detected in high-power compared to low-power settings. In the experiment, the highest temperature recorded was 32°C at 152 W. At 120 W and 105 W, the peak temperatures didn't reach 30°C. In the clinical study, a stone-free rate of 100% and a mean operative time of 43 ± 18 min were reported. All patients stayed in the hospital for one day except for one who presented minor hematuria. Additional complications did not occur. Conclusion: Ho:YAG laser lithotripsy > 100 W is an effective, fast and safe modality for the treatment of bladder calculi.
RESUMO
PURPOSE: To investigate the learning curve in four basic surgical skills in laparoscopic and robotic surgeries, and evaluate the approximate time needed to reach sufficient expertise in performing these tasks with the avatera® system. METHODS: Twenty urology residents with no previous experience in dry-lab and robotic surgery were asked to complete four basic laparoscopic tasks (peg transfer, circle cutting, needle guidance, and suturing) laparoscopically and robotically. All participants were asked to complete the tasks first after watching the Uroweb educational material and, second, after undertaking a 2-hour training in robotic and laparoscopic dry-lab. Thereafter, all trainees continued to undertake 2-hour training programs until being able to complete the tasks with the avatera® robot at the desired time. Paired t test and one-way ANOVA test were used to analyze time differences between the groups. RESULTS: Time needed to complete all tasks either robotically or laparoscopically was significantly less in the second compared to the first attempt for all Groups in each Task. In the robotic dry-lab, time needed to complete the tasks was significantly less than in the laparoscopic dry-lab. A significant effect of previous laparoscopic experience of the participants on the training time needed to achieve most of the goal times was detected. CONCLUSION: The results of the study highlight the role of previous laparoscopic experience in the training time needed to achieve the performance time goals and demonstrate that the learning curve of basic surgical skills using the avatera® system is steeper than the laparoscopic one.
Assuntos
Laparoscopia , Procedimentos Cirúrgicos Robóticos , Robótica , Humanos , Procedimentos Cirúrgicos Robóticos/métodos , Competência Clínica , Robótica/educação , Laparoscopia/métodos , Curva de AprendizadoRESUMO
Introduction: The aim of this study was to evaluate outflow variation in different locations of the pyelocaliceal system with the use of different ureteral access sheath (UAS) sizes and different UAS positioning. Material and methods: The experimental setup included an anaesthetised porcine model, a 7.5-Fr ureteroscope with a 200-µm laser fibre inserted in the working channel, a hand-held pumping irrigating system, and UAS of different sizes, namely: 9.5/11.5 Fr, 12/14 Fr, and 14/16 Fr. Each UAS was placed just below the ureteropelvic junction (UPJ) or in the mid-ureter. The ureteroscope was placed in the renal pelvis, upper and lower calyces, and outflow measurements were obtained with 3-second interval pumping for one minute in every experimental setup. Results: The UAS positioning in the mid-ureter was associated with significantly higher outflow rates in the lower calyx (p = 0.041). While the UAS was below the UPJ, we observed a trend of lower outflow rate in the lower calyx, which was completely inverted when the UAS was in the mid-ureter. Increasing the UAS size from 9.5/11.5 Fr to 12/14 Fr led to a significant increase in outflow in the renal pelvis and upper calyx (p = 0.007), but not in the lower calyx. A further increase to 14/16 Fr did not produce increased flow. Conclusions: Different locations of the pyelocaliceal system have different fluid mechanics during fURS. In the renal pelvis and upper calyx increasing the diameter of the UAS improved the outflow, whereas in the lower calyx the position of the UAS seems to be the most relevant factor. These variables should be considered when performing fURS, especially with high-power laser lithotripsy.
RESUMO
OBJECTIVE: To evaluate the tissue injury caused by the force applied by the roboticassisted graspers of avatera robotic surgical system on bowel tissue. METHODS: An experimental in vivo porcine model with 1 pig was conducted. After a standard transperitoneal setup of the avatera robotic surgical system, different laparoscopic and robotic graspers were used on the bowel with maximum force applied each time. Robotic atraumatic grasper, laparoscopic right angle grasper, laparoscopic curved grasper, and laparoscopic atraumatic grasper were used. After using all graspers, the pig was sacrificed. The bowel segments were resected and sent for histological analysis. RESULTS: The pathologist reported that all the graspers caused signs of acute inflammation without any irreversible damage or signs compatible with ischemia of the tissue. No significant difference in histology was observed between the graspers. CONCLUSION: No permanent damage was caused by graspers, except for acute, reversible inflammation. Concluding, the avatera grasper could be safe to use on bowel segments, independent of the applied pressure.
RESUMO
Incorporating pigments into polymers can be done for various purposes, including the introduction of color, interfacial effects, or aesthetics. If these pigments are to disperse properly, then the process of extrusion must be optimized. During polymer compounding extrusion, three effective processing factors were investigated: feed rate (FR), speed (Sp.) and temperature (temp.) for a colored compounded polycarbonate (PC) grade (30/70%). The processing design techniques were obtained by applying design experiments in a response surface methodology (RSM) to blend two polycarbonates with pigments and optimize the processing temperatures at center points. The first study decided to utilize the response surface approach of Box-Behnken design (BBD) to design an experiment to optimize the process parameters. Statistical significance was demonstrated by the model passing all diagnostic tests. Furthermore, the three processing factors strongly impacted the characteristics of the tri-stimulus color, according to the results from a variance analysis. The second study identified process variables for the same PC grade at the center level, 25 kg/h FR, 750 rpm speed, and (255 °C) temp. The characterization and scanning morphology were examined using MicroCtscanner image analysis, SEM, DOM, rheology, FT-IR, and color-pigmented values were measured using a color spectrometer. The output response was significantly impacted when excellent color dispersion was observed with few agglomerates and less differences in colors at the center point. By characterizing these results and having good insight into color difference output and processing condition relationships, which have an adverse effect on color variation characteristics and minimize recycling compounds of different grades, results in cleaner environments benefits.