Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 2 de 2
Filtrar
Mais filtros

Base de dados
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Breast Cancer Res ; 25(1): 116, 2023 10 04.
Artigo em Inglês | MEDLINE | ID: mdl-37794480

RESUMO

BACKGROUND: The diagnostic accuracy of digital breast tomosynthesis (DBT) and digital mammography (DM) in breast cancer screening may vary per breast density subgroup. The purpose of this study was to evaluate which women, based on automatically assessed breast density subgroups, have the greatest benefit of DBT compared with DM in the prospective Malmö Breast Tomosynthesis Screening Trial. MATERIALS AND METHODS: The prospective European, Malmö Breast Tomosynthesis Screening Trial (n = 14,848, Jan. 27, 2010-Feb. 13, 2015) compared one-view DBT and two-view DM, with consensus meeting before recall. Breast density was assessed in this secondary analysis with the automatic software Laboratory for Individualized Breast Radiodensity Assessment. DBT and DM's diagnostic accuracies were compared by breast density quintiles of breast percent density (PD) and absolute dense area (DA) with confidence intervals (CI) and McNemar's test. The association between breast density and cancer detection was analyzed with logistic regression, adjusted for ages < 55 and ≥ 55 years and previous screening participation. RESULTS: In total, 14,730 women (median age: 58 years; inter-quartile range = 16) were included in the analysis. Sensitivity was higher and specificity lower for DBT compared with DM for all density subgroups. The highest breast PD quintile showed the largest difference in sensitivity and specificity at 81.1% (95% CI 65.8-90.5) versus 43.2% (95% CI 28.7-59.1), p < .001 and 95.5% (95% CI 94.7-96.2) versus 97.2% (95% CI 96.6-97.8), p < 0.001, respectively. Breast PD quintile was also positively associated with cancer detected via DBT at odds ratio 1.24 (95% CI 1.09-1.42, p = 0.001). CONCLUSION: Women with the highest breast density had the greatest benefit from digital breast tomosynthesis compared with digital mammography with increased sensitivity at the cost of slightly lower specificity. These results may influence digital breast tomosynthesis's use in an individualized screening program stratified by, for instance, breast density. TRIAL REGISTRATION: Trial registration at https://www. CLINICALTRIALS: gov : NCT01091545, registered March 24, 2010.


Assuntos
Densidade da Mama , Neoplasias da Mama , Feminino , Humanos , Pessoa de Meia-Idade , Neoplasias da Mama/diagnóstico por imagem , Estudos Prospectivos , Mamografia/métodos , Mama/diagnóstico por imagem , Detecção Precoce de Câncer/métodos , Programas de Rastreamento/métodos
2.
Eur Radiol ; 33(11): 8089-8099, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37145147

RESUMO

OBJECTIVES: To evaluate the total number of false-positive recalls, including radiographic appearances and false-positive biopsies, in the Malmö Breast Tomosynthesis Screening Trial (MBTST). METHODS: The prospective, population-based MBTST, with 14,848 participating women, was designed to compare one-view digital breast tomosynthesis (DBT) to two-view digital mammography (DM) in breast cancer screening. False-positive recall rates, radiographic appearances, and biopsy rates were analyzed. Comparisons were made between DBT, DM, and DBT + DM, both in total and in trial year 1 compared to trial years 2 to 5, with numbers, percentages, and 95% confidence intervals (CI). RESULTS: The false-positive recall rate was higher with DBT, 1.6% (95% CI 1.4; 1.8), compared to screening with DM, 0.8% (95% CI 0.7; 1.0). The proportion of the radiographic appearance of stellate distortion was 37.3% (91/244) with DBT, compared to 24.0% (29/121) with DM. The false-positive recall rate with DBT during trial year 1 was 2.6% (95% CI 1.8; 3.5), then stabilized at 1.5% (95% CI 1.3; 1.8) during trial years 2 to 5. The percentage of stellate distortion with DBT was 50% (19/38) trial year 1 compared to 35.0% (72/206) trial years 2 to 5. CONCLUSIONS: The higher false-positive recall rate with DBT compared to DM was mainly due to an increased detection of stellate findings. The proportion of these findings, as well as the DBT false-positive recall rate, was reduced after the first trial year. CLINICAL RELEVANCE STATEMENT: Assessment of false-positive recalls gives information on potential benefits and side effects in DBT screening. KEY POINTS: • The false-positive recall rate in a prospective digital breast tomosynthesis screening trial was higher compared to digital mammography, but still low compared to other trials. • The higher false-positive recall rate with digital breast tomosynthesis was mainly due to an increased detection of stellate findings; the proportion of these findings was reduced after the first trial year.


Assuntos
Neoplasias da Mama , Mama , Feminino , Humanos , Estudos Prospectivos , Mama/diagnóstico por imagem , Mama/patologia , Mamografia , Neoplasias da Mama/patologia , Densidade da Mama , Detecção Precoce de Câncer , Programas de Rastreamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA