Scand J Clin Lab Invest ; 84(1): 76-78, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38376201

RESUMO

Analysis of cerebrospinal fluid (CSF), including lactate, is key for diagnosis of acute meningitis. Since blood gas analyzers (BGA) enable rapid and safe blood-lactate measurements, we evaluated the reliability of RAPIDPoint 500 BGA to provide a fast and accurate measure of CSF lactate. In this study, CSF lactate levels were measured by a reference assay and on RAPIDPoint 500 BGA. Comparability was evaluated through difference analysis, using Bland Altman test, and linear regression analysis, using the Passing Bablok test. Agreement rate according to CSF lactate (≥3.5 and <3.5 mmol/L) was calculated using kappa (κ) statistic. Population study included 98 CSF samples. Concerning difference analysis, according to Bland-Altman test, bias was 0.13 mmol/L (CI 95%: -0.26 to 0.52 mmol/L. In regression analysis, according to Passing-Bablok equation a systematic difference between both assays was found. In concordance analysis, the interrate realibility was very high (κ: 0.964). According to our resuls, although a systematic difference was detected when lactate levels were measured on RAPIDPoint 500 BGA, the results from Bland-Altman test and the high agreement rate support that this POCT analyzer could be useful for a early and safe detection of patients with high probability of increased CSF lactate level.


Assuntos
Ácido Láctico , Testes Imediatos , Humanos , Reprodutibilidade dos Testes , Gasometria , Viés
3.
Cir Esp (Engl Ed) ; 102(6): 300-306, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38342139

RESUMO

AIM: Accurate diagnosis of complicated appendicitis is of importance to ensure that patients receive early and effective treatment, minimizing the risk of postoperative complications to promote successful recovery. Biochemical markers are a promising tool to identify complicated appendicitis. We aimed to evaluate the potential role of novel parameters related with neutrophil activation, known as "Extended Inflammation Parameters" (EIP), included in blood cell count reported by Sysmex XN-Series analyzers, compared to other canonical biomarkers in identifying complicated appendicitis. METHOD: Prospective observational study including patients with confirmed diagnosis of acute appendicitis. C-reactive protein (CRP), procalcitonin, cell blood count, including white blood cell (WBC), absolute neutrophil (ANC) and immature granulocyte (IG) count and EIP (neutrophil reactivity [NEUT-RI] and granularity intensity [NEUT-GI]) were analyzed before surgery. Their accuracy to diagnose complicated appendicitis was tested in an ROC curve analysis. RESULTS: Our population study included 119 patients, and appendicitis was complicated in 58 (48.7%). NLR, CRP and procalcitonin levels, ANC and IG count and NEUT-RI and NEUT-GI were higher in patients with complicated appendicitis. Regarding accuracy for complicated appendicitis, CRP was the biomarker with the highest performance (ROC AUC: 0.829), with an optimal cutoff of 73.1 mg/L (sensitivity: 63.8%, specificity: 88.5%). NEUT-RI and NEUT-GI achieved both significant but poor accuracy, with ROC AUC of 0.606 and 0.637, respectively. CONCLUSIONS: Novel laboratory tests reported by Sysmex XN-Series analyzers have poor accuracy for identifying complicated appendicitis. In this study, CRP was the biomarker with the highest performance and may be useful as predictor of the severity of acute appendicitis.


Assuntos
Apendicite , Biomarcadores , Proteína C-Reativa , Ativação de Neutrófilo , Pró-Calcitonina , Apendicite/sangue , Apendicite/diagnóstico , Apendicite/cirurgia , Humanos , Estudos Prospectivos , Feminino , Masculino , Adulto , Proteína C-Reativa/análise , Pessoa de Meia-Idade , Biomarcadores/sangue , Pró-Calcitonina/sangue , Doença Aguda , Contagem de Leucócitos/métodos , Contagem de Leucócitos/instrumentação , Testes Hematológicos/métodos , Testes Hematológicos/instrumentação , Curva ROC , Idoso , Neutrófilos , Inflamação/sangue