Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 105
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Cardiovasc Diabetol ; 21(1): 246, 2022 11 16.
Artigo em Inglês | MEDLINE | ID: mdl-36384656

RESUMO

BACKGROUND: Diabetes Mellitus (DM) affects a third of patients with symptomatic severe aortic valve stenosis undergoing transcatheter aortic valve implantation (TAVI). DM is a well-known risk factor for cardiac surgery, but its prognostic impact in TAVI patients remains controversial. This study aimed to evaluate outcomes in diabetic patients undergoing TAVI. METHODS: This multicentre registry includes data of > 12,000 patients undergoing transfemoral TAVI. We assessed baseline patient characteristics and clinical outcomes in patients with DM and without DM. Clinical outcomes were defined by the second valve academic research consortium. Propensity score matching was applied to minimize potential confounding. RESULTS: Of the 11,440 patients included, 31% (n = 3550) had DM and 69% (n = 7890) did not have DM. Diabetic patients were younger but had an overall worse cardiovascular risk profile than non-diabetic patients. All-cause mortality rates were comparable at 30 days (4.5% vs. 4.9%, RR 0.9, 95%CI 0.8-1.1, p = 0.43) and at one year (17.5% vs. 17.4%, RR 1.0, 95%CI 0.9-1.1, p = 0.86) in the unmatched population. Propensity score matching obtained 3281 patient-pairs. Also in the matched population, mortality rates were comparable at 30 days (4.7% vs. 4.3%, RR 1.1, 95%CI 0.9-1.4, p = 0.38) and one year (17.3% vs. 16.2%, RR 1.1, 95%CI 0.9-1.2, p = 0.37). Other clinical outcomes including stroke, major bleeding, myocardial infarction and permanent pacemaker implantation, were comparable between patients with DM and without DM. Insulin treated diabetics (n = 314) showed a trend to higher mortality compared with non-insulin treated diabetics (n = 701, Hazard Ratio 1.5, 95%CI 0.9-2.3, p = 0.08). EuroSCORE II was the most accurate risk score and underestimated 30-day mortality with an observed-expected ratio of 1.15 in DM patients, STS-PROM overestimated actual mortality with a ratio of 0.77 and Logistic EuroSCORE with 0.35. CONCLUSION: DM was not associated with mortality during the first year after TAVI. DM patients undergoing TAVI had low rates of mortality and other adverse clinical outcomes, comparable to non-DM TAVI patients. Our results underscore the safety of TAVI treatment in DM patients. TRIAL REGISTRATION: The study is registered at clinicaltrials.gov (NCT03588247).


Assuntos
Estenose da Valva Aórtica , Diabetes Mellitus , Substituição da Valva Aórtica Transcateter , Humanos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/epidemiologia , Diabetes Mellitus/etiologia , Pontuação de Propensão , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Estudos Multicêntricos como Assunto , Sistema de Registros
2.
Catheter Cardiovasc Interv ; 100(5): 832-838, 2022 11.
Artigo em Inglês | MEDLINE | ID: mdl-36116033

RESUMO

OBJECTIVE: Patients with rapidly deteriorating clinical status due to severe aortic stenosis are often referred for expedited transcatheter aortic valve replacement (TAVR). Data regarding the outcome of such interventions is limited. We aimed to evaluate the outcome of patients undergoing expedited TAVR. DESIGN AND SETTING: Data were derived from the Israeli Multicenter Registry. SUBJECTS: Subjects were divided into two groups based on procedure urgency: patients who were electively hospitalized for the procedure (N = 3140) and those who had an expedited TAVR (N = 142). Procedural and periprocedural complication rates were significantly higher among patients with an expedited indication for TAVR compared to those having an elective procedure: valve malposition 4.6% versus 0.6% (p < 0.001), procedural cardiopulmonary resuscitation 4.3% versus 1.0% (p = 0.007), postprocedure myocardial infarction 2.0% versus 0.4% (p = 0.002), and stage 3 acute kidney injury 3.0% versus 1.1%, (p < 0.001). Patients with expedited indication for TAVR had significantly higher in hospital mortality (5.6% vs. 1.4%, p = 0.003). Kaplan-Meier's survival analysis showed that patients undergoing expedited TAVR had higher 3-year mortality rates compared to patients undergoing an elective TAVR procedure (p < 0.001). Multivariate analysis found that patients with expedited indication had fourfolds increased risk of in-hospital mortality (odds ratio: 4.07, p = 0.001), and nearly twofolds increased risk of mortality at 3-year (hazard ratio: 1.69, p = 0.001) compared to those having an elective procedure. CONCLUSION: Patients with expedited indications for TAVR suffer from poor short- and long-term outcomes. It is important to characterize and identify these patients before the deterioration to perform TAVR in a fast-track pathway to minimize their procedural risk.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Humanos , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/métodos , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/complicações , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Resultado do Tratamento , Índice de Gravidade de Doença , Fatores de Risco , Catéteres
3.
Infection ; 50(1): 57-64, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34089484

RESUMO

PURPOSE: To evaluate the impact of a multidisciplinary the "Endocarditis Team" (ET) on the course and outcome of infective endocarditis (IE) patients. METHODS: A retrospective before-after study, including hospitalized patients with definite IE, managed before (01.2013-12.2015) and after (01.2016-07.2019) the introduction of an ET. The primary outcomes were defined as 30-day and 1-year mortality and the secondary as conservative vs. invasive strategy, the interval from clinical suspicion of IE to the performance of echocardiography, utilization of multimodality evaluation, time to an invasive procedure, and the duration of hospitalization. RESULTS: Study population included 92 pre-ET and 128 post-ET implementation patients. Baseline characteristics were similar. During the post-ET period compared with pre-ET, we found higher rates of abscesses and extra-cardiac emboli (27.8% vs. 16.3%, p = 0.048); and a higher invasive procedures rate, including lead extraction (15.6% vs. 6.5%, p = 0.035) and noncardiac surgeries (14.8% vs. 6.5%, p = 0.05). Patients managed during the post-ET period had reduced short (8.5% vs. 17.4%, p = 0.048) and long-term mortality (Log-rank = 0.001). In multivariate analysis of risk factors for long-term mortality, period (pre- or post-ET) was not found to be significantly associated with the mortality. CONCLUSION: Establishment of an ET was associated with faster and more intensive evaluation of patients with IE. During the period of an ET activity, mortality rates were reduced compared with the previous period.


Assuntos
Endocardite Bacteriana , Endocardite , Endocardite/diagnóstico , Endocardite/epidemiologia , Endocardite/terapia , Mortalidade Hospitalar , Hospitalização , Humanos , Estudos Retrospectivos , Fatores de Risco
4.
Int J Qual Health Care ; 34(4)2022 Nov 17.
Artigo em Inglês | MEDLINE | ID: mdl-36271838

RESUMO

BACKGROUND: Since the beginning of the coronavirus disease 2019 (COVID-19) pandemic in 2019, several countries have reported a substantial drop in the number of patients admitted with non-ST-segment myocardial infarction (NSTEMI). OBJECTIVE: We aimed to evaluate the changes in admissions, in-hospital management and outcomes of patients with NSTEMI in the COVID-19 era in a nationwide survey. METHOD: A prospective, multicenter, observational, nationwide study involving 13 medical centers across Israel aimed to evaluate consecutive patients with NSTEMI admitted to intensive cardiac care units over an 8-week period during the COVID-19 outbreak and to compare them with NSTEMI patients admitted at the same period 2 years earlier (control period). RESULTS: There were 624 (43%) NSTEMI patients, of whom 349 (56%) were hospitalized during the COVID-19 era and 275 (44%) during the control period. There were no significant differences in age, gender and other baseline characteristics between the two study periods. During the COVID-19 era, more patients arrived at the hospital via an emergency medical system compared with the control period (P = 0.05). Time from symptom onset to hospital admission was longer in the COVID-19 era as compared with the control period [11.5 h (interquartile range, IQR, 2.5-46.7) vs. 2.9 h (IQR 1.7-6.8), respectively, P < 0.001]. Nevertheless, the time from hospital admission to reperfusion was similar in both groups. The rate of coronary angiography was also similar in both groups. The in-hospital mortality rate was similar in both the COVID-19 era and the control period groups (2.3% vs. 4.7%, respectively, P = 0.149) as was the 30-day mortality rate (3.7% vs. 5.1%, respectively, P = 0.238). CONCLUSION: In contrast to previous reports, admission rates of NSTEMI were similar in this nationwide survey during the COVID-19 era. With longer time from symptoms to admission, but with the same time from hospital admission to reperfusion therapy and with similar in-hospital and 30-day mortality rates. Even in times of crisis, adherence of medical systems to clinical practice guidelines ensures the preservation of good clinical outcomes.


Assuntos
COVID-19 , Infarto do Miocárdio , Infarto do Miocárdio sem Supradesnível do Segmento ST , Intervenção Coronária Percutânea , Humanos , Pandemias , COVID-19/epidemiologia , Infarto do Miocárdio sem Supradesnível do Segmento ST/epidemiologia , Infarto do Miocárdio sem Supradesnível do Segmento ST/terapia , Estudos Prospectivos , Israel/epidemiologia , Infarto do Miocárdio/epidemiologia , Infarto do Miocárdio/terapia
5.
Catheter Cardiovasc Interv ; 98(7): E990-E999, 2021 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-34347381

RESUMO

OBJECTIVES: This study aimed to compare permanent pacemaker implantation (PPMI) rates among patients undergoing Trans-catheter Aortic Valve Implantation (TAVI) with first generation (G1) versus second generation (G2) valves and the impact of PPMI on long-term mortality. BACKGROUND: PPMI is a known adverse event after TAVI. Recently, two novel iterations of valve designs of both the balloon expandable valves (BEV) and self-expanding valves (SEV) were introduced as a second generation valves. METHODS: All patients included in the Israeli multicenter TAVI registry were grouped according to valve type (BEV vs. SEV) and generation (G1 vs. G2). A comparison was made for clinical and outcome indices of patients undergoing TAVI with G1 and G2 in each of the valve systems. RESULTS: A total of 1377 patients were included. The incidence of PPMI did not differ between G1-BEV versus G2-BEV (15.3% vs. 17.4%; p = 0.598) nor between G1-SEV versus G2-SEV (23.4% vs. 20.3%; p = 0.302). Depth of implantation and complete right bundle branch block were independently associated with PPMI post-TAVI in both valve systems. PPMI was not associated with an increased risk for 2-year mortality. CONCLUSIONS: The incidence of PPMI remains a relevant adverse event post-TAVI even when the newer generation valves are used. Since the predictors for PPMI are well established, a standardized approach for the management of conduction disorders is much needed.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Marca-Passo Artificial , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
6.
Catheter Cardiovasc Interv ; 98(5): E758-E767, 2021 11 01.
Artigo em Inglês | MEDLINE | ID: mdl-33682347

RESUMO

OBJECTIVES: Right ventricular (RV) dysfunction and tricuspid regurgitation (TR) are associated with adverse outcomes in severe aortic stenosis (AS) patients. Our aim was to evaluate the association between ≥moderate TR and RV dysfunction on long-term mortality following transcatheter aortic valve replacement (TAVR). METHODS: A retrospective analysis of the Israeli multicenter TAVR registry among 4,344 consecutive patients, with all-cause mortality as the main outcome measure. RESULTS: Echocardiographic assessment of TR grade and RV dysfunction was available for 3,733 and 1,850 patients, of whom ≥moderate TR and RV dysfunction was noted for 478(13%) and 78(4%), respectively. The mean follow-up time was 2.9 ± 2.3 years. In univariate models, ≥Moderate TR and ≥moderate RV dysfunction were associated with increased long-term mortality (HR 1.45, 95% CI 1.24-1.69, p < .001 and HR 1.73, 95% CI 1.21-2.47, p = 0.003, respectively). These finding did not remained significant after adjusting to echocardiographic parameters. A subset of patients with no improvement in RV function had the highest long-term mortality risk (HR 3.3, 95% CI 1.95-5.7, p < .001). CONCLUSION: When adjusted to multiple echocardiographic characteristics baseline ≥Moderate TR and ≥moderate RV dysfunction were not associated with long-term mortality following TAVR. Persistent RV dysfunction following TAVR was associated with the highest risk for mortality.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Insuficiência da Valva Tricúspide , Disfunção Ventricular Direita , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Humanos , Prognóstico , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Disfunção Ventricular Direita/diagnóstico por imagem , Disfunção Ventricular Direita/etiologia
7.
Catheter Cardiovasc Interv ; 98(6): E862-E869, 2021 11 15.
Artigo em Inglês | MEDLINE | ID: mdl-33961729

RESUMO

OBJECTIVES: To evaluate the use and outcomes of percutaneous mechanical circulatory support (pMCS) utilized during transcatheter aortic valve implantation (TAVI) from high-volume centers. METHODS AND RESULTS: Our international multicenter registry including 13 high-volume TAVI centers with 87 patients (76.5 ± 11.8 years, 63.2% men) who underwent TAVI for severe aortic stenosis and required pMCS (75.9% VA-ECMO, 19.5% Impella CP, 4.6% TandemHeart) during the procedure (prior to TAVI 39.1%, emergent rescue 50.6%, following TAVI 10.3%). The procedures were considered high-risk, with 50.6% having severe left ventricular dysfunction, 24.1% biventricular dysfunction, and 32.2% severe pulmonary hypertension. In-hospital and 1-year mortality were 27.5% and 49.4%, respectively. Patients with prophylactic hemodynamic support had lower periprocedural mortality compared to patients with rescue insertion of pMCS (log rank = 0.013) and patients who did not undergo cardiopulmonary resuscitation during the TAVI procedure had better short and long term survival (log rank <0.001 and 0.015, respectively). CONCLUSIONS: Given the overall survival rate and low frequency of pMCS-related complications, our study results support the use of pMCS prophylactically or during the course of TAVI (bailout) in order to improve clinical outcomes in high-risk procedures or in case of acute life-threatening hemodynamic collapse.


Assuntos
Estenose da Valva Aórtica , Substituição da Valva Aórtica Transcateter , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Sistema de Registros , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
8.
Cardiology ; 146(3): 359-367, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33691314

RESUMO

OBJECTIVES: Fever following transcatheter aortic valve implantation (TAVI) is a common phenomenon, attributed mostly to inflammatory response which may impact outcome. Systemic inflammatory response may be triggered by multiple factors, most associated with the TAVI procedure itself. However, there are no data regarding the incidence of fever following TAVI in contemporary era with newer generation devices. Our primary objective was to measure temporal trends in fever incidence and features following TAVI. METHODS: We analyzed a retrospective cohort of 802 consecutive patients who underwent TAVI at our institution between November 2008 and February 2018. We identified and characterized all patients who developed fever (>38.0°C from any cause) within the first 72 h following the procedure and analyzed incidence and characteristics stratified into 3 time frames: 2008-2014, 2014-2016, and 2016-2018. RESULTS: Following TAVI, 190 (23.7%) patients developed fever (mean age 82.3 ± 5.2 years, 64.2% female). An infectious etiology was evident in only 32.1% of cases. The frequency decreased gradually and significantly across timeframes (32.8, 23.6, and 14.5%, respectively, p < 0.001). In a multivariate regression analysis, 1st generation CoreValve (HR 1.91; CI 95% 1.2-3.04, p = 0.006) was found to be associated with higher incidence of fever in addition to female gender, vascular complications, transfemoral access, and reduced GFR. CONCLUSIONS: Fever incidence post TAVI decreased significantly throughout the last decade. The higher rate of fever in the early years of TAVI was likely associated with first-generation devices, vascular complications, and reduced GFR.


Assuntos
Estenose da Valva Aórtica , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/epidemiologia , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Incidência , Masculino , Estudos Retrospectivos , Fatores de Risco , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
9.
Mediators Inflamm ; 2021: 8872686, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-33814983

RESUMO

BACKGROUND AND AIMS: Plasma levels of soluble triggering receptor expressed on myeloid cells (sTREM-1) reflect innate immune cell activation. We sought to evaluate sTREM-1 levels in patients with acute coronary syndrome (ACS) and their predictive value for disease severity and outcome. METHODS: Plasma sTREM-1 levels were prospectively measured by ELISA in 121 consecutive patients with new-onset (≤24 h) chest pain at arrival to the emergency department (ED) and 73 healthy controls. Secondary endpoints were the association of plasma levels of sTREM-1 with day 30 and month 6 major adverse cardiovascular events (MACE) defined as death, ACS, stroke, and need for coronary revascularization, as well as with CAD severity. The primary endpoint of the study was the association of plasma sTREM-1 level at the time of admission to the ED with a diagnosis of ACS at day 30. RESULTS: Fifty-nine patients (48.7%) were diagnosed with ACS and 62 (51.3%) with nonspecific chest pain (NSCP). Median plasma sTREM-1 level at admission was significantly higher in the ACS group than the NSCP group and the control group (539.4 ± 330.3 pg/ml vs. 432.5 ± 196.4 pg/ml vs. 230.1 ± 85.5 pg/ml, respectively; P < 0.001) and positively correlated with the number of stenosed/occluded coronary arteries on angiography (P < 0.001). On logistic regression analysis, higher sTREM-1 levels predicted definite ACS vs. NSCP determined on day 30 (OR 1.29, 95% CI 1.07-1.54, P = 0.01) as well as with recurrent ACS (P = 0.04) and stroke (P = 0.02) at 6 months. CONCLUSIONS: Plasma sTREM-1 levels are significantly elevated in patients with ACS and might serve as a biomarker differentiating ACS from NSCP in the ED as well as an inflammatory biomarker for coronary artery disease severity and outcome.


Assuntos
Síndrome Coronariana Aguda , Receptor Gatilho 1 Expresso em Células Mieloides/sangue , Síndrome Coronariana Aguda/metabolismo , Biomarcadores , Humanos , Células Mieloides/metabolismo , Índice de Gravidade de Doença
10.
Eur Heart J ; 41(29): 2731-2742, 2020 08 01.
Artigo em Inglês | MEDLINE | ID: mdl-32592401

RESUMO

AIMS: Due to bioprosthetic valve degeneration, aortic valve-in-valve (ViV) procedures are increasingly performed. There are no data on long-term outcomes after aortic ViV. Our aim was to perform a large-scale assessment of long-term survival and reintervention after aortic ViV. METHODS AND RESULTS: A total of 1006 aortic ViV procedures performed more than 5 years ago [mean age 77.7 ± 9.7 years; 58.8% male; median STS-PROM score 7.3% (4.2-12.0)] were included in the analysis. Patients were treated with Medtronic self-expandable valves (CoreValve/Evolut, Medtronic Inc., Minneapolis, MN, USA) (n = 523, 52.0%), Edwards balloon-expandable valves (EBEV, SAPIEN/SAPIEN XT/SAPIEN 3, Edwards Lifesciences, Irvine, CA, USA) (n = 435, 43.2%), and other devices (n = 48, 4.8%). Survival was lower at 8 years in patients with small-failed bioprostheses [internal diameter (ID) ≤ 20 mm] compared with those with large-failed bioprostheses (ID > 20 mm) (33.2% vs. 40.5%, P = 0.01). Independent correlates for mortality included smaller-failed bioprosthetic valves [hazard ratio (HR) 1.07 (95% confidence interval (CI) 1.02-1.13)], age [HR 1.21 (95% CI 1.01-1.45)], and non-transfemoral access [HR 1.43 (95% CI 1.11-1.84)]. There were 40 reinterventions after ViV. Independent correlates for all-cause reintervention included pre-existing severe prosthesis-patient mismatch [subhazard ratio (SHR) 4.34 (95% CI 1.31-14.39)], device malposition [SHR 3.75 (95% CI 1.36-10.35)], EBEV [SHR 3.34 (95% CI 1.26-8.85)], and age [SHR 0.59 (95% CI 0.44-0.78)]. CONCLUSIONS: The size of the original failed valve may influence long-term mortality, and the type of the transcatheter valve may influence the need for reintervention after aortic ViV.


Assuntos
Estenose da Valva Aórtica , Bioprótese , Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Feminino , Humanos , Masculino , Desenho de Prótese , Falha de Prótese , Resultado do Tratamento
11.
Am Heart J ; 224: 129-137, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32375104

RESUMO

BACKGROUND: Adverse cardiac remodeling is a major risk factor for the development of post myocardial infarction (MI) heart failure (HF). This study investigates the effects of the chymase inhibitor fulacimstat on adverse cardiac remodeling after acute ST-segment-elevation myocardial infarction (STEMI). METHODS: In this double-blind, randomized, placebo-controlled trial patients with first STEMI were eligible. To preferentially enrich patients at high risk of adverse remodeling, main inclusion criteria were a left-ventricular ejection fraction (LVEF) ≤45% and an infarct size >10% on day 5 to 9 post MI as measured by cardiac MRI. Patients were then randomized to 6 months treatment with either 25 mg fulacimstat (n = 54) or placebo (n = 53) twice daily on top of standard of care starting day 6 to 12 post MI. The changes in LVEF, LV end-diastolic volume index (LVEDVI), and LV end-systolic volume index (LVESVI) from baseline to 6 months were analyzed by a central blinded cardiac MRI core laboratory. RESULTS: Fulacimstat was safe and well tolerated and achieved mean total trough concentrations that were approximately tenfold higher than those predicted to be required for minimal therapeutic activity. Comparable changes in LVEF (fulacimstat: 3.5% ±â€¯5.4%, placebo: 4.0% ±â€¯5.0%, P = .69), LVEDVI (fulacimstat: 7.3 ±â€¯13.3 mL/m2, placebo: 5.1 ±â€¯18.9 mL/m2, P = .54), and LVESVI (fulacimstat: 2.3 ±â€¯11.2 mL/m2, placebo: 0.6 ±â€¯14.8 mL/m2, P = .56) were observed in both treatment arms. CONCLUSION: Fulacimstat was safe and well tolerated in patients with left-ventricular dysfunction (LVD) after first STEMI but had no effect on cardiac remodeling.


Assuntos
Quimases/antagonistas & inibidores , Insuficiência Cardíaca/tratamento farmacológico , Ventrículos do Coração/diagnóstico por imagem , Infarto do Miocárdio com Supradesnível do Segmento ST/tratamento farmacológico , Função Ventricular Esquerda/fisiologia , Remodelação Ventricular/efeitos dos fármacos , Método Duplo-Cego , Feminino , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etiologia , Ventrículos do Coração/fisiopatologia , Humanos , Imagem Cinética por Ressonância Magnética , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio com Supradesnível do Segmento ST/complicações , Infarto do Miocárdio com Supradesnível do Segmento ST/fisiopatologia , Volume Sistólico/fisiologia , Resultado do Tratamento
12.
Am Heart J ; 220: 184-191, 2020 02.
Artigo em Inglês | MEDLINE | ID: mdl-31862472

RESUMO

BACKGROUND: In contrast to surgical aortic valve replacement, left ventricle (LV) hypertrophy (LVH) had not been clearly associated with mortality following transcatheter aortic valve replacement (TAVR). METHODS: We performed a retrospective analysis of patients enrolled in the Israeli multicenter TAVR registry for whom preprocedural LV mass index (LVMI) data were available. Patients were divided into categories according to LVMI: normal LVMI and mild, moderate, and severe LVH. Mild LVH was regarded as the reference group. Additionally, LV geometry patterns were examined (concentric and eccentric LVH, and concentric remodeling). RESULTS: The cohort consisted of 1,559 patients, 46.5% male, with a mean age of 82.2 (±6.8) years and mean LVMI of 121 (±29) g/m2. Rates of normal LVMI and mild, moderate, and severe LVH were 31% (n = 485), 21% (n = 322), 18% (n = 279), and 30% (n = 475), respectively. Three-year mortality rates for normal LVMI and mild, moderate, and severe LVH were 19.8%, 18.3%, 23.7%, and 24.4%, respectively. Compared to mild LVH, moderate LVH and severe LVH were independently associated with an increased risk for all-cause mortality (hazard ratio [HR] 1.58, 95% CI 1.15-2.18, P = .005; HR 1.46, 95% CI 1.1-1.95, P = .009; respectively). Concentric LVH was independently associated with a decreased risk for mortality compared to normal LV geometry (HR 0.75, 95% CI 0.63-0.89, P = .001). Compared to concentric LVH, eccentric LVH was independently associated with a 33% increased risk for mortality (HR 1.33, 95% CI 1.11-1.60, P = .002). CONCLUSIONS: Mild concentric LVH confers a protective effect among patients with severe aortic stenosis undergoing TAVR. However, hypertrophy becomes maladaptive, and an increased baseline LVMI, eccentric pattern particularly, may be associated with all-cause mortality in this population.


Assuntos
Hipertrofia Ventricular Esquerda/mortalidade , Substituição da Valva Aórtica Transcateter/mortalidade , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/complicações , Estenose da Valva Aórtica/cirurgia , Causas de Morte , Ecocardiografia , Feminino , Humanos , Hipertrofia Ventricular Esquerda/classificação , Hipertrofia Ventricular Esquerda/etiologia , Hipertrofia Ventricular Esquerda/patologia , Israel , Masculino , Avaliação de Resultados em Cuidados de Saúde , Período Pré-Operatório , Sistema de Registros , Estudos Retrospectivos , Substituição da Valva Aórtica Transcateter/métodos
13.
Catheter Cardiovasc Interv ; 96(7): E695-E702, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-32022390

RESUMO

BACKGROUND: Transcatheter aortic valve implantation (TAVI) for aortic stenosis (AS) risk assessment is still developing and mostly concerned with mortality in the periprocedural period. We therefore sought to develop and then validate a score to predict 1-year adverse outcome. METHODS: Patients that underwent TAVI for severe AS in the Israeli registry. Patients with unsuccessful/suboptimal implantation were excluded. The cohort was split to derivation/validation cohorts by a ratio of 70:30. The outcome was defined as 1-year composite of mortality, stroke, and no improvement in NYHA class (vs. baseline). Logistic regression was used to fit the prediction model. RESULTS: Out of 2,440 patients meeting inclusion criteria, 276 were excluded, leaving 2,160 patients for both cohorts. At 1 year, 299 (14%) patients experienced the adverse ("futile") outcome. The derived prediction model included mean aortic valve (AV) gradient, previous pacemaker, previous oncological disease, need for diuretics, baseline NYHA class, hemoglobin and creatinine levels, and nonfemoral access site. The model's area under the curve (AUC) was 0.69 in the derivation and 0.70 in the validation cohort. Performance of other scores in the validation cohort were lower (0.60 for STS, 0.55 for Euroscore2, 0.56 for TVT score, and 0.53 for TAVI2-score, p = .03). Based on three risk tiers, patients had a low risk (20/306, 7% futility), a medium risk (50/304, 17%), and high risk (18/37, 49%) for futility. CONCLUSIONS: The TAVI futility risk model can be used to provide further insight regarding prediction measures and/or patients' outcomes outside of the periprocedural period (NCT02023060).


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Regras de Decisão Clínica , Futilidade Médica , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Feminino , Hemodinâmica , Humanos , Israel , Masculino , Valor Preditivo dos Testes , Sistema de Registros , Reprodutibilidade dos Testes , Medição de Risco , Fatores de Risco , Índice de Gravidade de Doença , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/mortalidade , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Substituição da Valva Aórtica Transcateter/mortalidade , Resultado do Tratamento
14.
Eur Heart J ; 40(5): 456-465, 2019 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-30590565

RESUMO

Aims: The aim of this study was to compare clinical outcomes of patients undergoing transfemoral transcatheter aortic valve implantation (TAVI) with balloon-expandable (BE) valves vs. self-expandable (SE) valves. Transcatheter aortic valve implantation is a minimally invasive and lifesaving treatment in patients with aortic valve stenosis. Even though BE-valves and SE-valves are both commonly used on a large scale, adequately sized trials comparing clinical outcomes in patients with severe aortic valve stenosis treated with BE-valves compared with SE-valves are lacking. Methods and results: In this CENTER-collaboration, data from 10 registries or clinical trials, selected through a systematic search, were pooled and analysed. Propensity score methodology was used to reduce treatment selection bias and potential confounding. The primary endpoints were mortality and stroke at 30 days follow-up in patients treated with BE-valves compared with SE-valves. Secondary endpoints included clinical outcomes, e.g. bleeding during hospital admission. All outcomes were split for early-generation BE-valves compared with early-generation SE-valves and new-generation BE-valves with new-generation SE-valves. The overall patient population (N = 12 381) included 6239 patients undergoing TAVI with BE-valves and 6142 patients with SE-valves. The propensity matched population had a mean age of 81 ± 7 years and a median STS-PROM score or 6.5% [interquartile range (IQR) 4.0-13.0%]. At 30-day follow-up, the mortality rate was not statistically different in patients undergoing TAVI with BE-valves compared with SE-valves [BE: 5.3% vs. SE: 6.2%, relative risk (RR) 0.9; 95% confidence interval (CI) 0.7-1.0, P = 0.10]. Stroke occurred less frequently in patients treated with BE-valves (BE: 1.9% vs. SE: 2.6%, RR 0.7; 95% CI 0.5-1.0, P = 0.03). Also, patients treated with BE-valves had a three-fold lower risk of requiring pacemaker implantation (BE: 7.8% vs. SE: 20.3%, RR 0.4; 95% CI 0.3-0.4, P < 0.001). In contrast, patients treated with new-generation BE-valves more frequently experienced major and life-threatening bleedings compared with new-generation SE-valves (BE: 4.8% vs. SE: 2.1%, RR 2.3; 95% CI 1.6-3.3, P < 0.001). Conclusion: In this study, which is the largest study to compare valve types in TAVI, we demonstrated that the incidence of stroke and pacemaker implantation was lower in patients undergoing transfemoral TAVI with BE-valves compared with SE-valves. In contrast, patients treated with new-generation BE-valves more often suffered from major or life-threatening bleedings than patients with new-generation SE-valves. Mortality at 30-days was not statistically different in patients treated with BE-valves compared with SE-valves. This study was a propensity-matched analysis generated from observational data, accordingly current outcomes will have to be confirmed in a large scale randomized controlled trial.


Assuntos
Estenose da Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Marca-Passo Artificial/estatística & dados numéricos , Desenho de Prótese , Acidente Vascular Cerebral/epidemiologia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/cirurgia , Conversão para Cirurgia Aberta/estatística & dados numéricos , Feminino , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Estudos Observacionais como Assunto , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/mortalidade , Pontuação de Propensão , Sistema de Registros , Acidente Vascular Cerebral/etiologia , Substituição da Valva Aórtica Transcateter/métodos , Substituição da Valva Aórtica Transcateter/mortalidade
15.
Catheter Cardiovasc Interv ; 93(7): 1361-1366, 2019 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-30489692

RESUMO

OBJECTIVE: To evaluate the efficacy and safety of periprocedural beta-blocker (BB) discontinuation among patients undergoing transcatheter aortic valve replacement (TAVR) and high degree atrioventricular block (HD-AVB) and/or atrial fibrillation (AF). METHODS: The study population comprised 743 consecutive patients who underwent TAVR between 2009 and 2017 in two high-volume tertiary centers. All patients received chronic BB therapy, and were divided into two groups: (1) BB continuation and (2) BB discontinued 24 hr prior to the procedure. The primary endpoint was the development of composite brady and tachy-arrhytmic events (including HD-AVB and/or NOAF) following the procedure. RESULTS: Among 743 study patients, 366 (49%) continued BB prior to the procedure and in 377 (51%) chronic BB therapy was discontinued. The rate of the composite periprocedural arrhythmic event was significantly higher among patients who stopped BB (20% vs. 13%, respectively, P = 0.018). Consistently, multivariate analysis showed that discontinuation of BB was associated with two-fold (P = 0.003) increase in the risk for periprocedural arrhythmic events (OR = 2.0; 95% CI 1.24-3.23; P = 0.004). The association between BB discontinuation and periprocedural arrhythmic events was consistent for the separate endpoints for HDAV and NOAF. Furthermore, the need for permanent pacemaker was significantly higher among patients who discontinued BB (20% vs. 13%; P = 0.018, respectively). CONCLUSIONS: Among patients undergoing TAVR who receive chronic BB therapy, BB discontinuation prior to the procedure is independently associated with a significant increase in the rate of adverse arrhythmic events, including HDAVB, NOAF, and the need for pacemaker implantation.


Assuntos
Antagonistas Adrenérgicos beta/administração & dosagem , Estenose da Valva Aórtica/cirurgia , Fibrilação Atrial/etiologia , Bloqueio Atrioventricular/etiologia , Substituição da Valva Aórtica Transcateter/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Bloqueio Atrioventricular/diagnóstico , Bloqueio Atrioventricular/fisiopatologia , Bloqueio Atrioventricular/terapia , Estimulação Cardíaca Artificial , Esquema de Medicação , Feminino , Humanos , Israel , Masculino , Marca-Passo Artificial , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
16.
Catheter Cardiovasc Interv ; 94(1): E44-E53, 2019 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-30549227

RESUMO

OBJECTIVE: To compare procedural outcomes of transcatheter aortic valve implantation (TAVI) patients who were implanted with older versus newer generation valves. BACKGROUND: The current evidence base for improved safety of the newer commercially available TAVI valves is limited. METHODS: A retrospective analysis of the Israeli multicenter TAVI registry was performed. Patients were stratified by valve generation of four commercially available devices: Edwards Sapien (ESX) Edwards Sapien S3 (ES3), Medtronic CoreValve (MCV), and Medtronic Evolut R (MER). RESULTS: The cohort consisted of 737 patients with new generation valves (NGVs; ES3 n = 223; MER n = 514) and 1,869 with old generation valves (OGVs; MCV n = 1,181; ESX n = 688). Device success rates were significantly higher in NGV (97.5 versus 95.4%), with less post-procedural paravalvular leak (3 versus 5.8%), and valve mal-positioning (1.2 versus 3.4%); all P-values<0.05. There were no differences in rates of permanent pacemaker implantation, stroke or acute kidney injury (AKI) of any stage between the groups, although stage ≥2 AKI was more prevalent in NGV. After adjustment to significant differences in baseline patient and procedural characteristics, device success was higher (OR 1.86, 95% confidence interval (CI) 1.09-3.18, P = 0.023) and the 1-month safety outcome was significantly lower (OR 0.72, 95% CI 0.55-0.96, P = 0.025) for NGV. Device success was driven mainly by improved rates of PVL of ES3, while the safety outcome was mainly driven by improved rates of life-threatening bleeding and valve mal-positioning of MER. CONCLUSION: As compared to OGV, use of NGV for TAVI was associated with higher rates of device success and lower rates of adverse events.


Assuntos
Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Próteses Valvulares Cardíacas , Desenho de Prótese , Substituição da Valva Aórtica Transcateter/instrumentação , Idoso , Idoso de 80 Anos ou mais , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/fisiopatologia , Feminino , Humanos , Israel , Masculino , Segurança do Paciente , Falha de Prótese , Estudos Retrospectivos , Fatores de Risco , Índice de Gravidade de Doença , Fatores de Tempo , Substituição da Valva Aórtica Transcateter/efeitos adversos , Resultado do Tratamento
17.
Catheter Cardiovasc Interv ; 92(4): E262-E270, 2018 10 01.
Artigo em Inglês | MEDLINE | ID: mdl-29027735

RESUMO

BACKGROUND: The last decade, regarded as the DES era in PCI, has witnessed significant advances in the management of coronary disease. We aimed to assess temporal trends in the practice and outcome of percutaneous coronary intervention (PCI) during the drug eluting stent (DES) era. METHODS: We analyzed 18,641 consecutive PCI's performed between January 2004 and December 2016, distinguished by procedural date (Q1 : 2004-2006, n = 4,865; Q2 : 2007-2009, n = 4,977; Q3 : 2010-2012, n = 4,230; Q4 : 2013-2016, n = 4,569). RESULTS: At presentation, mean patients age was 65 (±11) years and 22.8% were females. Over time, there was a rise in the relative number of octogenarians (Q1 : 10.7% vs Q4 : 15.5%, P < 0.001) and an increase in the burden of most comorbidities (e.g., left ventricular dysfunction ≥ moderate and chronic kidney disease, P < 0.001 for both). Despite a 2-fold increase in the rate of complex interventions, and a 3-fold increase in the rate of unprotected left-main angioplasty (P < 0.001 for both), the radial approach was increasingly adopted (Q1 : 2% to Q4 : 63.5%, P < 0.001). DES implantation increased from 43% to 83% at the expense of bare metal stent (BMS) application, and accompanied by drug coated balloon sprout to 1.8%, P < 0.001. Kaplan-Meier survival curves revealed a time-based enhanced outcome, with a decreased rate of death, MI, target vessel revascularization and CABG over the years. CONCLUSIONS: In the last decade, PCI has evolved to offer better outcome to more elderly, sicker patient population, with more complex coronary disease interventions. The shift to second generation DES and to enhanced PCI techniques may explain part of this progress.


Assuntos
Cardiologistas/tendências , Doença da Artéria Coronariana/terapia , Stents Farmacológicos/tendências , Intervenção Coronária Percutânea/tendências , Padrões de Prática Médica/tendências , Idoso , Idoso de 80 Anos ou mais , Angioplastia Coronária com Balão/instrumentação , Angioplastia Coronária com Balão/tendências , Doença da Artéria Coronariana/mortalidade , Feminino , Humanos , Israel , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/instrumentação , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese/tendências , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
18.
Catheter Cardiovasc Interv ; 89(7): 1292-1293, 2017 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-28612418

RESUMO

Delirium is a common condition among elderly patients, particularly those hospitalized following surgical procedures. A study indicates that delirium occurs in 1 out of 5 patients following TAVR and it was found to be associated with diminished survival, prolonged hospitalization, and increased healthcare utilization. Delirium is potentially preventable and treatable clinical syndrome.


Assuntos
Estenose da Valva Aórtica/cirurgia , Delírio , Próteses Valvulares Cardíacas , Substituição da Valva Aórtica Transcateter , Idoso , Valva Aórtica , Humanos
19.
Isr Med Assoc J ; 19(3): 172-176, 2017 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-28457096

RESUMO

BACKGROUND: The MGuard™ stent (InspireMD, Tel Aviv, Israel) is a bare metal mesh-covered stent, developed to prevent no-reflow phenomenon during percutaneous coronary intervention (PCI) of saphenous vein grafts (SVG) and acute myocardial infarction (MI), both associated with significant atherothrombotic lesions. OBJECTIVES: To report on local experience with patients treated with the MGuard stent until follow-up at 1 year. METHODS: We followed 163 consecutive patients who underwent MGuard stent deployment during the period 2009 to 2014 in a large tertiary cardiac center in central Israel. RESULTS: The MGuard stent was used in 67% of patients who underwent SVG-PCI while 33% were treated for native coronary artery disease, the majority during ST-elevation MI (STEMI). The mean age was 67 years and 83% were males. The clinical presentation was STEMI in 30% and non-STEMI/unstable angina in 60% of patients. Of the total number of patients, 47% had diabetes and 29% had chronic kidney disease. All patients had follow-up at 1 year. Mortality in the native group was 1.9% vs. 10% in the vein graft cohort. ST was 2% in both groups. The major adverse cardiac event (MACE) rates were 11% in the native artery and 29% in the vein graft group, mainly due to respective target lesion revascularization/target vessel revascularization rates of 6% and 7% in the native vessel group and 11% and 15% in the SVG group. CONCLUSIONS: In suitable patients undergoing SVG-PCI or native lesion intervention during acute MI, the MGuard stent is a viable treatment strategy. Its potential merits and limitations warrant further evaluation.


Assuntos
Vasos Coronários/cirurgia , Veia Safena/transplante , Stents , Idoso , Feminino , Seguimentos , Humanos , Masculino , Infarto do Miocárdio/cirurgia , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA