Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Odontology ; 111(3): 630-639, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-36460825

RESUMO

The purpose of this study was to investigate the process and derivation of the distribution of the sensory nerves that appear in the extraction socket and surrounding alveolar bone following tooth extraction. The right mandibular first molar of rats and periodontal ligament were extracted as a single mass, and the mandible was harvested after days 1, 3, 5, and 7 after extraction. Serial sections of 7 µm thickness were prepared for the proximal root (Section A), buccolingual root (Section B), and centrifugal root (Section C) of the first molar. H-E staining and immunohistochemical staining with anti-S100 antibody and anti-NF-L antibody were carried out. The presence of nerve fiber bundles in the blood clot was already evident on post-extraction day 3, and on post-extraction day 7. On day 3, the number of axons in Sections B and C had greatly decreased, indicating that, after extraction, the connection between peripheral nerve tissue and the trigeminal ganglion was temporarily markedly reduced in the region of the alveolar branch. Although the myelin sheaths were regenerating on day 5, the majority of the axons of the alveolar branches extending from the inferior alveolar nerve were seen to be extremely thin and scattered, despite their further regeneration. The above results suggest that the newly myelinated nerves are actually derived from the bone marrow to the extraction socket, so few nerves, rather than being derived from the alveolar branches that had innervated the extracted tooth.


Assuntos
Bainha de Mielina , Ligamento Periodontal , Animais , Ratos , Axônios , Nervo Mandibular , Dente Molar
2.
Int J Implant Dent ; 10(1): 24, 2024 May 09.
Artigo em Inglês | MEDLINE | ID: mdl-38722448

RESUMO

PURPOSE: The objective of the present study was to ascertain the effect of immediate occlusal loading after implant placement on osseointegration and the micro/nanostructure of the surrounding bone. METHODS: After extraction of a rat maxillary right second molar, an implant was placed immediately with initial fixation (2 N< ). The implants were placed to avoid occlusal loading due to mastication, and in the loaded group, a superstructure was fabricated and subjected to occlusal loading. Bone morphometry, collagen fiber anisotropy, and biological apatite (BAp) crystallite alignment were quantitatively evaluated in both groups after extraction and fixation of the jaw bone at Days 7 and 21 after surgery. RESULTS: Osseointegration was observed in both groups. Bone morphometry showed significant differences in bone volume, trabecular number, trabecular thickness and bone mineral density (BMD) at Days 21 postoperatively (P < 0.05). A significant difference was also found in the trabecular separation at Days 7 postoperatively (P < 0.05). In the evaluation of collagen fiber anisotropy, collagen fiber bundles running differently from the existing bone were observed in both groups. In terms of BAp crystallite alignment, a specific structure was observed in the reconstructed new bone after implantation, and preferential orientation of BAp crystallite alignment was observed in the longitudinal direction of the implants in the Day 21 postoperative loaded group. CONCLUSION: When sufficient initial fixation is achieved at the time of dental implant placement, then the applied masticatory load may contribute to rapidly achieving not only bone volume, but also adequate bone quality after implant placement.


Assuntos
Carga Imediata em Implante Dentário , Osseointegração , Animais , Ratos , Osseointegração/efeitos dos fármacos , Masculino , Densidade Óssea/fisiologia , Implantes Dentários , Ratos Wistar , Maxila/cirurgia , Colágeno/metabolismo , Microtomografia por Raio-X
3.
Int J Implant Dent ; 7(1): 89, 2021 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-34467429

RESUMO

BACKGROUND: There are many unclear points regarding local structural characteristics of the bone surrounding the implant reflecting the mechanical environment. PURPOSE: The purpose of this study is to quantitatively evaluate bone quality surrounding implants placed into the femurs of mice in an unloading model, and to determine the influence of the mechanical environment on bone quality. METHODS: Twenty 12-week-old male C57BL6/NcL mice (n = 5/group) were used as experimental animals. The mice were divided into two groups: the experimental group (n = 10) which were reared by tail suspension, and the control group (n = 10) which were reared normally. An implant was placed into the femur of a tail-suspended mouse, and after the healing period, they were sacrificed and the femur was removed. After micro-CT imaging, Villanueva osteochrome bone stain was performed. It was embedded in unsaturated polyester resin. The polymerized block was sliced passing through the center of the implant body. Next, 100-µm-thick polished specimens were prepared with water-resistant abrasive paper. In addition to histological observation, morphometric evaluation of cancellous bone was performed, and the anisotropy of collagen fibers and biological apatite (BAp) crystals was analyzed. RESULTS: As a result, the femoral cortical bone thickness and new peri-implant bone mass showed low values in the tail suspension group. The uniaxial preferential orientation of BAp c-axis in the femoral long axis direction in the non-implant groups, but biaxial preferential orientation of BAp c-axis along the long axis of implant and femoral long axis direction were confirmed in new bone reconstructed by implant placement. Collagen fiber running anisotropy and orientation of BAp c-axis in the bone surrounding the implant were not significantly different due to tail suspension. CONCLUSIONS: From the above results, it was clarified that bone formation occurs surrounding the implant even under extremely low load conditions, and bone microstructure and bone quality adapted to the new mechanical environment are acquired.


Assuntos
Implantes Dentários , Animais , Densidade Óssea , Osso e Ossos , Fêmur/diagnóstico por imagem , Masculino , Camundongos , Cauda
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA