Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 59
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Artigo em Inglês | MEDLINE | ID: mdl-38522865

RESUMO

Partial heart transplantation is the first clinically successful approach to deliver growing heart valve implants. To date, 13 clinical partial heart transplants have been performed. However, turning partial heart transplantation into a routine procedure that is available to all children who would benefit from growing heart valve implants poses formidable logistical challenges. Firstly, a supply for partial heart transplant donor grafts needs to be developed. This challenge is complicated by the scarcity of donor organs. Importantly, the donor pools for orthotopic heart transplants, partial heart transplants and cadaver homografts overlap. Secondly, partial heart transplants need to be allocated. Factors relevant for equitable allocation include the indication, anatomical fit, recipient clinical status and time on the wait list. Finally, partial heart transplantation will require regulation and oversight, which only recently has been undertaken by the Food and Drug Administration, which regulates human cellular and tissue-based products. Overcoming these challenges will require a change in the system. Once this is achieved, partial heart transplantation could open new horizons for children who require growing tissue implants.


Assuntos
Transplante de Coração , Doadores de Tecidos , Estados Unidos , Criança , Humanos , Valvas Cardíacas
2.
Cardiol Young ; : 1-6, 2024 Feb 27.
Artigo em Inglês | MEDLINE | ID: mdl-38410043

RESUMO

BACKGROUND: This study describes the illness burden in the first year of life for children with single-ventricle heart disease, using the metric of days alive and out of hospital to characterize morbidity and mortality. METHODS: This is a retrospective single-centre study of single-ventricle patients born between 2005 and 2021 who had their initial operation performed at our institution. Patient demographics, anatomical details, and hospitalizations were extracted from our institutional single-ventricle database. Days alive and out of hospital were calculated by subtracting the number of days hospitalized from number of days alive during the first year of life. A multivariable linear regression with stepwise variable selection was used to determine independent risk factors associated with fewer days alive and out of hospital. RESULTS: In total, 437 patients were included. Overall median number of days alive and out of hospital in the first year of life for single-ventricle patients was 278 days (interquartile range 157-319 days). In a multivariable analysis, low birth weight (<2.5kg) (b = -37.55, p = 0.01), presence of a dominant right ventricle (b = -31.05, p = 0.01), moderate-severe dominant atrioventricular valve regurgitation at birth (b = -37.65, p < 0.05), index hybrid Norwood operation (b = -138.73, p < 0.01), or index heart transplant (b = -158.41, p < 0.01) were all independently associated with fewer days alive and out of hospital. CONCLUSIONS: Children with single-ventricle heart defects have significant illness burden in the first year of life. Identifying risk factors associated with fewer days alive and out of hospital may aid in counselling families regarding expectations and patient prognosis.

3.
JAMA ; 331(1): 60-64, 2024 01 02.
Artigo em Inglês | MEDLINE | ID: mdl-38165407

RESUMO

Importance: The treatment of neonates with irreparable heart valve dysfunction remains an unsolved problem because there are no heart valve implants that grow. Therefore, neonates with heart valve implants are committed to recurrent implant exchanges until an adult-sized valve can fit. Objective: To deliver the first heart valve implant that grows. Design, Setting, and Participants: Case report from a pediatric referral center, with follow-up for more than 1 year. Participants were a recipient neonate with persistent truncus arteriosus and irreparable truncal valve dysfunction and a donor neonate with hypoxic-ischemic brain injury. Intervention: First-in-human transplant of the part of the heart containing the aortic and pulmonary valves. Main Outcomes and Measures: Transplanted valve growth and hemodynamic function. Results: Echocardiography demonstrated adaptive growth and excellent hemodynamic function of the partial heart transplant valves. Conclusions and Relevance: In this child, partial heart transplant delivered growing heart valve implants with a good outcome at age 1 year. Partial heart transplants may improve the treatment of neonates with irreparable heart valve dysfunction.


Assuntos
Transplante de Coração , Doenças das Valvas Cardíacas , Valvas Cardíacas , Persistência do Tronco Arterial , Adulto , Criança , Humanos , Recém-Nascido , Aorta/anormalidades , Aorta/diagnóstico por imagem , Aorta/cirurgia , Ecocardiografia , Transplante de Coração/métodos , Valvas Cardíacas/anormalidades , Valvas Cardíacas/diagnóstico por imagem , Valvas Cardíacas/cirurgia , Encaminhamento e Consulta , Doenças das Valvas Cardíacas/congênito , Doenças das Valvas Cardíacas/diagnóstico por imagem , Doenças das Valvas Cardíacas/cirurgia , Persistência do Tronco Arterial/diagnóstico por imagem , Persistência do Tronco Arterial/cirurgia , Valva Pulmonar/anormalidades , Valva Pulmonar/cirurgia
4.
Am Heart J ; 265: 143-152, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37572784

RESUMO

BACKGROUND: Stage 1 single ventricle palliation (S1P) has the longest length of stay (LOS) of all benchmark congenital heart operations. Center-level factors contributing to prolonged hospitalization are poorly defined. METHODS: We analyzed data from infants status post S1P included in the National Pediatric Cardiology Quality Improvement Collaborative Phase II registry. Our primary outcome was patient-level LOS with days alive and out of hospital before stage 2 palliation (S2P) used as a balancing measure. We compared patient and center-level characteristics across quartiles for median center LOS, and used multivariable regression to calculate center-level factors associated with LOS after adjusting for case mix. RESULTS: Of 2,510 infants (65 sites), 2037 (47 sites) met study criteria (61% male, 61% white, 72% hypoplastic left heart syndrome). There was wide intercenter variation in LOS (first quartile centers: median 28 days [IQR 19, 46]; fourth quartile: 62 days [35, 95], P < .001). Mortality prior to S2P did not differ across quartiles. Shorter LOS correlated with more pre-S2P days alive and out of hospital, after accounting for readmissions (correlation coefficient -0.48, P < .001). In multivariable analysis, increased use of Norwood with a right ventricle to pulmonary artery conduit (aOR 2.65 [1.1, 6.37]), shorter bypass time (aOR 0.99 per minute [0.98,1.0]), fewer additional cardiac operations (aOR 0.46 [0.22, 0.93]), and increased use of NG tubes rather than G tubes (aOR 7.03 [1.95, 25.42]) were all associated with shorter LOS centers. CONCLUSIONS: Modifiable center-level practices may be targets to standardize practice and reduce overall LOS across centers.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Cardiopatias Congênitas , Síndrome do Coração Esquerdo Hipoplásico , Procedimentos de Norwood , Lactente , Criança , Humanos , Masculino , Feminino , Tempo de Internação , Cardiopatias Congênitas/cirurgia , Resultado do Tratamento , Melhoria de Qualidade , Síndrome do Coração Esquerdo Hipoplásico/cirurgia , Sistema de Registros , Cuidados Paliativos , Estudos Retrospectivos
5.
Surg Endosc ; 36(7): 4828-4833, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-34755234

RESUMO

BACKGROUND: Recovery of preoperative ambulation levels 1 month after surgery represents an important patient-centered outcome. The objective of this study is to identify clinical factors associated with the inability to regain baseline preoperative ambulation levels 28 days postoperatively. METHODS: This is a prospective cohort study enrolling patients scheduled for elective inpatient abdominal operations. Daily ambulation (steps/day) was measured with a wristband accelerometer. Preoperative steps were recorded for at least 3 full calendar days before surgery. Postoperatively, daily steps were recorded for at least 28 days. The primary outcome was delayed recovery of ambulation, defined as inability to achieve 50% of preoperative baseline steps at 28 days postoperatively. RESULTS: A total of 108 patients were included. Delayed recovery (< 50% of baseline preoperative steps/day) occurred in 32 (30%) patients. Clinical factors associated with delayed recovery after multivariable logistic regression included longer operative time (OR 1.37, 95% CI 1.05-1.79), open operative approach (OR 4.87, 95% CI 1.64-14.48) and percent recovery on POD3 (OR 0.73, 95% CI 0.56-0.96). In addition, patients with delayed ambulation recovery had increased rates of postoperative complications (16% vs 1%, p < 0.01) and readmission (28% vs 5%, p < 0.01). CONCLUSION: After elective inpatient abdominal operations, nearly one in three patients do not recover 50% of their baseline preoperative steps 28 days postoperatively. Factors that can be used to identify these patients include longer operations, open operations and low ambulation levels on postoperative day #3. These data can be used to target rehabilitation efforts aimed at patients at greatest risk for poor ambulatory recovery.


Assuntos
Abdome , Procedimentos Cirúrgicos Eletivos , Abdome/cirurgia , Deambulação Precoce/efeitos adversos , Procedimentos Cirúrgicos Eletivos/efeitos adversos , Humanos , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/cirurgia , Período Pós-Operatório , Estudos Prospectivos , Caminhada
6.
Surg Endosc ; 35(7): 3796-3801, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-32804270

RESUMO

INTRODUCTION: More than 3 million patients have a cardiac implanted electronic device (CIED) such as a pacemaker or implanted cardioverter-defibrillator in the USA. These devices are susceptible to electromagnetic interference (EMI) leading to malfunction and injury. Radiofrequency energy, the most common modality for obtaining hemostasis during endoscopy, is the most common source of EMI. Few studies have evaluated the effect of endoscopic radiofrequency energy on CIEDs. We aim to characterize CIED dysfunction related to endoscopic procedures. We hypothesize that EMI from endoscopic energy can result in patient injury. METHODS: We queried the Manufacturer and User Facility Device Experience (MAUDE) database for CIED dysfunction related to electrosurgical devices over a 10-year period (2009-2019). CIED dysfunction events were identified using seven problem codes (malfunction, electromagnetic interference, ambient noise, pacing problem, over-sensing, inappropriate shock, defibrillation). These were cross-referenced for the terms "cautery, electrocautery, endoscopy, esophagus, colonoscopy, colon, esophagoscopy, and esophagogastroduodenoscopy." Reports were individually reviewed to confirm and characterize CIED malfunction due to an endoscopic procedure. RESULTS: A search for CIED dysfunction resulted in 43,759 reports. Three hundred and eleven reports (0.7%) were associated with electrocautery, and of these, 45 reports (14.5%) included endoscopy. Ten reports involving endoscopy (22%) specified upper (3, 7%) or lower (7, 16%) endoscopy while the remainder were non-specific. Twenty-six of reports involving endoscopy (58%) suffered injury because of CIED dysfunction: Of these, 17 (65%) received inappropriate shocks, 5 (19%) had pacing inhibition with bradycardia or asystole, 3 (12%) had CIED damage requiring explant and replacement, and 1 (4%) patient suffered ventricular tachycardia requiring hospital admission. CONCLUSION: The use of energy during endoscopy can cause dysfunction of CIEDs. This most commonly results in inappropriate defibrillation, symptomatic bradycardia, and asystole. Patients with CIEDs undergoing endoscopy should undergo pre- and post-procedure device interrogation and re-programming to avoid patient injury.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Preparações Farmacêuticas , Desfibriladores Implantáveis/efeitos adversos , Fenômenos Eletromagnéticos , Endoscopia , Humanos , Marca-Passo Artificial/efeitos adversos
7.
Surg Endosc ; 35(5): 2084-2090, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-32385708

RESUMO

INTRODUCTION: Stray energy transfer from monopolar radiofrequency energy during laparoscopy can be potentially catastrophic. Robotic surgery is increasing in popularity; however, the risk of stray energy transfer during robotic surgery is unknown. The purpose of this study was to (1) quantify stray energy transfer using robotic instrumentation, (2) determine strategies to minimize the transfer of energy, and (3) compare robotic stray energy transfer to laparoscopy. METHODS: In a laparoscopic trainer, a monopolar instrument (L-hook) was activated with DaVinci Si (Intuitive, Sunnyvale, CA) robotic instruments. A camera and assistant grasper were inserted to mimic a minimally invasive cholecystectomy. During activation of the L-hook, the non-electric tips of the camera and grasper were placed adjacent to simulated tissue (saline-soaked sponge). The primary outcome was change in temperature from baseline (°C) measured nearest the tip of the non-electric instrument. RESULTS: Simulated tissue nearest the robotic grasper increased an average of 18.3 ± 5.8 °C; p < 0.001 from baseline. Tissue nearest the robotic camera tip increased (9.0 ± 2.1 °C; p < 0.001). Decreasing the power from 30 to 15 W (18.3 ± 5.8 vs. 2.6 ± 2.7 °C, p < 0.001) or using low-voltage cut mode (18.3 ± 5.8 vs. 3.1 ± 2.1 °C, p < 0.001) reduced stray energy transfer to the robotic grasper. Desiccating tissue, in contrast to open air activation, also significantly reduced stray energy transfer for the grasper (18.3 ± 5.8 vs. 0.15 ± 0.21 °C, p < 0.001) and camera (9.0 ± 2.1 vs. 0.24 ± 0.34 °C, p < 0.001). CONCLUSIONS: Stray energy transfer occurs during robotic surgery. The assistant grasper carries the highest risk for thermal injury. Similar to laparoscopy, stray energy transfer can be reduced by lowering the power setting, utilizing a low-voltage cut mode instead of coagulation mode and avoiding open air activation. These practical findings can aid surgeons performing robotic surgery to reduce injuries from stray energy.


Assuntos
Procedimentos Cirúrgicos Robóticos/efeitos adversos , Procedimentos Cirúrgicos Robóticos/instrumentação , Ar , Queimaduras/etiologia , Transferência de Energia , Humanos , Laparoscopia/efeitos adversos , Laparoscopia/instrumentação , Temperatura
8.
Surg Endosc ; 35(6): 2981-2985, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-32591940

RESUMO

INTRODUCTION: Stray energy transfer from surgical monopolar radiofrequency energy instruments can cause unintended thermal injuries during laparoscopic surgery. Single-incision laparoscopic surgery transfers more stray energy than traditional laparoscopic surgery. There is paucity of published data concerning stray energy during single-incision robotic surgery. The purpose of this study was to quantify stray energy transfer during traditional, multiport robotic surgery (TRS) compared to single-incision robotic surgery (SIRS). METHODS: An in vivo porcine model was used to simulate a multiport or single-incision robotic cholecystectomy (DaVinci Si, Intuitive Surgical, Sunnyvale, CA). A 5 s, open air activation of the monopolar scissors was done on 30 W and 60 W coag mode (ForceTriad, Covidien-Medtronic, Boulder, CO) and Swift Coag effect 3, max power 180 W (VIO 300D, ERBE USA, Marietta, GA). Temperature of the tissue (°C) adjacent to the tip of the assistant grasper or the camera was measured with a thermal camera (E95, FLIR Systems, Wilsonville, OR) to quantify stray energy transfer. RESULTS: Stray energy transfer was greater in the SIRS setup compared to TRS setup at the assistant grasper (11.6 ± 3.3 °C vs. 8.4 ± 1.6 °C, p = 0.013). Reducing power from 60 to 30 W significantly reduced stray energy transfer in SIRS (15.3 ± 3.4 °C vs. 11.6 ± 3.3 °C, p = 0.023), but not significantly for TRS (9.4 ± 2.5 °C vs. 8.4 ± 1.6 °C, p = 0.278). The use of a constant voltage regulating generator also minimized stray energy transfer for both SIRS (0.7 ± 0.4 °C, p < 0.001) and TRS (0.7 ± 0.4 °C, p < 0.001). CONCLUSIONS: More stray energy transfer occurs during single-incision robotic surgery than multiport robotic surgery. Utilizing a constant voltage regulating generator minimized stray energy transfer for both setups. These data can be used to guide robotic surgeons in their use of safe, surgical energy.


Assuntos
Laparoscopia , Procedimentos Cirúrgicos Robóticos , Robótica , Ferida Cirúrgica , Animais , Transferência de Energia , Suínos
9.
J Surg Res ; 244: 368-373, 2019 12.
Artigo em Inglês | MEDLINE | ID: mdl-31323392

RESUMO

BACKGROUND: Emerging wearable technology has the potential to quantify both preoperative and postoperative patient activity. The purpose of this study was to characterize postoperative recovery trajectories for 1 mo after common surgical procedures. MATERIALS AND METHODS: Patients included were scheduled for common elective operations. A wearable activity device was worn for at least 3 d preoperatively and 28 d postoperatively. Postoperative steps per day were compared with preoperative baseline steps, with recovery trajectories reported as a percentage of patients' baseline values. Recovery trajectories were compared between groups based on admission type and operation type. RESULTS: Two hundred ten patients were enrolled, and 143 patients (68%) completed follow-up. Patients took a median 5342 steps per day preoperatively and had significantly decreased steps on the first postoperative day, including those undergoing inguinal hernia repair (22% of baseline steps, P < 0.001). Four weeks postoperatively, steps per day had not returned to baseline in patients undergoing minimally invasive abdominal (88% of baseline, P = 0.035), open abdominal (64% of baseline, P = 0.002), and thoracic (32% of baseline, P = 0.002) operations. All groups of patients showed a rapid recovery of steps during the first postoperative week, followed by a slower return to baseline. Recovery trajectories differed based on both admission type and operation type. CONCLUSIONS: Wearable activity monitors provide useful technology for quantification of postoperative activity recovery trajectories of steps per day in comparison to preoperative activity levels, with internal validity differentiating recovery trajectories grouping by broad categorization of operation type and by admission type. Activity recovery is a patient-centered outcome that can be used for counseling as well as for intervening to improve activity levels after surgery.


Assuntos
Recuperação de Função Fisiológica , Procedimentos Cirúrgicos Operatórios , Dispositivos Eletrônicos Vestíveis , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Projetos Piloto , Período Pós-Operatório
10.
Surg Endosc ; 32(2): 915-922, 2018 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-28779245

RESUMO

BACKGROUND: The purpose of this study is to present the largest reported series comparing open pancreaticoduodenectomy (OPD) to total laparoscopic pancreaticoduodenectomy (TLPD) in patients with ampullary neoplasms. METHODS: Patients undergoing OPD or TLPD for ampullary neoplasms from June 2012 to August 2016 were retrospectively identified. Perioperative outcomes were compared using a Wilcoxon rank-sum test, Student's t test, and Chi square analysis where appropriate. Kaplan-Meier estimates for progression-free survival (PFS) and overall survival (OS) were compared between the groups using the log-rank test. RESULTS: We identified 47 patients with ampullary neoplasms (adenocarcinoma n = 36, neuroendocrine tumor n = 7, undifferentiated n = 1, adenoma n = 3) undergoing OPD (n = 25) and TLPD (n = 22). The proportion of patients being offered TLPD has progressively increased every year over 5 years: 0% (2012) to 50% (2015). There were no differences in baseline variables between the two groups. TLPD was associated with less blood loss (300 vs. 500 mL, p < 0.001) and shorter operative times (314 vs. 359 min, p = 0.024). No patient required conversion to an open procedure and there were no perioperative deaths in either group. TLPD was associated with lower rates of intra-abdominal abscess (0 vs. 16.0%, p = 0.049), but there were no differences in rates of pancreatic fistula, bile leak, delayed gastric emptying, wound infection, length of stay, and readmission (all p > 0.05). Among patients with adenocarcinoma, there was no difference in pathological features between the two groups (p > 0.05) and all patients had negative margins. At a median follow up of 25 months, there was no difference in PFS or OS between the two groups. CONCLUSIONS: TLPD in patients with ampullary neoplasms results in improved perioperative outcomes while having equivalent short and long-term oncologic outcomes compared to the traditional open approach.


Assuntos
Adenocarcinoma/cirurgia , Adenoma/cirurgia , Ampola Hepatopancreática , Neoplasias do Ducto Colédoco/cirurgia , Laparoscopia/métodos , Tumores Neuroendócrinos/cirurgia , Pancreaticoduodenectomia/métodos , Adenocarcinoma/mortalidade , Adenoma/mortalidade , Adulto , Idoso , Neoplasias do Ducto Colédoco/mortalidade , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Tumores Neuroendócrinos/mortalidade , Duração da Cirurgia , Estudos Retrospectivos , Análise de Sobrevida , Resultado do Tratamento
11.
Surg Endosc ; 32(5): 2239-2248, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29067580

RESUMO

INTRODUCTION: The purpose of the study is to compare perioperative and survival outcomes in elderly patients undergoing laparoscopic pancreaticoduodenectomy (LPD) to those undergoing open pancreaticoduodenectomy (OPD). METHODS: Patients aged ≥ 75 years with pancreatic adenocarcinoma undergoing LPD or OPD were identified from the NCDB (2010-2013). Baseline characteristics and perioperative outcomes were compared using a χ 2 and Student's t test. The Kaplan-Meier method was used to generate survival curves, and differences were tested using a log-rank test. A multivariate cox proportional hazard model was applied to estimate the hazard ratio (HR) of LPD on overall survival (OS). RESULTS: We identified 1768 patients aged ≥ 75 years who underwent LPD (n = 248, 14.0%) or OPD (n = 1520, 86.0%). The majority of patients in the LPD group had their surgery at facilities performing less than 5 LPDs per year (n = 165, 66.5%). 90-day mortality was significantly lower in the LPD compared to the OPD (7.2 vs. 12.2%, p = 0.049). The laparoscopic conversion rate was 30% (n = 74) and was associated with higher readmission rates (13.5 vs. 8.1%), 30-day mortality (8.0 vs. 3.8%), and 90-day mortality (10.4 vs. 6.0%), but these did not reach statistical significance. Median OS was significantly longer in the LPD group (19.8 vs. 15.6 months, p = 0.022). After adjusting for patient and tumor-related characteristics, there was a trend towards improved survival in the LPD group (HR 0.85, 95% CI 0.69-1.03). CONCLUSION: The vast majority of the NCDB participating facilities perform less than 5 LPD cases per year, which was associated with an increased risk of perioperative mortality. Overall 90-day mortality was significantly lower in the LPD group and there was a trend towards improved OS in the LPD group compared to the OPD group after adjusting for patient and tumor-related characteristics. Studies with increased sample size and longer follow-up are needed before definitive conclusions can be made.


Assuntos
Adenocarcinoma/cirurgia , Laparoscopia/estatística & dados numéricos , Neoplasias Pancreáticas/cirurgia , Pancreaticoduodenectomia/métodos , Idoso , Feminino , Humanos , Tempo de Internação , Masculino , Estudos Retrospectivos , Resultado do Tratamento
12.
J Vasc Surg ; 66(4): 1037-1047.e7, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28433338

RESUMO

OBJECTIVE: Previous randomized controlled trials have defined specific size thresholds to guide surgical decision-making in patients presenting with an abdominal aortic aneurysm (AAA). With recent advances in endovascular techniques, the anatomic considerations of AAA repair are rapidly changing. Our specific aims were to evaluate the most recent national population data to compare anatomic differences and perioperative outcomes in patients with AAA. METHODS: The American College of Surgeons National Surgical Quality Improvement Program was queried from 2011 to 2015 using the targeted vascular public use file. Patients with AAA undergoing elective open or endovascular repair were included. Risk factors and outcomes were stratified by size and divided into quartiles for categorical comparison. A logistic regression model was used to compare the impact of size on morbidity and mortality with each technique. A risk adjustment model used all preoperative criteria to generate observed and expected values for open and endovascular repair. RESULTS: There were 10,026 patients who underwent elective AAA repair, 8182 (81.6%) endovascular and 1844 (18.4%) open. Repairs were divided into density quartiles for a logistic analysis: smallest quartile, 3.5 to 5 cm; second quartile, 5.01 to 5.5 cm; third quartile, 5.51 to 6.2 cm; and largest quartile, >6.2 cm. Patients with larger aneurysms (>6.2 cm) were more likely to be male, to have a dependent functional status, and to have increased blood urea nitrogen concentration and American Society of Anesthesiologists score (P < .05). Larger aneurysms had longer operative time (162 vs 135 minutes) and greater extension toward the renal and iliac vessels (all P < .05). Risk adjustment revealed an observed/expected morbidity plot that favored endovascular repair throughout the size range but confirmed lack of size effect within the open repair category. The adjusted increase in morbidity with endovascular repair is 9.7% per centimeter increase in size of AAA. These trends remained true with an infrarenal subgroup analysis. CONCLUSIONS: Patients with a larger AAA have comorbidities and anatomic factors associated with a more difficult repair. The higher morbidity seen with larger aneurysms represents both anatomic and patient factors but seems to have a greater impact on endovascular repairs. However, endovascular repair still results in fewer near-term complications than open repair across all size strata.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/efeitos adversos , Procedimentos Endovasculares/efeitos adversos , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Distribuição de Qui-Quadrado , Comorbidade , Bases de Dados Factuais , Procedimentos Cirúrgicos Eletivos , Feminino , Humanos , Modelos Logísticos , Masculino , Estudos Retrospectivos , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos
13.
J Surg Res ; 219: 103-107, 2017 11.
Artigo em Inglês | MEDLINE | ID: mdl-29078867

RESUMO

BACKGROUND: Energy-based devices are used in nearly every laparoscopic operation. Radiofrequency energy can transfer to nearby instruments via antenna and capacitive coupling without direct contact. Previous studies have described inadvertent energy transfer through bundled cords and nonelectrically active wires. The purpose of this study was to describe a new mechanism of stray energy transfer from the monopolar instrument through the operating surgeon to the laparoscopic telescope and propose practical measures to decrease the risk of injury. METHODS: Radiofrequency energy was delivered to a laparoscopic L-hook (monopolar "bovie"), an advanced bipolar device, and an ultrasonic device in a laparoscopic simulator. The tip of a 10-mm telescope was placed adjacent but not touching bovine liver in a standard four-port laparoscopic cholecystectomy setup. Temperature increase was measured as tissue temperature from baseline nearest the tip of the telescope which was never in contact with the energy-based device after a 5-s open-air activation. RESULTS: The monopolar L-hook increased tissue temperature adjacent to the camera/telescope tip by 47 ± 8°C from baseline (P < 0.001). By having an assistant surgeon hold the camera/telescope (rather than one surgeon holding both the active electrode and the camera/telescope), temperature change was reduced to 26 ± 7°C (P < 0.001). Alternative energy devices significantly reduced temperature change in comparison to the monopolar instrument (47 ± 8°C) for both the advanced bipolar (1.2 ± 0.5°C; P < 0.001) and ultrasonic (0.6 ± 0.3°C; P < 0.001) devices. CONCLUSIONS: Stray energy transfers from the monopolar "bovie" instrument through the operating surgeon to standard electrically inactive laparoscopic instruments. Hand-to-hand coupling describes a new form of capacitive coupling where the surgeon's body acts as an electrical conductor to transmit energy. Strategies to reduce stray energy transfer include avoiding the same surgeon holding the active electrode and laparoscopic camera or using alternative energy devices.


Assuntos
Queimaduras por Corrente Elétrica/prevenção & controle , Eletrocirurgia/métodos , Transferência de Energia , Laparoscopia/métodos , Traumatismos Ocupacionais/prevenção & controle , Cirurgiões , Animais , Queimaduras por Corrente Elétrica/etiologia , Bovinos , Eletrocirurgia/instrumentação , Mãos , Humanos , Laparoscopia/instrumentação , Fígado/cirurgia , Traumatismos Ocupacionais/etiologia
14.
J Surg Oncol ; 115(8): 1033-1044, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28334436

RESUMO

BACKGROUND AND OBJECTIVES: Neoadjuvant chemoradiation for rectal cancer is associated with lower local recurrence rates. The objective of this study is to assess the impact of neoadjuvant therapy on perioperative complications in patients with rectal cancer. METHODS: Using the ACS-NSQIP database (2005-2012), a propensity score was used to match 3592 patients with rectal cancer receiving neoadjuvant therapy to 3592 patients undergoing surgery alone. The association between neoadjuvant chemoradiation and perioperative outcomes was evaluated. RESULTS: Among all patients, overall morbidity was significantly higher in the neoadjuvant therapy group (n = 1170, 29.9%) compared to the surgery alone (n = 2350, 26.4%; P < 0.0001), but 30-day mortality was lower in the neoadjuvant group (n = 27, 0.7%) compared to the surgery alone group (n = 112, 1.3%; P = 0.0043). However, in propensity-matched patients, there was no difference in overall morbidity (OR 0.912, 95% CI 0.825-1.008) or 30-day mortality (OR 0.639, 95% CI 0.38-1.05). Overall morbidity and 30-day mortality were 29.3% (n = 1054) and 0.7% (n = 25) in the neoadjuvant group, respectively, compared to 31.3% (n = 1124) and 1.1% (n = 39) in the surgery alone group, respectively. CONCLUSION: Patients with newly diagnosed rectal cancer could be evaluated for neoadjuvant therapy prior to surgical resection without the fear of upfront therapy causing a significant increase in perioperative complications.


Assuntos
Quimiorradioterapia Adjuvante , Terapia Neoadjuvante , Complicações Pós-Operatórias/epidemiologia , Neoplasias Retais/tratamento farmacológico , Neoplasias Retais/radioterapia , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Neoplasias Retais/mortalidade , Estudos Retrospectivos , Taxa de Sobrevida , Resultado do Tratamento
15.
Surg Endosc ; 31(10): 3912-3921, 2017 10.
Artigo em Inglês | MEDLINE | ID: mdl-28281115

RESUMO

BACKGROUND: Recent American College of Surgeons National Surgical Quality Improvement Project (ACS-NSQIP)-based evidence indicates that laparoscopic (LAP) colectomy results in improved outcomes compared to hand-assisted laparoscopic (HAL) colectomy in the general population. Previous comparative studies demonstrated that the HAL technique offers distinct advantages for obese patients. The aim of this study was to perform comparative analyses of HAL and LAP colectomy and low anterior resection (LAR) in obese patients. METHODS: The ACS-NSQIP public use file and targeted colectomy dataset, 2012-2014, were utilized for patients undergoing colectomy and LAR. Only obese patients (BMI > 30) and laparoscopic or hand-assisted operations were included. Patient, operation, and outcome variables were compared in two separate cohorts: colectomy and LAR. Bivariate analysis compared the approaches, followed by multivariable regression. RESULTS: Of 9610 obese patients included, HAL and LAP colectomy were performed in 3126 and 3793 patients and LAR in 1431 and 1260 patients, respectively. In comparison to LAP colectomy, HAL colectomy patients had increased comorbidities including class 2 and 3 obesity. HAL colectomy was associated with higher overall morbidity (20 vs. 16%, p < 0.001), infectious complications (10.2 vs. 7.7%, p < 0.001), anastomotic leaks (3.0 vs. 2.2%, p = 0.03), and ileus (11 vs. 8%, p < 0.001). Multivariate analysis indicated that overall morbidity (OR 1.27, 95% CI 1.11-1.44), infectious complications (OR 1.35, 95% CI 1.14-1.59), and ileus (OR 1.33, 95% CI 1.12-1.57) were each increased in the HAL colectomy cohort but not different for HAL and LAP LAR. CONCLUSIONS: In comparison to LAP colectomy, the HAL technique is used more often in obese patients with an increased operative risk profile. While inherent bias and unmeasured variables limit the analysis, the available data indicate that the HAL technique is associated with increased perioperative morbidity. Alternatively, HAL and LAP LAR are performed in obese patients with a similar risk profile and result in similar postoperative outcomes.


Assuntos
Colectomia/métodos , Doenças do Colo/cirurgia , Laparoscopia/métodos , Obesidade/cirurgia , Adulto , Idoso , Colectomia/efeitos adversos , Doenças do Colo/complicações , Bases de Dados Factuais , Feminino , Humanos , Laparoscopia/efeitos adversos , Tempo de Internação/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Obesidade/complicações , Complicações Pós-Operatórias/epidemiologia , Estudos Retrospectivos , Taxa de Sobrevida , Resultado do Tratamento
16.
Surg Endosc ; 31(10): 3946-3951, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28205029

RESUMO

INTRODUCTION: Endoscopy is the standard tool for the evaluation and treatment of gastrointestinal disorders. While the risk of complication is low, the use of energy devices can increase complications by 100-fold. The mechanism of increased injury and presence of stray energy is unknown. The purpose of the study was to determine if stray energy transfer occurs during endoscopy and if so, to define strategies to minimize the risk of energy complications. METHODS AND PROCEDURES: A gastroscope was introduced into the stomach of an anesthetized pig. A monopolar generator delivered energy for 5 s to a snare without contacting tissue or the endoscope itself. The endoscope tip orientation, energy device type, power level, energy mode, and generator type were varied to mimic in vivo use. The primary outcome (stray current) was quantified as the change in tissue temperature (°C) from baseline at the tissue closest to the tip of the endoscope. Data were reported as mean ± standard deviation. RESULTS: Using the 60 W coag mode while changing the orientation of the endoscope tip, tissue temperature increased by 12.1 ± 3.5 °C nearest the camera lens (p < 0.001 vs. all others), 2.1 ± 0.8 °C nearest the light lens, and 1.7 ± 0.4 °C nearest the working channel. Measuring temperature at the camera lens, reducing power to 30 W (9.5 ± 0.8 °C) and 15 W (8.0 ± 0.8 °C) decreased stray energy transfer (p = 0.04 and p = 0.002, respectively) as did utilizing the low-voltage cut mode (6.6 ± 0.5 °C, p < 0.001). An impedance-monitoring generator significantly decreased the energy transfer compared to a standard generator (1.5 ± 3.5 °C vs. 9.5 ± 0.8 °C, p < 0.001). CONCLUSION: Stray energy is transferred within the endoscope during the activation of common energy devices. This could result in post-polypectomy syndrome, bleeding, or perforation outside of the endoscopist's view. Decreasing the power, utilizing low-voltage modes and/or an impedance-monitoring generator can decrease the risk of complication.


Assuntos
Queimaduras por Corrente Elétrica/patologia , Ablação por Cateter/efeitos adversos , Endoscópios , Endoscopia/efeitos adversos , Transferência de Energia/fisiologia , Complicações Intraoperatórias/patologia , Animais , Ablação por Cateter/instrumentação , Impedância Elétrica/efeitos adversos , Endoscópios/efeitos adversos , Modelos Animais , Suínos
17.
JTCVS Tech ; 24: 150-163, 2024 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-38835569

RESUMO

Objective: In select patients with borderline ventricular hypoplasia, we adopted a strategy of initial single-ventricle palliation followed by staged or direct biventricular conversion by 2 years of age. Methods: Between 2018 and 2023, 14 newborns with borderline hypoplastic heart disease deemed high risk for primary biventricular repair underwent palliative procedures as a neonate/infant, followed by staged or direct biventricular conversion. Results: Of the 14 patients, 6 had borderline left ventricles and 8 had borderline right ventricles. Index neonatal operations were performed in 12 patients and included the Norwood operation (n = 5), pulmonary artery band (n = 3), ductal stent (n = 3), and hybrid Norwood (n = 1). Five patients underwent direct biventricular conversion, and the remaining 9 patients underwent staged ventricular recruitment operations at a mean age of 6 months (range, 3-11 months). Ventricular recruitment operations included atrial septation with or without ventricular rehabilitation, atrioventricular valve repair, or outflow tract operations. At a mean duration of 8 months (range, 4-10 months) after ventricular recruitment, there was a significant increase in chamber volume, aortic valve, and mitral valve size in patients with borderline left ventricles, and a normalization of the right ventricle:left ventricle end-diastolic volume ratio in patients with borderline right ventricles. To date, 13 of 14 patients have undergone successful biventricular conversion at a mean age of 16 months (range, 4-31 months). Conclusions: In select newborns with borderline hypoplastic heart disease, single-ventricle palliation followed by staged or direct biventricular conversion may increase infant survival while allowing for early attainment of a biventricular circulation.

18.
World J Pediatr Congenit Heart Surg ; 15(3): 303-312, 2024 05.
Artigo em Inglês | MEDLINE | ID: mdl-38263731

RESUMO

Background: To develop a more holistic measure of congenital heart center performance beyond mortality, we created a composite "textbook outcome" (TO) for the Glenn operation. We hypothesized that meeting TO would have a positive prognostic and financial impact. Methods: This was a single center retrospective study of patients undergoing superior cavopulmonary connection (bidirectional Glenn or Kawashima ± concomitant procedures) from 2005 to 2021. Textbook outcome was defined as freedom from operative mortality, reintervention, 30-day readmission, extracorporeal membrane oxygenation, major thrombotic complication, length of stay (LOS) >75th percentile (17d), and mechanical ventilation duration >75th percentile (2d). Multivariable logistic regression and Cox proportional hazards modeling were used. Results: Fifty-one percent (137/269) of patients met TO. Common reasons for TO failure were prolonged LOS (78/132, 59%) and ventilator duration (67/132, 51%). In multivariable analysis, higher weight [odds ratio, OR: 1.44 (95% confidence interval, CI: 1.15-1.84), P = .002] was a positive predictor of TO achievement while right ventricular dominance [OR 0.47 (0.27-0.81), P = .007] and higher preoperative pulmonary vascular resistance [OR 0.58 (0.40-0.82), P = .003] were negative predictors. After controlling for preoperative factors and excluding operative mortalities, TO achievement was independently associated with a decreased risk of death over long-term follow-up [hazard ratio: 0.50 (0.25-0.99), P = .049]. Textbook outcome achievement was also associated with lower direct cost of care [$137,626 (59,333-167,523) vs $262,299 (114,200-358,844), P < .0001]. Conclusion: Achievement of the Glenn TO is associated with long-term survival and lower costs and can be predicted by certain risk factors. As outcomes continue to improve within congenital heart surgery, operative mortality will become a less informative metric. Textbook outcome analysis may represent a more balanced measure of a successful outcome.


Assuntos
Técnica de Fontan , Cardiopatias Congênitas , Ventrículos do Coração , Humanos , Estudos Retrospectivos , Feminino , Masculino , Cardiopatias Congênitas/cirurgia , Cardiopatias Congênitas/mortalidade , Ventrículos do Coração/cirurgia , Ventrículos do Coração/anormalidades , Técnica de Fontan/mortalidade , Técnica de Fontan/métodos , Lactente , Pré-Escolar , Derivação Cardíaca Direita/mortalidade , Resultado do Tratamento , Coração Univentricular/cirurgia , Coração Univentricular/mortalidade
19.
Sci Rep ; 14(1): 12318, 2024 05 29.
Artigo em Inglês | MEDLINE | ID: mdl-38811656

RESUMO

Partial heart transplantation (PHT) is a novel surgical approach that involves transplantation of only the part of the heart containing a valve. The rationale for this approach is to deliver growing heart valve implants that reduce the need for future re-operations in children. However, prior to clinical application of this approach, it was important to assess it in a preclinical model. To investigate PHT short-term outcomes and safety, we performed PHT in a piglet model. Yorkshire piglets (n = 14) were used for PHT of the pulmonary valve. Donor and recipient pairs were matched based on blood types. The piglets underwent PHT at an average age of 44 days (range 34-53). Post-operatively, the piglets were monitored for a period of two months. Of the 7 recipient piglets, one mortality occurred secondary to anesthesia complications while undergoing a routine echocardiogram on post-operative day 19. All piglets had appropriate weight gain and laboratory findings throughout the post-operative period indicating a general state of good health and rehabilitation after undergoing PHT. We conclude that PHT has good short-term survival in the swine model. PHT appears to be safe for clinical application.


Assuntos
Transplante de Coração , Animais , Transplante de Coração/métodos , Transplante de Coração/efeitos adversos , Suínos , Valva Pulmonar/cirurgia , Modelos Animais , Modelos Animais de Doenças
20.
World J Pediatr Congenit Heart Surg ; : 21501351241245115, 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38780414

RESUMO

Partial heart transplantation is a new approach to deliver growing heart valve implants. Partial heart transplants differ from heart transplants because only the part of the heart containing the necessary heart valve is transplanted. This allows partial heart transplants to grow, similar to the valves in heart transplants. However, the transplant biology of partial heart transplantation remains unexplored. This is a critical barrier to progress of the field. Without knowledge about the specific transplant biology of partial heart transplantation, children with partial heart transplants are empirically treated like children with heart transplants because the valves in heart transplants are known to grow. In order to progress the field, an animal model for partial heart transplantation is necessary. Here, we contribute our surgical protocol for partial heart transplantation in growing piglets. All aspects of partial heart transplantation, including the donor procedure, the recipient procedure, and recipient perioperative care are described in detail. There are important nuances in the conduct of virtually all aspects of open heart surgery that differs in piglets from humans. Our surgical protocol, which is based on our experience with 34 piglets, will allow other investigators to leverage our experience to seek fundamental knowledge about the nature of partial heart transplants. This is significant because the partial heart transplant model in piglets is complex and very resource intensive.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA