Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 35
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Exp Eye Res ; 235: 109615, 2023 10.
Artigo em Inglês | MEDLINE | ID: mdl-37586456

RESUMO

The most common and chronic ocular problem of aging is dry eye disease (DED) and the associated condition of meibomian gland dysfunction (MGD). The resident ocular surface bacteria may have a role in maintaining homeostasis and perturbation may contribute to disease development. The aim of this study was to compare the microbiomes of the conjunctiva and eyelid margin in humans with mild and moderate DED and controls using 16 S rRNA gene sequencing. The conjunctiva and lid margin of three cohorts (N = 60; MGD, MGD with lacrimal dysfunction [MGD + LD] and controls) were swabbed bilaterally three times over three months. Microbial communities were analysed by extracting DNA and sequencing the V3-V4 region of the 16 S ribosomal RNA gene using the Illumina MiSeq platform. Sequences were quality filtered, clustered into amplicon sequence variants (ASVs) using UNOISE algorithm and taxonomically classified using a Bayesian Last Common Ancestor (BCLA) algorithm against the GTDB 2207 database. The overall microbial communities of the MGD, MGD + LD and control groups were significantly different from each other (P = 0.001). The MGD and MGD + LD dry eye groups showed greater variability between individuals compared to the control (PERMDISP, P < 0.01). There was decreased richness and diversity in females compared to males for the conjunctiva (P < 0.04) and eyelid margin (P < 0.018). The conjunctiva in the MGD + LD group had more abundant Pseudomonas azotoformans, P. oleovorans and Caballeronia zhejiangensis compared to MGD and control (P < 0.05), while the MGD group had more abundant Corynebacterium macginleyi and C. kroppenstedtii compared to control (P < 0.05). The lid margin in MGD was more abundant in C. macginleyi, C. accolens, and C. simulans compared to the MGD + LD and control (P < 0.05). There were differences in the overall microbial community composition and certain taxa, including increased levels of lipophilic bacteria, on the conjunctiva and eyelid margin in mild to moderate DED/MGD compared to controls. DED/MGD was also associated with a reduced bacterial richness and diversity in females.


Assuntos
Síndromes do Olho Seco , Doenças Palpebrais , Disfunção da Glândula Tarsal , Microbiota , Humanos , Masculino , Feminino , Glândulas Tarsais , Teorema de Bayes , Bactérias/genética , Lágrimas
2.
Exp Eye Res ; 220: 109130, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35654116

RESUMO

The human face/head supports a highly diverse population of microorganisms across a diverse range of microhabitats. This biogeographical diversity has given rise to selection pressure resulting in the formation of distinct bacterial communities between sites. This review investigates the similarity and differences of microbiomes across the different biogeographies of the human face and discusses a potential pathway for microbial circulation within individuals and within a population to maintain microbiome niches and diversity.


Assuntos
Microbiota , Bactérias/genética , Olho , Humanos , RNA Ribossômico 16S
3.
Exp Eye Res ; 207: 108609, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33932398

RESUMO

Animal models are a critical element of ocular surface research for investigating therapeutic drops, surgical implants, and infection research. This study was a comparative analysis of the microbial communities on conjunctival tissue samples from humans compared to several commonly used laboratory animals (BALB/c mice, New Zealand white rabbits and IMVS colored stock guinea pigs). Microbial communities were analyzed by extracting total DNA from conjunctival tissue and sequencing the 16 S rRNA gene using the Illumina MiSeq platform. Sequences were quality filtered using the UNOISE pipeline in USEARCH and taxonomically classified using GTDB database. Sequences associated with blank extraction and sampling negative controls were removed with the decontam R software package prior to downstream analysis. There was a difference in the diversity measures of richness (P = 0.0124) and Shannon index (P = 0.0002) between humans and rabbits but not between human, mouse and guinea pigs. There was a difference between the human and any animal for bacterial community structure (P = 0.006). There was a higher degree of similarity between the bacterial composition of the human and mouse samples with each dominated by the phyla Proteobacteria and Firmicutes. The use of mouse models may be more appropriate for studies investigating changes to the ocular microbiome due to interventions such as application of antibiotics due to greater similarities in bacterial community structure and composition to humans.


Assuntos
Bactérias/isolamento & purificação , Túnica Conjuntiva/microbiologia , DNA Bacteriano/genética , Microbiota/genética , Adolescente , Adulto , Animais , Feminino , Cobaias , Sequenciamento de Nucleotídeos em Larga Escala , Humanos , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Pessoa de Meia-Idade , Modelos Animais , RNA Ribossômico 16S/genética , Coelhos , Análise de Sequência de DNA , Adulto Jovem
4.
Eye Contact Lens ; 45(2): 88-92, 2019 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-30080693

RESUMO

AIM: A series of proof-of-principle extended wear (EW) contact lens studies were conducted to assess what effect different interventions had on adverse events (AEs). Comparative analysis of AEs across studies was conducted to determine whether some interventions were more effective at reducing inflammatory AEs. METHOD: Multiple logistic regression analysis of AEs from 30-day EW studies each with a different intervention including (1) nightly replacement (NR) of lenses, (2) morning replacement (MR) of lenses, (3) instillation of prophylactic antibiotic drops (AB) each morning/evening, (4) daily lens cleaning (LC) each morning. All studies conducted at the same site using same lens type (lotrafilcon A) and EW schedule. RESULTS: Comparison of the different interventions to the individual control groups showed no difference in significant corneal infiltrative event (CIE) or mechanical events. Replacing lenses nightly, during an EW schedule, had the highest incidence of significant CIEs (4.9% [NR] vs. 2.5% [MR] vs. 1.8% [AB] vs. 0% [LC]); however, adjusted logistic regression analysis of the combined control data compared with the individual interventions showed no difference in significant CIEs (P=0.086) or mechanical AEs (P=0.140). CONCLUSIONS: Replacing lenses each night seemed to be inferior compared with the other interventions of replacing lenses each morning, daily lens cleaning, and daily antibiotic drop instillation during EW. The results of the collective studies and additional analysis suggest that overnight wear of contact lenses seems to create an adverse environment that remains, despite the various interventions intended to improve this adverse environment.


Assuntos
Antibacterianos/administração & dosagem , Lentes de Contato de Uso Prolongado/efeitos adversos , Infecções Oculares Bacterianas/prevenção & controle , Equipamentos Descartáveis , Infecções Oculares Bacterianas/epidemiologia , Feminino , Seguimentos , Humanos , Incidência , Masculino , Soluções Oftálmicas , Estudos Prospectivos , Adulto Jovem
5.
Eye Contact Lens ; 44 Suppl 1: S30-S37, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-27341089

RESUMO

OBJECTIVES: To investigate whether adaptation of accommodative responses occurred in non-presbyopic myopes fitted with four multifocal contact lens (MFCL) designs. METHODS: Prospective, subject-masked clinical investigation comprising 40 experienced myopic lens wearers (18-25 years) fitted bilaterally with single-vision (SV) control lens (Air Optix Aqua [Alcon, Fort Worth, TX]) and randomized to two of four test MFCL (Proclear MFCL [Distance and Near] [CooperVision, Pleasanton, CA], Air Optix Aqua MFCL, Purevision MFCL [Bausch & Lomb, Rochester, NY]). Lenses were dispensed on a daily wear basis and worn for a minimum of 8 (maximum 14) days over three assessment visits, with a 1-week wash out between stages. Paraxial curvature matched spherical equivalent (M) was measured with lenses on eye using the BHVI-EyeMapper with an internal movable fixation target positioned at target vergences of +1.00 diopter (D) (fogging) and -2.00 to -5.00 in 1.00 D steps (accommodative stimuli). Accommodative facility was assessed by several flips of ±2.00 D/min (cycles/min) at 33 cm and horizontal phoria with a Howell phoria card at distance (3 m) and near (33 cm). RESULTS: For center-distance MFCL (Proclear D), the spherical equivalent (M) at all near vergences became significantly more negative at the follow-up visits compared with the dispensing visit (P<0.029). For all center-near MFCLs and SV lens, M remained invariant during the adaptation period, however (P≥0.267). At distance, M became significantly less minus with Air Optix Aqua MFCL over time (P=0.049). Accommodative facility increased over the three assessment visits for participants wearing Air Optix Aqua SV, Air Optix Aqua MFCL, and PureVision MFCL (P=0.003). Distance and near horizontal phoria remained stable over the three assessment visits for all lens types (P≥0.181). CONCLUSIONS: Adaptation differences were not consistently found for static accommodative measures gauged by M, as measured with lenses on eye, and phoria but were found in dynamic measures (facility), perhaps indicating some learning effects. Accommodative adaptation seems unlikely to occur with long-term MFCL in non-presbyopes.


Assuntos
Acomodação Ocular/fisiologia , Lentes de Contato Hidrofílicas , Miopia/reabilitação , Adulto , Estudos Cross-Over , Feminino , Humanos , Masculino , Miopia/fisiopatologia , Estudos Prospectivos , Acuidade Visual/fisiologia , Adulto Jovem
6.
Optom Vis Sci ; 92(2): 157-66, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25951477

RESUMO

PURPOSE: The purpose of the study was to assess what effect daily cleaning of contact lenses with a multipurpose disinfection solution (MPDS), during 30 nights extended wear, would have on contact lens-related adverse events. METHODS: This was a prospective, open-label, randomized, controlled, parallel-group, 3-month clinical study in which 193 participants were dispensed with lotrafilcon A silicone hydrogel lenses for a 30-day extended-wear schedule and with lenses replaced monthly. Participants were randomized to a control or test group. Test subjects were required to remove lenses daily after waking, clean them with the MPDS, and reinsert the lenses. Control subjects wore lenses without removal for 30 days extended wear. Handling-related lens contamination was assessed at the baseline visit. RESULTS: There was no significant difference between the test and control groups for the incidence of significant corneal infiltrative events (1.3 vs. 4.9%, p = 0.368), total corneal infiltrative events (2.6 vs. 4.9%, p = 0.682), or mechanical events (1.3 vs. 2.5%, p = 1.00). The test group had greater corneal staining (p < 0.047) and fewer mucin balls (p = 0.033). Handling-related lens contamination (unworn lenses) resulted in isolation of Gram-positive bacteria from 92.5% of test lenses compared with 87.5% of control lenses (p = 0.712). Gram-negative bacteria were isolated from 5% of test subjects compared with 2.5% of control subjects (p = 1.00). Fungus was isolated from 2.5% of subjects in both the test and control groups (p = 1.00). CONCLUSIONS: The intervention of daily morning cleaning of the lens surface with an MPDS during extended wear did not significantly influence the incidence of adverse events.


Assuntos
Soluções para Lentes de Contato/uso terapêutico , Lentes de Contato de Uso Prolongado/efeitos adversos , Lentes de Contato de Uso Prolongado/microbiologia , Infecções Oculares Bacterianas/etiologia , Fungos/isolamento & purificação , Bactérias Gram-Negativas/isolamento & purificação , Bactérias Gram-Positivas/isolamento & purificação , Adolescente , Contagem de Colônia Microbiana , Feminino , Desinfecção das Mãos , Humanos , Hidrogéis , Incidência , Masculino , Estudos Prospectivos , Silicones
7.
Optom Vis Sci ; 91(5): 570-81, 2014 May.
Artigo em Inglês | MEDLINE | ID: mdl-24759327

RESUMO

PURPOSE: Covalent immobilization of antimicrobial peptide melimine onto contact lenses can produce broad-spectrum antimicrobial lenses. The purpose of this study was to investigate the performance of melimine-coated contact lenses in an animal model and human clinical trial. METHODS: Melimine was covalently attached onto the surface of contact lenses via EDC (1-ethyl-3-[3-dimethylaminopropyl] carbodiimide hydrochloride) coupling. A rabbit model of daily contralateral wear of lenses for 22 days was conducted to assess the lens safety. A prospective, randomized, double-masked, one-day human clinical trial was used to evaluate subjective responses and ocular physiology during contralateral wear of melimine-coated (test) and uncoated (control) lenses. Delayed reactions were monitored during follow-up visits after 1 and 4 weeks. Ex vivo retention of antimicrobial activity of worn lenses was assessed by reduction in numbers of viable Pseudomonas aeruginosa and Staphylococcus aureus. RESULTS: Melimine-coated lenses produced no ocular signs or symptoms that would indicate cytotoxicity during the lens wear of rabbits. No histological changes were found in rabbit corneas. During the human trial, no differences were observed in wettability, surface deposition, lens-fitting centration, movement, tightness, and corneal coverage between test and control lenses (p > 0.05). There were no significant differences in bulbar, limbal, or palpebral redness or conjunctival staining (p > 0.05). Mean corneal (extent, depth, and type) staining was higher for test lenses compared with that for control lenses (p < 0.05). There was no significant difference in subjective responses for lens comfort, dryness, and awareness (p > 0.05). No delayed reactions were associated with the test lenses. Worn test lenses retained more than 1.5 log inhibition against both bacterial types. CONCLUSIONS: Melimine-coated contact lenses were worn safely by humans. However, they were associated with higher corneal staining. The melimine-coated lenses retained high antibacterial activity after wear.


Assuntos
Anti-Infecciosos/uso terapêutico , Peptídeos Catiônicos Antimicrobianos/uso terapêutico , Materiais Revestidos Biocompatíveis/uso terapêutico , Lentes de Contato Hidrofílicas , Modelos Animais de Doenças , Adulto , Animais , Anti-Infecciosos/efeitos adversos , Peptídeos Catiônicos Antimicrobianos/efeitos adversos , Materiais Revestidos Biocompatíveis/efeitos adversos , Contagem de Colônia Microbiana , Córnea/fisiologia , Método Duplo-Cego , Feminino , Humanos , Masculino , Teste de Materiais , Metacrilatos , Estudos Prospectivos , Ajuste de Prótese , Pseudomonas aeruginosa/efeitos dos fármacos , Coelhos , Staphylococcus aureus/efeitos dos fármacos , Molhabilidade
8.
Optom Vis Sci ; 91(1): 13-23, 2014 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-24240353

RESUMO

PURPOSE: Overnight lens wear is associated with increased lens contamination and risk of developing a corneal infiltrate or infectious event. Antibacterial lenses have been proposed as a potential strategy for reducing lens contamination. A proof-of-principle study was conducted to investigate what effect control of potential pathogens, through the use of antibiotic eye drops, would have on the incidence of corneal infiltrative events (CIEs) and on the ocular microbiota and lens contamination. METHODS: This is a prospective, open-label, controlled, parallel-group, 1-month clinical study in which 241 subjects were dispensed with lotrafilcon A silicone hydrogel lenses for 30 days of continuous wear. Subjects were randomized into either test (moxifloxacin 0.5%) or control (rewetting solution) group. One drop was instilled into each eye on waking and before sleeping, while lenses were on-eye. Follow-ups were conducted after one night and 1 month. Lid margin swabs were taken at baseline and at 1 month and worn lenses were aseptically collected at 1 month. RESULTS: The incidence of CIEs was not significantly different between the test (2.6%) and control (3.9%) groups (p = 0.72). Microorganism levels from the test group swabs were significantly lower than those from the control group (p = 0.001). Gram-positive bacteria were less frequently recovered from lower lid swabs from the test group (39.6% vs. 66.0% [p < 0.001], test vs. control, respectively) or from contact lens samples (1.9% vs. 10.5% [p = 0.015], test vs. control, respectively), but there was no difference in gram-negative bacteria (GNB). Corneal infiltrative events were associated with higher levels of lens contamination (p = 0.014) and contamination of lenses with GNB (CIE: 7.3% vs. 0.6% [p = 0.029], GNB contamination vs. no GNB contamination, respectively). DISCUSSION: Twice-daily antibiotic instillation during continuous wear of lenses did not significantly influence the rate of inflammatory events. Corneal infiltrative events were associated with higher levels of lens contamination in general and with contamination by GNB specifically.


Assuntos
Antibacterianos/uso terapêutico , Compostos Aza/uso terapêutico , Lentes de Contato de Uso Prolongado/microbiologia , Úlcera da Córnea/microbiologia , Contaminação de Equipamentos/estatística & dados numéricos , Infecções Oculares Bacterianas/microbiologia , Microbiota/efeitos dos fármacos , Quinolinas/uso terapêutico , Adulto , Contaminação de Equipamentos/prevenção & controle , Pálpebras/microbiologia , Feminino , Fluoroquinolonas , Bactérias Gram-Positivas/isolamento & purificação , Humanos , Hidrogéis , Masculino , Microbiota/fisiologia , Pessoa de Meia-Idade , Moxifloxacina , Soluções Oftálmicas , Estudos Prospectivos , Silicones , Adulto Jovem
9.
Clin Exp Optom ; : 1-6, 2024 May 16.
Artigo em Inglês | MEDLINE | ID: mdl-38755754

RESUMO

CLINICAL RELEVANCE: The behaviour of human telomerase reverse transcriptase (hTERT) in tears reflects its role in maintaining the ocular surface homoeostasis, as it is increased after the initial fitting of contact lenses and post-overnight lid closure. BACKGROUND: hTERT has been shown to respond to cellular stress in neurodegenerative diseases and to enhance axonal regeneration after peripheral axotomy in an animal model. This work investigated whether the behaviour of hTERT in the tear film reflects ocular surface inflammation and neuronal changes in the presence of dry eye disease. METHODS: Flush tears were collected from 18 participants with dry eye disease (14 females, 4 males, mean age 34.7 ± 5.2 years) and from 18 healthy participants without dry eye disease (8 females, 10 males, mean age 31.9 ± 5.8 years). Dry eye disease status was defined using the TFOS DEWS II diagnostic criteria. hTERT levels in tears were measured using enzyme-linked immunosorbent assays. Confocal images were taken at the level of the subbasal nerve plexus at the central cornea and at the inferior whorl, and the densities of corneal immune cells were evaluated as well as corneal nerve morphology metrics using a fully automated technique (University of Manchester, United Kingdom). RESULTS: In participants with dry eye disease, hTERT levels were significantly higher compared to controls (median [interquartile range]: 434 [320-600] ng/ml, and 184 [42-390] ng/ml, respectively, p = 0.01). Increased nerve fibre width at the inferior whorl, was seen in those with dry eyes (0.0219 [0.0214-0.0236] mm/mm compared to controls 0.0217 [0.0207 0.0222] p < 0.001), but no significant differences were found in the density of corneal immune cells. CONCLUSIONS: hTERT levels were elevated in participants with dry eye disease, and this was accompanied by increased nerve thickness in the inferior cornea. The hTERT response may reflect the stress induced to the ocular surface and corneal nerves due to having dry eye disease.

10.
Front Cell Infect Microbiol ; 14: 1346821, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38694515

RESUMO

Background: Microbial keratitis is one of the leading causes of blindness globally. An overactive immune response during an infection can exacerbate damage, causing corneal opacities and vision loss. This study aimed to identify the differentially expressed genes between corneal infection patients and healthy volunteers within the cornea and conjunctiva and elucidate the contributing pathways to these conditions' pathogenesis. Moreover, it compared the corneal and conjunctival transcriptomes in corneal-infected patients to cytokine levels in tears. Methods: Corneal and conjunctival swabs were collected from seven corneal infection patients and three healthy controls under topical anesthesia. RNA from seven corneal infection patients and three healthy volunteers were analyzed by RNA sequencing (RNA-Seq). Tear proteins were extracted from Schirmer strips via acetone precipitation from 38 cases of corneal infection and 14 healthy controls. The cytokines and chemokines IL-1ß, IL-6, CXCL8 (IL-8), CX3CL1, IL-10, IL-12 (p70), IL-17A, and IL-23 were measured using an antibody bead assay. Results: A total of 512 genes were found to be differentially expressed in infected corneas compared to healthy corneas, with 508 being upregulated and four downregulated (fold-change (FC) <-2 or > 2 and adjusted p <0.01). For the conjunctiva, 477 were upregulated, and 3 were downregulated (FC <-3 or ≥ 3 and adjusted p <0.01). There was a significant overlap in cornea and conjunctiva gene expression in patients with corneal infections. The genes were predominantly associated with immune response, regulation of angiogenesis, and apoptotic signaling pathways. The most highly upregulated gene was CXCL8 (which codes for IL-8 protein). In patients with corneal infections, the concentration of IL-8 protein in tears was relatively higher in patients compared to healthy controls but did not show statistical significance. Conclusions: During corneal infection, many genes were upregulated, with most of them being associated with immune response, regulation of angiogenesis, and apoptotic signaling. The findings may facilitate the development of treatments for corneal infections that can dampen specific aspects of the immune response to reduce scarring and preserve sight.


Assuntos
Túnica Conjuntiva , Córnea , Citocinas , Ceratite , Lágrimas , Transcriptoma , Humanos , Lágrimas/metabolismo , Citocinas/metabolismo , Citocinas/genética , Córnea/metabolismo , Córnea/imunologia , Feminino , Masculino , Pessoa de Meia-Idade , Adulto , Túnica Conjuntiva/metabolismo , Túnica Conjuntiva/imunologia , Ceratite/genética , Ceratite/imunologia , Ceratite/metabolismo , Idoso , Perfilação da Expressão Gênica
11.
Cont Lens Anterior Eye ; 46(6): 102060, 2023 12.
Artigo em Inglês | MEDLINE | ID: mdl-37714745

RESUMO

PURPOSE: To investigate the behaviour of telomerase reverse transcriptase (hTERT) in the tears of healthy neophyte contact lenses-wearing individuals during the sleep/wake cycle. A subsequent aim was to investigate whether hTERT behaviour was associated with inflammatory mediators interleukin-6 (IL-6) and tumour necrosis factor-alpha (TNF-α) in tears. METHODS: Flush tears were collected from 19 healthy, non-contact lens-wearing participants (11 males, 8 females, mean age 31.9 ± 5.7 years), before and during contact lens wear. Tears were collected at noon, before sleep and upon awakening and levels of hTERT, IL-6 and TNF-α, were determined using enzyme-linked immunosorbent assays (ELISA). RESULTS: hTERT levels (median [interquartile range]) during contact lens wear were significantly higher before sleep (436.5 (263.9 - 697.7) ng/ml compared to the same time point without contact lenses (256.1 (0.0 - 590.9) ng/ml (p = 0.01). There was no difference between contact lens wear (851.3 [353.2 - 2109.9]) ng/ml, and no wear (1091.0 [492.3 - 3045.4]) ng/ml, upon awakening (p = 0.94). A significant increase was found upon awakening compared to before sleep, irrespective of the presence of a contact lens (p = 0.02). IL-6 and TNF-α levels in tears were below the limit of detection. CONCLUSIONS: The study showed that hTERT increases after a contact lens is placed on the eye, but this change is small, compared to the impact of overnight eye closure. Taken together with the lack of responses of the inflammatory markers monitored at the same time points, this may suggest that hTERT can respond both to low-level stress stimuli acting on the ocular surface, and to situations where inflammation is a likely factor.


Assuntos
Lentes de Contato de Uso Prolongado , Lentes de Contato Hidrofílicas , Lentes de Contato , Masculino , Feminino , Humanos , Adulto , Interleucina-6 , Fator de Necrose Tumoral alfa , Lentes de Contato/efeitos adversos , Sono , Lágrimas
12.
Biofouling ; 28(7): 697-709, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22784025

RESUMO

This study was designed to use multiple reaction monitoring (MRM) for accurate quantification of contact lens protein deposits. Worn lenses used with a multipurpose disinfecting solution were collected after wear. Individual contact lenses were extracted and then digested with trypsin. MRM in conjunction with stable-isotope-labeled peptide standards was used for protein quantification. The results show that lysozyme was the major protein detected from both lens types. The amount of protein extracted from contact lenses was affected by the lens material. Except for keratin-1 (0.83 ± 0.61 vs 0.77 ± 0.20, p = 0.81) or proline rich protein-4 (0.11 ± 0.04 vs 0.15 ± 0.12, p = 0.97), the amounts of lysozyme, lactoferrin, or lipocalin-1 extracted from balafilcon A lenses (12.9 ± 9.01, 0.84 ± 0.50 or 2.06 ± 1.6, respectively) were significantly higher than that extracted from senofilcon A lenses (0.88 ± 0.13, 0.50 ± 0.10 or 0.27 ± 0.23, respectively) (p < 0.05). The amount of protein extracted from contact lenses was dependent on both the individual wearer and the contact lens material. This may have implications for the development of clinical responses during lens wear for different people and with different types of contact lenses. The use of MRM-MS is a powerful analytical tool for the quantification of specific proteins from single contact lenses after wear.


Assuntos
Lentes de Contato , Proteínas do Olho/metabolismo , Hidrogéis/metabolismo , Marcação por Isótopo/métodos , Géis de Silicone/metabolismo , Silicones/metabolismo , Cromatografia Líquida/métodos , Proteínas do Olho/isolamento & purificação , Humanos , Queratina-1/isolamento & purificação , Queratina-1/metabolismo , Lactoferrina/isolamento & purificação , Lactoferrina/metabolismo , Limite de Detecção , Espectrometria de Massas/métodos , Muramidase/isolamento & purificação , Muramidase/metabolismo , Peptídeos/metabolismo , Proteômica
13.
Optom Vis Sci ; 89(3): 326-35, 2012 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-22246331

RESUMO

PURPOSE: Bacterial contamination of the contact lens surface has been demonstrated to cause corneal infiltrative events. A reduction in the rate of bacterially driven corneal infiltrative events associated with lens wear is one of the major goals of the contact lens industry. There is a concern over the potential of any antimicrobial strategy that there will be unwanted changes to the ocular microbiota or the development of resistance to the antimicrobial. The aim of this study was to investigate the effect of prophylactic topical antibiotic instillation during continuous wear of silicone hydrogel lenses on the normal ocular microbiota, the throat microbiota, and the ocular physiology. METHODS: Forty-two male subjects were dispensed with lotrafilcon A silicone hydrogel contact lenses for a 3-month, 30 night continuous wear, monthly replacement trial. Subjects were randomized into either tobramycin 0.3% (test) or saline (control) drop group. Two drops were instilled into each eye on waking and before sleep. At monthly visits, lenses were collected aseptically, and ocular and throat swabs were performed, followed by standard microbial recovery and identifications. Any corneal infiltrative event at scheduled or unscheduled visits was recorded. RESULTS: Numbers of microbes recovered from eye swabs from the tobramycin (test) group were significantly lower than the control (p = 0.01). Gram-positive cocci were recovered less frequently from the test group (p = 0.001). There were no significant differences in the numbers and types of microbes recovered from lens samples, or the contamination rate of the lenses between the two groups. There were no changes in the numbers of fungi or bacteria from throat swabs. There was no evidence of changes to resistance profile of microbes in the throat. More eye swabs from the test group (68.5%) were culture-negative than swabs from control (46.5%; p = 0.002). The test group had less corneal staining superiorly (0.0 ± 0.0 vs. 0.3 ± 0.4; p = 0.025) but increased bulbar redness (2.2 ± 0.5 vs. 1.5 ± 0.4; p < 0.001) at the 3-month visit only, compared with control group. CONCLUSIONS: Overall, there appeared to be a minimal safety risk with 3-month's prophylactic antibiotic drop use during continuous wear of silicone hydrogel lenses. Clinically, antibiotic drop use induced a mild to moderate increase in bulbar redness by the 3-month time-point. Antibiotic use reduced microbiota on lids but did not affect the microbiota of the throat or change resistance to tobramycin.


Assuntos
Antibacterianos/administração & dosagem , Lentes de Contato de Uso Prolongado/microbiologia , Córnea/efeitos dos fármacos , Infecções Oculares Bacterianas/prevenção & controle , Ceratite/prevenção & controle , Metagenoma/efeitos dos fármacos , Silicones , Adulto , Córnea/microbiologia , Córnea/fisiopatologia , Infecções Oculares Bacterianas/microbiologia , Infecções Oculares Bacterianas/fisiopatologia , Feminino , Seguimentos , Humanos , Ceratite/microbiologia , Ceratite/fisiopatologia , Masculino , Soluções Oftálmicas , Estudos Prospectivos , Fatores de Tempo , Tobramicina/administração & dosagem , Resultado do Tratamento
14.
Optom Vis Sci ; 89(12): 1674-81, 2012 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-23160441

RESUMO

PURPOSE: Compared with daily disposable wear schedule, continuous wear (CW) or extended wear of contact lenses has been associated with an increased risk of developing an ocular infection. Proof-of-principle studies were conducted to investigate the impact of daily replacement of lenses on the rate of contact lens-related ocular adverse events (AEs) during 30-night CW. METHODS: A total of 215 subjects were dispensed with silicone hydrogel lenses on a 30-night CW schedule but replaced lenses daily either each night before sleeping (n = 178 eyes) or each morning after waking (n = 252 eyes). Scheduled clinic visits were conducted at 1 week and 1 month. Neophytes were required to complete 1 week of daily wear before commencing CW. A historical control (n = 191 eyes) using the same site, subject demographics, and visit schedule but monthly lens replacement was used for AE rates. RESULTS: Logistic regression analysis showed a significant reduction in mechanical AEs (0.8 vs 5.2%, p = 0.01) and overall AEs (inflammatory and mechanical events) (4.0 vs 8.9%, p = 0.04) when lenses were replaced each morning compared with being replaced monthly. Estimation of handling-related lens contamination of unworn lenses in a subgroup of subjects showed isolation of Staphylococcus aureus from the lenses of 35% of subjects, and 65% of subjects had more than 1000 colony-forming units per lens of gram-positive bacterial contamination. CONCLUSIONS: Morning lens replacement during CW reduced mechanical and overall ocular AEs. Replacing lenses at night had no beneficial effects perhaps because the benefit of a fresh lens at night might be partially negated by contamination of the contact lens caused by lens handling before overnight eye closure. Contact lens wearers on an extended wear or CW schedule should be advised to minimize lens handling before sleep to reduce the risk of complications.


Assuntos
Lentes de Contato de Uso Prolongado/efeitos adversos , Lentes de Contato de Uso Prolongado/microbiologia , Equipamentos Descartáveis , Infecções Oculares Bacterianas/epidemiologia , Staphylococcus aureus/crescimento & desenvolvimento , Contagem de Colônia Microbiana , Infecções Oculares Bacterianas/etiologia , Infecções Oculares Bacterianas/prevenção & controle , Feminino , Seguimentos , Humanos , Incidência , Índia/epidemiologia , Masculino , Estudos Retrospectivos , Adulto Jovem
15.
Optom Vis Sci ; 89(8): 1095-106, 2012 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-22820469

RESUMO

PURPOSE: The objective of this study was to determine the bacterial adhesion to various silicone hydrogel lens materials and to determine whether lens wear modulated adhesion. METHODS: Bacterial adhesion (total and viable cells) of Staphylococcus aureus (31, 38, and ATCC 6538) and Pseudomonas aeruginosa (6294, 6206, and GSU-3) to 10 commercially available different unworn and worn silicone hydrogel lenses was measured. Results of adhesion were correlated to polymer and surface properties of contact lenses. RESULTS: S. aureus adhesion to unworn lenses ranged from 2.8 × 10 to 4.4 × 10 colony forming units per lens. The highest adhesion was to lotrafilcon A lenses, and the lowest adhesion was to asmofilcon A lenses. P. aeruginosa adhesion to unworn lenses ranged from 8.9 × 10 to 3.2 × 10 colony forming units per lens. The highest adhesion was to comfilcon A lenses, and the lowest adhesion was to asmofilcon A and balafilcon A lenses. Lens wear altered bacterial adhesion, but the effect was specific to lens and strain type. Adhesion of bacteria, regardless of genera/species or lens wear, was generally correlated with the hydrophobicity of the lens; the less hydrophobic the lens surface, the greater the adhesion. CONCLUSIONS: P. aeruginosa adhered in higher numbers to lenses in comparison with S. aureus strains, regardless of the lens type or lens wear. The effect of lens wear was specific to strain and lens. Hydrophobicity of the silicone hydrogel lens surface influenced the adhesion of bacterial cells.


Assuntos
Aderência Bacteriana/fisiologia , Lentes de Contato Hidrofílicas/microbiologia , Elastômeros de Silicone , Staphylococcus epidermidis/fisiologia , Adulto , Contagem de Colônia Microbiana , Feminino , Humanos , Masculino , Propriedades de Superfície
16.
Curr Eye Res ; 47(9): 1239-1245, 2022 09.
Artigo em Inglês | MEDLINE | ID: mdl-35726825

RESUMO

Purpose: To measure variation in corneal dendritic cell density, and percentage of mature to total dendritic cells, in healthy individuals during the sleep/wake cycle.Methods: Using in vivo confocal microscopy, images of the subbasal nerve plexus were captured from 19 healthy, noncontact lens wearing participants. The central cornea and inferior whorl were imaged three times (midday, before sleep, upon awakening). Dendritic cell counts from the images were categorized according to perceived maturity (immature vs mature). Dendritic cell density and percentage of mature to total cells were compared between time points.Result: The median and interquartile range (IQR) of total dendritic cell density in the central cornea was 32.0 (7.0-131.3) cells/mm2 at midday, 37.1 (8.2-103.9) cells/mm2 before sleep, and 19.5 (7.0-83.2) cells/mm2 on awakening. Corresponding values for immature cells were 28.1 (5.8-112.5) cells/mm2, 22.3 (7.4-84.0) cells/mm2 and 18.0 (2.9-64.8) cells/mm2, and for mature cells, 3.1 (0.0-6.6) cells/mm2, 2.0 (0.8-16.8) cells/mm2, and 1.6 (0.2-8.2) cells/mm2. At the inferior whorl, total dendritic cell density was 38.5 (18.4-84.5) cells/mm2, 34.4 (9.4-82.3) cell/mm2, and 32.3 (15.2-96.1) cells/mm2. Immature cell density was 32.8 (18.4-80.9) cells/mm2, 34.4 (8.6-81.0) cells/mm2, and 32.3 (12.6-78.5) cells/mm2. Mature cell density was 1.6 (0.0-6.3) cells/mm2, 1.6 (0.0-3.1) cells/mm2, and 1.8 (0.0-6.3) cells/mm2. There was no significant difference between time points for total cell density (p > 0.05), but the percentage of mature cells upon awakening was significantly greater, compared to midday, at the central cornea (p = 0.02).Conclusion: In healthy individuals, overall corneal dendritic cell density is reasonably constant during the sleep/wake cycle, but the relative number of mature cells tends to increase overnight.


Assuntos
Ritmo Circadiano , Córnea , Contagem de Células , Córnea/inervação , Células Dendríticas , Humanos , Microscopia Confocal/métodos , Nervo Oftálmico
17.
Clin Exp Optom ; 105(2): 166-176, 2022 03.
Artigo em Inglês | MEDLINE | ID: mdl-34592130

RESUMO

The tear film is a thin, moist layer covering the ocular surface and is laden with proteins, peptides, lipids, mucins, electrolytes and cellular debris which function to maintain the healthy status of the ocular surface. In many cases of ocular or systemic disease, the integrity of this layer is changed and/or the balance of its constituents is disturbed. Since tears are easy and quick to collect and can be stored for long periods, they have the potential to be a valuable source of information relevant to many disease states. The purpose of this review is to collate information on the known biomarkers of systemic disease that have been identified in tears. The range of conditions covered includes diabetes mellitus, diabetic retinopathy, diabetic peripheral neuropathy, multiple sclerosis, Parkinson's disease, Alzheimer's disease, migraine, systemic sclerosis, cystic fibrosis, thyroid disorders and cancer.


Assuntos
Doenças não Transmissíveis , Biomarcadores/metabolismo , Olho/metabolismo , Humanos , Mucinas/metabolismo , Lágrimas/metabolismo
18.
Cont Lens Anterior Eye ; 45(4): 101494, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-34315655

RESUMO

PURPOSE: To determine if there is diurnal variation in gene expression in normal healthy conjunctival cells. METHODS: Bulbar conjunctival swab samples were collected from four healthy subjects in the morning and evening of the same day. The two swab samples were taken from one eye of each participant, with a minimum of five hours gap between the two samples. RNA was extracted and analysed using RNA sequencing (RNA-Seq). RESULTS: A total of 121 genes were differentially expressed between the morning and the evening conjunctival samples, of which 94 genes were upregulated in the morning, and 27 genes were upregulated in the evening. Many of the genes that were upregulated in the morning were involved in defence, cell turnover and regulation of gene expression, while the genes upregulated in the evening were involved in signalling and mucin production. CONCLUSIONS: This study has identified several genes whose expression changes over the course of the day. Knowledge of diurnal variations of conjunctival gene expression provides an insight into the regulatory status of the healthy eye and provides a baseline for examining changes during ocular surface disease.


Assuntos
Túnica Conjuntiva , Mucinas , Ritmo Circadiano/genética , Expressão Gênica , Humanos , Mucinas/metabolismo
19.
Optom Vis Sci ; 88(8): 950-8, 2011 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-21552177

RESUMO

PURPOSE: To examine the effect of cholesterol on the adhesion of bacteria to silicone hydrogel contact lenses. METHODS: Contact lenses, collected from subjects wearing Acuvue Oasys or PureVision lenses, were extracted in chloroform:methanol (1:1, v/v) and amount of cholesterol was estimated by thin-layer chromatography. Unworn lenses were soaked in cholesterol, and the numbers of Pseudomonas aeruginosa strains or Staphylococcus aureus strains that adhered to the lenses were measured. Cholesterol was tested for effects on bacterial growth by incubating bacteria in medium containing cholesterol. RESULTS: From ex vivo PureVision lenses, 3.4 ± 0.3 µg/lens cholesterol was recovered, and from Acuvue Oasys lenses, 2.4 ± 0.2 to 1.0 ± 0.1 µg/lens cholesterol was extracted. Cholesterol did not alter the total or viable adhesion of any strain of P. aeruginosa or S. aureus (p > 0.05). However, worn PureVision lenses reduced the numbers of viable cells of P. aeruginosa (5.8 ± 0.4 log units) compared with unworn lenses (6.4 ± 0.2 log units, p = 0.001). Similarly, there were fewer numbers of S. aureus 031 adherent to worn PureVision (3.05 ± 0.8 log units) compared with unworn PureVision (4.6 ± 0.3 log units, p = 0.0001). Worn Acuvue Oasys lenses did not affect bacterial adhesion. Cholesterol showed no effect on the growth of any test strain. CONCLUSIONS: Although cholesterol has been shown to adsorb to contact lenses during wear, this lipid does not appear to modulate bacterial adhesion to a lens surface.


Assuntos
Aderência Bacteriana/efeitos dos fármacos , Colesterol/farmacologia , Lentes de Contato de Uso Prolongado/microbiologia , Pseudomonas aeruginosa/crescimento & desenvolvimento , Staphylococcus aureus/crescimento & desenvolvimento , Absorção , Cromatografia em Camada Fina , Contagem de Colônia Microbiana , Estudos Cross-Over , Humanos , Pseudomonas aeruginosa/efeitos dos fármacos , Staphylococcus aureus/efeitos dos fármacos
20.
Ocul Surf ; 19: 169-175, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-32497656

RESUMO

PURPOSE: The ocular surface microbiota are recognised as one of causative microorganisms in post-procedural endophthalmitis but in many cases the vitreous tap is culture negative. This study investigated bacterial contamination of intravitreal (IVT) needles using multiple approaches covering culturing, 16S rRNA gene sequencing, fluorescent in situ hybridisation (FISH) and scanning electron microscopy (SEM). METHODS: IVT needles were obtained immediately after injection from patients undergoing treatment for predominantly age-related macular degeneration. Eighteen needles were analysed by culturing on chocolate blood agar. In addition, 40 needles were analysed by extracting DNA and paired-end sequencing of the 16S rRNA gene. Sequences were quality filtered (USEARCH), taxonomically classified (SILVA) and contaminant filtered (DECONTAM). Nine needles were analysed by either FISH using the bacterial probe EUB338 or SEM. RESULTS: Using culturing, three bacteria were identified from 5 of 18 needles (28%) - Kocuria kristinae, Staphylococcus hominis and Sphingomonas paucimobilis. The negative control needles showed no growth. Following rigorous data filtering, bacterial community analysis using 16S rRNA gene sequencing showed the presence of predominantly Corynebacterium but also Pseudomonas, Acinetobacter, Sphingomonas, Staphylococcus and Bacillus on the needles. Cocci-shaped cells in a tetrad formation were observed using FISH, while SEM images showed cocci-shaped bacteria in pairs and irregular tetrads. CONCLUSIONS: The study showed evidence for a large diversity of bacteria on IVT needles and visually confirmed their adherence. The diversity was similar to that found on the ocular surface and in conjunctival tissue. This suggests the risk of exogenous endophthalmitis remains even with sterilization of the conjunctival surface.


Assuntos
Microbiota , Agulhas , Humanos , Micrococcaceae , RNA Ribossômico 16S/genética , Sphingomonas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA