Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 17 de 17
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
Phys Rev Lett ; 132(19): 195001, 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38804956

RESUMO

Experiments were performed on laser wakefield acceleration in the highly nonlinear regime. With laser powers P<250 TW and using an initial spot size larger than the matched spot size for guiding, we were able to accelerate electrons to energies E_{max}>2.5 GeV, in fields exceeding 500 GV m^{-1}, with more than 80 pC of charge at energies E>1 GeV. Three-dimensional particle-in-cell simulations show that using an oversized spot delays injection, avoiding beam loss as the wakefield undergoes length oscillation. This enables injected electrons to remain in the regions of highest accelerating fields and leads to a doubling of energy gain as compared to results from using half the focal length with the same laser.

2.
Phys Rev Lett ; 129(24): 244801, 2022 Dec 09.
Artigo em Inglês | MEDLINE | ID: mdl-36563240

RESUMO

We report on a novel, noninvasive method applying Thomson scattering to measure the evolution of the electron beam energy inside a laser-plasma accelerator with high spatial resolution. The determination of the local electron energy enabled the in-situ detection of the acting acceleration fields without altering the final beam state. In this Letter we demonstrate that the accelerating fields evolve from (265±119) GV/m to (9±4) GV/m in a plasma density ramp. The presented data show excellent agreement with particle-in-cell simulations. This method provides new possibilities for detecting the dynamics of plasma-based accelerators and their optimization.

3.
Phys Rev Lett ; 126(1): 014801, 2021 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-33480753

RESUMO

Energy-efficient plasma-wakefield acceleration of particle bunches with low energy spread is a promising path to realizing compact free-electron lasers and particle colliders. High efficiency and low energy spread can be achieved simultaneously by strong beam loading of plasma wakefields when accelerating bunches with carefully tailored current profiles [M. Tzoufras et al., Phys. Rev. Lett. 101, 145002 (2008)PRLTAO0031-900710.1103/PhysRevLett.101.145002]. We experimentally demonstrate such optimal beam loading in a nonlinear electron-driven plasma accelerator. Bunches with an initial energy of 1 GeV were accelerated by 45 MeV with an energy-transfer efficiency of (42±4)% at a gradient of 1.3 GV/m while preserving per-mille energy spreads with full charge coupling, demonstrating wakefield flattening at the few-percent level.

4.
Phys Rev Lett ; 122(3): 034801, 2019 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-30735413

RESUMO

A tunable plasma-based energy dechirper has been developed at FLASHForward to remove the correlated energy spread of a 681 MeV electron bunch. Through the interaction of the bunch with wakefields excited in plasma the projected energy spread was reduced from a FWHM of 1.31% to 0.33% without reducing the stability of the incoming beam. The experimental results for variable plasma density are in good agreement with analytic predictions and three-dimensional simulations. The proof-of-principle dechirping strength of 1.8 GeV/mm/m significantly exceeds those demonstrated for competing state-of-the-art techniques and may be key to future plasma wakefield-based free-electron lasers and high energy physics facilities, where large intrinsic chirps need to be removed.

5.
Philos Trans A Math Phys Eng Sci ; 377(2151): 20180392, 2019 Aug 12.
Artigo em Inglês | MEDLINE | ID: mdl-31230573

RESUMO

The FLASHForward experimental facility is a high-performance test-bed for precision plasma wakefield research, aiming to accelerate high-quality electron beams to GeV-levels in a few centimetres of ionized gas. The plasma is created by ionizing gas in a gas cell either by a high-voltage discharge or a high-intensity laser pulse. The electrons to be accelerated will either be injected internally from the plasma background or externally from the FLASH superconducting RF front end. In both cases, the wakefield will be driven by electron beams provided by the FLASH gun and linac modules operating with a 10 Hz macro-pulse structure, generating 1.25 GeV, 1 nC electron bunches at up to 3 MHz micro-pulse repetition rates. At full capacity, this FLASH bunch-train structure corresponds to 30 kW of average power, orders of magnitude higher than drivers available to other state-of-the-art LWFA and PWFA experiments. This high-power functionality means FLASHForward is the only plasma wakefield facility in the world with the immediate capability to develop, explore and benchmark high-average-power plasma wakefield research essential for next-generation facilities. The operational parameters and technical highlights of the experiment are discussed, as well as the scientific goals and high-average-power outlook. This article is part of the Theo Murphy meeting issue 'Directions in particle beam-driven plasma wakefield acceleration'.

6.
Phys Rev Lett ; 119(18): 185002, 2017 Nov 03.
Artigo em Inglês | MEDLINE | ID: mdl-29219555

RESUMO

We report on the first experimental observation of a current-driven instability developing in a quasineutral matter-antimatter beam. Strong magnetic fields (≥1 T) are measured, via means of a proton radiography technique, after the propagation of a neutral electron-positron beam through a background electron-ion plasma. The experimentally determined equipartition parameter of ε_{B}≈10^{-3} is typical of values inferred from models of astrophysical gamma-ray bursts, in which the relativistic flows are also expected to be pair dominated. The data, supported by particle-in-cell simulations and simple analytical estimates, indicate that these magnetic fields persist in the background plasma for thousands of inverse plasma frequencies. The existence of such long-lived magnetic fields can be related to analog astrophysical systems, such as those prevalent in lepton-dominated jets.

7.
Phys Rev Lett ; 115(5): 055002, 2015 Jul 31.
Artigo em Inglês | MEDLINE | ID: mdl-26274425

RESUMO

We present few-femtosecond shadowgraphic snapshots taken during the nonlinear evolution of the plasma wave in a laser wakefield accelerator with transverse synchronized few-cycle probe pulses. These snapshots can be directly associated with the electron density distribution within the plasma wave and give quantitative information about its size and shape. Our results show that self-injection of electrons into the first plasma-wave period is induced by a lengthening of the first plasma period. Three-dimensional particle-in-cell simulations support our observations.

8.
Sci Rep ; 12(1): 16017, 2022 Sep 26.
Artigo em Inglês | MEDLINE | ID: mdl-36163419

RESUMO

Readily available bright X-ray beams with narrow bandwidth and tunable energy promise to unlock novel developments in a wide range of applications. Among emerging alternatives to large-scale and costly present-day radiation sources which severely restrict the availability of such beams, compact laser-plasma-accelerator-driven inverse Compton scattering sources show great potential. However, these sources are currently limited to tens of percent bandwidths, unacceptably large for many applications. Here, we show conceptually that using active plasma lenses to tailor the electron bunch-photon interaction, tunable X-ray and gamma beams with percent-level bandwidths can be produced. The central X-ray energy is tunable by varying the focusing strength of the lens, without changing electron bunch properties, allowing for precision-tuning the X-ray beam energy. This method is a key development towards laser-plasma-accelerator-driven narrowband, precision tunable femtosecond photon sources, enabling a paradigm shift and proliferation of compact X-ray applications.

9.
Rev Sci Instrum ; 92(1): 013505, 2021 Jan 01.
Artigo em Inglês | MEDLINE | ID: mdl-33514233

RESUMO

Precise characterization and tailoring of the spatial and temporal evolution of plasma density within plasma sources are critical for realizing high-quality accelerated beams in plasma wakefield accelerators. The simultaneous use of two independent diagnostics allowed the temporally and spatially resolved detection of plasma density with unprecedented sensitivity and enabled the characterization of the plasma temperature in discharge capillaries for times later than 0.5 µs after the initiation of the discharge, at which point the plasma is at local thermodynamic equilibrium. A common-path two-color laser interferometer for obtaining the average plasma density with a sensitivity of 2 × 1015 cm-2 was developed together with a plasma emission spectrometer for analyzing spectral line broadening profiles with a resolution of 5 × 1015 cm-3. Both diagnostics show good agreement when applying the spectral line broadening analysis methodology of Gigosos and Cardeñoso in the temperature range of 0.5 eV-5.0 eV. For plasma with densities of 0.5-2.5 × 1017 cm-3, temperatures of 1 eV-7 eV were indirectly measured by combining the diagnostic information. Measured longitudinally resolved plasma density profiles exhibit a clear temporal evolution from an initial flat-top to a Gaussian-like shape in the first microseconds as material is ejected out from the capillary. These measurements pave the way for highly detailed parameter tuning in plasma sources for particle accelerators and beam optics.

10.
Nat Commun ; 11(1): 6355, 2020 Dec 11.
Artigo em Inglês | MEDLINE | ID: mdl-33311487

RESUMO

Laser wakefield accelerators promise to revolutionize many areas of accelerator science. However, one of the greatest challenges to their widespread adoption is the difficulty in control and optimization of the accelerator outputs due to coupling between input parameters and the dynamic evolution of the accelerating structure. Here, we use machine learning techniques to automate a 100 MeV-scale accelerator, which optimized its outputs by simultaneously varying up to six parameters including the spectral and spatial phase of the laser and the plasma density and length. Most notably, the model built by the algorithm enabled optimization of the laser evolution that might otherwise have been missed in single-variable scans. Subtle tuning of the laser pulse shape caused an 80% increase in electron beam charge, despite the pulse length changing by just 1%.

11.
Sci Rep ; 8(1): 11010, 2018 Jul 20.
Artigo em Inglês | MEDLINE | ID: mdl-30030516

RESUMO

Betatron radiation from laser wakefield accelerators is an ultrashort pulsed source of hard, synchrotron-like x-ray radiation. It emanates from a centimetre scale plasma accelerator producing GeV level electron beams. In recent years betatron radiation has been developed as a unique source capable of producing high resolution x-ray images in compact geometries. However, until now, the short pulse nature of this radiation has not been exploited. This report details the first experiment to utilize betatron radiation to image a rapidly evolving phenomenon by using it to radiograph a laser driven shock wave in a silicon target. The spatial resolution of the image is comparable to what has been achieved in similar experiments at conventional synchrotron light sources. The intrinsic temporal resolution of betatron radiation is below 100 fs, indicating that significantly faster processes could be probed in future without compromising spatial resolution. Quantitative measurements of the shock velocity and material density were made from the radiographs recorded during shock compression and were consistent with the established shock response of silicon, as determined with traditional velocimetry approaches. This suggests that future compact betatron imaging beamlines could be useful in the imaging and diagnosis of high-energy-density physics experiments.

12.
Rev Sci Instrum ; 89(11): 113303, 2018 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-30501337

RESUMO

We present a design for a pixelated scintillator based gamma-ray spectrometer for non-linear inverse Compton scattering experiments. By colliding a laser wakefield accelerated electron beam with a tightly focused, intense laser pulse, gamma-ray photons up to 100 MeV energies and with few femtosecond duration may be produced. To measure the energy spectrum and angular distribution, a 33 × 47 array of cesium-iodide crystals was oriented such that the 47 crystal length axis was parallel to the gamma-ray beam and the 33 crystal length axis was oriented in the vertical direction. Using an iterative deconvolution method similar to the YOGI code, modeling of the scintillator response using GEANT4 and fitting to a quantum Monte Carlo calculated photon spectrum, we are able to extract the gamma ray spectra generated by the inverse Compton interaction.

13.
Sci Rep ; 5: 13244, 2015 Aug 18.
Artigo em Inglês | MEDLINE | ID: mdl-26283308

RESUMO

A bright µm-sized source of hard synchrotron x-rays (critical energy Ecrit > 30 keV) based on the betatron oscillations of laser wakefield accelerated electrons has been developed. The potential of this source for medical imaging was demonstrated by performing micro-computed tomography of a human femoral trabecular bone sample, allowing full 3D reconstruction to a resolution below 50 µm. The use of a 1 cm long wakefield accelerator means that the length of the beamline (excluding the laser) is dominated by the x-ray imaging distances rather than the electron acceleration distances. The source possesses high peak brightness, which allows each image to be recorded with a single exposure and reduces the time required for a full tomographic scan. These properties make this an interesting laboratory source for many tomographic imaging applications.


Assuntos
Fêmur/diagnóstico por imagem , Imageamento Tridimensional/instrumentação , Lasers , Aceleradores de Partículas/instrumentação , Tomografia Computadorizada por Raios X/instrumentação , Absorciometria de Fóton/instrumentação , Desenho de Equipamento , Análise de Falha de Equipamento , Humanos , Aumento da Imagem/instrumentação , Técnicas In Vitro , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
Nat Commun ; 6: 6747, 2015 Apr 23.
Artigo em Inglês | MEDLINE | ID: mdl-25903920

RESUMO

Electron-positron pair plasmas represent a unique state of matter, whereby there exists an intrinsic and complete symmetry between negatively charged (matter) and positively charged (antimatter) particles. These plasmas play a fundamental role in the dynamics of ultra-massive astrophysical objects and are believed to be associated with the emission of ultra-bright gamma-ray bursts. Despite extensive theoretical modelling, our knowledge of this state of matter is still speculative, owing to the extreme difficulty in recreating neutral matter-antimatter plasmas in the laboratory. Here we show that, by using a compact laser-driven setup, ion-free electron-positron plasmas with unique characteristics can be produced. Their charge neutrality (same amount of matter and antimatter), high-density and small divergence finally open up the possibility of studying electron-positron plasmas in controlled laboratory experiments.

16.
Mult Scler ; 15(3): 393-8, 2009 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-19028833

RESUMO

BACKGROUND: Little is known about social anxiety in MS. OBJECTIVE: We estimated the prevalence of social anxiety symptoms and their association with demographic and clinical features in a clinic-attending sample of patients with MS. METHODS: Patients attending the Dalhousie MS Research Unit for regularly scheduled visits completed the Social Phobia Inventory (SPIN), the Hospital Anxiety and Depression Scale (HADS), and the Health Utilities Index (HUI). Neurological disability was determined by ratings on the Expanded Disability Status Scale (EDSS). RESULTS: A total of 251 patients completed self-report scales of anxiety and depression symptoms. In all, 245 (98%) provided sufficient data for analysis. In all, 30.6% (n=75) had clinically significant social anxiety symptoms as defined by a SPIN threshold score of 19. Half of those with social anxiety had general anxiety (HADSA>or=11) and a quarter had depression (HADSD>or=11). Severity of social anxiety symptoms was associated with reduced health-related quality of life and not related to neurological disability. CONCLUSIONS: Social anxiety symptoms are common in persons with MS, contribute to overall morbidity, but are unrelated to the overall severity of neurologic disability. Greater awareness and routine systematic inquiry of social anxiety symptoms is an important component of comprehensive care for persons with MS.


Assuntos
Esclerose Múltipla Crônica Progressiva/epidemiologia , Esclerose Múltipla Crônica Progressiva/psicologia , Esclerose Múltipla Recidivante-Remitente/epidemiologia , Esclerose Múltipla Recidivante-Remitente/psicologia , Transtornos Fóbicos/epidemiologia , Adulto , Ansiedade/epidemiologia , Depressão/diagnóstico , Depressão/epidemiologia , Avaliação da Deficiência , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Prevalência , Qualidade de Vida , Inquéritos e Questionários
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA