Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Idioma
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Zhonghua Yi Xue Za Zhi ; 104(4): 262-268, 2024 Jan 23.
Artigo em Zh | MEDLINE | ID: mdl-38111276

RESUMO

Objective: To evaluate the feasibility and safety of transcatheter tricuspid valve edge-to-edge repair guided by only transesophageal echocardiography (TEE). Methods: Patients with severe tricuspid regurgitation in Fuwai Yunnan Cardiovascular Hospital who met the inclusion criteria based on clinical and echocardiographic evaluationand underwent transcatheter tricuspid valve edge-to-edge repair between January 2022 and May 2023 were prospectively enrolled. The procedure was performed under general anesthesia with endotracheal intubation and solely guided by TEE. The patients underwent clinical evaluation, electrocardiogram and transthoracic echocardiography one month after the procedure. Results: A total of 22 patients (12 males and 10 females) were included, with an average age of (71.3±6.7) years. All 22 patients successfully underwent the transcatheter tricuspid valve edge-to-edge repair under TEE guidance, with an average of (1.5±0.6) clips implanted. Immediately after procedure, six patients had no or trace regurgitation, 15 patients had mild regurgitation, and one patient had moderate regurgitation. All 22 patients completed 30-day follow-up, with four patients having trace regurgitation, 17 patients having mild regurgitation, and one patient having moderate regurgitation. Echocardiographic measurements revealed that effective regurgitant orifice area, regurgitant volume, vena contracta width, and proximal isovelocity surface area radius significantly decreased after the procedure (all P<0.05). In addition, inferior vena cava width, right atrial volume, tricuspid annular diameter, and right ventricular end-diastolic diameter significantly improved (all P<0.05), but tricuspid annular plane systolic excursion and right ventricular fractional area change did not show significant differences compared with those before the procedure (both P>0.05). Conclusion: It has been preliminarily confirmed that transcatheter tricuspid valve edge-to-edge repair solely guided by TEE is feasible and safe, but requires more large-scale studies for further validation.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Masculino , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Insuficiência da Valva Tricúspide/cirurgia , Ecocardiografia Transesofagiana/métodos , Resultado do Tratamento , Cateterismo Cardíaco/métodos , China , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Implante de Prótese de Valva Cardíaca/métodos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA