Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 176
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Lancet Oncol ; 25(7): 879-887, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38876123

RESUMO

BACKGROUND: Artificial intelligence (AI) systems can potentially aid the diagnostic pathway of prostate cancer by alleviating the increasing workload, preventing overdiagnosis, and reducing the dependence on experienced radiologists. We aimed to investigate the performance of AI systems at detecting clinically significant prostate cancer on MRI in comparison with radiologists using the Prostate Imaging-Reporting and Data System version 2.1 (PI-RADS 2.1) and the standard of care in multidisciplinary routine practice at scale. METHODS: In this international, paired, non-inferiority, confirmatory study, we trained and externally validated an AI system (developed within an international consortium) for detecting Gleason grade group 2 or greater cancers using a retrospective cohort of 10 207 MRI examinations from 9129 patients. Of these examinations, 9207 cases from three centres (11 sites) based in the Netherlands were used for training and tuning, and 1000 cases from four centres (12 sites) based in the Netherlands and Norway were used for testing. In parallel, we facilitated a multireader, multicase observer study with 62 radiologists (45 centres in 20 countries; median 7 [IQR 5-10] years of experience in reading prostate MRI) using PI-RADS (2.1) on 400 paired MRI examinations from the testing cohort. Primary endpoints were the sensitivity, specificity, and the area under the receiver operating characteristic curve (AUROC) of the AI system in comparison with that of all readers using PI-RADS (2.1) and in comparison with that of the historical radiology readings made during multidisciplinary routine practice (ie, the standard of care with the aid of patient history and peer consultation). Histopathology and at least 3 years (median 5 [IQR 4-6] years) of follow-up were used to establish the reference standard. The statistical analysis plan was prespecified with a primary hypothesis of non-inferiority (considering a margin of 0·05) and a secondary hypothesis of superiority towards the AI system, if non-inferiority was confirmed. This study was registered at ClinicalTrials.gov, NCT05489341. FINDINGS: Of the 10 207 examinations included from Jan 1, 2012, through Dec 31, 2021, 2440 cases had histologically confirmed Gleason grade group 2 or greater prostate cancer. In the subset of 400 testing cases in which the AI system was compared with the radiologists participating in the reader study, the AI system showed a statistically superior and non-inferior AUROC of 0·91 (95% CI 0·87-0·94; p<0·0001), in comparison to the pool of 62 radiologists with an AUROC of 0·86 (0·83-0·89), with a lower boundary of the two-sided 95% Wald CI for the difference in AUROC of 0·02. At the mean PI-RADS 3 or greater operating point of all readers, the AI system detected 6·8% more cases with Gleason grade group 2 or greater cancers at the same specificity (57·7%, 95% CI 51·6-63·3), or 50·4% fewer false-positive results and 20·0% fewer cases with Gleason grade group 1 cancers at the same sensitivity (89·4%, 95% CI 85·3-92·9). In all 1000 testing cases where the AI system was compared with the radiology readings made during multidisciplinary practice, non-inferiority was not confirmed, as the AI system showed lower specificity (68·9% [95% CI 65·3-72·4] vs 69·0% [65·5-72·5]) at the same sensitivity (96·1%, 94·0-98·2) as the PI-RADS 3 or greater operating point. The lower boundary of the two-sided 95% Wald CI for the difference in specificity (-0·04) was greater than the non-inferiority margin (-0·05) and a p value below the significance threshold was reached (p<0·001). INTERPRETATION: An AI system was superior to radiologists using PI-RADS (2.1), on average, at detecting clinically significant prostate cancer and comparable to the standard of care. Such a system shows the potential to be a supportive tool within a primary diagnostic setting, with several associated benefits for patients and radiologists. Prospective validation is needed to test clinical applicability of this system. FUNDING: Health~Holland and EU Horizon 2020.


Assuntos
Inteligência Artificial , Imageamento por Ressonância Magnética , Neoplasias da Próstata , Radiologistas , Humanos , Masculino , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Idoso , Estudos Retrospectivos , Pessoa de Meia-Idade , Gradação de Tumores , Países Baixos , Curva ROC
2.
Eur Radiol ; 34(1): 204-213, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37561183

RESUMO

OBJECTIVES: The main objective is to propose an MRI-based screening protocol, investigating the role of MRI without the injection of contrast media (bi-parametric MRI, bpMRI) as a secondary prevention test for prostate cancer (PCa) early diagnosis, comparing MRI with the prostate specific antigen (PSA) test. For this reason, preliminary results of Prostate Cancer Secondary Screening in Sapienza (PROSA) are presented, to investigate the efficiency of an MRI-based screening protocol. PROSA is a prospective, randomized, single-center study. To date, 351 men have been enrolled and blindly randomized into two different arms: (A) Men underwent a bpMRI regardless of their PSA values (175); (B) Men followed as per clinical practice: those with increased PSA (61) were referred to bpMRI, while those with normal PSA (112) were not. Men who screened positive on MRI were directed to MR-directed targeted biopsy. On arm A, 4 clinically significant PCa have been detected, while none was found on arm B (p = 0.046). To evaluate the efficiency of the screening protocol, we calculated the experimental event rate (EER, 3.6%), control event rate (CER, 1.2%.), absolute risk reduction (ARR, 2.5%), and number needed to treat (NNT, 40.3). PROSA represents an interesting experience in the field of imaging-based PCa screening. The preliminary data from this trial highlight the promising role of non-contrast MRI as a screening tool for early detection of PCa. Further data will finally validate the most appropriate screening program. CLINICAL RELEVANCE STATEMENT: PROSA depicts an interesting experience in the field of research focused on imaging-based prostate cancer screening. Its preliminary data highlight the promising role of non-contrast MRI as a screening tool for early detection of PCa. KEY POINTS: • Promotion of an MRI-based screening protocol, investigating the role of non-contrast MRI as a secondary prevention test for prostate cancer early diagnosis, comparing MRI with PSA test. • Prostate Cancer Secondary Screening in Sapienza (PROSA) represents an interesting experience in the field of research focused on imaging-based prostate cancer screening; its preliminary results indicate that it is possible to use non-contrast MRI as a screening tool for early detection of PCa. • This new approach to PCa screening could facilitate the early diagnosis of clinically significant prostate cancer while reducing the number of unnecessary prostate biopsies and the detection of clinically insignificant prostate cancer.


Assuntos
Neoplasias da Próstata , Masculino , Humanos , Neoplasias da Próstata/patologia , Antígeno Prostático Específico , Detecção Precoce de Câncer , Estudos Prospectivos , Biópsia Guiada por Imagem/métodos , Imageamento por Ressonância Magnética/métodos
3.
Eur Radiol ; 2024 May 23.
Artigo em Inglês | MEDLINE | ID: mdl-38780764

RESUMO

MRI has gained prominence in the diagnostic workup of prostate cancer (PCa) patients, with the Prostate Imaging Reporting and Data System (PI-RADS) being widely used for cancer detection. Beyond PI-RADS, other MRI-based scoring tools have emerged to address broader aspects within the PCa domain. However, the multitude of available MRI-based grading systems has led to inconsistencies in their application within clinical workflows. The Prostate Cancer Radiological Estimation of Change in Sequential Evaluation (PRECISE) assesses the likelihood of clinically significant radiological changes of PCa during active surveillance, and the Prostate Imaging for Local Recurrence Reporting (PI-RR) scoring system evaluates the risk of local recurrence after whole-gland therapies with curative intent. Underlying any system is the requirement to assess image quality using the Prostate Imaging Quality Scoring System (PI-QUAL). This article offers practicing radiologists a comprehensive overview of currently available scoring systems with clinical evidence supporting their use for managing PCa patients to enhance consistency in interpretation and facilitate effective communication with referring clinicians. KEY POINTS: Assessing image quality is essential for all prostate MRI interpretations and the PI-QUAL score represents  the standardized tool for this purpose. Current urological clinical guidelines for prostate cancer diagnosis and localization recommend adhering to the PI-RADS recommendations. The PRECISE and PI-RR scoring systems can be used for assessing radiological changes of prostate cancer during active surveillance and the likelihood of local recurrence after radical treatments respectively.

4.
Eur Radiol ; 2024 May 24.
Artigo em Inglês | MEDLINE | ID: mdl-38787428

RESUMO

Multiparametric MRI is the optimal primary investigation when prostate cancer is suspected, and its ability to rule in and rule out clinically significant disease relies on high-quality anatomical and functional images. Avenues for achieving consistent high-quality acquisitions include meticulous patient preparation, scanner setup, optimised pulse sequences, personnel training, and artificial intelligence systems. The impact of these interventions on the final images needs to be quantified. The prostate imaging quality (PI-QUAL) scoring system was the first standardised quantification method that demonstrated the potential for clinical benefit by relating image quality to cancer detection ability by MRI. We present the updated version of PI-QUAL (PI-QUAL v2) which applies to prostate MRI performed with or without intravenous contrast medium using a simplified 3-point scale focused on critical technical and qualitative image parameters. CLINICAL RELEVANCE STATEMENT: High image quality is crucial for prostate MRI, and the updated version of the PI-QUAL score (PI-QUAL v2) aims to address the limitations of version 1. It is now applicable to both multiparametric MRI and MRI without intravenous contrast medium. KEY POINTS: High-quality images are essential for prostate cancer diagnosis and management using MRI. PI-QUAL v2 simplifies image assessment and expands its applicability to prostate MRI without contrast medium. PI-QUAL v2 focuses on critical technical and qualitative image parameters and emphasises T2-WI and DWI.

5.
AJR Am J Roentgenol ; 2024 Apr 03.
Artigo em Inglês | MEDLINE | ID: mdl-38568038

RESUMO

Multiparametric MRI (mpMRI), interpreted using PI-RADS, improves the initial detection of clinically significant prostate cancer (PCa). Prostate MR image quality has increasingly recognized relevance to the use of mpMRI for PCa diagnosis. Additionally, mpMRI is increasingly used in scenarios beyond initial detection, including active surveillance and assessment for local recurrence after prostatectomy, radiation therapy, or focal therapy. Acknowledging these evolving demands, specialized prostate MRI scoring systems beyond PI-RADS have emerged, to address distinct scenarios and unmet needs. Examples include Prostate Imaging Quality (PI-QUAL) for assessment of image quality of mpMRI, Prostate Cancer Radiologic Estimation of Change in Sequential Evaluation (PRECISE) recommendations for evaluation of serial mpMRI examinations during active surveillance, Prostate Imaging for Recurrence Reporting System (PI-RR) for assessment for local recurrence after prostatectomy or radiation therapy, and Prostate Imaging after Focal Ablation (PI-FAB) for assessment for local recurrence after focal therapy. These systems' development and early uptake signal a compelling shift towards prostate MRI standardization in different scenarios, and ongoing research will help refine their roles in practice. This AJR Expert Panel Narrative Review critically examines these new prostate MRI scoring systems (PI-QUAL, PRECISE, PI-RR, and PI-FAB), analyzing the available evidence, delineating current limitations, and proposing solutions for improvement.

6.
Radiol Med ; 2024 Jun 25.
Artigo em Inglês | MEDLINE | ID: mdl-38918291

RESUMO

BACKGROUND: Radical prostatectomy (RP) is recommended in case of localized or locally advanced prostate cancer (PCa), but it can lead to side effects, including urinary incontinence (UI) and erectile dysfunction (ED). Magnetic resonance imaging (MRI) is recommended for PCa diagnosis and staging, but it can also improve preoperative risk-stratification. PURPOSE: This nonsystematic review aims to provide an overview on factors involved in RP side effects, highlighting anatomical and pathological aspects that could be included in a structured report. EVIDENCE SYNTHESIS: Considering UI evaluation, MR can investigate membranous urethra length (MUL), prostate volume, the urethral sphincter complex, and the presence of prostate median lobe. Longer MUL measurement based on MRI is linked to a higher likelihood of achieving continence restoration. For ED assessment, MRI and diffusion tensor imaging identify the neurovascular bundle and they can aid in surgery planning. Finally, MRI can precisely describe extra-prostatic extension, prostate apex characteristics and lymph-node involvement, providing valuable preoperative information for PCa treatment. CONCLUSIONS: Anatomical principals structures involved in RP side effects can be assessed with MR. A standardized MR report detailing these structures could assist urologists in planning optimal and tailored surgical techniques, reducing complications, and improving patients' care.

7.
Radiol Med ; 2024 May 10.
Artigo em Inglês | MEDLINE | ID: mdl-38730037

RESUMO

PURPOSE: To evaluate the diagnostic accuracy of the Node-RADS score and the utility of apparent diffusion coefficient (ADC) values in predicting metastatic lymph nodes (LNs) involvement in cervical cancer (CC) patients using magnetic resonance imaging (MRI). The applicability of the Node RADS score across three readers with different years of experience in pelvic imaging was also assessed. MATERIAL AND METHODS: Among 140 patients, 68 underwent staging MRI, neoadjuvant chemotherapy and radical surgery, forming the study cohort. Node-RADS scores of the main pelvic stations were retrospectively determined to assess LN metastatic likelihood and compared with the histological findings. Mean ADC, relative ADC (rADC), and correct ADC (cADC) values of LNs classified as Node-RADS ≥ 3 were measured and compared with histological reports, considered as gold standard. RESULTS: Sensitivity, specificity, positive and negative predictive values (PPVs and NPVs), and accuracy were calculated for different Node-RADS thresholds. Node RADS ≥ 3 showed a sensitivity of 92.8% and specificity of 72.5%. Node RADS ≥ 4 yielded a sensitivity of 71.4% and specificity of 100%, while Node RADS 5 yielded 42.9% and 100%, respectively. The diagnostic performance of mean ADC, cADC and rADC values from 78 LNs with Node-RADS score ≥ 3 was assessed, with ADC demonstrating the highest area under the curve (AUC 0.820), compared to cADC and rADC values. CONCLUSION: The Node-RADS score provides a standardized LNs assessment, enhancing diagnostic accuracy in CC patients. Its ease of use and high inter-observer concordance support its clinical utility. ADC measurement of LNs shows promise as an additional tool for optimizing patient diagnostic evaluation.

8.
J Clin Immunol ; 43(8): 1903-1915, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37548814

RESUMO

PURPOSE: To investigate computed tomography (CT) findings of Granulomatous Lymphocytic Interstitial Lung Disease (GL-ILD) in Common Variable Immunodeficiency (CVID), also in comparison with non-GL-ILD abnormalities, correlating GL-ILD features with functional/immunological parameters and looking for GL-ILD therapy predictive elements. METHODS: CT features of 38 GL-ILD and 38 matched non-GL-ILD subjects were retrospectively described. Correlations of GL-ILD features with functional/immunological features were assessed. A logistic regression was performed to find a predictive model of GL-ILD therapeutic decisions. RESULTS: Most common GL-ILD CT findings were bronchiectasis, non-perilymphatic nodules, consolidations, Ground Glass Opacities (GGO), bands and enlarged lymphnodes. GL-ILD was usually predominant in lower fields. Multiple small nodules (≤10 mm), consolidations, reticulations and fibrotic ILD are more indicative of GL-ILD. Bronchiectasis, GGO, Reticulations and fibrotic ILD correlated with decreased lung performance. Bronchiectasis, GGO and fibrotic ILD were associated with low IgA levels, whereas high CD4+ T cells percentage was related to GGO. Twenty out of 38 patients underwent GL-ILD therapy. A model combining Marginal Zone (MZ) B cells percentage, IgA levels, lower field consolidations and lymphnodes enlargement showed a good discriminatory capacity with regards to GL-ILD treatment. CONCLUSIONS: GL-ILD is a lower field predominant disease, commonly characterized by bronchiectasis, non-perilymphatic small nodules, consolidations, GGO and bands. Multiple small nodules, consolidations, reticulations and fibrotic ILD may suggest the presence of GL-ILD in CVID. MZ B cells percentage, IgA levels at diagnosis, lower field consolidations and mediastinal lymphnodes enlargement may predict the need of a specific GL-ILD therapy.


Assuntos
Bronquiectasia , Imunodeficiência de Variável Comum , Doenças Pulmonares Intersticiais , Humanos , Diagnóstico Diferencial , Imunodeficiência de Variável Comum/complicações , Imunodeficiência de Variável Comum/diagnóstico , Imunodeficiência de Variável Comum/tratamento farmacológico , Estudos Retrospectivos , Bronquiectasia/diagnóstico , Tomografia Computadorizada por Raios X , Doenças Pulmonares Intersticiais/diagnóstico , Doenças Pulmonares Intersticiais/tratamento farmacológico , Doenças Pulmonares Intersticiais/etiologia , Imunoglobulina A
9.
Artigo em Inglês | MEDLINE | ID: mdl-37399086

RESUMO

Lung ultrasound (LUS) is a promising tool for detecting systemic sclerosis-associated interstitial lung disease (SSc-ILD). Currently, consensus on the best LUS findings and execution technique is lacking. OBJECTIVES: To compare qualitative and quantitative assessment of B-lines and pleural line (PL) alterations in SSc-ILD with chest computed tomography (CT) analysis. METHODS: During 2021-2022, consecutive SSc patients according to 2013 ACR/EULAR classification criteria underwent pulmonary functional tests (PFTs). On the same day, if a CT was performed over a ± 6 months period, LUS was performed by two certified blinded operators using a 14-scans method. The ≥10 B-lines cut-off proposed by Tardella and the Fairchild's PL criteria fulfilment were selected as qualitative findings. As quantitative assessment, total B-lines number and the quantitative PL score adapted from the semi-quantitative Pinal-Fernandez score were collected. CT scans were evaluated by two thoracic radiologists for ILD presence, with further processing by automated texture analysis software (qCT). RESULTS: 29 SSc patients were enrolled. Both qualitative LUS scores were significantly associated to ILD presence on CT, with Fairchild's PL criteria resulting in slightly more accuracy. Results were confirmed on multivariate analysis. All qualitative and quantitative LUS findings were found to be significantly associated with qCT ILD extension and radiological abnormalities. Mid and basal PL quantitative score correlated with mid and basal qCT ILD extents. Both B-lines and PL alterations differently correlated with PFTs and clinical variables. CONCLUSION: This preliminary study suggests the utility of a comprehensive LUS assessment for SSc-ILD detection compared with CT and qCT.

10.
Eur Radiol ; 33(8): 5828-5839, 2023 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-37045981

RESUMO

OBJECTIVES: To evaluate MRI diagnostic performance in detecting clinically significant prostate cancer (csPCa) in peripheral-zone PI-RADS 4 lesions, comparing those with clearly restricted diffusion (DWI-score 4), and those with equivocal diffusion pattern (DWI-score 3) and positive dynamic contrast-enhanced (DCE) MRI. METHODS: This observational prospective study enrolled 389 men referred to MRI and, if positive (PI-RADS 3 with PSA-density [PSAD] ≥ 0.15 ng/mL/mL, 4 and 5), to MRI-directed biopsy. Lesions with DWI-score 3 and positive DCE were classified as "PI-RADS 3up," instead of PI-RADS 4. Univariable and multivariable analyses were implemented to determine features correlated to csPCa detection. RESULTS: Prevalence of csPCa was 14.5% and 53.3% in PI-RADS categories 3up and 4, respectively (p < 0.001). MRI showed a sensitivity of 100.0%, specificity 40.9%, PPV 46.5%, NPV 100.0%, and accuracy 60.9% for csPCa detection. Modifying the threshold to consider MRI positive and to indicate biopsy (same as previously described, but PI-RADS 3up only when associated with elevated PSAD), the sensitivity changed to 93.9%, specificity 57.2%, PPV 53.0%, NPV 94.8%, and accuracy 69.7%. Age (p < 0.001), PSAD (p < 0.001), positive DWI (p < 0.001), and PI-RADS score (p = 0.04) resulted in independent predictors of csPCa. CONCLUSIONS: Most cases of PI-RADS 3up were false-positives, suggesting that upgrading peripheral lesions with DWI-score 3 to PI-RADS 4 because of positive DCE has a detrimental effect on MRI accuracy, decreasing the true prevalence of csPCa in the PI-RADS 4 category. PI-RADS 3up should not be upgraded and directed to biopsy only if associated with increased PSAD. KEY POINTS: • As per PI-RADS v2.1 recommendations, in case of a peripheral zone lesion with equivocal diffusion-weighted imaging (DWI score 3), but positive dynamic contrast-enhanced (DCE) MRI, the overall PI-RADS score should be upgraded to 4. • The current PI-RADS recommendation of upgrading PI-RADS 3 lesions of the peripheral zone to PI-RADS 4 because of positive DCE decreased clinically significant prostate cancer detection rate in our series. • According to our results, the most accurate threshold for setting indication to prostate biopsy is PI-RADS 3 or PI-RADS 3 with positive DCE both associated with increased PSA density.


Assuntos
Imageamento por Ressonância Magnética , Neoplasias da Próstata , Masculino , Humanos , Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/patologia , Antígeno Prostático Específico , Estudos Prospectivos , Estudos Retrospectivos , Meios de Contraste/farmacologia , Biópsia Guiada por Imagem/métodos
11.
Respiration ; 102(4): 287-295, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36806049

RESUMO

BACKGROUND: Post-COVID-19 Interstitial Lung Disease (PC-ILD) is characterized by fibrotic-like signs at high-resolution computed tomography (HRCT) and pulmonary function tests (PFTs) abnormalities after SARS-CoV-2 infection. It is still not clear how frequent these tests should be performed to rule out long-term consequences of COVID-19 pneumonia. OBJECTIVES: The aims of our study were to evaluate the incidence and risk factors of PC-ILD and possibly to propose a long-term follow-up program. METHOD: One-hundred patients, hospitalized in our ward for moderate to critical COVID-19, underwent two follow-up visits at three and 15 months in which PFTs and HRCT were performed. RESULTS: At the 15-month follow-up, 8% of patients showed residual radiological and functional signs consistent with PC-ILD. All but one of these patients had already demonstrated PFTs and HRCT alterations at first follow-up visit, and the last 1 patient showed worsening of lung function during follow-up. These findings highlight the negative predictive value of PFTs at 3-month follow-up for the development of PC-ILD. Aging, severity of COVID-19, and degree of pulmonary involvement during acute infection proved to be significant risk factors for developing PC-ILD. CONCLUSIONS: Our study highlights the importance of PFTs in the long-term follow-up of patients affected by moderate to critical COVID-19 pneumonia. Further studies are needed to confirm our hypothesis that HRCT should be performed only in patients with PFTs abnormalities.


Assuntos
COVID-19 , Doenças Pulmonares Intersticiais , Humanos , Seguimentos , COVID-19/complicações , SARS-CoV-2 , Doenças Pulmonares Intersticiais/diagnóstico , Pulmão , Tomografia Computadorizada por Raios X , Testes de Função Respiratória
12.
Radiology ; 304(2): 342-350, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35536130

RESUMO

Background Prostate cancer local recurrence location and extent must be determined in an accurate and timely manner. Because of the lack of a standardized MRI approach after whole-gland treatment, a panel of international experts recently proposed the Prostate Imaging for Recurrence Reporting (PI-RR) assessment score. Purpose To determine the diagnostic accuracy of PI-RR for detecting local recurrence in patients with biochemical recurrence (BCR) after radiation therapy (RT) or radical prostatectomy (RP) and to evaluate the interreader variability of PI-RR scoring. Materials and Methods This retrospective observational study included patients who underwent multiparametric MRI between September 2016 and May 2021 for BCR after RT or RP. MRI scans were analyzed, and a PI-RR score was assigned independently by four radiologists. The reference standard was defined using histopathologic findings, follow-up imaging, or clinical response to treatment. Sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy were calculated to assess PI-RR performance for each reader. The intraclass correlation coefficient was used to determine interreader agreement. Results A total of 100 men were included: 48 patients after RT (median age, 76 years [IQR, 70-82 years]) and 52 patients after RP (median age, 70 years [IQR, 66-74 years]). After RT, with PI-RR of 3 or greater as a cutoff (assigned when recurrence is uncertain), diagnostic performance ranges were 71%-81% sensitivity, 74%-93% specificity, 71%-89% PPV, 79%-86% NPV, and 77%-88% accuracy across the four readers. After RP, with PI-RR of 3 or greater as a cutoff, performance ranges were 59%-83% sensitivity, 87%-100% specificity, 88%-100% PPV, 66%-80% NPV, and 75%-85% accuracy. The intraclass correlation coefficient was 0.87 across the four readers for both the RT and RP groups. Conclusion MRI scoring with the Prostate Imaging for Recurrence Reporting assessment provides structured, reproducible, and accurate evaluation of local recurrence after definitive therapy for prostate cancer. © RSNA, 2022 Online supplemental material is available for this article. See also the editorial by Haider in this issue. An earlier incorrect version appeared online. This article was corrected on May 11, 2022.


Assuntos
Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias da Próstata , Idoso , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Recidiva Local de Neoplasia/patologia , Próstata/patologia , Prostatectomia , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/patologia , Neoplasias da Próstata/cirurgia , Estudos Retrospectivos
13.
J Magn Reson Imaging ; 55(1): 23-36, 2022 01.
Artigo em Inglês | MEDLINE | ID: mdl-32939939

RESUMO

Bladder cancer (BCa) is among the ten most frequent cancers globally. It is the tumor with the highest lifetime treatment-associated costs, and among the tumors with the heaviest impacts on postoperative quality of life. The purpose of this article is to review the current applications and future perspectives of the Vesical Imaging Reporting and Data System (VI-RADS). VI-RADS is a newly developed scoring system aimed at standardization of MRI acquisition, interpretation, and reporting for BCa. An insight will be given on the BCa natural history, current MRI applications for local BCa staging with assessment of muscle invasiveness, and clinical implications of the score for disease management. Future applications include risk stratification of nonmuscle invasive BCa, surveillance, and prediction and monitoring of therapy response. LEVEL OF EVIDENCE: 3 TECHNICAL EFFICACY STAGE: 2.


Assuntos
Neoplasias da Bexiga Urinária , Humanos , Qualidade de Vida , Projetos de Pesquisa , Neoplasias da Bexiga Urinária/diagnóstico por imagem
14.
J Magn Reson Imaging ; 55(2): 480-490, 2022 02.
Artigo em Inglês | MEDLINE | ID: mdl-34374181

RESUMO

BACKGROUND: Prostate magnetic resonance imaging (MRI) is technically demanding, requiring high image quality to reach its full diagnostic potential. An automated method to identify diagnostically inadequate images could help optimize image quality. PURPOSE: To develop a convolutional neural networks (CNNs) based analysis pipeline for the classification of prostate MRI image quality. STUDY TYPE: Retrospective. SUBJECTS: Three hundred sixteen prostate mpMRI scans and 312 men (median age 67). FIELD STRENGTH/SEQUENCE: A 3 T; fast spin echo T2WI, echo planar imaging DWI, ADC, gradient-echo dynamic contrast enhanced (DCE). ASSESSMENT: MRI scans were reviewed by three genitourinary radiologists (V.P., M.D.M., S.C.) with 21, 12, and 5 years of experience, respectively. Sequences were labeled as high quality (Q1) or low quality (Q0) and used as the reference standard for all analyses. STATISTICAL TESTS: Sequences were split into training, validation, and testing sets (869, 250, and 120 sequences, respectively). Inter-reader agreement was assessed with the Fleiss kappa. Following preprocessing and data augmentation, 28 CNNs were trained on MRI slices for each sequence. Model performance was assessed on both a per-slice and a per-sequence basis. A pairwise t-test was performed to compare performances of the classifiers. RESULTS: The number of sequences labeled as Q0 or Q1 was 38 vs. 278 for T2WI, 43 vs. 273 for DWI, 41 vs. 275 for ADC, and 38 vs. 253 for DCE. Inter-reader agreement was almost perfect for T2WI and DCE and substantial for DWI and ADC. On the per-slice analysis, accuracy was 89.95% ± 0.02% for T2WI, 79.83% ± 0.04% for DWI, 76.64% ± 0.04% for ADC, 96.62% ± 0.01% for DCE. On the per-sequence analysis, accuracy was 100% ± 0.00% for T2WI, DWI, and DCE, and 92.31% ± 0.00% for ADC. The three best algorithms performed significantly better than the remaining ones on every sequence (P-value < 0.05). DATA CONCLUSION: CNNs achieved high accuracy in classifying prostate MRI image quality on an individual-slice basis and almost perfect accuracy when classifying the entire sequences. EVIDENCE LEVEL: 4 TECHNICAL EFFICACY: Stage 1.


Assuntos
Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias da Próstata , Idoso , Imagem de Difusão por Ressonância Magnética , Humanos , Imageamento por Ressonância Magnética , Masculino , Redes Neurais de Computação , Próstata/diagnóstico por imagem , Neoplasias da Próstata/diagnóstico por imagem , Estudos Retrospectivos
15.
World J Urol ; 40(7): 1617-1628, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35294583

RESUMO

PURPOSE: To determine through a comprehensive systematic review and meta-analysis the cumulative diagnostic performance of vesical imaging-reporting and data system (VIRADS) to predict preoperative muscle-invasiveness among different institutions, readers, and optimal scoring accuracy thresholds. METHODS: PubMed, Cochrane and Embase were searched from inception up to May 2021. Sensitivity (Sn), Specificity (Sp) were first estimated and subsequently pooled using hierarchical summary receiver operating characteristics (HSROC) modeling for both cut-off ≥ 3 and ≥ 4 to predict muscle-invasive bladder cancer (MIBC). Further sensitivity analysis, subgroup analysis and meta-regression were conducted to investigate contribution of moderators to heterogeneity. RESULTS: In total, n = 20 studies from 2019 to 2021 with n = 2477 patients by n = 53 genitourinary radiologists met the inclusion criteria. Pooled weighted Sn and Sp were 0.87 (95% CI 0.82-0.91) and 0.86 (95% CI 0.80-0.90) for cut-off ≥ 3 while 0.78 (95% CI 0.74-0.81) and 0.94 (95% CI 0.91-0.96) for cut-off ≥ 4. The area under the HSROC curve was 0.93 (95% CI 0.90-0.95) and 0.91 (95% CI 0.88-0.93) for cut-off ≥ 3 and ≥ 4, respectively. Meta-regression analyses showed no influence of clinical characteristics nor cumulative reader's experience while study design and radiological characteristics were found to influence the estimated outcome. CONCLUSION: We demonstrated excellent worldwide diagnostic performance of VI-RADS to determine pre-trans urethral resection of bladder tumor (TURBT) staging. Our findings corroborate wide reliability of VI-RADS accuracy also between different centers with varying experience underling the importance that standardization and reproducibility of VI-RADS may confer to multiparametric magnetic resonance imaging (mpMRI) for preoperative BCa discrimination.


Assuntos
Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias da Bexiga Urinária , Sistemas de Dados , Humanos , Imageamento por Ressonância Magnética/métodos , Reprodutibilidade dos Testes , Bexiga Urinária/diagnóstico por imagem , Bexiga Urinária/patologia , Neoplasias da Bexiga Urinária/diagnóstico por imagem , Neoplasias da Bexiga Urinária/cirurgia
16.
Eur Radiol ; 32(11): 7494-7503, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-35366122

RESUMO

OBJECTIVE: The purpose of the study was to evaluate the effect of an interactive training program on the learning curve of radiology residents for bladder MRI interpretation using the VI-RADS score. METHODS: Three radiology residents with minimal experience in bladder MRI served as readers. They blindly evaluated 200 studies divided into 4 subsets of 50 cases over a 3-month period. After 2 months, the first subset was reassessed, resulting in a total of 250 evaluations. An interactive training program was provided and included educational lessons and case-based practice. The learning curve was constructed by plotting mean agreement as the ratio of correct evaluations per batch. Inter-reader agreement and diagnostic performance analysis were performed with kappa statistics and ROC analysis. RESULTS: As for the VI-RADS scoring agreement, the kappa differences between pre-training and post-training evaluation of the same group of cases were 0.555 to 0.852 for reader 1, 0.522 to 0.695 for reader 2, and 0.481 to 0.794 for reader 3. Using VI-RADS ≥ 3 as cut-off for muscle invasion, sensitivity ranged from 84 to 89% and specificity from 91 to 94%, while the AUCs from 0.89 (95% CI:0.84, 0.94) to 0.90 (95% CI:0.86, 0.95). Mean evaluation time decreased from 5.21 ± 1.12 to 3.52 ± 0.69 min in subsets 1 and 5. Mean grade of confidence improved from 3.31 ± 0.93 to 4.21 ± 0.69, in subsets 1 and 5. CONCLUSION: An interactive dedicated education program on bladder MRI and the VI-RADS score led to a significant increase in readers' diagnostic performance over time, with a general improvement observed after 100-150 cases. KEY POINTS: • After the first educational lesson and 100 cases were interpreted, the concordance on VI-RADS scoring between the residents and the experienced radiologist was significantly higher. • An increase in the grade of confidence was experienced after 100 cases. • We found a decrease in the evaluation time after 150 cases.


Assuntos
Neoplasias da Bexiga Urinária , Bexiga Urinária , Humanos , Bexiga Urinária/diagnóstico por imagem , Curva de Aprendizado , Imageamento por Ressonância Magnética/métodos , Curva ROC , Área Sob a Curva , Neoplasias da Bexiga Urinária/diagnóstico por imagem , Estudos Retrospectivos
17.
Curr Opin Urol ; 32(5): 536-544, 2022 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-35849696

RESUMO

PURPOSE OF REVIEW: To conduct a nonsystematic review of the existing literature to investigate the role of Magnetic Resonance Imaging (MRI) in urothelial carcinomas (UCs). RECENT FINDINGS: Imaging is becoming progressively more crucial in local and distant staging of UCs, especially in cases of bladder cancer (BCa). The primary objective of imaging in patients with BCa is to detect lesions and distinguish T1 from T2 stages, since the treatment varies significantly. SUMMARY: The applicability of MRI in the management of UCs has been investigated, particularly focusing on the new evidence on multiparametric MRI (mpMRI) of the bladder and Vesical Imaging-Reporting And Data System score for the description of BCa and discussing the possible utility of MRI for upper tract urothelial carcinomas . Imaging modalities, in particular CT and MRI, are essential tools for the local and distant staging of UCs. MpMRI of the bladder and VI-RADS score accurately define the risk of muscle invasiveness, promoting tailored therapeutic planning. Moreover, mpMRI has also been included in patients' follow-up and in the assessment of response to systematic therapy. MRI utility and possible application in upper tract urothelial carcinomas cases are yet to be discovered.


Assuntos
Carcinoma de Células de Transição , Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias da Bexiga Urinária , Carcinoma de Células de Transição/diagnóstico por imagem , Sistemas de Dados , Humanos , Imageamento por Ressonância Magnética/métodos , Neoplasias da Bexiga Urinária/diagnóstico por imagem , Neoplasias da Bexiga Urinária/patologia , Neoplasias da Bexiga Urinária/terapia
18.
Radiol Med ; 127(11): 1245-1253, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36114928

RESUMO

OBJECTIVE: To investigate the impact of an artificial intelligence (AI) software and quantitative ADC (qADC) on the inter-reader agreement, diagnostic performance, and reporting times of prostate biparametric MRI (bpMRI) for experienced and inexperienced readers. MATERIALS AND METHODS: A total of 170 multiparametric MRI (mpMRI) of patients with suspicion of prostate cancer (PCa) were retrospectively reviewed by one experienced and one inexperienced reader three times, following a wash-out period. First, only the bpMRI sequences, including T2-weighted imaging (T2WI), diffusion-weighted imaging (DWI) sequences, and apparent diffusion coefficient (ADC) maps, were used. Then, bpMRI and quantitative ADC values were used. Lastly, bpMRI and the AI software were used. Inter-reader agreement between the two readers and between each reader and the mpMRI original reports was calculated. Detection rates and reporting times were calculated for each group. RESULTS: Inter-reader agreement with respect to mpMRI was moderate for bpMRI, Quantib, and qADC for both the inexperienced (weighted k of 0.42, 0.45, and 0.41, respectively) and the experienced radiologists (weighted k of 0.44, 0.46, and 0.42, respectively). Detection rate of PCa was similar between the inexperienced (0.24, 0.26, and 0.23) and the experienced reader (0.26, 0.27 and 0.27), for bpMRI, Quantib, and qADC, respectively. Reporting times were lower for Quantib (8.23, 7.11, and 9.87 min for the inexperienced reader and 5.62, 5.07, and 6.21 min for the experienced reader, for bpMRI, Quantib, and qADC, respectively). CONCLUSIONS: AI and qADC did not have a significant impact on the diagnostic performance of both readers. The use of Quantib was associated with lower reporting times.


Assuntos
Aprendizado Profundo , Neoplasias da Próstata , Masculino , Humanos , Próstata/diagnóstico por imagem , Estudos Retrospectivos , Inteligência Artificial , Imageamento por Ressonância Magnética/métodos , Neoplasias da Próstata/diagnóstico por imagem , Software
19.
Radiol Med ; 127(8): 881-890, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35763251

RESUMO

PURPOSE: To determine the clinical, pathological, and radiological features, including the Vesical Imaging-Reporting and Data System (VI-RADS) score, independently correlating with muscle-invasive bladder cancer (BCa), in a multicentric national setting. METHOD AND MATERIALS: Patients with BCa suspicion were offered magnetic resonance imaging (MRI) before trans-urethral resection of bladder tumor (TURBT). According to VI-RADS, a cutoff of ≥ 3 or ≥ 4 was assumed to define muscle-invasive bladder cancer (MIBC). Trans-urethral resection of the tumor (TURBT) and/or cystectomy reports were compared with preoperative VI-RADS scores to assess accuracy of MRI for discriminating between non-muscle-invasive versus MIBC. Performance was assessed by ROC curve analysis. Two univariable and multivariable logistic regression models were implemented including clinical, pathological, radiological data, and VI-RADS categories to determine the variables with an independent effect on MIBC. RESULTS: A final cohort of 139 patients was enrolled (median age 70 [IQR: 64, 76.5]). MRI showed sensitivity, specificity, PPV, NPV, and accuracy for MIBC diagnosis ranging from 83-93%, 80-92%, 67-81%, 93-96%, and 84-89% for the more experienced readers. The area under the curve (AUC) was 0.95 (0.91-0.99). In the multivariable logistic regression model, the VI-RADS score, using both a cutoff of 3 and 4 (P < .0001), hematuria (P = .007), tumor size (P = .013), and concomitant hydronephrosis (P = .027) were the variables correlating with a bladder cancer staged as ≥ T2. The inter-reader agreement was substantial (k = 0.814). CONCLUSIONS: VI-RADS assessment scoring proved to be an independent predictor of muscle-invasiveness, which might implicate a shift toward a more aggressive selection approach of patients' at high risk of MIBC, according to a novel proposed predictive pathway.


Assuntos
Neoplasias da Bexiga Urinária , Idoso , Humanos , Imageamento por Ressonância Magnética/métodos , Invasividade Neoplásica/patologia , Estudos Prospectivos , Estudos Retrospectivos , Bexiga Urinária , Neoplasias da Bexiga Urinária/diagnóstico por imagem , Neoplasias da Bexiga Urinária/cirurgia
20.
Int Braz J Urol ; 48(4): 609-622, 2022.
Artigo em Inglês | MEDLINE | ID: mdl-35195385

RESUMO

Bladder cancer (BCa) is one of the most common cancers worldwide and is also considered to be one of the most relapsing and aggressive neoplasms. About 30% of patients will present with muscle invasive disease, which is associated with a higher risk for metastatic disease. The aim of this article is to review the state of art imaging in Radiology, while providing a complete guide to urologists, with case examples, for the rationale of the development of the Vesical Imaging Reporting and Data System (VI-RADS), a scoring system emphasizing a standardized approach to multiparametric Magnetic Resonance Imaging (mpMRI) acquisition, interpretation, and reporting for BCa. Also, we examine relevant external validation studies and the consolidated literature of mpMRI for bladder cancer. In addition, this article discusses some of the potential clinical implications of this scoring system for disease management and follow-up.


Assuntos
Imageamento por Ressonância Magnética Multiparamétrica , Neoplasias da Bexiga Urinária , Humanos , Imageamento por Ressonância Magnética/métodos , Recidiva Local de Neoplasia/patologia , Bexiga Urinária/patologia , Neoplasias da Bexiga Urinária/diagnóstico por imagem , Neoplasias da Bexiga Urinária/patologia , Urologistas
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA