Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Clin Ophthalmol ; 18: 517-523, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38410631

RESUMO

Objective: To investigate the association between the peripheral refractive errors of the fundus in different regions and moderate and high myopia. Methods: In this case-control study, 320 children and adolescents aged 6 to 18 years were recruited. Peripheral refractive errors were measured using multispectral retinal refractive topography (MRT). Spherical equivalent (SE) and cylinder errors were classified into low, moderate, and high categories based on the magnitude range. Logistic regression was performed to test the factors associated with myopia. Results: There were 152 participants with low myopia and 168 participants with moderate and high myopia included in the current study. Participants with moderate and high myopia were most likely to be older, with larger axial length (AL), lower SE, less time to watch electronic devices on the weekend, a higher difference between central refractive error and paracentral refractive error from the superior side of the retina (RDV-S), but a smaller difference between the central refractive error and paracentral refractive error from the inferior side of the retina (RDV-I) than those with low myopia (all P <0.05). After logistic analysis, female sex (odds ratio [OR] = 4.14; 95% confidence interval [CI] = 2.16-7.97, P <0.001), AL (OR = 6.88, 95% CI = 4.33-10.93, P <0.001), and RDV-I (OR = 0.52, 95% CI = 0.32-0.86, P = 0.010) were independent factors for moderate and high myopia. Conclusion: Our study demonstrated that the retina peripheral refraction of the eyes (RDV-I) was associated with moderate and high myopia, and RDV-S was only associated with high myopia.

2.
Photodiagnosis Photodyn Ther ; 43: 103646, 2023 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-37271487

RESUMO

BACKGROUND: To compare the characteristics of biometric measurements among the LS900, IOL Master, and OPD-SCAN III in patients with mild-to-moderate cataract. METHODS: We recruited 85 eyes of 78 patients diagnosed with mild-to-moderate cataract at our hospital between January and April 2023. The K (average corneal curvature; K1 and K2), astigmatism (AST), and white to white (WTW) were measured using those three devices, respectively. Differences and correlations between those measures based on the device were explored. RESULTS: The K1, K2, and AST were highly consistent among the groups (P = 0.851, P = 0.626, P = 0.473, respectively). The WTW measured by IOL Master were larger than those measured by the LS900 and OPD-SCAN III (all P < 0.001). However, all three devices were highly correlated in all measures (P < 0.001). Bland-Altman plots indicated a significant agreement between three devices in all measurements (P < 0.001). CONCLUSIONS: K1, K2, and AST in patients with mild-to-moderate cataract were similar among all three devices, whereas the WTW were not. WTW measurement differences between three devices should be concerned in cataract cases.


Assuntos
Catarata , Fotoquimioterapia , Humanos , Tomografia de Coerência Óptica , Reprodutibilidade dos Testes , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes , Catarata/diagnóstico , Biometria
3.
Photodiagnosis Photodyn Ther ; 41: 103207, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-36414150

RESUMO

PURPOSE: To compare the inter-device agreement of anterior eye segment measurements between LenStar LS 900 optical biometer and OPD Scan III wavefront aberrometer. METHODS: This is a retrospective study involving 59 patients (78 eyes) with cataract. Their angle Alpha, angle Kappa, pupil size and white-to-white (WTW) distance were measured by LenStar LS 900 optical biometer and OPD Scan III wavefront aberrometer, respectively, and pairwise agreement comparisons were performed between them. RESULTS: The most agreement of various parameters was occurred, with intraclass correlation coefficient (ICC) of WTW = 0.930; angle Alpha = 0.853; angle Kappa = 0.898; and pupil size = 0,976 in bright environment. Furthermore, in dark environment, the ICC of WTW, angle Alpha, angle Kappa, and pupil size were 0.927, 0.791, 0.915, and 0.990, respectively. Bland-Altman plot showed similar excellent agreement in the outcomes of the two devices for these measurements testing. CONCLUSIONS: There was an excellent agreement between the LenStar LS 900 optical biometer and OPD Scan III wavefront aberrometer for WTW, angle Alpha, angle Kappa, and pupil size measurements. In clinical practice, these measurements obtained by LenStar LS 900 optical biometer and OPD Scan III wavefront aberrometer can be used interchangeably.


Assuntos
Catarata , Fotoquimioterapia , Humanos , Estudos Retrospectivos , Tomografia de Coerência Óptica , Biometria , Reprodutibilidade dos Testes , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes , Catarata/diagnóstico
4.
Photodiagnosis Photodyn Ther ; 42: 103303, 2023 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-36690195

RESUMO

OBJECTIVE: To analyze the influence factors of the area of superficial plexus foveal avascular zone (FAZ) and related indexes of fovea measured with optical coherence tomography angiography (OCT-A) in normal subjects. METHODS: This was a cross-sectional study from November 2020 to May 2021 in the Inner Mongolia Autonomous Region, China. Each subject received related eye examination. The correlation between all the factors and superficial plexus FAZ were analyzed under univariable and multivariable linear regression analysis. RESULTS: Finally, 239 subjects with sufficient data were recruited in the study, including 108 males and 131 females, aged 27.41±4.63 years. The area of superficial plexus FAZ was 0.33±0.16 mm2. In the univariate regression, gender (ß = 41.702, 95%CI: 9.152 to 74.253, P = 0.012), drinking (ß = -66.074, 95%CI: -99.197 to -32.951, P = 0.001) and axial length (ß = -15.874, 95%CI: -29.562 to -2.185, P = 0.023) were associated with superficial plexus FAZ area. In multivariate regression analysis results, drinking (ß = -42.410, 95%CI = -79.388 to -5.432, P = 0.025) was significantly correlated with superficial plexus FAZ area. CONCLUSION: The area of superficial plexus FAZ was not affected by age, gender, systematical and biochemical indicators, but related to the status of drinking.


Assuntos
Fotoquimioterapia , Tomografia de Coerência Óptica , Masculino , Feminino , Humanos , Angiofluoresceinografia/métodos , Tomografia de Coerência Óptica/métodos , Estudos Transversais , Fotoquimioterapia/métodos , Fármacos Fotossensibilizantes , Fóvea Central/diagnóstico por imagem , Fóvea Central/irrigação sanguínea
5.
Medicine (Baltimore) ; 99(37): e22171, 2020 Sep 11.
Artigo em Inglês | MEDLINE | ID: mdl-32925785

RESUMO

The correlations between retinal vessel distribution, anterior chamber depth (ACD) and other myopic eye structural parameters remains elusive. This study aims to investigate retinal vasculature and eye structure correlations in healthy and myopic eyes of Chinese young adults.In this cross-sectional study, 181 eyes (97 adults) were recruited. Macular and peripapillary vasculature was quantified by optical coherence tomography angiography. Correlations between retinal vasculature and eye structure were analyzed using multivariable linear regression.There were significant differences in ACD, spherical equivalent, axial length (AL), superficial macular vascular density (MVD), peripapillary vascular density (PVD) and circumference of foveal avascular zone (FAZ) among emmetropia, low-myopia, moderate-myopia, and high-myopia groups (both P < 0.05). Furthermore, ACD had significant positive correlation with AL and FAZ, but negative correlation with PVD. MVD also had a negative correlation with AL (beta = -0.247, P < .001). In addition, there was a significant negative correlation between circumference of the FAZ and spherical equivalent as well as central subfield thickness (beta = -0.20, P = .005; beta = -0.334, P < .001, respectively).The degree of myopia affected ACD, MVD, PVD, and circumference of the FAZ in eyes of young healthy adults. Meanwhile, ACD has a positive, while retinal vascular system measurements have a negative correlation with increasing severity of myopia.


Assuntos
Olho/irrigação sanguínea , Olho/patologia , Miopia/patologia , Vasos Retinianos/patologia , Adolescente , Adulto , Fatores Etários , Glicemia , Capilares/patologia , Estudos Transversais , Feminino , Humanos , Lipídeos/sangue , Masculino , Estudos Prospectivos , Índice de Gravidade de Doença , Fatores Sexuais , Tomografia de Coerência Óptica , Adulto Jovem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA