1.
J Wound Ostomy Continence Nurs ; 44(2): 138-141, 2017.
Artigo em Inglês | MEDLINE | ID: mdl-28267119

RESUMO

Medical devices have been identified as an extrinsic risk factor for development of pressure injuries, with as many as 30% to 70% of medical device-related pressure injuries resulting from respiratory equipment. This article describes a quality improvement project undertaken to reduce the occurrence of respiratory device-related pressure injuries in a critically care unit. Multiple actions were implemented to achieve this goal. Respiratory therapists were trained to document occurrences on a daily basis, and apparent cause analyses were conducted on each occurrence. An interdisciplinary team conducted biweekly rounds on patients with respiratory devices and consulted other professionals as indicated. Nurses and respiratory therapists attended an evidence-based, collaborative, educational offering and completed a measure of team functioning before the program and at the end of the study period. The occurrence rates of respiratory device-related pressure injuries were reduced over the project period, and these changes were sustained over the subsequent 12 months.


Assuntos
Cuidados Críticos/normas , Segurança de Equipamentos/métodos , Úlcera por Pressão/prevenção & controle , Melhoria de Qualidade , Respiração Artificial/efeitos adversos , Segurança de Equipamentos/enfermagem , Humanos , Unidades de Terapia Intensiva/organização & administração , Rhode Island
2.
Dimens Crit Care Nurs ; 31(5): 301-8, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22874549

RESUMO

The purpose of this study was to examine the impact of 0.12% chlorhexidine rinses and an oral care protocol on ventilator-associated pneumonia rates. A quasi-experimental preintervention-postintervention design was used. The sample included all patients admitted to critical care and on mechanical ventilation at any time during the study period. Data were collected 6 months before and 12 months after intervention. Ventilator-associated pneumonia rates were reduced from 4.3 to 1.86 per 1000 ventilator-days during the study period, with an estimated cost avoidance of $700,000 to $798,000.


Assuntos
Clorexidina/uso terapêutico , Infecção Hospitalar/prevenção & controle , Controle de Infecções/métodos , Higiene Bucal/métodos , Pneumonia Associada à Ventilação Mecânica/etiologia , Respiração Artificial/efeitos adversos , Humanos , Controle de Infecções/economia , Unidades de Terapia Intensiva/economia , Unidades de Terapia Intensiva/normas , Auditoria de Enfermagem , Higiene Bucal/normas , Pneumonia Associada à Ventilação Mecânica/prevenção & controle , Respiração Artificial/enfermagem