Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
J Am Heart Assoc ; 10(24): e021893, 2021 12 21.
Artigo em Inglês | MEDLINE | ID: mdl-34873927

RESUMO

Background Objective markers of cardiac function are limited in the outpatient setting and may be beneficial for monitoring patients with chronic cardiac conditions. We assess the accuracy of a scale, with the ability to capture ballistocardiography, electrocardiography, and impedance plethysmography signals from a patient's feet while standing on the scale, in measuring stroke volume and cardiac output compared with the gold-standard direct Fick method. Methods and Results Thirty-two patients with unexplained dyspnea undergoing level 3 invasive cardiopulmonary exercise test at a tertiary medical center were included in the final analysis. We obtained scale and direct Fick measurements of stroke volume and cardiac output before and immediately after invasive cardiopulmonary exercise test. Stroke volume and cardiac output from a cardiac scale and the direct Fick method correlated with r=0.81 and r=0.85, respectively (P<0.001 each). The mean absolute error of the scale estimated stroke volume was -1.58 mL, with a 95% limits of agreement of -21.97 to 18.81 mL. The mean error for the scale estimated cardiac output was -0.31 L/min, with a 95% limits of agreement of -2.62 to 2.00 L/min. The changes in stroke volume and cardiac output before and after exercise were 78.9% and 96.7% concordant, respectively, between the 2 measuring methods. Conclusions In a proof-of-concept study, this novel scale with cardiac monitoring abilities may allow for noninvasive, longitudinal measures of cardiac function. Using the widely accepted form factor of a bathroom scale, this method of monitoring can be easily integrated into a patient's lifestyle.


Assuntos
Débito Cardíaco , Monitorização Fisiológica , Volume Sistólico , Estudos de Viabilidade , Humanos , Monitorização Fisiológica/métodos
3.
Plast Reconstr Surg ; 127(1): 117-130, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21200206

RESUMO

BACKGROUND: The purpose of this study was to investigate the capabilities of a novel optical wide-field imaging technology known as spatial frequency domain imaging to quantitatively assess reconstructive tissue status. METHODS: Twenty-two cutaneous pedicle flaps were created on 11 rats based on the inferior epigastric vessels. After baseline measurement, all flaps underwent vascular ischemia, induced by clamping the supporting vessels for 2 hours (either arteriovenous or selective venous occlusions); normal saline was injected into the control flap and hypertonic-hyperoncotic saline solution was injected into the experimental flap. Flaps were monitored for 2 hours after reperfusion. The spatial frequency domain imaging system was used for quantitative assessment of flap status over the duration of the experiment. RESULTS: All flaps demonstrated a significant decline in oxyhemoglobin and tissue oxygen saturation in response to occlusion. Total hemoglobin and deoxyhemoglobin were increased markedly in the selective venous occlusion group. After reperfusion and the administration of solutions, oxyhemoglobin and tissue oxygen saturation in those flaps that survived gradually returned to baseline levels. However, flaps for which oxyhemoglobin and tissue oxygen saturation did not show any signs of recovery appeared to be compromised and eventually became necrotic within 24 to 48 hours in both occlusion groups. CONCLUSIONS: Spatial frequency domain imaging technology provides a quantitative, objective method of assessing tissue status. This study demonstrates the potential of this optical technology to assess tissue perfusion in a very precise and quantitative way, enabling wide-field visualization of physiologic parameters. The results of this study suggest that spatial frequency domain imaging may provide a means for prospectively identifying dysfunctional flaps well in advance of failure.


Assuntos
Espectroscopia de Luz Próxima ao Infravermelho , Retalhos Cirúrgicos/irrigação sanguínea , Animais , Hemoglobinas/análise , Masculino , Necrose , Fenômenos Ópticos , Oxigênio/análise , Oxiemoglobinas/análise , Ratos , Ratos Sprague-Dawley , Pele/irrigação sanguínea , Pele/patologia , Retalhos Cirúrgicos/patologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA