Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 48
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 32(11): 2943-2952, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34455655

RESUMO

INTRODUCTION: The distance from the descending aorta (DA) to the posterior wall of the left atrium (LA) is variable. We aimed to determine whether the proximity between the DA and the left inferior pulmonary vein (LIPV) ostium has an impact on biophysical parameters and cryoballoon (CB) ablation efficacy during LIPV freezing. METHODS: Patients referred for CB-ablation of atrial fibrillation (AF) in two high-volume centers were included. Cryoablation data were collected prospectively for each patient. The anatomical relationships between the LIPV and the DA (distance LIPV ostium-DA, presence of an aortic imprint on the posterior aspect of the LIPV) were then retrospectively analysed on the LA computed tomography scans realized before AF ablation. RESULTS: A total of 350 patients were included (70% men, 59.7 ± 11.5 years). The decrease in the Ostium-DA distance was significantly correlated to the increase in the time-to-isolation (TTI) (r = -.31; p = .036), with less negative temperature (r = -.11; p = .045). Similarly, the presence of an aortic imprint on the LIPV was associated with a longer TTI (p < .001). The analysis of redo procedures data shows a trend toward the presence of shorter ostium-DA distances (15.3 ± 3.29 vs. 18.1 ± 4.99, p = .15) and more frequent aortic imprints (63.6% vs. 47.5%, p = .34) in patients with LIPV reconnection as opposed to patients without reconnection in the LIPV. CONCLUSION: Our findings indicated that the DA seems to have a "radiator" effect influencing LIPV cryoablation parameters during CB-ablation. Additional studies will be needed to elucidate whether this biophysical influence has a clinical impact in LIPVs reconnections.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Idoso , Aorta Torácica , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/cirurgia , Recidiva , Estudos Retrospectivos , Resultado do Tratamento
2.
Europace ; 22(3): 375-381, 2020 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-31808520

RESUMO

AIMS: Although cryoballoon pulmonary vein isolation is a well-established treatment for paroxysmal atrial fibrillation (AF), it's role in persistent AF is unclear. We examined procedural success and long-term outcomes of cryoablation in persistent and longstanding persistent AF. METHODS AND RESULTS: International multicentre registry from three UK and eight European centres. Consecutive patients undergoing cryoablation for persistent AF included. Procedural data, complications, and follow-up were prospectively recorded. Patients were followed-up at 3, 6, and 12 months with an electrocardiogram with open access to arrhythmia nurses thereafter. Ambulatory monitoring was dictated by symptoms. Success was defined as freedom from AF or atrial tachycardia lasting >30 s off antiarrhythmic drugs (AADs). Six hundred and nine consecutive cryoablation procedures. Mean procedure and fluoroscopy times were 95 ± 65 and 13 ± 10 min. Single procedure success rates were 368/602 (61%) off AADs over a median of 2.4 (1.0-4.0) years. Arrhythmia-free survival off AADs was 64% and 57% for persistent and longstanding persistent AF at 24 months of follow-up (P = 0.02). Rate of repeat ablations was 20% in persistent and 32% in longstanding persistent AF (P = 0.006). Cox regression analyses showed a significant association between duration of AF and left atrial diameter and arrhythmia recurrence [hazard ratio (HR) 1.05, P-value 0.01 and HR 1.02, P-value 0.004]. CONCLUSION: Cryoablation for persistent AF is safe, fast and has good outcomes at long-term follow-up. Cryoablation is reasonable as a first line option for these patients. Short procedure times may help increase capacity of cardiac units to meet the rising demand for AF ablation. Randomised control trials are needed to compare outcomes with different techniques.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Sistema de Registros , Resultado do Tratamento
3.
Europace ; 21(5): 803-809, 2019 May 01.
Artigo em Inglês | MEDLINE | ID: mdl-30624630

RESUMO

AIMS: Ventricular tachycardia (VT) ablation has been proven to be effective and safe to avoid arrhythmia recurrences in patients with repaired congenital heart disease (CHD). However, some of these patients may present right ventricular (RV) access issues [agenesia or thrombosis of inferior vena cava (IVC)], making impossible to access the right ventricle through an inferior approach. In such patients, only a superior approach would theoretically be feasible. METHODS AND RESULTS: All VT ablations performed through a jugular or subclavian approach in CHD patients between 2012 and 2017 were included. Among 247 patients scheduled for VT ablation, two patients underwent three VT ablation procedures via a superior approach for due to the inability to access the right ventricle through a conventional IVC access (IVC interruption with azygos continuation in one patient and IVC thrombosis in the other). Ablation was performed using a three-dimensional system through a superior approach, using a subclavian access in both cases. A redo ablation had to be performed in the first patient using a jugular approach. Large curve catheters were used to facilitate RV outflow tract access. Supposed critical isthmuses could be localized and ablated. Patients remained free from arrhythmias during follow-up. CONCLUSION: In patients with repaired CHD and 'no femoral access', ablation of RV tachycardia can be performed using a subclavian or a jugular approach. Mapping may be challenging, requiring large curve catheters. Conventional isthmuses can be mapped and ablated successfully, and such patients should not be denied radiofrequency ablation.


Assuntos
Ablação por Cateter , Cateterismo Periférico , Veias Jugulares/cirurgia , Veia Subclávia/cirurgia , Taquicardia Ventricular , Adulto , Mapeamento Potencial de Superfície Corporal/métodos , Ablação por Cateter/instrumentação , Ablação por Cateter/métodos , Cateterismo Periférico/instrumentação , Cateterismo Periférico/métodos , Feminino , Cardiopatias Congênitas/cirurgia , Humanos , Masculino , Estudos Retrospectivos , Prevenção Secundária/métodos , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/prevenção & controle , Taquicardia Ventricular/cirurgia , Resultado do Tratamento
4.
Europace ; 20(7): 1115-1121, 2018 07 01.
Artigo em Inglês | MEDLINE | ID: mdl-29016748

RESUMO

Aims: Pulmonary vein isolation (PVI) using second-generation cryoballoon (CB2) is associated with improved outcomes compared with first generation (CB1). We aimed at investigating the characteristics of left and right PV reconnections after CB1 and CB2 ablations in patients with clinical recurrences requiring redo ablation. Methods and results: From 2010 to 2016, 776 patients underwent 28-mm cryoballoon PVI for symptomatic paroxysmal atrial fibrillation (AF) in 3 centres, 279 with CB1 and 497 with CB2. Among them, 94 patients (12.1%) had symptomatic AF recurrences requiring a redo ablation [43 (15.4%) CB1 and 51 (10.3%) CB2]. The benefit of CB2 over CB1 was compared for each PV. Durable PVI was confirmed in 7 CB1 (16.3%) and 14 CB2 (27.4%) patients, and 2.7 ± 2.1 and 1.4 ± 1.4 gaps per patient were found, respectively (P = 0.002). Significantly more left superior and left inferior PVs were found to be isolated in CB2 compared with CB1 group (78.4% vs. 48.8%, P = 0.005 and 78.4% vs. 46.5%, P = 0.003, respectively) while the rate of durable right superior and right inferior PVs isolation were similar (68.6% vs. 60.5%, P = 0.542 and 66.7% vs. 55.8%, P = 0.387, respectively). Significantly fewer gaps were found in left PVs in CB2 patients, while there was no significant difference for right PVs. Gaps localization was similar in both groups. Conclusion: Fewer reconnection gaps are observed during redo ablations of paroxysmal AF in patients primarily ablated with CB2. This difference is driven by less reconnection gaps observed in both left PVs, while no difference was observed for right PVs.


Assuntos
Fibrilação Atrial/cirurgia , Cateteres Cardíacos , Ablação por Cateter/instrumentação , Criocirurgia/instrumentação , Veias Pulmonares/cirurgia , Potenciais de Ação , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Ablação por Cateter/efeitos adversos , Criocirurgia/efeitos adversos , Desenho de Equipamento , Feminino , França , Frequência Cardíaca , Humanos , Masculino , Pessoa de Meia-Idade , Veias Pulmonares/fisiopatologia , Recidiva , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
5.
Europace ; 20(2): 362-369, 2018 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-28017936

RESUMO

Aims: Studies assessing radiofrequency ablation (RFA) of ventricular tachycardia (VT) in arrhythmogenic right ventricular cardiomyopathy (ARVC) report VT recurrences, but have not evaluated the impact of RFA on relevant clinical events during follow-up. We aimed to investigate relevant RFA outcomes in a multicentric registry. Methods and results: This study included 49 patients with ARVC (46 with definite diagnosis, 3 with borderline diagnosis according to revised Task Force Criteria) who underwent 92 RFA procedures (83 endocardial, 9 combined endo-epicardial) between 1999-2015. Ventricular tachycardia recurrences and VT burden were assessed after each procedure or after the last RFA. Over a mean follow-up of 64 ± 51 months, VT-free survival was 37% at 1 year, 19% at 5 years, and 14% at 10 years. Ventricular tachycardia burden was significantly reduced after one procedure (23 vs. 11 VT episodes/year, P < 0.01) and after the last RFA (14 vs. 2 VT episodes/year, P < 0.01). Over a mean follow-up of 49 ± 52 months, clinical response after the last RFA (freedom from sudden cardiac death, VT requiring hospitalization, or heart transplantation) was 86% at 1 year, 69% at 5 years, and 60% at 10 years. Clinical response was associated with right ventricular dysfunction (RVD) and low numbers of mappable VT before the first RFA. Conclusion: RFA was predominantly targeted at the endocardial surface. Ventricular tachycardia recurrences were common, but few ARVC patients experienced major clinical events during follow-up. Further studies should investigate the benefit of extensive substrate ablation combined with endo-epicardial strategies.


Assuntos
Displasia Arritmogênica Ventricular Direita/complicações , Ablação por Cateter , Taquicardia Ventricular/cirurgia , Adulto , Displasia Arritmogênica Ventricular Direita/diagnóstico , Displasia Arritmogênica Ventricular Direita/fisiopatologia , Ablação por Cateter/efeitos adversos , Intervalo Livre de Doença , Feminino , França , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/fisiopatologia , Fatores de Tempo , Resultado do Tratamento
6.
Europace ; 19(1): 48-57, 2017 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-27267554

RESUMO

AIM: Cryoballoon ablation (Cryoballoon) has emerged as a new alternative for the treatment of symptomatic drug-refractory atrial fibrillation (AF). Whether the results of Cryoballoon are more reproducible than those of radiofrequency (RF) ablation remains to be proved. METHODS AND RESULTS: A total of 860 consecutive patients undergoing a first ablation procedure for paroxysmal AF (467 treated with RF and 393 treated with Cryoballoon) were selected from a prospective multicentre survey of AF ablation (FrenchAF). Radiofrequency and Cryoballoon were compared regarding mid-term efficacy and safety. During a median follow-up of 14 months (interquartile range 8-23), patients treated with Cryoballoon displayed similar rates of freedom from atrial arrhythmia relapse in centres performing this technique (68-80% at 18 months). However, in centres performing RF, a greater heterogeneity in procedural results was observed (46-79% were free from atrial arrhythmia relapse at 18 months). On multivariate analysis, Cryoballoon (HR = 0.47, 95% CI 0.35-0.65, P < 0.001) and annual AF ablation caseload (HR = 0.87 per every 100 AF ablation procedures per year; 95% CI 0.80-0.96, P = 0.003) were independent predictors of procedural success. However, on sensitivity analysis, according to the ablation method, annual AF ablation caseload predicted only sinus rhythm maintenance in the subgroup of patients treated with RF. Analysis of interoperator results with Cryoballoon and RF confirmed lower reproducibility of RF, but suggested that besides caseload, other operator-related factors may play a role. CONCLUSION: Cryoballoon seems to be less operator-dependent and more reproducible than RF in the setting of paroxysmal AF ablation.


Assuntos
Fibrilação Atrial/cirurgia , Ablação por Cateter , Criocirurgia , Idoso , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/fisiopatologia , Cateteres Cardíacos , Ablação por Cateter/efeitos adversos , Ablação por Cateter/instrumentação , Distribuição de Qui-Quadrado , Competência Clínica , Criocirurgia/efeitos adversos , Criocirurgia/instrumentação , Intervalo Livre de Doença , Desenho de Equipamento , Feminino , França , Pesquisas sobre Atenção à Saúde , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Análise Multivariada , Modelos de Riscos Proporcionais , Estudos Prospectivos , Recidiva , Sistema de Registros , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Carga de Trabalho
8.
Am Heart J ; 178: 161-7, 2016 08.
Artigo em Inglês | MEDLINE | ID: mdl-27502864

RESUMO

Non-vitamin K oral anticoagulants (NOACs) are currently recommended for patients with nonvalvular atrial fibrillation since the publication of the 4 major pivotal trials evaluating the efficacy and safety of factor IIa and factor Xa inhibitors. The definition of nonvalvular atrial fibrillation is unclear, varying from one trial to another and even between North American and European guidelines, which is a source of uncertainties in clinical practice. However, many patients with atrial fibrillation present signs of valvular involvement, and clarification of this term is needed to not deny NOACs to patients based on the wrong perception that they may have valvular atrial fibrillation. The currently unique contraindications to NOACs are patients with mechanical heart valves and those with moderate-to-severe mitral stenosis, as stated by the recent 2015 position paper of the European Heart Rhythm Association. Patients with native heart valve involvement, regardless of their severity, are suitable for NOAC therapy. Patients with bioprosthetic heart valves and mitral valve repair may be suitable for NOACs except for the first 3 and the first 3-6 months postoperatively, respectively. Patients with transaortic valve implantation or percutaneous transluminal aortic valvuloplasty are also considered as being eligible for NOACs, although the bleeding risk has to be carefully considered in this population often requiring a combination with antiplatelet therapy. Future studies are warranted to increase the level of evidence of use of NOACs, particularly in patients with transaortic valve implantation and valvular surgery, and to determine whether they could be used in the future in the only 2 remaining contraindications.


Assuntos
Fibrilação Atrial/classificação , Antitrombinas , Fibrilação Atrial/tratamento farmacológico , Fibrilação Atrial/etiologia , Bioprótese , Contraindicações , Inibidores do Fator Xa , Doenças das Valvas Cardíacas/complicações , Próteses Valvulares Cardíacas , Humanos , Estenose da Valva Mitral/complicações , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle
9.
Basic Res Cardiol ; 109(6): 446, 2014.
Artigo em Inglês | MEDLINE | ID: mdl-25341504

RESUMO

Brugada syndrome (BrS) is characterized by ST-segment elevation in the right precordial leads and is associated with increased risk of sudden cardiac death. We have recently reported families with BrS and SCN5A mutations where some affected members do not carry the familial mutation. We evaluated the involvement of additional genetic determinants for BrS in an affected family. We identified three distinct gene variants within a family presenting BrS (5 individuals), cardiac conduction defects (CCD, 3 individuals) and shortened QT interval (4 individuals). The first mutation is nonsense, p.Q1695*, lying within the SCN5A gene, which encodes for NaV1.5, the α-subunit of the cardiac Na(+) channel. The second mutation is missense, p.N300D, and alters the CACNA1C gene, which encodes the α-subunit CaV1.2 of the L-type cardiac Ca(2+) channel. The SCN5A mutation strictly segregates with CCD. Four out of the 5 BrS patients carry the CACNA1C variant, and three of them present shortened QT interval. One of the BrS patients carries none of these mutations but a rare variant located in the ABCC9 gene as well as his asymptomatic mother. Patch-clamp studies identified a loss-of-function of the mutated CaV1.2 channel. Western-blot experiments showed a global expression defect while increased mobility of CaV1.2 channels on cell surface was revealed by FRAP experiments. Finally, computer simulations of the two mutations recapitulated patient phenotypes. We report a rare CACNA1C mutation as causing BrS and/or shortened QT interval in a family also carrying a SCN5A stop mutation, but which does not segregate with BrS. This study underlies the complexity of BrS inheritance and its pre-symptomatic genetic screening interpretation.


Assuntos
Síndrome de Brugada/genética , Canais de Cálcio Tipo L/genética , Mutação , Canal de Sódio Disparado por Voltagem NAV1.5/genética , Adulto , Idoso de 80 Anos ou mais , Animais , Células COS , Chlorocebus aethiops , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Linhagem , Adulto Jovem
10.
Artigo em Inglês | MEDLINE | ID: mdl-39079606

RESUMO

Quinidine, the first antiarrhythmic drug, was widely used during the 20th century. Multiple studies have been conducted to provide insights into the pharmacokinetics and pleiotropic effects of Class Ia antiarrhythmic drugs. However, safety concerns and the emergence of new drugs led to a decline in their use during the 1990s. Despite this, recent studies have reignited the interest in quinidine, particularly for ventricular arrhythmias, where other antiarrhythmics have failed. In conditions such as Brugada syndrome, idiopathic ventricular fibrillation, early repolarization syndrome, short QT syndrome, and electrical storms, quinidine remains a valuable asset. Starting from the European and American recommendations, this comprehensive review aimed to explore the various indications for quinidine and the studies that support its use. We also discuss the potential future of quinidine, including the necessary research to optimize its use and patient selection. Additionally, it addresses the imperative task of mitigating the iatrogenic burden associated with quinidine usage and confronts the challenge of ensuring drug accessibility.

11.
Artigo em Inglês | MEDLINE | ID: mdl-39093275

RESUMO

BACKGROUND: Electrical storm (ES) is a life-threatening condition, associated with substantial early and subacute mortality. Catheter ablation (CA) is a well-established therapy for ES. However, data regarding the impact of CA on the short-term and midterm survival of patients admitted for ES remain unclear. OBJECTIVES: This multicenter study aimed to investigate the impact of CA of ES on survival outcomes, while accounting for key patient characteristics associated with treatment selection. METHODS: A propensity score-matching (PSM) analysis was performed on 780 consecutive patients admitted for ES in 4 tertiary centers. PSM (1:1) based on the main characteristics associated with the use of CA or medical therapy alone was performed, resulting in 2 groups of 288 patients. RESULTS: After PSM, patients who underwent CA (n = 288) and those treated with medical therapy alone (n = 288) did not present any significant differences in the main demographic characteristics, ES presentation, and management. Compared with medical therapy alone, CA was associated with a significantly lower rate of ES recurrence at 1 year (5% vs 26%; P < 0.001). Similarly, CA was associated with a higher 1-year (91% vs 81%; P < 0.001) and 3-year (78% vs 71%; P = 0.017) survival after discharge. In subgroup analyses, effect of ablation therapy remained consistent in patients older than 70 years of age (HR: 0.39; 95% CI: 0.24-0.66), with substantial efficacy in patients with a LVEF <35% (HR: 0.39; 95% CI: 0.27-0.59). CONCLUSIONS: In propensity-matched analyses, this large study shows that CA-based management of patients admitted for ES is associated with a reduction in mortality compared with medical treatment, particularly in patients with a low ejection fraction.

12.
Rev Prat ; 63(2): 207-13, 2013 Feb.
Artigo em Francês | MEDLINE | ID: mdl-23513784

RESUMO

The initial therapy after onset of atrial fibrillation (AF) should always include adequate antithrombotic treatment and control of the ventricular rate. Depending on the patient's course, this strategy may prove insufficient and may then be supplemented by rhythm control using drugs or interventions. Clinical frustration came by clinical trials that have demonstrated that the strategy of maintaining sinus rhythm has no demonstrable value when compared with the "laissez-faire" approach of leaving AF to a permanent form and controlling ventricular rate. These disappointing findings can be considered as paradoxical when considering the severe complications associated with AF in epidemiological studies. New anti-arrhythmic approaches might offer added value but this is still a matter of debate. Non-pharmacological interventions to prevent AF recurrences or to limit its expression have been substantially developed in the past decade. Ablation techniques, usually done percutaneously using a catheter, have proved successful n the treatment of AF, particularly by reducing the symptomatic burden associated with the arrhythmia, to such an extent that a 'cure' may be achieved in some patients with paroxysmal AF.


Assuntos
Arritmias Cardíacas/terapia , Fibrilação Atrial/terapia , Algoritmos , Antiarrítmicos/efeitos adversos , Antiarrítmicos/uso terapêutico , Arritmias Cardíacas/complicações , Fibrilação Atrial/complicações , Contraindicações , Frequência Cardíaca/fisiologia , Humanos , Modelos Biológicos , Prática Profissional
13.
Arch Cardiovasc Dis ; 116(2): 62-68, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-36604192

RESUMO

BACKGROUND: Catheter ablation is a first-line treatment for symptomatic right ventricular outflow tract (RVOT) premature ventricular complexes (PVCs). There is evidence of displacement of the ablation target site during PVCs relative to the location in sinus rhythm (SR). AIM: To analyse the extent of displacement induced by RVOT PVCs and its effect on the ablation sites and the mid-term efficacy of ablation. METHODS: In this multicentre French study, we retrospectively included 18 consecutive adults referred for ablation of RVOT PVCs using a three-dimensional (3D) mapping system. PVC activation maps were performed conventionally (initial map), then each PVC activation point was manually reannotated considering the 3D location on a previous SR beat (corrected map). The ablation-site locations on the initial or the corrected area, including the 10 best activation points, were analysed. Mid-term efficacy was evaluated. RESULTS: The direction of map shift during PVCs relative to the map in SR occurred along a vertical axis in 16 of 18 patients. The mean activation-point displacement for each of the 18 mapped chambers was 5.6±2.2mm. Mid-term recurrence of RVOT PVCs occurred in 5 (28%) patients. In all patients with recurrences, no significant ablation lesion was located on the corrected (true) site of origin. CONCLUSIONS: RVOT PVCs induce a vertical anatomical shift that can mislead physicians about the true location of the arrhythmia's site of origin. Our study highlights the association between mid-term PVC recurrence and the absence of spatial overlap between ablation points and the corrected site of origin.


Assuntos
Ablação por Cateter , Complexos Ventriculares Prematuros , Adulto , Humanos , Complexos Ventriculares Prematuros/diagnóstico , Complexos Ventriculares Prematuros/etiologia , Complexos Ventriculares Prematuros/cirurgia , Estudos Retrospectivos , Ventrículos do Coração/diagnóstico por imagem , Ventrículos do Coração/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Resultado do Tratamento
14.
Circ Arrhythm Electrophysiol ; 16(3): e011354, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36802906

RESUMO

BACKGROUND: Recurrences of atrial fibrillation (AF) after pulmonary vein isolation (PVI) are mainly due to pulmonary vein reconnection. However, a growing number of patients have AF recurrences despite durable PVI. The optimal ablative strategy for these patients is unknown. We analyzed the impact of current ablation strategies in a large multicenter study. METHODS: Patients undergoing a redo ablation for AF and presenting durable PVI were included. The freedom from atrial arrhythmia after pulmonary vein-based, linear-based, electrogram-based, and trigger-based ablation strategies were compared. RESULTS: Between 2010 and 2020, 367 patients (67% men, 63±10 years, 44% paroxysmal) underwent a redo ablation for AF recurrences despite durable PVI at 39 centers. After durable PVI was confirmed, linear-based ablation was performed in 219 (60%) patients, electrogram-based ablation in 168 (45%) patients, trigger-based ablation in 101 (27%) patients, and pulmonary vein-based ablation in 56 (15%) patients. Seven patients (2%) did not undergo any additional ablation during the redo procedure. After 22±19 months of follow-up, 122 (33%) and 159 (43%) patients had a recurrence of atrial arrhythmia at 12 and 24 months, respectively. No significant difference in arrhythmia-free survival was observed between the different ablation strategies. Left atrial dilatation was the only independent factor associated with arrhythmia-free survival (HR, 1.59 [95% CI, 1.13-2.23]; P=0.006). CONCLUSIONS: In patients with recurrent AF despite durable PVI, no ablation strategy used alone or in combination during the redo procedure appears to be superior in improving arrhythmia-free survival. Left atrial size is a significant predictor of ablation outcome in this population.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Masculino , Humanos , Feminino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Átrios do Coração , Reoperação/métodos , Recidiva , Resultado do Tratamento
15.
Rev Port Cardiol ; 41(8): 653-662, 2022 Aug.
Artigo em Inglês, Português | MEDLINE | ID: mdl-36073263

RESUMO

INTRODUCTION AND OBJECTIVES: Ablation of multifocal premature ventricular complexes (PVCs) is challenging. Activation mapping can be performed for the predominant morphology, but may be useless for other less prevalent ones. We aimed to describe the efficacy of an automated pace-mapping software-based ablation strategy for ablating the site of origin of multiple PVC locations. METHODS: Consecutive patients referred for ablation of multifocal PVCs were prospectively enrolled. Spontaneous PVC templates were recorded and a detailed pace-mapping map was generated to spot the site of origin of PVCs. RESULTS: A total of 47 PVCs were targeted in 21 patients (five and 16 patients with three or two PVCs morphologies each, respectively). Detailed pace-mapping comprising 73.5±41.6 different pacing locations was performed (best matching 97.2% [IQR 95.9-98.3%] similar to the clinical PVC). Activation points were acquired if possible, although ablation was only based on pace-mapping in 13 (27.6%) foci. Complete acute procedural success was obtained in 14 (66.7%) patients, while one PVC morphology was deliberately not ablated in five patients (23.8%). After 12.3±9.4 months of follow-up, PVC burden decreased from 24.4±10.4% to 5.6±5.0% (p<0.001). Interestingly, patients with acute procedural failures or with some PVCs deliberately not targeted during the procedure also experienced a significant decrease in PVC burden (30.0±8.9% to 11.9±3.5%, p=0.002). CONCLUSION: Quantitative morphology-matching software can be used to obtain a detailed map identifying the site of origin of each single PVC, and successful ablation can be performed at these sites, even if activation points cannot be obtained due to the paucity of ectopic beats.

16.
Am J Cardiol ; 162: 73-79, 2022 01 01.
Artigo em Inglês | MEDLINE | ID: mdl-34728062

RESUMO

The clinical efficacy of the inhibitors of the renin-angiotensin-aldosterone system (RAAS) as an upstream therapy for atrial fibrillation (AF) prevention is controversial. No study has itemized so far the role of RAAS inhibitors in AF prevention after atrial flutter (AFL) ablation. This trial aims to investigate the effect of ramipril compared with placebo on AF occurrence in patients hospitalized for AFL ablation without structural heart disease. The Prevention of Atrial Fibrillation by Inhibition Conversion Enzyme (ICE) After Radiofrequency Ablation of Atrial Flutter (PREFACE) trial was a prospective, multicenter, randomized, double-blind, double-dummy trial depicting the AF occurrence during a 12-month follow-up as the primary end point. A total of 198 patients hospitalized for AFL ablation were enrolled in the trial and randomized to placebo or ramipril 5 mg/day. Patients were followed up during 1 year after AFL ablation using 1-week Holter electrocardiogram at 3, 6, 9, and 12 months. The intention-to-treat population encompassed 97 patients in the ramipril group and 101 patients in the placebo group. The primary end point, such as AF occurrence during the 1-year follow-up, was not different between the 2 groups (p = 0.96). Secondary end points, including the occurrence of supraventricular arrhythmia (p = 0.50), heart failure, stroke, and death, were not different between the 2 groups. Safety outcome parameters, including serious adverse events leading to treatment disruption (p = 0.10), hypotension, impairment of renal function, and elevated serum potassium level, also were not different between the 2 groups. In conclusion, RAAS inhibition using ramipril does not reduce AF occurrence in patients facing AFL ablation during the 1-year follow-up.


Assuntos
Inibidores da Enzima Conversora de Angiotensina/uso terapêutico , Fibrilação Atrial/prevenção & controle , Flutter Atrial/tratamento farmacológico , Flutter Atrial/cirurgia , Ablação por Cateter , Ramipril/uso terapêutico , Idoso , Fibrilação Atrial/diagnóstico , Método Duplo-Cego , Eletrocardiografia Ambulatorial , Feminino , Seguimentos , Hospitalização , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Recidiva , Resultado do Tratamento
17.
J Arrhythm ; 37(5): 1303-1310, 2021 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-34621429

RESUMO

BACKGROUND: Although less common, typical atrial flutter shares similar pathophysiological roots with atrial fibrillation. Following successful cavo-tricuspid isthmus ablation using radiofrequency, many patients, however, develop atrial fibrillation in the mid-to-long-term. This study sought to assess whether pulmonary vein isolation conducted at the same time as cavo-tricuspid isthmus ablation would significantly modify the atrial fibrillation burden upon follow-up in patients suffering from typical atrial flutter. METHODS: This was a multicenter randomized controlled study involving typical atrial flutter patients with history of non-predominant atrial fibrillation (1 atrial fibrillation episode only, in 67% of population) who were scheduled for cavo-tricuspid isthmus radiofrequency ablation. Patients were randomly assigned to either undergo cavo-tricuspid isthmus ablation alone or cavo-tricuspid isthmus plus pulmonary vein isolation (CTI+). Pulmonary vein isolation was performed using cryoballoon technology. An outpatient consultation with ECG and 1-week Holter monitoring was performed at 3, 6 months, 1 year, and 2 years postprocedure. The primary endpoint was atrial fibrillation recurrences lasting more than 30 s at 2 years postablation. RESULTS: Of the patients enrolled, 36 were included in each group. At 2-year follow-up, the atrial fibrillation recurrence rate was significantly higher in the CTI vs CTI+group (25/36, 69% vs. 12/36, 33% respectively; P < .001), with similar typical atrial flutter recurrence rates. There were no differences in undesirable events, except for transient phrenic nerve palsy reported from three CTI+patients (8.3%). CONCLUSION: Pulmonary vein isolation using cryoballoon technology was proven to significantly reduce the atrial fibrillation incidence at 2 years postcavo-tricuspid isthmus ablation.

18.
Am J Cardiol ; 149: 78-85, 2021 06 15.
Artigo em Inglês | MEDLINE | ID: mdl-33753040

RESUMO

Conduction disturbances remain common following transcatheter aortic valve implantation (TAVI). Aside from high-degree atrioventricular block (HAVB), their optimal management remains elusive. Invasive electrophysiological studies (EPS) may help stratify patients at low or high risk of HAVB allowing for an early discharge or permanent pacemaker (PPM) implantation among patients with conduction disturbances. We evaluated the safety and diagnostic performances of an EPS-guided PPM implantation strategy among TAVI recipients with conduction disturbances not representing absolute indications for PPM. All patients who underwent TAVI at a single expert center from June 2017 to July 2020 who underwent an EPS during the index hospitalization were included in the present study. False negative outcomes were defined as patients discharged without PPM implantation who required PPM for HAVB within 6 months of the initial EPS. False positive outcomes were defined as patients discharged with a PPM with a ventricular pacing percentage <1% at follow-up. A total of 78 patients were included (median age 83.5, 39% female), among whom 35 patients (45%) received a PPM following EPS. The sensitivity, specificity, positive and negative predictive values of the EPS-guided PPM implantation strategy were 100%, 89.6%, 81.5%, and 100%, respectively. Six patients suffered a mechanical HAVB during EPS and received a PPM. These 6 patients showed PPM dependency at follow-up. In conclusion, an EPS-guided PPM implantation strategy for managing post-TAVI conduction disturbances appears effective to identify patients who can be safely discharged without PPM implantation.


Assuntos
Estenose da Valva Aórtica/cirurgia , Bloqueio Atrioventricular/terapia , Bloqueio de Ramo/terapia , Estimulação Cardíaca Artificial/métodos , Técnicas Eletrofisiológicas Cardíacas , Complicações Pós-Operatórias/terapia , Substituição da Valva Aórtica Transcateter , Idoso , Idoso de 80 Anos ou mais , Bloqueio Atrioventricular/fisiopatologia , Bloqueio de Ramo/fisiopatologia , Doença do Sistema de Condução Cardíaco/fisiopatologia , Doença do Sistema de Condução Cardíaco/terapia , Reações Falso-Negativas , Reações Falso-Positivas , Feminino , Humanos , Masculino , Marca-Passo Artificial , Complicações Pós-Operatórias/fisiopatologia , Implantação de Prótese/métodos , Resultado do Tratamento
19.
Eur J Echocardiogr ; 11(10): 845-52, 2010 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-20858660

RESUMO

AIMS: Atrial fibrillation (AF) may induce three kinds of atrial remodelling: morphological, contractile, and electrical. Maintain of sinus rhythm is usually associated with left atrial (LA) volume decrease, but little is known about the evolution of its mechanical properties. We sought to explore LA mechanical and morphological remodelling in patients with lone paroxysmal-AF treated by catheter ablation (CA). METHODS AND RESULTS: We prospectively included 31 patients (56.4 ± 10 years). We also followed 15 age- and gender-matched controls to get normal values. Each patient had a complete echocardiography at baseline and at 3-month and 1-year follow-up. LA-anatomical reverse remodelling was documented: indexed LA volume decreased from 39 mL/m(2) at baseline to 31 mL/m(2) at 1 year (P < 0.001). However, it remained larger than controls (31 vs. 23 mL/m(2), P = 0.001). LA compliance improved (LA lateral systolic peaks of strain = 50 vs. 31%, P < 0.05) without reaching controls values as estimated by 50 vs. 81%, P < 0.05). LA contractility increased as highlighted by A'-peak velocity (10 cm/s at 1Y-F/up vs. 7.5 at baseline, P = 0.01) and LA late diastolic peaks of strain rate (septal: -3 vs. -1 s(-1), lateral: -3 vs. -1.4 s(-1), P < 0.05). We show a functional remodelling at 1 year, with most contractile parameters being comparable to controls, whereas LA compliance remains significantly altered. CONCLUSION: AF-CA could reverse LA anatomical and functional remodelling. Despite improvement, LA compliance remains altered after 1 year, probably reflecting irreversible fibrosis.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/cirurgia , Função do Átrio Esquerdo , Ablação por Cateter , Ecocardiografia Doppler em Cores/métodos , Análise de Variância , Estudos de Casos e Controles , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Reprodutibilidade dos Testes , Estatísticas não Paramétricas
20.
Eur Heart J ; 30(10): 1237-44, 2009 May.
Artigo em Inglês | MEDLINE | ID: mdl-19264750

RESUMO

AIMS: The aim of this study was to investigate the 12-month incidence, predictive factors, and prognosis of sustained ventricular tachycardia (VT) in chronic heart failure patients implanted with biventricular pacemakers without a back-up defibrillator (CRT-P), assessed by continuous intracardiac ventricular electrograms. METHODS AND RESULTS: The Mona Lisa study, a prospective, multicentre, cohort study, designed to determine the incidence of sustained VT and its prognostic impact in CRT-P recipients within the year after implant enrolled 198 patients with moderate or severe chronic heart failure, despite optimal pharmacological therapy. An independent committee reviewed the data from all arrhythmic episodes as well as causes of death according to predefined criteria. During a mean follow-up of 9.8 +/- 3.1 months after implantation, 8 patients experienced at least one episode of sustained VT [4.3%; 95% confidence interval (CI), 1.1-7.5] and 21 deaths occurred, giving a 12-month mortality rate of 11.7% (95% CI, 6.4-16.9). The presence of sustained VT was associated with a high risk of sudden cardiac death (SCD) and the lowest 12-month overall survival (P < 0.0001). CONCLUSION: The incidence of sustained VT remains relatively low in the first year after CRT-P implantation, but when present appears closely associated with short-term adverse outcomes, especially SCD. This emphasizes the possible value of remote monitoring to detect high-risk patients for urgent upgrading.


Assuntos
Morte Súbita Cardíaca/epidemiologia , Insuficiência Cardíaca/terapia , Marca-Passo Artificial , Taquicardia Ventricular/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Estimulação Cardíaca Artificial/efeitos adversos , Causas de Morte , Técnicas Eletrofisiológicas Cardíacas/métodos , Métodos Epidemiológicos , Feminino , Insuficiência Cardíaca/complicações , Insuficiência Cardíaca/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Taquicardia Ventricular/diagnóstico , Taquicardia Ventricular/etiologia , Taquicardia Ventricular/mortalidade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA