Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Mais filtros

Base de dados
Tipo de documento
Intervalo de ano de publicação
1.
BJU Int ; 2024 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-38717014

RESUMO

OBJECTIVE: To investigate and compare the performance of urinary cytology and the Xpert BC Monitor test in the detection of bladder cancer in various clinically significant patient cohorts, including patients with carcinoma in situ (CIS), in a prospective multicentre setting, aiming to identify potential applications in clinical practice. PATIENTS AND METHODS: A total of 756 patients scheduled for transurethral resection of bladder tumour (TURBT) were prospectively screened between July 2018 and December 2020 at six German University Centres. Central urinary cytology and Xpert BC Monitor tests were performed prior to TURBT. The diagnostic performance of urinary cytology and the Xpert BC Monitor was evaluated according to sensitivity (SN), specificity (SC), negative predictive value (NPV) and positive predictive value (PPV). Statistical comparison of urinary cytology and the Xpert BC Monitor was conducted using the McNemar test. RESULTS: Of 756 screened patients, 733 (568 male [78%]; median [interquartile range] age 72 [62-79] years) were included. Bladder cancer was present in 482 patients (65.8%) with 258 (53.5%) high-grade tumours. Overall SN, SC, NPV and PPV were 39%, 93%, 44% and 92% for urinary cytology, and 75%, 69%, 59% and 82% for the Xpert BC Monitor. In patients with CIS (concomitant or solitary), SN, SC, NPV and PPV were 59%, 93%, 87% and 50% for urinary cytology, and 90%, 69%, 95% and 50% for the Xpert BC Monitor. The Xpert BC Monitor missed four tumours (NPV = 98%) in patients with solitary CIS, while potentially avoiding 63.3% of TURBTs in inconclusive or negative cystoscopy and a negative Xpert result. CONCLUSION: Positive urinary cytology may indicate bladder cancer and should be taken seriously. The Xpert BC Monitor may represent a useful diagnostic tool for correctly identifying patients with solitary CIS and unsuspicious or inconclusive cystoscopy.

2.
Proc Natl Acad Sci U S A ; 113(31): 8783-8, 2016 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-27432972

RESUMO

Despite years of plasma HIV-RNA levels <40 copies per milliliter during combination antiretroviral therapy (cART), the majority of HIV-infected patients exhibit persistent seropositivity to HIV-1 and evidence of immune activation. These patients also show persistence of proviruses of HIV-1 in circulating peripheral blood mononuclear cells. Many of these proviruses have been characterized as defective and thus thought to contribute little to HIV-1 pathogenesis. By combining 5'LTR-to-3'LTR single-genome amplification and direct amplicon sequencing, we have identified the presence of "defective" proviruses capable of transcribing novel unspliced HIV-RNA (usHIV-RNA) species in patients at all stages of HIV-1 infection. Although these novel usHIV-RNA transcripts had exon structures that were different from those of the known spliced HIV-RNA variants, they maintained translationally competent ORFs, involving elements of gag, pol, env, rev, and nef to encode a series of novel HIV-1 chimeric proteins. These novel usHIV-RNAs were detected in five of five patients, including four of four patients with prolonged viral suppression of HIV-RNA levels <40 copies per milliliter for more than 6 y. Our findings suggest that the persistent defective proviruses of HIV-1 are not "silent," but rather may contribute to HIV-1 pathogenesis by stimulating host-defense pathways that target foreign nucleic acids and proteins.


Assuntos
Antirretrovirais/uso terapêutico , Infecções por HIV/tratamento farmacológico , HIV-1/efeitos dos fármacos , Provírus/efeitos dos fármacos , RNA Viral/metabolismo , DNA Viral/genética , DNA Viral/metabolismo , Regulação Viral da Expressão Gênica , Infecções por HIV/virologia , HIV-1/genética , HIV-1/fisiologia , Humanos , Leucócitos Mononucleares/virologia , Provírus/genética , RNA Viral/genética , Proteínas Virais/genética , Proteínas Virais/metabolismo
3.
Nat Methods ; 12(8): 780-6, 2015 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-26121404

RESUMO

We present the first comprehensive analysis of a diploid human genome that combines single-molecule sequencing with single-molecule genome maps. Our hybrid assembly markedly improves upon the contiguity observed from traditional shotgun sequencing approaches, with scaffold N50 values approaching 30 Mb, and we identified complex structural variants (SVs) missed by other high-throughput approaches. Furthermore, by combining Illumina short-read data with long reads, we phased both single-nucleotide variants and SVs, generating haplotypes with over 99% consistency with previous trio-based studies. Our work shows that it is now possible to integrate single-molecule and high-throughput sequence data to generate de novo assembled genomes that approach reference quality.


Assuntos
Biologia Computacional/métodos , Genoma Humano , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Polimorfismo de Nucleotídeo Único , Algoritmos , Mapeamento Cromossômico , Diploide , Biblioteca Gênica , Variação Genética , Genoma , Haplótipos , Humanos , Nucleotídeos/genética , Reprodutibilidade dos Testes , Análise de Sequência de DNA , Sequências de Repetição em Tandem
4.
J Clin Microbiol ; 55(4): 1131-1139, 2017 04.
Artigo em Inglês | MEDLINE | ID: mdl-28122870

RESUMO

The efficacy of antiviral treatment for chronic hepatitis C virus (HCV) infection is determined by measuring HCV RNA at specific time points throughout therapy using highly sensitive and accurate HCV RNA assays. This study compared the performances of two recently developed real-time PCR HCV RNA assays, cobas HCV for use on the cobas 6800/8800 systems (cobas 6800/8800 HCV) and cobas HCV for use on the cobas 4800 system (cobas 4800 HCV), with those of two established assays, the Cobas AmpliPrep/Cobas TaqMan HCV quantitative test, version 2 (CAP/CTM v2) and the Cobas TaqMan HCV test, version 2 for use with the High Pure system (HPS/CTM v2). The limits of detection (LODs) and linearity at lower concentrations (5 to 1000 IU/ml) were assessed for cobas 6800/8800 HCV and cobas 4800 HCV using WHO standard traceable panels representing HCV genotypes (GT) 1 to 4. Pairwise assay comparisons were also performed using 245 clinical samples representing HCV GT 1 to GT 4. Results from cobas 6800/8800 HCV and cobas 4800 HCV were linear at low HCV RNA concentrations (<0.3 log10 IU/ml difference between expected and observed results) with LODs of 8.2 IU/ml and 11.7 IU/ml, respectively, for GT 1. The new assays showed excellent agreement with results from CAP/CTM v2 and HPS/CTM v2 in samples with quantifiable viral loads. The concordances using the 6 million IU/ml cutoff were high among all four assays (90 to 94%). In conclusion, the cobas 6800/8800 HCV and cobas 4800 HCV tests are sensitive and linear and correlate well with the established Roche assays used in clinical practice.


Assuntos
Hepacivirus/isolamento & purificação , Hepatite C/virologia , RNA Viral/análise , Carga Viral/métodos , Humanos , Reação em Cadeia da Polimerase em Tempo Real/métodos , Sensibilidade e Especificidade
5.
Appl Environ Microbiol ; 83(3)2017 02 01.
Artigo em Inglês | MEDLINE | ID: mdl-27836852

RESUMO

Listeria monocytogenes is a bacterial pathogen that is found in a wide variety of anthropogenic and natural environments. Genome sequencing technologies are rapidly becoming a powerful tool in facilitating our understanding of how genotype, classification phenotypes, and virulence phenotypes interact to predict the health risks of individual bacterial isolates. Currently, 57 closed L. monocytogenes genomes are publicly available, representing three of the four phylogenetic lineages, and they suggest that L. monocytogenes has high genomic synteny. This study contributes an additional 15 closed L. monocytogenes genomes that were used to determine the associations between the genome and methylome with host invasion magnitude. In contrast to previous findings, large chromosomal inversions and rearrangements were detected in five isolates at the chromosome terminus and within rRNA genes, including a previously undescribed inversion within rRNA-encoding regions. Each isolate's epigenome contained highly diverse methyltransferase recognition sites, even within the same serotype and methylation pattern. Eleven strains contained a single chromosomally encoded methyltransferase, one strain contained two methylation systems (one system on a plasmid), and three strains exhibited no methylation, despite the occurrence of methyltransferase genes. In three isolates a new, unknown DNA modification was observed in addition to diverse methylation patterns, accompanied by a novel methylation system. Neither chromosome rearrangement nor strain-specific patterns of epigenome modification observed within virulence genes were correlated with serotype designation, clonal complex, or in vitro infectivity. These data suggest that genome diversity is larger than previously considered in L. monocytogenes and that as more genomes are sequenced, additional structure and methylation novelty will be observed in this organism. IMPORTANCE: Listeria monocytogenes is the causative agent of listeriosis, a disease which manifests as gastroenteritis, meningoencephalitis, and abortion. Among Salmonella, Escherichia coli, Campylobacter, and Listeria-causing the most prevalent foodborne illnesses-infection by L. monocytogenes carries the highest mortality rate. The ability of L. monocytogenes to regulate its response to various harsh environments enables its persistence and transmission. Small-scale comparisons of L. monocytogenes focusing solely on genome contents reveal a highly syntenic genome yet fail to address the observed diversity in phenotypic regulation. This study provides a large-scale comparison of 302 L. monocytogenes isolates, revealing the importance of the epigenome and restriction-modification systems as major determinants of L. monocytogenes phylogenetic grouping and subsequent phenotypic expression. Further examination of virulence genes of select outbreak strains reveals an unprecedented diversity in methylation statuses despite high degrees of genome conservation.


Assuntos
Metilação de DNA , Enzimas de Restrição-Modificação do DNA/genética , Genoma Bacteriano , Listeria monocytogenes/genética , Genômica , Alinhamento de Sequência , Sintenia
6.
Nucleic Acids Res ; 43(20): e129, 2015 Nov 16.
Artigo em Inglês | MEDLINE | ID: mdl-26101252

RESUMO

Single Molecule, Real-Time (SMRT) Sequencing (Pacific Biosciences, Menlo Park, CA, USA) provides the longest continuous DNA sequencing reads currently available. However, the relatively high error rate in the raw read data requires novel analysis methods to deconvolute sequences derived from complex samples. Here, we present a workflow of novel computer algorithms able to reconstruct viral variant genomes present in mixtures with an accuracy of >QV50. This approach relies exclusively on Continuous Long Reads (CLR), which are the raw reads generated during SMRT Sequencing. We successfully implement this workflow for simultaneous sequencing of mixtures containing up to forty different >9 kb HIV-1 full genomes. This was achieved using a single SMRT Cell for each mixture and desktop computing power. This novel approach opens the possibility of solving complex sequencing tasks that currently lack a solution.


Assuntos
Variação Genética , Genoma Viral , HIV-1/genética , Sequenciamento de Nucleotídeos em Larga Escala/métodos , Análise de Sequência de DNA/métodos , Algoritmos , Análise por Conglomerados , Humanos , Alinhamento de Sequência
7.
N Engl J Med ; 364(1): 33-42, 2011 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-21142692

RESUMO

BACKGROUND: Although cholera has been present in Latin America since 1991, it had not been epidemic in Haiti for at least 100 years. Recently, however, there has been a severe outbreak of cholera in Haiti. METHODS: We used third-generation single-molecule real-time DNA sequencing to determine the genome sequences of 2 clinical Vibrio cholerae isolates from the current outbreak in Haiti, 1 strain that caused cholera in Latin America in 1991, and 2 strains isolated in South Asia in 2002 and 2008. Using primary sequence data, we compared the genomes of these 5 strains and a set of previously obtained partial genomic sequences of 23 diverse strains of V. cholerae to assess the likely origin of the cholera outbreak in Haiti. RESULTS: Both single-nucleotide variations and the presence and structure of hypervariable chromosomal elements indicate that there is a close relationship between the Haitian isolates and variant V. cholerae El Tor O1 strains isolated in Bangladesh in 2002 and 2008. In contrast, analysis of genomic variation of the Haitian isolates reveals a more distant relationship with circulating South American isolates. CONCLUSIONS: The Haitian epidemic is probably the result of the introduction, through human activity, of a V. cholerae strain from a distant geographic source. (Funded by the National Institute of Allergy and Infectious Diseases and the Howard Hughes Medical Institute.).


Assuntos
Cólera/microbiologia , Genes Bacterianos , Vibrio cholerae/classificação , Vibrio cholerae/genética , Cólera/epidemiologia , Mapeamento Cromossômico , Surtos de Doenças , Fezes/microbiologia , Variação Genética , Genoma Bacteriano , Haiti/epidemiologia , História do Século XVIII , Humanos , Filogenia , Análise de Sequência de DNA , Sorotipagem , Vibrio cholerae/isolamento & purificação , Vibrio cholerae O1/genética
8.
N Engl J Med ; 365(8): 709-17, 2011 Aug 25.
Artigo em Inglês | MEDLINE | ID: mdl-21793740

RESUMO

BACKGROUND: A large outbreak of diarrhea and the hemolytic-uremic syndrome caused by an unusual serotype of Shiga-toxin-producing Escherichia coli (O104:H4) began in Germany in May 2011. As of July 22, a large number of cases of diarrhea caused by Shiga-toxin-producing E. coli have been reported--3167 without the hemolytic-uremic syndrome (16 deaths) and 908 with the hemolytic-uremic syndrome (34 deaths)--indicating that this strain is notably more virulent than most of the Shiga-toxin-producing E. coli strains. Preliminary genetic characterization of the outbreak strain suggested that, unlike most of these strains, it should be classified within the enteroaggregative pathotype of E. coli. METHODS: We used third-generation, single-molecule, real-time DNA sequencing to determine the complete genome sequence of the German outbreak strain, as well as the genome sequences of seven diarrhea-associated enteroaggregative E. coli serotype O104:H4 strains from Africa and four enteroaggregative E. coli reference strains belonging to other serotypes. Genomewide comparisons were performed with the use of these enteroaggregative E. coli genomes, as well as those of 40 previously sequenced E. coli isolates. RESULTS: The enteroaggregative E. coli O104:H4 strains are closely related and form a distinct clade among E. coli and enteroaggregative E. coli strains. However, the genome of the German outbreak strain can be distinguished from those of other O104:H4 strains because it contains a prophage encoding Shiga toxin 2 and a distinct set of additional virulence and antibiotic-resistance factors. CONCLUSIONS: Our findings suggest that horizontal genetic exchange allowed for the emergence of the highly virulent Shiga-toxin-producing enteroaggregative E. coli O104:H4 strain that caused the German outbreak. More broadly, these findings highlight the way in which the plasticity of bacterial genomes facilitates the emergence of new pathogens.


Assuntos
Surtos de Doenças , Infecções por Escherichia coli/microbiologia , Genoma Bacteriano , Síndrome Hemolítico-Urêmica/microbiologia , Escherichia coli Shiga Toxigênica/genética , Técnicas de Tipagem Bacteriana , Sequência de Bases , Diarreia/epidemiologia , Diarreia/microbiologia , Infecções por Escherichia coli/epidemiologia , Fezes/microbiologia , Feminino , Alemanha/epidemiologia , Síndrome Hemolítico-Urêmica/epidemiologia , Humanos , Pessoa de Meia-Idade , Filogenia , Reação em Cadeia da Polimerase , Análise de Sequência de DNA , Escherichia coli Shiga Toxigênica/classificação , Escherichia coli Shiga Toxigênica/isolamento & purificação
9.
Bladder Cancer ; 10(1): 25-33, 2024.
Artigo em Inglês | MEDLINE | ID: mdl-38993527

RESUMO

BACKGROUND AND OBJECTIVE: Assessment of patients with hematuria (aH) remains a challenge in urological practice, balancing the benefits of diagnosing a potentially underlying bladder cancer (UCa) against the risks of possibly unnecessary diagnostic interventions. This study analyzes the potential of an mRNA-based urine assay, the Xpert® Bladder Cancer Detection- CE-IVD (Xpert BC-D), in patients with hematuria. MATERIALS AND METHODS: Overall, 368 patients with newly observed painless hematuria and no history of UCa were included in this observational study. Patients received urological workup, including urethrocystoscopy (WLC), upper tract imaging, urine cytology and Xpert BC-D. Patients with positive WLC were recommended to undergo tumor resection (TUR-B). RESULTS: After excluding non-assessable cases, 324 patients were considered for analysis (188 males, 136 females; median age: 61 years). Eight of twenty-eight patients with a positive TUR-B had Ta low grade (LG) tumors; the others were diagnosed with high grade (HG) lesions (Ta: 4, CIS: 2, T1:11, > T1:3). The Xpert BC-D was more sensitive than urine cytology (96% vs. 61%) (p = 0.002). Increased risk ratios (RR) were observed for gross hematuria, gender, urine cytology, and positive Xpert BC-D (all p < 0.05). Age and positive Xpert BC-D remained independent predictors of UCa in multivariate analysis. Simulating a triage with WLC restricted to patients with positive Xpert BC-D could have saved 240 (74.1%) assessments at the cost of missing one pTa LG tumor. CONCLUSIONS: The results suggest a potential role for Xpert BC-D in preselecting patients with hematuria for either further invasive diagnosis or an alternate diagnostic procedure.

10.
Sci Rep ; 13(1): 15437, 2023 09 18.
Artigo em Inglês | MEDLINE | ID: mdl-37723173

RESUMO

To determine whether Xpert bladder cancer monitor, a noninvasive PCR-based biomarker test, can predict the need for 2nd transurethral resection of the bladder (TURB) better than clinical assessment. Patients scheduled for TURB were prospectively screened. After initial TURB, patients were assigned to 2nd TURB or follow-up cystoscopy at 3 months (FU) by clinicians' discretion. Central urine cytology and Xpert monitor tests were performed prior to the 1st TURB and 2nd TURB or FU, respectively. Statistical analysis to compare clinical assessment and Xpert monitor comprised sensitivity (SENS), specificity (SPEC), NPV and PPV. Of 756 screened patients, 171 were included (114 with 2nd TURB, 57 with FU). Residual tumors were detected in 34 patients who underwent 2nd TURB, and recurrent tumors were detected in 2 patients with FU. SENS and SPEC of Xpert monitor were 83.3% and 53.0%, respectively, PPV was 32.6% and NPV was 92.1%. Clinical risk assessment outperformed Xpert monitor. In patients with pTa disease at initial TURB, Xpert monitor revealed a NPV of 96%. Xpert monitor was not superior than clinical assessment in predicting the need for 2nd TURB. It might be an option to omit 2nd TURB for selected patients with pTa disease.


Assuntos
Neoplasias da Bexiga Urinária , Humanos , Neoplasias da Bexiga Urinária/diagnóstico , Bexiga Urinária , Cistoscopia , Neoplasia Residual , Reação em Cadeia da Polimerase
11.
Antimicrob Agents Chemother ; 54(5): 1973-80, 2010 May.
Artigo em Inglês | MEDLINE | ID: mdl-20194692

RESUMO

Recent reports have described the effect of mutations in the connection and RNase H domains of reverse transcriptase (RT) on nucleoside and nonnucleoside reverse transcriptase inhibitor (NRTI and NNRTI, respectively) resistance in the presence of thymidine analog resistance mutations (TAMs) and NNRTI mutations (J. H. Brehm, D. Koontz, J. D. Meteer, V. Pathak, N. Sluis-Cremer, and J. W. Mellors, J. Virol. 81:7852-7859, 2007; K. A. Delviks-Frankenberry, G. N. Nikolenko, R. Barr, and V. K. Pathak, J. Virol. 81:6837-6845, 2007; G. N. Nikolenko, K. A. Delviks-Frankenberry, S. Palmer, F. Maldarelli, M. J. Fivash, Jr., J. M. Coffin, and V. K. Pathak, Proc. Natl. Acad. Sci. U. S. A. 104:317-322, 2007; G. N. Nikolenko, S. Palmer, F. Maldarelli, J. W. Mellors, J. M. Coffin, and V. K. Pathak, Proc. Natl. Acad. Sci. U. S. A. 102:2093-2098, 2005; and S. H. Yap, C. W. Sheen, J. Fahey, M. Zanin, D. Tyssen, V. D. Lima, B. Wynhoven, M. Kuiper, N. Sluis-Cremer, P. R. Harrigan, and G. Tachedjian, PLoS Med. 4:e335, 2007). In the present study, novel mutations in the connection domain of RT (T369I/V), first identified in patient-derived viruses, were characterized, and their effects on NNRTI and NNRTI susceptibility were determined. Furthermore, the effect of N348I on NRTI and NNRTI resistance was confirmed. HIV-1 with either N348I or T369I/V demonstrated reduced susceptibility to nevirapine (NVP), efavirenz (EFV), delaviridine (DLV), and zidovudine (ZDV) compared to wild-type HIV-1. However, HIV-1 with T369I and N348I demonstrated 10- to 60-fold resistance to these same drugs. In clinical samples, these two connection domain RT mutations were predominantly observed in viruses containing TAMs and NNRTI mutations and did not alter the susceptible-resistant classifications of these samples. Introduction of T369I, N348I, or T369I/N348I also reduced replication capacity (RC). These observations suggest that it may be of scientific interest to test these mutations against new NNRTI candidates.


Assuntos
Farmacorresistência Viral/genética , Infecções por HIV/tratamento farmacológico , Transcriptase Reversa do HIV/genética , HIV-1/efeitos dos fármacos , HIV-1/genética , Inibidores da Transcriptase Reversa/farmacologia , Substituição de Aminoácidos , Fármacos Anti-HIV/farmacologia , Genótipo , Infecções por HIV/virologia , Transcriptase Reversa do HIV/química , HIV-1/crescimento & desenvolvimento , Humanos , Mutagênese Sítio-Dirigida , Mutação , Nucleosídeos/genética , Fenótipo , Estrutura Terciária de Proteína , Replicação Viral/efeitos dos fármacos , Produtos do Gene pol do Vírus da Imunodeficiência Humana/genética
12.
Expert Rev Mol Diagn ; 19(10): 941-949, 2019 10.
Artigo em Inglês | MEDLINE | ID: mdl-31159598

RESUMO

Background: Viral load (VL) quantification is important for the management of HBV, HCV, and HIV-1-infected patients. Several semi- or fully automated systems and assays are available that can be used to measure VL for these and other targets. Research design and methods: We assessed the accuracy, genotype/subtype inclusivity, and precision of four VL assays for three viral targets: cobas 4800 (Roche), cobas 6800 (Roche), Aptima (Hologic) and VERIS (Beckman), using WHO standards, cell culture supernatants and clinical samples. Results: Most results were close to expected values, except for significant under-quantification of HIV-1 group O, HBV genotype C, and D at high VL, and HCV genotype 3 by Aptima, and of HIV-1 CRF01_AE and group N and HCV genotype 3 by VERIS. Precision was comparable between tests except for VERIS HCV, which showed more variability. Aptima and cobas 6800 results agreed well with each other except HBV VL at lower VL (<10,000 IU/mL) where Aptima results tended to be higher. Conclusions: Results from different VL assays may not always agree in certain subsets of patients. Clinicians should we aware of these findings when making treatment decisions.


Assuntos
DNA Viral/genética , HIV-1/genética , Hepacivirus/genética , Vírus da Hepatite B/genética , RNA Viral/genética , Carga Viral/genética , Automação Laboratorial/métodos , Genótipo , Humanos , Técnicas de Diagnóstico Molecular/métodos , Kit de Reagentes para Diagnóstico
13.
J Clin Virol ; 114: 43-49, 2019 05.
Artigo em Inglês | MEDLINE | ID: mdl-30991164

RESUMO

BACKGROUND AND OBJECTIVES: Measurement of HIV-1 viral load (VL) is necessary to monitor treatment efficacy in patients receiving antiretroviral therapy. We evaluated the performance of the cobas® HIV-1 quantitative nucleic acid test for use on the cobas® 4800 system ("cobas 4800 HIV-1"). METHODS: Limit of detection, linearity, accuracy, precision, and specificity of cobas 4800 HIV-1, COBAS® AmpliPrep/COBAS® Taqman® HIV-1 version 2.0 (CAP/CTM HIV-1 v2) and Abbott RealTime HIV-1 were determined in one or two out of three sites. RESULTS: The limit of detection of the cobas 4800 HIV-1 for 400 µL and 200 µL input volumes was 14.2 copies/mL (95% CI: 12.5-16.6 copies/mL) and 43.9 copies/mL (37.7-52.7 copies/mL), respectively. Cobas 4800 HIV-1 demonstrated 100% specificity, and results were linear for all analyzed group M HIV-1 subtypes. Precision was high (SD < 0.19 log10) across all measured ranges, reagent lots and input volumes. Correlation between cobas 4800 HIV-1 and CAP/CTM HIV-1 v2 or RealTime HIV-1 was high (R2 ≥ 0.95). Agreement between cobas 4800 HIV-1 and CAP/CTM HIV-1 v2 was 96.5% (95.0%-97.7%) at a threshold of 50 copies/mL, and 97.2% (95.8%-98.3%) at 200 copies/mL. Agreement between cobas 4800 HIV-1 and RealTime HIV-1 was 96.6% (93.4%-98.5%) at 50 copies/mL, and 97.0% (94.0%-98.8%) at 200 copies/mL. The mean difference between cobas 4800 HIV-1 and CAP/CTM HIV-1 v2 or RealTime HIV-1 was -0.10 log10 or 0.01 log10, respectively. CONCLUSIONS: The cobas 4800 HIV-1 test is highly sensitive, accurate and correlated well with other assays, including agreement around clinically relevant thresholds, indicating minimal overall VL quantification differences between tested platforms.


Assuntos
Infecções por HIV/diagnóstico , Técnicas de Amplificação de Ácido Nucleico/normas , Kit de Reagentes para Diagnóstico/normas , Carga Viral/métodos , Carga Viral/normas , Infecções por HIV/sangue , HIV-1 , Humanos , Limite de Detecção , Técnicas de Amplificação de Ácido Nucleico/métodos , RNA Viral/sangue , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
14.
J Clin Virol ; 102: 63-69, 2018 05.
Artigo em Inglês | MEDLINE | ID: mdl-29518694

RESUMO

BACKGROUND AND OBJECTIVES: Accurate, sensitive, and specific tests for detection and monitoring of hepatitis C virus (HCV) RNA concentrations are essential for diagnosis and management of HCV infections. We evaluated the next-generation reverse-transcription real-time PCR test, cobas® HCV test for use with the cobas® 6800/8800 systems ("cobas HCV") by determining its analytical performance characteristics and clinical utility for the diagnosis and therapeutic monitoring of chronic HCV infections. METHODS: The limit of detection (LOD), linearity, precision, specificity, matrix equivalence of plasma and serum, and quantitative agreement with the COBAS® AmpliPrep/COBAS® TaqMan® HCV Test version 2.0 ("CAP/CTM HCV v2") were evaluated. Clinical utility for the diagnosis of chronic HCV infection was demonstrated by testing plasma from HCV seropositive individuals and comparing results to a nucleic acid amplification test (NAAT) approved for use in the diagnosis of chronic hepatitis C. Clinical specificity was investigated by testing plasma from HCV antibody negative subjects with non-HCV related liver diseases. Utility for monitoring treatment response was defined by testing plasma collected during treatment of HCV genotypes (GT) 1, 2, and 3 and determining positive predictive value (PPV), negative predictive value (NPV) and the odds ratio (OR) for predicting cure (sustained virologic response 12 weeks after treatment cessation, "SVR12"). RESULTS: The cobas HCV test demonstrated an LOD of at least 15 IU/mL and measurable range from 15 to at least 1.0E + 08 IU/mL (1.2-8.0 log10 IU/mL) for GT 1-6, with high accuracy (≤0.16 log10 difference) and precision (standard deviation 0.04-0.14 log10) throughout the linear range. Paired plasma and serum samples showed highly correlated performance (R2 = 0.97). Quantification was 100% specific for HCV in analytical studies. Correlation with CAP/CTM HCV v2 was high in patient samples (mean titer difference: 0.05 log10 with a 95% CI: 0.03-0.06 log10). For the diagnosis of chronic HCV, positive and negative percent agreement between cobas HCV and the comparator NAAT were 98.8-100% on the cobas 6800 and 8800 systems. Clinical specificity of cobas HCV using samples from HCV antibody negative subjects with non-HCV related liver diseases was 99.6% and 100% on cobas 6800 and 8800 systems. In therapeutic monitoring and SVR12 prediction during experimental treatment for chronic HCV GT 1 infections, undetectable HCV RNA by cobas HCV at different on-treatment weeks had a PPV 76.8%-79.4%, NPV 29.9%-100%, and OR 1.64-47.52. During therapy of HCV GT 2 and GT 3, treatment week 4 and 12 results were: PPV, 84.7% and 75.3%; NPV, 47.8% and 50.0%; OR, 5.09 and 3.05. CONCLUSIONS: The cobas HCV test is highly sensitive, specific, and accurate HCV RNA test for GT 1-6. It demonstrates excellent correlation with the FDA-approved CAP/CTM HCV v2 test. It is useful clinically for detection of active HCV infection in individuals that have had a positive anti-HCV antibody test result and in monitoring treatment response.


Assuntos
Monitoramento de Medicamentos/métodos , Hepatite C/diagnóstico , Técnicas de Diagnóstico Molecular , Genótipo , Hepacivirus/genética , Hepacivirus/isolamento & purificação , Hepatite C/tratamento farmacológico , Anticorpos Anti-Hepatite C/sangue , Hepatite C Crônica/diagnóstico , Hepatite C Crônica/tratamento farmacológico , Humanos , Limite de Detecção , Técnicas de Diagnóstico Molecular/normas , RNA Viral/sangue , RNA Viral/genética , Kit de Reagentes para Diagnóstico , Reação em Cadeia da Polimerase em Tempo Real , Sensibilidade e Especificidade , Carga Viral
15.
Genome Announc ; 5(14)2017 Apr 06.
Artigo em Inglês | MEDLINE | ID: mdl-28385830

RESUMO

We report here paired isogenic Burkholderia pseudomallei genomes obtained from three patients receiving intravenous meropenem for melioidosis treatment, with post-meropenem isolates developing decreased susceptibility. Two genomes were finished, and four were drafted to improved high-quality standard. These genomes will be used to identify meropenem resistance mechanisms in B. pseudomallei.

16.
Curr Biol ; 27(22): 3511-3519.e7, 2017 Nov 20.
Artigo em Inglês | MEDLINE | ID: mdl-29129531

RESUMO

The Aedes aegypti mosquito transmits arboviruses, including dengue, chikungunya, and Zika virus. Understanding the mechanisms underlying mosquito immunity could provide new tools to control arbovirus spread. Insects exploit two different RNAi pathways to combat viral and transposon infection: short interfering RNAs (siRNAs) and PIWI-interacting RNAs (piRNAs) [1, 2]. Endogenous viral elements (EVEs) are sequences from non-retroviral viruses that are inserted into the mosquito genome and can act as templates for the production of piRNAs [3, 4]. EVEs therefore represent a record of past infections and a reservoir of potential immune memory [5]. The large-scale organization of EVEs has been difficult to resolve with short-read sequencing because they tend to integrate into repetitive regions of the genome. To define the diversity, organization, and function of EVEs, we took advantage of the contiguity associated with long-read sequencing to generate a high-quality assembly of the Ae. aegypti-derived Aag2 cell line genome, an important and widely used model system. We show EVEs are acquired through recombination with specific classes of long terminal repeat (LTR) retrotransposons and organize into large loci (>50 kbp) characterized by high LTR density. These EVE-containing loci have increased density of piRNAs compared to similar regions without EVEs. Furthermore, we detected EVE-derived piRNAs consistent with a targeted processing of persistently infecting virus genomes. We propose that comparisons of EVEs across mosquito populations may explain differences in vector competence, and further study of the structure and function of these elements in the genome of mosquitoes may lead to epidemiological interventions.


Assuntos
Imunidade Adaptativa/genética , Aedes/genética , Aedes/imunologia , Animais , Elementos de DNA Transponíveis/genética , Genoma , Mosquitos Vetores/genética , Mosquitos Vetores/imunologia , Interferência de RNA/imunologia , RNA Interferente Pequeno/genética
17.
Therap Adv Gastroenterol ; 10(8): 609-618, 2017 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-28835775

RESUMO

BACKGROUND: HBV DNA is the most important molecular marker in hepatitis B, used to determine treatment indication and monitoring. Most patients require lifelong hepatitis B virus (HBV) management, thus viral load (VL) monitoring may be performed at different laboratories, with different HBV assays, which may result in different VL results. This multicenter study compares the commutability and concordance of results from four different HBV DNA assays: CAP/CTM HBVv2, HPS/CTM HBVv2 and the new cobas 6800/8800 HBV and cobas 4800 HBV assays. METHODS: Across all four assays, HBV limit of detection (LoD) and linearity at lower concentrations were assessed using panels traceable to the World Health Organization international standard, and concordance was investigated at the important medical decision cutoffs 2000 and 20,000 IU/ml, using specimens from HBV-positive patients. RESULTS: The calculated LoD via a probit curve was 2.7 IU/ml for cobas 6800/8800 HBV, 2.8 IU/ml for cobas 4800 HBV, 9.6 IU/ml for CAP/CTM HBVv2, and 6.2 IU/ml for HPS/CTM HBVv2. The average accuracy was comparable between cobas 6800/8800 HBV, cobas 4800 HBV and CAP/CTM HBVv2 (0.04-0.05 log10 IU/ml), while a slightly lower accuracy was documented for HPS/CTM HBVv2 (-0.16 log10 IU/ml). A total of 211-245 clinical samples were used for a pairwise comparison. Mean paired log differences ranged from -0.17 log10 IU/ml to -0.01 log10 IU/ml. Coefficient of determination was over 98% for all pairs with high overall percent agreement at the 2000 and 20,000 IU/ml cutoffs (from 91.7% to 96.3%). In a subset of samples with VL±0.5 log10 to the 2000 and 20,000 IU/ml thresholds, concordance was still 72% and 82%, respectively. CONCLUSIONS: The new cobas 6800/8800 HBV and 4800 HBV assays show high accuracy in samples with low-level viremia and a high concordance with the established HBV tests, CAP/CTM HBVv2 and HPS/CTM HBVv2, at 2000 and 20,000 IU/ml. Thus, all four HBV assays have high commutability and may be used interchangeably in routine clinical practice.

18.
AIDS Res Hum Retroviruses ; 22(3): 289-93, 2006 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-16545016

RESUMO

We analyzed the nonnucleoside reverse transcriptase (RT) inhibitor (NNRTI) susceptibility of 29 subtype A HIV-1 clones isolated from 10 Ugandan women after single-dose nevirapine (NVP) administration. Six clones had no NNRTI resistance-associated mutations ("wild type"), eight had K103N, nine had Y181C, five had G190A, and one had Y181S. Three clones displayed unexpected phenotypic drug susceptibility/resistance based on their RT genotypes. One wild-type clone had reduced susceptibility to NVP, delavirdine (DLV), and efavirenz (EFV), one clone with K103N was susceptible to all three NNRTIs, and one clone with G190A had extreme hypersusceptibility to DLV. Three unusual HIV-1 RT amino acid substitutions may have contributed to the unexpected phenotypes of the clones: I31T, N136S, and N265D. These polymorphisms were rarely detected among 47,900 HIV-1 genotypes from clinical samples of predominantly United States origin. Further studies are needed to define the genetic correlates of antiretroviral drug resistance in nonsubtype B HIV-1.


Assuntos
Fármacos Anti-HIV/farmacologia , Farmacorresistência Viral , HIV-1/classificação , HIV-1/efeitos dos fármacos , Mutação , Inibidores da Transcriptase Reversa/farmacologia , Alcinos , Substituição de Aminoácidos , Benzoxazinas , Células Clonais , Ciclopropanos , Delavirdina/farmacologia , Feminino , Transcriptase Reversa do HIV/genética , Humanos , Nevirapina/farmacologia , Oxazinas/farmacologia , Polimorfismo Genético
19.
AIDS Res Hum Retroviruses ; 22(1): 22-6, 2006 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-16438641

RESUMO

We analyzed the subtypes and genotypic and phenotypic drug susceptibility profiles of 18 HIV-1 isolates from treatment-naive patients in Nigeria. A modified gp41-based heteroduplex mobility assay was used to determine the clade designation based on the envelope gene. The protease and most of the reverse transcriptase regions were cloned into a retroviral expression vector and sequenced. Samples were also analyzed phenotypically using a rapid phenotypic assay (PhenoSense HIV, ViroLogic, Inc.). According to the modified gp41-based heteroduplex mobility assay, the patients were infected with either clade G (17 specimens) or clade A (one specimen) isolates. From phylogenetic analyses of 1212 nucleotides of the polymerase gene, 14 of the 18 isolates were strongly grouped with subtype G reference strains. The remaining four isolates were grouped with the CRF_02_AG clade. Within the protease region, all 18 isolates had mutations/polymorphic substitutions at six locations compared to the HIV-1 NL4-3 reference sequence, two of which have been associated with resistance to protease inhibitors (K20I and M36I). At least half of the isolates had mutations/polymorphic substitutions at an additional five positions in the protease region. Within the reverse transcriptase (RT) region, all 18 isolates showed an E291D mutation/polymorphic substitution. Mutations/polymorphic substitutions were also found in at least half of the isolates at 21 positions. The phenotypic profiles of the viruses correlated well with the observed genotypes. Two isolates showed slightly reduced susceptibility to one or two of the five PIs assessed (ritonavir and ritonavir/nelfinavir) and all 18 viruses were susceptible to all NRTIs and NNRTIs analyzed.


Assuntos
Fármacos Anti-HIV/farmacologia , Farmacorresistência Viral , Protease de HIV/genética , Transcriptase Reversa do HIV/genética , HIV-1/enzimologia , HIV-1/genética , Genótipo , Infecções por HIV , HIV-1/classificação , HIV-1/efeitos dos fármacos , Humanos , Nigéria/epidemiologia , Fenótipo , Filogenia , Inibidores da Transcriptase Reversa
20.
Virus Evol ; 2(2): vew018, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-29492273

RESUMO

The ability to study rapidly evolving viral populations has been constrained by the read length of next-generation sequencing approaches and the sampling depth of single-genome amplification methods. Here, we develop and characterize a method using Pacific Biosciences' Single Molecule, Real-Time (SMRT®) sequencing technology to sequence multiple, intact full-length human immunodeficiency virus-1 env genes amplified from viral RNA populations circulating in blood, and provide computational tools for analyzing and visualizing these data.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA