RESUMO
Since 2010, positron emission tomography/magnetic resonance (PET/MR) has been increasingly used as clinical routine in nuclear medicine departments. One advantage of PET/MR over PET/computed tomography (CT) is the lower dose of ionising radiation delivered to patients. However, data on the radiation dose delivered to staff operating PET/MR compared with the new generation of PET/CT equipment are still lacking. Our aim was to compare the radiation dose to nuclear medicine technologists performing routine PET/MR and PET/CT in the same department. We retrospectively measured the daily radiation dose received by PET technologists over 13 months by collecting individual dosimetry measurements (from electronic personal dosimeters). Data were analysed taking into account the total number of studies performed with each PET modality (PET/MR with Signa 3T, General Electric Healthcare versus PET/CT with Biograph mCT flow, Siemens), the type of exploration (brain versus whole-body PET), the18F activity injected per day and per patient as well as the time spent in contact with patients after tracer injection. Our results show a significantly higher whole-body exposure to technologists for PET/MR compared with PET/CT (10.3 ± 3.5 nSv versus 4.7 ± 1.2 nSv per18F injected MBq, respectively;p< 0.05). This difference was related to prolonged contact with injected patients during patient positioning with the PET/MR device and MR coil placement, especially in whole-body studies. For an equal injected activity, radiation exposure to PET technologists for PET/MR was twice that of PET/CT. To minimise the radiation dose to staff, efforts should be made to optimise patient positioning, even in departments with extensive PET/CT experience.
Assuntos
Medicina Nuclear , Exposição Ocupacional , Fluordesoxiglucose F18 , Humanos , Espectroscopia de Ressonância Magnética , Exposição Ocupacional/análise , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada/métodos , Tomografia por Emissão de Pósitrons , Doses de Radiação , Compostos Radiofarmacêuticos , Estudos Retrospectivos , Tomografia Computadorizada por Raios XRESUMO
Since october 2015, PET/MR has been used extensively for clinical routine in the nuclear medicine department of the Pitié-Salpêtrière Hospital (Paris, France) with a throughput of 11 to 15 patients each day. While many studies have been conducted to investigate dose reduction strategies to patients with hybrid PET/MR devices, no study has focused on staff radiation safety. Knowing that patient positioning within the scanner takes longer in PET/MR than in PET/CT because of the placement of several local MR receive coils, a retrospective study was carried out to measure the radiation doses to nuclear medicine technologists from the patient. The analysis was conducted during one year on 1332 clinical PET/MR studies performed with the Signa PET/MR system (General Electric Healthcare) in our department. The whole-body exposure of the technologist staff was on average for all PET/MR exams10.3 ± 4 nSv per injected MBq of 18 F. When performing brain PET/MR exams only, the whole-body exposure was on average 8.7 ± 2 nSv per injected MBq of 18 F. Brain PET/MR provides lower radiation dose than whole-body examinations for cancer screening due to a lower injected activity (2 vs. 3 MBq kg-1) and shorter patient positioning (5 vs. 15 min). When starting PET/MR in a nuclear medicine department, an important step is to optimise patient positionning within the scanner to minimise radiation dose received by the technical staff from patients.
Assuntos
Imagem Multimodal , Medicina Nuclear , Exposição Ocupacional/análise , Posicionamento do Paciente , Doses de Radiação , Proteção Radiológica/métodos , França , Humanos , Imageamento por Ressonância Magnética , Exposição Ocupacional/prevenção & controle , Tomografia por Emissão de Pósitrons , Compostos Radiofarmacêuticos/administração & dosagem , Estudos RetrospectivosRESUMO
ABSTRACT: Radioembolization using 90 Y is a growing procedure in nuclear medicine for treating hepatocellular carcinoma. Current guidelines suggest postponing liver transplantation or surgical resection for a period of 14 to 30 d after radioembolization to minimize surgeons' exposure to ionizing radiation. In light of a radiation protection incident, we reevaluated the minimum delay required between radioembolization and subsequent liver transplantation. A patient with a hepatocellular carcinoma underwent a liver transplantation 44 h after undergoing radioembolization using 90 Y (860 MBq SIR-Spheres). No specific radioprotection measures were followed during surgery and pathological analysis. We subsequently (1) evaluated the healthcare professionals' exposure to ionizing radiation by conducting dose rate measurements from removed liver tissue and (2) extrapolated the recommended interval to be observed between radioembolization and surgery/transplantation to ensure compliance with the radiation dose limits for worker safety. The surgeons involved in the transplantation procedure experienced the highest radiation exposure, with whole-body doses of 2.4 mSv and extremity doses of 24 mSv. The recommended delay between radioembolization and liver transplantation was 8 d when using SIR-Spheres and 15 d when injecting TheraSphere. This delay can be reduced further when considering the specific 90 Y activity administered during radioembolization. This dosimetric study suggests the feasibility of shortening the delay for liver transplantation/surgery after radioembolization from the 8th or 15th day after using SIR-Spheres or TheraSphere, respectively. This delay can be decreased further when adjusted to the administrated activity while upholding radiation protection standards for healthcare professionals.