Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Surg Oncol ; 125(3): 361-368, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34724205

RESUMO

BACKGROUND AND OBJECTIVES: Breast-conserving surgery (BCS) is followed by reoperations in approximately 25%. Reoperations lead to an increased risk of infection and wound healing problems as well as a worse cosmetic outcome. Several technical approaches for an intraoperative margin assessment to decrease the reoperation rate are under evaluation, some of them are still experimental. METHODS: A prospective single-arm post-marketing study with 60 patients undergoing BCS for ductal carcinoma in situ (DCIS) and invasive breast cancer was conducted. The specimen was intraoperatively examined by the ClearSight™ system, a mobile magnetic resonance imaging system that is based on a diffusion-weighted imaging protocol. However, the results were blinded to the surgeon. RESULTS: The ClearSight™ system was performed for both ductal and lobular breast cancer and DCIS, with a sensitivity of 0.80 (95% confidence interval [CI]: 0.44-0.96) and a specificity of 0.84 (95% CI 0.72-0.92), with an overall diagnostic accuracy of 80%. CONCLUSION: Had the ClearSight™ been known to the surgeon intraoperatively, the reoperation rate would have been reduced by 83% for invasive carcinoma, from 10% to 2%, and 50% for DCIS, from 30% to 15% reoperations. A trial designed to examine the impact on reoperation rates is currently ongoing.


Assuntos
Neoplasias da Mama/cirurgia , Carcinoma Ductal de Mama/cirurgia , Carcinoma Intraductal não Infiltrante/cirurgia , Cuidados Intraoperatórios , Imageamento por Ressonância Magnética , Margens de Excisão , Adulto , Idoso , Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/patologia , Carcinoma Ductal de Mama/diagnóstico por imagem , Carcinoma Ductal de Mama/patologia , Carcinoma Intraductal não Infiltrante/diagnóstico por imagem , Carcinoma Intraductal não Infiltrante/patologia , Feminino , Humanos , Mastectomia Segmentar , Pessoa de Meia-Idade , Vigilância de Produtos Comercializados , Estudos Prospectivos , Sensibilidade e Especificidade
2.
J Surg Oncol ; 114(1): 22-6, 2016 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-27080211

RESUMO

BACKGROUND AND OBJECTIVES: One of the major unmet needs in Breast Conserving Surgery (BCS) is a rapid and accurate margin assessment of the lumpectomy specimen. This study evaluates the ability of a novel MRI system (prototype of the ClearSight™ system; Clear-Cut Medical Ltd., Rehovot, Israel) to distinguish malignant and non-malignant tissues in freshly excised breast specimen by comparing MR measurements to histopathology results. METHODS: Seventy-seven samples were obtained from 22 patients undergoing BCS enrolled in the study. A T2* (T2 Star) value in milliseconds (ms) was calculated for each sample and correlated with histopathology results. RESULTS: Of the 77 samples, 35 samples were classified by histopathology as malignant and 42 as non-malignant. T2* values were significantly higher in malignant samples compared to non-malignant samples (15.3 ± 2.72 ms and 10.6 ± 1.47 ms, respectively [P < 0.00001]). Analysis for a determined cutoff of 11.7 ms revealed 91% sensitivity, 93% specificity, and 92% accuracy. ROC curve analysis yielded AUC of 0.97. CONCLUSIONS: This study demonstrates that the system is sensitive and specific in differentiating malignant and non-malignant tissues in freshly excised breast specimen. The system has the potential to be used for breast specimen margin assessment during BCS, with the goal of decreasing the need for re-operation. J. Surg. Oncol. 2016;114:22-26. © 2016 Wiley Periodicals, Inc.


Assuntos
Neoplasias da Mama/diagnóstico por imagem , Neoplasias da Mama/cirurgia , Imageamento por Ressonância Magnética , Margens de Excisão , Mastectomia Segmentar/métodos , Adulto , Idoso , Neoplasias da Mama/patologia , Feminino , Humanos , Período Intraoperatório , Imageamento por Ressonância Magnética/instrumentação , Imageamento por Ressonância Magnética/métodos , Pessoa de Meia-Idade , Avaliação de Resultados em Cuidados de Saúde , Curva ROC , Sensibilidade e Especificidade
3.
J Tissue Eng Regen Med ; 7(5): 401-12, 2013 May.
Artigo em Inglês | MEDLINE | ID: mdl-22411912

RESUMO

Use of naturally derived materials is becoming widespread in the biomedical field. Soy protein has advantages over the various types of natural proteins employed for biomedical applications, due to its low price, non-animal origin and relatively long storage time and stability. In the current study, soy protein isolate (SPI) was investigated as a matrix for wound-dressing applications. The antibiotic drug gentamicin was incorporated into the matrix for local controlled release and thus continuous bactericidal effect. Homogeneous high-quality films were cast from aqueous solutions and tested for the effects of gentamicin release on bacterial inhibition. The cytotoxicity and in vitro biocompatibility of these films were also examined. The gentamicin release profiles exhibited a moderate burst effect followed by a decreasing release rate, which was maintained for at least 4 weeks, thus enabling a suitable bacterial inhibition effect. The materials released from the films during an indirect cytotoxicity test were found to be safe, except for a slight inhibitory effect in the presence of high concentrations of glycerol. The biocompatibility test showed confluent cell cultures in close proximity to the SPI films. It is clear that these new antibiotic-eluting SPI films exhibit a high potential for use as wound dressings.


Assuntos
Antibacterianos/farmacologia , Bactérias/efeitos dos fármacos , Fibroblastos/citologia , Proteínas de Soja/farmacologia , Cicatrização/efeitos dos fármacos , Contagem de Células , Células Cultivadas , Difusão , Fibroblastos/efeitos dos fármacos , Gentamicinas/farmacologia , Humanos , Masculino , Teste de Materiais , Testes de Sensibilidade Microbiana , Estresse Mecânico , Resistência à Tração/efeitos dos fármacos
4.
Acta Biomater ; 8(1): 209-17, 2012 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-21911084

RESUMO

Naturally derived materials are becoming widely used in the biomedical field. Soy protein has advantages over various types of natural proteins employed for biomedical applications due to its low price, non-animal origin and relatively long storage time and stability. In the current study soy protein isolate (SPI) was investigated as a matrix for wound dressing applications. The antibiotic drug gentamicin was incorporated into the matrix for local controlled release and, thus, protection against bacterial infection. Homogeneous yellowish films were cast from aqueous solutions. After cross-linking they combined high tensile strength and Young's modulus with the desired ductility. The plasticizer type, cross-linking agent and method of cross-linking were found to strongly affect the tensile properties of the SPI films. Selected SPI films were tested for relevant physical properties and the gentamicin release profile. The cross-linking method affected the degree of water uptake and the weight loss profile. The water vapor transmission rate of the films was in the desired range for wound dressings (∼2300 g m(-2) day(-1)) and was not affected by the cross-linking method. The gentamicin release profile exhibited a moderate burst effect followed by a decreasing release rate which was maintained for at least 4 weeks. Diffusion was the dominant release mechanism of gentamicin from cross-linked SPI films. Appropriate selection of the process parameters yielded SPI wound dressings with the desired mechanical and physical properties and drug release behavior to protect against bacterial infection. These unique structures are thus potentially useful as burn and ulcer dressings.


Assuntos
Antibacterianos , Bandagens , Preparações de Ação Retardada , Gentamicinas , Proteínas de Soja/química , Animais , Antibacterianos/administração & dosagem , Antibacterianos/química , Queimaduras/terapia , Reagentes de Ligações Cruzadas/química , Preparações de Ação Retardada/administração & dosagem , Preparações de Ação Retardada/química , Módulo de Elasticidade , Gentamicinas/administração & dosagem , Gentamicinas/química , Humanos , Teste de Materiais , Plastificantes/química , Úlcera Cutânea/terapia , Resistência à Tração , Água/química
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA