Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 104
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Periodontal Res ; 2024 Apr 26.
Artigo em Inglês | MEDLINE | ID: mdl-38666373

RESUMO

AIM: This study evaluated the efficacy of quadrantwise subgingival instrumentation (Q-SI) versus one-stage full-mouth subgingival instrumentation (FM-SI) on probing depth and periodontal pathogen reduction over a 6-month follow-up period, as well as whether baseline periodontal pathogens influenced the impact of periodontal treatment protocols on outcomes. METHODS: Patients with periodontitis were randomized to receive Q-SI (n = 43) or FM-SI (n = 45). Patients were instructed and motivated to maintain optimal oral hygiene during the treatment sessions. Clinical (probing pocket depth [PPD], clinical attachment loss [CAL], and bleeding on probing [BOP]) and periodontal pathogens were assessed at baseline and after 30, 90, and 180 days. Total bacterial load and periodontal pathogens were analysed via real-time PCR. RESULTS: At the 6-month follow-up, the median PPD decreased from 4.8 mm (interquartile range [IQR]: 4.3-5.2) to 2.6 mm (IQR: 2.3-2.9) in FM-SI patients and from 4.7 mm (IQR: 4.1-5.2) to 3.2 mm (IQR: 2.4-3.5) in Q-SI patients (p < .001). At 6 months, FM-SI was more effective at reducing the median proportions of Porphyromonas gingivalis (Pg), Aggregatibacter actinocomyctemcomitans, and Tannerella forsythia (Tf) (p < .001 for each value). Multilevel linear regression analysis demonstrated that high baseline PPD (p = .029), Pg (p = .014), and Tf (p < .001) levels and the FM-SI protocol (p < .001) were statistically significant predictors of PPD reduction at 6 months. Furthermore, PPD reduction was significantly greater in the FM-SI group when lower baseline Pg levels were detected. CONCLUSION: The FM-SI was more effective than the Q-SI in reducing the mean PPD and number of periodontal pathogens in periodontitis patients over a 6-month follow-up period. Higher baseline PPD and Pg levels had a negative impact on PPD reduction at 6 months after FM-SI.

2.
J Oral Implantol ; 50(1): 45-49, 2024 Feb 01.
Artigo em Inglês | MEDLINE | ID: mdl-38579112

RESUMO

The stability of implant-abutment joint is fundamental for the long-term success of implant rehabilitation. The screw loosening, fracture, and head deformation are among the most common mechanical complications. Several surface treatments of titanium screws have been proposed to improve their resistance and stability. Diamond-like carbon (DLC) coating of the materials is widely used to increase their wear resistance and durability. The present study aimed to evaluate the effect of carbon fiber coating on the screw head on screw removal torque and screw head stripping. One hundred titanium implant screws were used, 50 without coating (Group 1) and 50 with DLC coating of the screw head (Group 2). Each screw was tightened with a torque of 25 Ncm and unscrewed 10 times. The removal torque was measured with a digital cap torque tester for each loosening. Optical 3d measurement of the screw head surface was performed by a fully automatic machine before and after multiple tightening to investigate surface modifications. The reverse torque values decreased with repeated tightening and loosening cycles in both groups without significant differences (P > .05). Optical measurements of surface dimensions revealed average changes of 0.0357 mm in Group 1 and 0.02312 mm in Group 2, which resulted to be statistically significant (P < .001). The DLC coating of the retention screw head can prevent its distortion and wear, especially after multiple tightening.


Assuntos
Implantes Dentários , Carbono , Titânio , Análise do Estresse Dentário/métodos , Torque , Parafusos Ósseos , Dente Suporte
3.
Medicina (Kaunas) ; 60(5)2024 Apr 30.
Artigo em Inglês | MEDLINE | ID: mdl-38792929

RESUMO

Background and Objectives: The objective of this retrospective controlled study is to compare class II growing patients who underwent treatment with two different functional appliances: the Fraenkel regulator (FR-2), utilized as the control group, and the elastodontic device "Cranium Occluded Postural Multifunctional Harmonizers" (AMCOP), utilized as the test group. Materials and Methods: The study sample consisted of 52 patients with class II division I malocclusion (30 males, 22 females, mean age 8.6 ± 1.4 years) who were treated with the two different types of appliances: Group 1 (n = 27, mean age 8 [7.00, 9.00] years, 12 females, 15 males) received treatment with AMCOP, while Group 2 (n = 25, mean age 9.2 years [8.20, 10.00], 10 females, 15 males) received treatment with FR-2. The mean treatment duration for Group 1 was 28.00 [21.50, 38.00] months, while for Group 2 it was 23.70 [17.80, 27.40] months. Cephalometric analyses were performed on lateral cephalograms taken before treatment (T1) and after treatment (T2). Results: Significant intragroup differences were observed over time in Group 1 for 1^/PP. Similarly, significant intragroup differences were observed over time in Group 2 for SNB, ANB, and IMPA. Conclusions: Both treatment modalities resulted in the correction of class II malocclusion with dentoalveolar compensation, although the treatment duration with AMCOP tended to be longer on average.


Assuntos
Má Oclusão Classe II de Angle , Humanos , Masculino , Feminino , Criança , Estudos Retrospectivos , Má Oclusão Classe II de Angle/terapia , Aparelhos Ortodônticos Funcionais , Aparelhos Ortodônticos Removíveis , Cefalometria/métodos , Resultado do Tratamento
4.
Clin Oral Investig ; 27(11): 6855-6863, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37814162

RESUMO

OBJECTIVES: The present study aims to assess the serum circulating cell-free (cfDNA) concentrations in patients with periodontitis and cardiovascular disease (CVD) and to evaluate the impact of periodontitis on circulating cfDNA levels and the confounding factors that might mediated the possible relationship. MATERIALS AND METHODS: Healthy controls (n=30) and patients with CVD (n=31), periodontitis (n=31), and periodontitis + CVD (n=30) were enrolled in the present study. All subjects underwent regular periodontal examination and blood sampling and cfDNA evaluation. The analysis of the plasma cfDNA concentrations was performed using a dsDNA Assay Kit. RESULTS: In comparison with healthy controls and CVD patients, periodontitis and periodontitis+CVD exhibited significantly higher expression of circulating cfDNA (p<0.05). There was a positive correlation among plasma cfDNA and clinical attachment loss (CAL) (p=0.019), high sensitivity C-reactive protein (hs-CRP) (p=0.027), and periodontal inflamed surface area (PISA) (p=0.003). Furthermore, the multivariate regression analysis evidenced that PISA (p<0.001), hs-CRP (p=0.014), and full-mouth bleeding score (FMBS) (p=0.004) were significant predictors of circulating cfDNA concentrations. CONCLUSIONS: The results of the study highlighted that the periodontitis and periodontitis + CVD group showed higher circulating cfDNA expression in comparison with healthy controls and CVD patients. Moreover, the extent of periodontitis was correlated with the increased cfDNA levels and represented a significant predictor of the increased circulating cfDNA concentrations. CLINICAL RELEVANCE: Unbalanced circulating cfDNA concentrations have been indicated to represent a possible risk of CVD and endothelial dysfunction. Periodontitis and periodontitis + CVD patients showed higher circulating cfDNA expression; moreover, the extent of periodontitis significantly predicted higher circulating cfDNA concentrations, suggesting the potential increased risk of developing CVD in periodontitis patients.


Assuntos
Doenças Cardiovasculares , Ácidos Nucleicos Livres , Periodontite , Humanos , Proteína C-Reativa/análise , Periodontite/complicações , Análise Multivariada
5.
Int J Mol Sci ; 24(4)2023 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-36834613

RESUMO

The aim of the present systematic review is to summarize current knowledge regarding the analysis of biomarkers extracted from peri-implant crevicular fluid (PICF) as predictors of peri-implant bone loss (BL). An electronic search was conducted on three databases, PubMed/MEDLINE, Cochrane Library, and Google Scholar, to find clinical trials published until 1 December 2022 suitable to answer the following focused question: in patients with dental implants, are biomarkers harvested from PICF predictive of peri-implant BL? The initial search yielded a total of 158 entries. After a full-text review and application of the eligibility criteria, the final selection consisted of nine articles. The risk of bias in included studies was assessed using the Joanna Briggs Institute Critical Appraisal tools (JBI). According to the present systematic review, some inflammatory biomarkers harvested from PICF (collagenase-2, collagenase-3, ALP, EA, gelatinase b, NTx, procalcitonin, IL-1ß, and several miRNAs) seem to be correlated with peri-implant BL and may assist in the early diagnosis of pathological BL, that characterizes peri-implantitis. MiRNA expression demonstrated a predictive potential of peri-implant BL that could be useful for host-targeted preventive and therapeutic purposes. PICF sampling may represent a promising, noninvasive, and repeatable form of liquid biopsy in implant dentistry.


Assuntos
Implantes Dentários , MicroRNAs , Peri-Implantite , Humanos , Líquido do Sulco Gengival/metabolismo , Biomarcadores/análise , Peri-Implantite/diagnóstico , Metaloproteinase 8 da Matriz
6.
Int J Mol Sci ; 24(12)2023 Jun 10.
Artigo em Inglês | MEDLINE | ID: mdl-37373135

RESUMO

In the last few decades, circulating cell-free DNA (cfDNA) has been shown to have an important role in cell apoptosis or necrosis, including in the development and evolution of several tumors and inflammatory diseases in humans. In this regard, periodontitis, a chronic inflammatory disease that can induce the destruction of supporting components of the teeth, could represent a chronic inflammatory stimulus linked to a various range of systemic inflammatory diseases. Recently, a possible correlation between periodontal disease and cfDNA has been shown, representing new important diagnostic-therapeutic perspectives. During the development of periodontitis, cfDNA is released in biological fluids such as blood, saliva, urine and other body fluids and represents an important index of inflammation. Due to the possibility of withdrawing some of these liquids in a non-invasive way, cfDNA could be used as a possible biomarker for periodontal disease. In addition, discovering a proportional relationship between cfDNA levels and the severity of periodontitis, expressed through the disease extent, could open the prospect of using cfDNA as a possible therapeutic target. The aim of this article is to report what researchers have discovered in recent years about circulating cfDNA in the development, evolution and therapy of periodontitis. The analyzed literature review shows that cfDNA has considerable potential as a diagnostic, therapeutic biomarker and therapeutic target in periodontal disease; however, further studies are needed for cfDNA to be used in clinical practice.


Assuntos
Ácidos Nucleicos Livres , Neoplasias , Doenças Periodontais , Periodontite , Humanos , Periodontite/diagnóstico , Periodontite/genética , Biomarcadores , Ácidos Nucleicos Livres/genética , Inflamação
7.
BMC Oral Health ; 23(1): 235, 2023 04 21.
Artigo em Inglês | MEDLINE | ID: mdl-37085829

RESUMO

OBJECTIVE: The aim of the present systematic review was to test the hypothesis that the diameter of implants inserted in the posterior area affects implant survival rate, prosthetic survival rate and peri-implant parameters (bleeding on probing (BoP), marginal bone loss (MBL), pocket probing depth (PPD)). MATERIALS AND METHODS: An electronic search of studies published until December 2021 was done on three databases (Pubmed, Scopus, Cochrane) independently by two authors. Clinical trials comparing implant survival rate, BoP, MBL and PPD among narrow diameter implants (NDI: ≥ 3.0 mm to < 3.75 mm) and regular diameter implants (RDI ≥ 3.75 mm to < 5 mm) were included. Data were independently extracted by two reviewers. Risk of bias was evaluated according to the Cochrane risk-of-bias tool for randomized studies and to the Joanna Briggs Institute Critical Appraisal tools for non-randomized ones. A pair-wise meta-analysis was conducted on the included studies. RESULTS: Seven articles were included out of the 4291 identified from the digital research. Overall, a total of 939 implants were inserted (319 NDI, 620 RDI). Only one study was judged at serious risk of bias. No statistically significant difference was found in implant survival rate (risk ratio 1.01 (95% CI [0.98 to 1.04], P = 0.67)) while the difference was significant for BoP (mean difference 2.89 (95% CI [0.30 to 5.48] mm, P = 0.03)) with higher values for NDI. Higher MBL was identified among regular diameter implants (mean difference -0.15 mm (95% CI [-0.32 to 0.01 mm], P = 0.07). No statistically significant differences were identified for prosthetic survival and PPD. CONCLUSIONS: No differences were found in implant survival rate between narrow and regular implants. A higher BoP was identified among narrow implants, but there was no higher bone loss. It is not possible to draw definitive conclusions about the use of narrow-diameter implants in the posterior region.


Assuntos
Perda do Osso Alveolar , Implantes Dentários , Humanos , Taxa de Sobrevida , Implantação Dentária Endóssea , Bases de Dados Factuais
8.
BMC Oral Health ; 23(1): 27, 2023 01 17.
Artigo em Inglês | MEDLINE | ID: mdl-36650477

RESUMO

PURPOSE: Biofilm-free implant surface is ultimate prerequisite for successful soft and bone tissue integration. Objective of the study was to estimate the effects of argon plasma healing abutment pre-treatment (PT) on peri-implant soft-tissue phenotype (PiSP), inflammation, plaque accumulation and the microbiome (PiM) between non-treated (NPT) and treated (PT) abutments following 3-months healing period. The hypothesis was that cell-conductive and antimicrobial properties of PT would yield optimal conditions for soft tissue integration. MATERIAL AND METHODS: Two months following second-phase surgery, microbiological and clinical parameters were assessed around thirty-six healing abutments with two types of microtopography, smooth surface (MACHINED) and ultrathin threaded microsurface (ROUGH). A two level randomization schema was used to achieve equal distribution and abutments were randomly divided into rough and machined groups, and then divided into PT and NPT groups. PiM was assessed using next-generation DNA sequencing. RESULTS: PiM bacterial composition was highly diverse already two months post-implantation, consisting of key-stone pathogens, early and late colonizers, while the mycobiome was less diverse. PT was associated with lower plaque accumulation and inflammation without significant impact on PiSP, while in NPT clinical parameters were increased and associated with periopathogens. NPT mostly harbored late colonizers, while PT exerted higher abundance of early colonizers suggesting less advanced plaque formation. Interaction analysis in PT demonstrated S. mitis co-occurrence with pro-healthy Rothia dentocariosa and co-exclusion with Parvimonas micra, Porphyromonas endodontalis and Prevotella oris. PiSP parameters were generally similar between the groups, but significant association between PiM and keratinized mucosa width was observed in both groups, with remarkably more expressed diversity in NPT compared to PT. PT resulted in significantly lower BOP and PI around rough and machined abutments, respectively, without specific effect on PiM and PiSP. CONCLUSIONS: PT contributed to significantly the less advanced biofilm accumulation and inflammation without specific effects on PiSP.


Assuntos
Implantes Dentários , Placa Dentária , Microbiota , Gases em Plasma , Humanos , Argônio , Implantação Dentária Endóssea , Planejamento de Prótese Dentária , Inflamação , Titânio
9.
Clin Oral Investig ; 26(7): 4701-4714, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35556173

RESUMO

OBJECTIVES: The detrimental effect of tobacco smoking on periodontal health is well known, while the effect of electronic cigarette on periodontal parameters has been less investigated. The aim of the present systematic review was to compare periodontal indices in three categories of patients: traditional cigarette smokers (TS), e-cigarette smokers (ES), and non-smokers (NS). MATERIALS AND METHODS: An electronic search was conducted for studies published until December 2021 on MEDLINE (PubMed), ISI Web of Science, and Scopus. A hand search was additionally conducted. Clinical observational and cross-sectional trials investigating periodontal indices among tobacco smokers (TS), electronic cigarette smokers (ES) and non-smokers (NS) were included and selected by 2 independent reviewers. Data on probing depth (PD), plaque index (PI), and bleeding on probing (BOP) were collected. The risk of bias was evaluated according to the NIH quality assessment tool and a network meta-analysis (NMA) was undertaken. RESULTS: Five relevant studies, from 707 identified, were included. Overall, 512 patients were included, of them 170 were NS, 176 were TS, and 166 were ES. A significant difference in the comparison among TS vs NS: effect size (ES) = 3.297 (95%CI: [2.142-4.454], p = 0.001) and TS and ES ES = 2.507 (95%CI: [1.351-3.663], p = 0.001) was identified for PD. A significant difference in the comparison among TS and NS, ES = 21.34 (95%CI: [13.41-29.27], p = 0.001) and between TS and ES ES = 15.67 (95%CI: [7.73-23.62], p = 0.001) was identified for PI. The analysis of BOP values shows a significant difference in the comparison among ES and NS: ES = - 16.22 (95%CI: [- 22.85 to - 9.59], p < 0.001) and between TS and NS: ES = - 14.47 (95%CI: [- 21.103 to - 7.848], p < 0.001). Based on the SUCRA ranking, NS showed the most favorable outcome for PD and PI, followed by ES. Tobacco smokers were clearly in the last position. Dealing with BoP ES showed the most favorable outcome, followed by TS. NS were in the last position. CONCLUSIONS: Periodontal parameters were similar among NS and ES, while TS presented the worst indices. BoP was reduced both in ES and in TS. CLINICAL RELEVANCE: Results of the present review suggest a reduced effect on periodontal tissue of e-cig smoking compared to traditional cigarettes, despite recent studies proved that e-cig smoking increases oxidative stress, inflammatory responses, change in pulmonary cellular behavior, and stimulates DNA injury.


Assuntos
Sistemas Eletrônicos de Liberação de Nicotina , Produtos do Tabaco , Estudos Transversais , Humanos , Metanálise em Rede , não Fumantes , Índice Periodontal , Fumantes , Nicotiana
10.
Clin Oral Investig ; 26(1): 13-39, 2022 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-34669038

RESUMO

BACKGROUND: Alveolar ridge preservation (ARP) is a proactive treatment option aiming at attenuating post-extraction hard and soft tissue dimensional changes. A high number of different types of biomaterials have been utilized during ARP to seal the socket, but their effectiveness in terms of soft tissue outcomes has rarely been investigated and compared in the literature. OBJECTIVE: To evaluate the efficacy of different types of membranes and graft materials in terms of soft tissue outcomes (keratinized tissue width changes, vertical buccal height, and horizontal changes) after ARP, and to assign relative rankings based on their performance. MATERIALS AND METHODS: The manuscript represents the proceedings of a consensus conference of the Italian Society of Osseointegration (IAO). PUBMED (Medline), SCOPUS, Embase, and Cochrane Oral Health's Information Specialist were utilized to conduct the search up to 06 April 2021. English language restrictions were placed and no limitations were set on publication date. Randomized controlled trials that report ARP procedures using different sealing materials, assessing soft tissue as a primary or secondary outcome, with at least 6-week follow-up were included. Network meta-analysis (NMA) was performed using mean, standard deviation, sample size, bias, and follow-up duration for all included studies. Network geometry, contribution plots, inconsistency plots, predictive and confidence interval plots, SUCRA (surface under the cumulative ranking curve) rankings, and multidimensional (MDS) ranking plots were constructed. RESULTS: A total of 11 studies were included for NMA. Overall, the level of bias for included studies was moderate. Crosslinked collagen membranes (SUCRA rank 81.8%) performed best in vertical buccal height (VBH), autogenous soft tissue grafts (SUCRA rank 89.1%) in horizontal width change (HWch), and control (SUCRA rank 85.8%) in keratinized mucosa thickness (KMT). CONCLUSIONS: NMA confirmed that the use of crosslinked collagen membranes and autogenous soft tissue grafts represented the best choices for sealing sockets during ARP in terms of minimizing post-extraction soft tissue dimensional shrinkage. CLINICAL RELEVANCE: Grafting materials demonstrated statistically significantly better performances in terms of soft tissue thickness and vertical buccal height changes, when covered with crosslinked collagen membranes. Instead, soft tissue grafts performed better in horizontal width changes. Non-crosslinked membranes and other materials or combinations presented slightly inferior outcomes.


Assuntos
Perda do Osso Alveolar , Aumento do Rebordo Alveolar , Processo Alveolar/cirurgia , Materiais Biocompatíveis , Colágeno , Humanos , Metanálise em Rede , Extração Dentária , Alvéolo Dental/cirurgia
11.
Clin Oral Investig ; 26(2): 1137-1154, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34825280

RESUMO

AIM: By means of a systematic review and network meta-analysis, this study aims to answer the following questions: (a) does the placement of a biomaterial over an extraction socket lead to better outcomes in terms of horizontal and vertical alveolar dimensional changes and percentage of new bone formation than healing without coverage? And (b) which biomaterial(s) provide(s) the better outcomes? MATERIALS AND METHODS: Parallel and split-mouth randomized controlled trials treating ≥ 10 patients were included in this analysis. Studies were identified with MEDLINE (PubMed), Embase, Cochrane Central Register of Controlled Trials, and Scopus. Primary outcomes were preservation of horizontal and vertical alveolar dimension and new bone formation inside the socket. Both pairwise and network meta-analysis (NMA) were undertaken to obtain estimates for primary outcomes. For NMA, prediction intervals were calculated to estimate clinical efficacy, and SUCRA was used to rank the materials based on their performance; multidimensional ranking was used to rank treatments based on dissimilarity. The manuscript represents the proceedings of a consensus conference of the Italian Society of Osseointegration (IAO). RESULTS: Twelve trials were included in the qualitative and quantitative analysis: 312 sites were evaluated. Autologous soft tissue grafts were associated with better horizontal changes compared to resorbable membranes. A statistically significant difference in favor of resorbable membranes, when compared to no membrane, was found, with no statistically significant heterogeneity. For the comparison between crosslinked and non-crosslinked membranes, a statistically significant difference was found in favor of the latter and confirmed by histomorphometric NMA analysis. Given the relatively high heterogeneity detected in terms of treatment approaches, materials, and outcome assessment, the findings of the NMA must be interpreted cautiously. CONCLUSIONS: Coverage of the healing site is associated with superior results compared to no coverage, but no specific sealing technique and/or biomaterial provides better results than others. RCTs with larger sample sizes are needed to better elucidate the trends emerged from the present analysis. CLINICAL RELEVANCE: Autologous soft tissue grafts and membranes covering graft materials in post-extraction sites were proved to allow lower hard tissue shrinkage compared to the absence of coverage material with sealing effect. Histomorphometric analyses showed that non-crosslinked membranes provide improved hard tissue regeneration when compared to crosslinked ones.


Assuntos
Aumento do Rebordo Alveolar , Materiais Biocompatíveis , Assistência Odontológica , Humanos , Metanálise em Rede , Ensaios Clínicos Controlados Aleatórios como Assunto , Extração Dentária , Alvéolo Dental/cirurgia , Resultado do Tratamento , Cicatrização
12.
J Prosthet Dent ; 128(5): 936-941, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-33715833

RESUMO

STATEMENT OF PROBLEM: Limited information is available on the differences between tissue-level implants with an ultrathin threaded microsurface conical transmucosal portion and bone-level implants rehabilitated with conical custom abutments. PURPOSE: The purpose of this retrospective study was to assess the outcomes of crowns designed as per the biologically oriented preparation technique (BOPT) cemented on conical titanium abutments on tissue-level and bone-level implants. MATERIAL AND METHODS: Patients consecutively rehabilitated with a delayed loading protocol with anterior implant-supported single crowns with a feather-edge margin, in function for at least 4 years, were recruited and divided into 2 groups based on the implant type they had received: tissue-level implants with a conical transmucosal portion or bone-level implants rehabilitated with a conical abutment by following the platform switching concept. Bone resorption, pink esthetic score (PES), and white esthetic score (WES) were collected and analyzed. The nonparametric Mann-Whitney test was performed to analyze all parameters (α=.05 for all tests). RESULTS: A total of 43 participants (48 implants) were included in the present study. The mean follow-up period was 4.5 years (range 52-64 months). A statistically significant difference (P=.004) was found in the mean ±standard deviation bone resorption between tissue-level implants (0.38 ±0.46 mm) and bone-level implants (0.83 ±0.58 mm). Higher values for both PES and WES were obtained in the tissue-level implant group. CONCLUSIONS: Within the limitations of the present retrospective study, tissue-level implants with a conical transmucosal portion seem to provide a suitable alternative to bone-level implants in the anterior area.


Assuntos
Reabsorção Óssea , Implantes Dentários para Um Único Dente , Implantes Dentários , Humanos , Estudos Retrospectivos , Estética Dentária , Coroas , Resultado do Tratamento , Prótese Dentária Fixada por Implante , Dente Suporte
13.
Clin Oral Implants Res ; 32(8): 928-940, 2021 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-34036644

RESUMO

OBJECTIVE: To evaluate whether abutment surface and surface bio-activation have an effect on soft tissue morphogenesis. MATERIALS AND METHODS: 36 patients (36 implants) were included. Abutments were randomly divided into 4 groups (n = 9): Smooth Surface-MAChined (MAC), Ultrathin Threaded Microsurface (UTM), MAC Plasma of Argon activated (Plasma-MAC), and UTM Plasma of Argon activated (Plasma-UTM). After 2 months of healing, soft tissue samples were collected and prepared for histological analysis. The margin of the peri-implant mucosa (PM), the apical extension of the barrier epithelium (aJE), and the apical location of the abutment (AM) were identified. Significances of differences among groups were tested by means of the Kruskal-Wallis test and between pairs of results by means of the Mann-Whitney test. RESULTS: The mean (SD) vertical dimension of the mucosa was 2.5mm (1.0), including a connective tissue portion (CTP) of 0.8mm (0.8) in the MAC group; 3.6mm (0.2) with a CTP of 1.6mm (0.4) in the Plasma-MAC group; 3.2mm (1.0), with a CPT of 0.5mm (0.6) in the UTM; and 3.3mm (0.8), with a CPT of 0.9mm (0.7) in the Plasma-UTM group. Statistically significant differences were observed in the aJE-AM height and PM-aJE profile among the four experimental groups (p = .042 and p = .039, respectively). The Mann-Whitney test indicated differences between the Plasma-abutments and the untreated abutments both for PM-AM (p = .025) and AjE-AM (p = .021). The differences appeared more evident when the preoperative soft tissue thickness was ≤2mm. CONCLUSIONS: Within its limits, the study demonstrated a favorable effect of the plasma treatment on the connective tissue portion tissues. Plasma-MAC group highlighted the best performance. This behavior appeared strictly correlated with the soft tissue thickness.


Assuntos
Implantes Dentários , Dente , Argônio , Tecido Conjuntivo , Dente Suporte , Implantação Dentária Endóssea , Humanos , Titânio
14.
J Prosthet Dent ; 125(3): 426-436, 2021 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-32197823

RESUMO

STATEMENT OF PROBLEM: How the properties of the implant-abutment unit may affect the peri-implant soft-tissue seal, whose stability is considered key to safeguarding the implant from bacterial contamination and preserve peri-implant health conditions, is unclear. PURPOSE: The purpose of this systematic review and meta-analysis of animal studies was to investigate whether material and surface properties of transmucosal implant components can influence the peri-implant soft-tissue adhesion at a histological level. MATERIAL AND METHODS: An electronic and hand search was conducted until August 2019. Histological animal studies comparing soft-tissue response to abutment or transmucosal collar with different materials and/or surface characteristics were selected by 2 independent reviewers. Risk of bias in individual studies was evaluated. Histomorphometric data on the dimension of the peri-implant attachment were recorded, and a quantitative synthesis by a meta-analysis was performed. Risk of bias in individual studies was evaluated in accordance with the Systematic Review Centre for Laboratory Animal Experimentation Risk of Bias tool. RESULTS: Eighteen relevant studies out of 1187 were identified, none with a low risk of bias for all domains. Data from only 4 studies could be meta-analyzed. Comparable results in terms of peri-implant attachment dimensions between test and control groups were found, except for a significantly higher apical junctional epithelium to coronal bone to implant (ajE-CBI) distance for chemically modified acid-etched compared with titanium machined surfaces. Non-meta-analyzable and/or qualitative results highlighted some improved properties also for microgrooved and oxidized surfaces. CONCLUSIONS: Limited data from animal studies suggest that some characteristics of the transmucosal implant components may affect peri-implant soft-tissue adhesion and stabilization but do not allow definitive conclusions. Future research should improve study design to increase the availability of comparable and suitable data on this topic.


Assuntos
Implantes Dentários , Dente , Animais , Dente Suporte , Implantação Dentária Endóssea , Inserção Epitelial , Titânio
15.
Clin Oral Investig ; 24(3): 1113-1124, 2020 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-31955269

RESUMO

OBJECTIVES: To evaluate the effect of various titanium abutment modifications on the behaviour of peri-implant soft tissue healing, inflammation and maintenance. MATERIAL AND METHODS: An electronic database research until 30 April 2019 was performed. A meta-analysis (MA) for each outcome parameter was performed by using the random-effects models with the DerSimonian-Laird estimator. RESULTS: Ten studies were included in the present review. Four studies with a long follow-up (5-6 years) reported the outcomes in a heterogeneous way and were suitable for MA. Six studies (4 RCT, 2 CCT) including 118 patients and 182 implants dealing with a modified healing abutment surface and short follow-up were selected for MA. The MA for PI and BoP as outcome showed no significant differences between surfaces (PI: P = 0.091; BoP: P = 0.099). The MA for PD as outcome showed no significant differences between surfaces (P = 0.488). No statistical significance was found by evaluating each mixed-effects model for potential moderators (type of study, study design, number of implants, follow-up length). The other four studies with a longer follow-up (5-6 years) reported contradictory results depending on the surface treatment investigated. CONCLUSIONS: Within their limits, the present findings suggest that peri-implant soft tissue may not be affected by the surface treatment of titanium abutments on the short term. Contrasting results are reported in longer follow-up periods depending on the technique used to modify the abutment. CLINICAL RELEVANCE: Clinicians should carefully evaluate the use of a modified titanium surface in their practice. Even if no differences in terms of inflammation are present at short term, these findings need to be validated in long-term studies.


Assuntos
Dente Suporte , Implantes Dentários , Titânio , Humanos
16.
J Prosthet Dent ; 123(2): 246-251, 2020 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-31227242

RESUMO

STATEMENT OF PROBLEM: Whether increasing the space for peri-implant soft tissues by using implant systems with conical or convergent transmucosal components would improve tissue stability and esthetics is unclear. PURPOSE: The purpose of this prospective clinical study was to evaluate the clinical and esthetic outcomes of using tissue-level implants with a convergent collar in the esthetic zone that had been rehabilitated following the biological oriented preparation technique (BOPT) approach after a 3-year follow-up period. MATERIAL AND METHODS: Sixteen participants with at least 1 nonrestorable tooth in the maxillary anterior region or with congenitally missing maxillary lateral incisors were enrolled, and tissue-level implants with a convergent collar were inserted 3 months after extraction. The implants were restored with cemented single crowns designed according to the BOPT protocol. Bone resorption and the pink esthetic score were evaluated over a 3-year period. RESULTS: Fifteen participants (mean age: 54.6 years) were evaluated over the 3-year period (total: 16 implants). One participant with 1 implant relocated dropped out of the study. The 3-year implant cumulative survival rate was 100%. The mean ±standard deviation bone-level change was 0.071 ±0.11 mm. The mean pink esthetic score was 8.5 ±1.59, range 4-10. CONCLUSIONS: The use of the BOPT protocol to restore tissue-level implants with a convergent collar achieved good esthetic results and maintained stable soft and hard peri-implant tissues.


Assuntos
Implantes Dentários para Um Único Dente , Implantes Dentários , Coroas , Estética Dentária , Humanos , Maxila , Pessoa de Meia-Idade , Estudos Prospectivos , Resultado do Tratamento
17.
J Oral Implantol ; 46(6): 540-549, 2020 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-33494102

RESUMO

The aim of this study was to assess oral health-related quality of life (OHRQoL) of patients before, during, and after completion of implant-supported full-arch immediate loading rehabilitation according to the Columbus Bridge Protocol. Twenty-five patients with compromised dentition were rehabilitated according to the Columbus Bridge Protocol and were assessed for OHRQoL using 4 questionnaires specifically designed for this study and inspired by the Oral Health Impact Profile questionnaire. Patients assessed themselves before surgery, during the healing period (1 week and 2 months after surgery), and after definitive prosthodontic treatment (4 months after surgery). The questionnaires specifically investigated patients' pain, comfort, home oral hygiene habits, satisfaction related to esthetics, masticatory ability, phonetics and general satisfaction with the treatment. Patients reported an improvement of OHRQoL after full-arch immediate-loading rehabilitation. A statistically significant improvement in esthetics and chewing ability was found. After 4 months 92% of the patients did not feel tense about their smile, 96% did not indicate problems relating to other people or smiling, and 92% did not have difficulty eating some foods. Phonetics were a critical issue, especially in the intermediate phase of healing. One week after surgery, the percentage of patients who were very satisfied with phonetics slightly decreased from 48% to 36%. The assessment of patients' OHRQoL related to full-arch immediate-loading implant therapy exhibited a significant improvement in quality of life. The questionnaires herein presented could be an effective tool to evaluate patients' reaction to oral rehabilitation.


Assuntos
Prótese Dentária Fixada por Implante , Qualidade de Vida , Estética Dentária , Humanos , Mastigação , Saúde Bucal , Satisfação do Paciente , Inquéritos e Questionários
18.
Implant Dent ; 28(5): 472-477, 2019 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-31232716

RESUMO

OBJECTIVES: The aim was to investigate the in vivo efficacy of a cancellous particulate allograft bone in the regeneration of postextractive atrophic sites. MATERIAL AND METHODS: Ten patients were selected, and after a minimally invasive extraction of the teeth (T0), a cone beam computed tomography was performed (T1). Seven days after extraction, Puros cancellous particulate homologous graft was inserted into the elected sites together with a membrane (T2). After 4 months, a cone beam computed tomography of the sites was performed (T3). After 5 months, samples of the regenerated sites were taken contextually to implant insertion (T4). The samples were histologically and histomorphometrically analyzed. Intraoral periapical radiographs were accomplished at T4 and at the 6-year follow-up appointment (T5). RESULTS: The mean vertical bone augmentation was of 4.1 mm in the lower jaw and of 3.35 mm in the maxilla at T3 appointment. The mean horizontal bone augmentation in the lower jaw was 2.02 and 2.15 mm in the maxilla. At T4, the mean total bone was 60.01% and the mature bone was 98.41. At the 6-year follow-up visit, the mean periimplant bone resorption was 0.14 mm (range 0-0.5 mm). CONCLUSIONS: Cancellous particulate allograft bone demonstrated excellent bone regeneration behavior both in terms of quantity and quality, and stable results over a 6-year period. CLINICAL RELEVANCE: Cancellous allograft bone can be successfully used to regenerate atrophic sites.


Assuntos
Aumento do Rebordo Alveolar , Transplante Ósseo , Implantação Dentária Endóssea , Seguimentos , Humanos , Maxila , Estudos Retrospectivos , Resultado do Tratamento
19.
Clin Oral Investig ; 22(3): 1253-1262, 2018 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-28965251

RESUMO

OBJECTIVES: The objective of this study was to evaluate the accuracy of different impression techniques on multiple implants. MATERIAL AND METHODS: A master cast simulating a jaw with four implants was used. Eight impression techniques were tested: open tray-polyether#1, open tray plus splint of impression copings with acrylic resin-polyether#1, closed tray-polyether#1, open tray-polyether#2, open tray-splint-polyether#2, closed tray-polyether#2, open tray-impression plaster, and digital impression (DI). Five impressions of the master cast were taken with each traditional impression (TI) technique, pouring 35 sample casts. Three different clinicians took 5 DI each (n = 15). A three-dimensional coordinate measurement machine (CMM) was used to measure implant angulation and inter-implant distances on TI casts. TI data and DI Standard Tessellation Language datasets were compared with the master cast. The best and the worst impressions made with TI and DI were selected to fabricate four milled titanium frameworks. Passive fit was evaluated through Sheffield test, screwing each framework on the master cast. Gaps between framework-implant analogs were measured through a stereomicroscope (×40 magnification). RESULTS: Statistically significant differences in accuracy were found comparing the different impression techniques by CMM (p < 0.01). DI performed the best, while TI techniques revealed a greater variability in the results. Sheffield test revealed a mean gap of 0.022 ± 0.023 mm (the best TI), 0.063 ± 0.059 mm (the worst TI), 0.015 ± 0.011 mm (the best DI), and 0.019 ± 0.015 mm (the worst DI). CONCLUSIONS: Within the limits of this in vitro study, the digital impression showed better accuracy compared to conventional impressioning. CLINICAL RELEVANCE: The digital impression might offer a viable alternative to traditional impressions for fabrication of full-arch implant-supported prostheses with satisfactory passive fit.


Assuntos
Implantes Dentários , Materiais para Moldagem Odontológica/química , Técnica de Moldagem Odontológica , Planejamento de Prótese Dentária , Prótese Dentária Fixada por Implante , Humanos , Técnicas In Vitro , Modelos Dentários , Gravação em Vídeo
20.
Angew Chem Int Ed Engl ; 56(19): 5322-5326, 2017 05 02.
Artigo em Inglês | MEDLINE | ID: mdl-28378388

RESUMO

We report a multi-component asymmetric Brønsted acid-catalyzed aza-Darzens reaction which is not limited to specific aromatic or heterocyclic aldehydes. Incorporating alkyl diazoacetates and, important for high ee's, ortho-tert-butoxyaniline our optimized reaction (i.e. solvent, temperature and catalyst study) affords excellent yields (61-98 %) and mostly >90 % optically active cis-aziridines. (+)-Chloramphenicol was generated in 4 steps from commercial starting materials. A tentative mechanism is outlined.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA