Kidney Int ; 99(6): 1470-1477, 2021 06.
Artigo em Inglês | MEDLINE | ID: mdl-33774082

RESUMO

Patients with end stage kidney disease receiving in-center hemodialysis (ICHD) have had high rates of SARS-CoV-2 infection. Following infection, patients receiving ICHD frequently develop circulating antibodies to SARS-CoV-2, even with asymptomatic infection. Here, we investigated the durability and functionality of the immune responses to SARS-CoV-2 infection in patients receiving ICHD. Three hundred and fifty-six such patients were longitudinally screened for SARS-CoV-2 antibodies and underwent routine PCR-testing for symptomatic and asymptomatic infection. Patients were regularly screened for nucleocapsid protein (anti-NP) and receptor binding domain (anti-RBD) antibodies, and those who became seronegative at six months were screened for SARS-CoV-2 specific T-cell responses. One hundred and twenty-nine (36.2%) patients had detectable antibody to anti-NP at time zero, of whom 127 also had detectable anti-RBD. Significantly, at six months, 71/111 (64.0%) and 99/116 (85.3%) remained anti-NP and anti-RBD seropositive, respectively. For patients who retained antibody, both anti-NP and anti-RBD levels were reduced significantly after six months. Eleven patients who were anti-NP seropositive at time zero, had no detectable antibody at six months; of whom eight were found to have SARS-CoV-2 antigen specific T cell responses. Independent of antibody status at six months, patients with baseline positive SARS-CoV-2 serology were significantly less likely to have PCR confirmed infection over the following six months. Thus, patients receiving ICHD mount durable immune responses six months post SARS-CoV-2 infection, with fewer than 3% of patients showing no evidence of humoral or cellular immunity.


Assuntos
Anticorpos Antivirais/análise , COVID-19/imunologia , Falência Renal Crônica/terapia , Diálise Renal/efeitos adversos , SARS-CoV-2/imunologia , Teste para COVID-19 , Feminino , Humanos , Imunidade , Masculino , Pandemias , Reação em Cadeia da Polimerase , Reinfecção , SARS-CoV-2/isolamento & purificação , Testes Sorológicos/métodos
3.
J Infect ; 86(3): 245-247, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36773896

RESUMO

OBJECTIVES: HTLV-1 is predominantly a sexually-transmitted infection but testing is not mentioned in HIV-PrEP guidelines. We ascertained HTLV-1/HTLV-2 seroprevalence amongst HIV-PrEP users in England. METHODS: An unlinked anonymous seroprevalence study. RESULTS: Amongst 2015 HIV-PrEP users, 95% were men, 76% of white ethnicity and 83% had been born in Europe. There were no HTLV-1/HTLV-2 seropositive cases (95% confidence interval 0% - 0.18%). CONCLUSIONS: There were no HTLV positive cases, likely reflecting the demographic of mostly white and European-born individuals. Similar studies are needed worldwide to inform public health recommendations for HIV-PrEP using populations, particularly in HTLV-endemic settings.


Assuntos
Infecções por HIV , Profilaxia Pré-Exposição , Infecções Sexualmente Transmissíveis , Humanos , Masculino , Infecções por HIV/epidemiologia , Infecções por HIV/prevenção & controle , Estudos Soroepidemiológicos , Inglaterra/epidemiologia , Homossexualidade Masculina
4.
Lancet Reg Health Eur ; 21: 100478, 2022 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-36105885

RESUMO

Background: People with end-stage kidney disease, including people on haemodialysis, are susceptible to greater COVID-19 related morbidity and mortality. This study compares the immunogenicity and clinical effectiveness of BNT162B2 versus ChAdOx1 in haemodialysis patients. Methods: In this observational cohort study, 1021 patients were followed-up from time of vaccination until December 2021. All patients underwent weekly RT-PCR screening. Patients were assessed for nucleocapsid(anti-NP) and spike(anti-S) antibodies at timepoints after second(V2) and third(V3) vaccinations. 191 patients were investigated for T-cell responses. Vaccine effectiveness (VE) for prevention of infection, hospitalisation and mortality was evaluated using the formula VE=(1-adjustedHR)x100. Findings: 45.7% (467/1021) had evidence of prior infection. There was no difference in the proportion of infection-naïve patients who seroconverted by vaccine type, but median anti-S antibody titres were higher post-BNT162b2 compared with ChAdOx1; 462(152-1171) and 78(20-213) BAU/ml respectively, p<0.001.  Concomitant immunosuppressant use was a risk factor for non-response, OR 0.12[95% CI 0.05-0.25] p<0.001.  Post-V3 (all BNT162b2), median anti-S antibody titres remained higher in those receiving BNT162b2 versus ChAdOx1 as primary doses; 2756(187-1246) and 1250(439-2635) BAU/ml respectively, p=0.003.Anti-S antibodies waned over time. Hierarchical levels of anti-S post-V2 predicted risk of infection; patients with no/low anti-S being at highest risk. VE for preventing infection, hospitalisation and death was 53% (95% CI 6-75), 77% (95% CI 30-92) and 93% (95% CI 59-99) respectively, with no difference seen by vaccine type. Interpretation: Serum anti-S concentrations predict risk of breakthrough infection. Anti-S responses vary dependent upon clinical features, infection history and vaccine type. Monitoring of serological responses may enable individualised approaches to vaccine boosters in at risk populations. Funding: National Institute for Health Research (NIHR) Biomedical Research Centre based at Imperial College Healthcare NHS Trust and Imperial College London.

5.
EClinicalMedicine ; 53: 101642, 2022 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-36105874

RESUMO

Background: Solid organ transplant recipients have attenuated immune responses to SARS-CoV-2 vaccines. In this study, we report on immune responses to 3rd- (V3) and 4th- (V4) doses of heterologous and homologous vaccines in a kidney transplant population. Methods: We undertook a single centre cohort study of 724 kidney transplant recipients prospectively screened for serological responses following 3 primary doses of a SARS-CoV2 vaccine. 322 patients were sampled post-V4 for anti-spike (anti-S), with 69 undergoing assessment of SARS-CoV-2 T-cell responses. All vaccine doses were received post-transplant, only mRNA vaccines were used for V3 and V4 dosing. All participants had serological testing performed post-V2 and at least once prior to their first dose of vaccine. Findings: 586/724 (80.9%) patients were infection-naïve post-V3; 141/2586 (24.1%) remained seronegative at 31 (21-51) days post-V3. Timing of vaccination in relation to transplantation, OR: 0.28 (0.15-0.54), p=0.0001; immunosuppression burden, OR: 0.22 (0.13-0.37), p<0.0001, and a diagnosis of diabetes, OR: 0.49 (0.32-0.75), p=0.001, remained independent risk factors for non-seroconversion. Seropositive patients post-V3 had greater anti-S if primed with BNT162b2 compared with ChAdOx1, p=0.001.Post-V4, 45/239 (18.8%) infection-naïve patients remained seronegative. De novo seroconversion post-V4 occurred in 15/60 (25.0%) patients. There was no difference in anti-S post-V4 by vaccine combination, p=0.50. T-cell responses were poor, with only 11/54 (20.4%) infection-naive patients having detectable T-cell responses post-V4, with no difference seen by vaccine type. Interpretation: A significant proportion of transplant recipients remain seronegative following 3- and 4- doses of SARS-CoV-2 vaccines, with poor T-cell responses, and are likely to have inadequate protection against infection. As such alternative strategies are required to provide protection to this vulnerable group. Funding: MW/PK received study support from Oxford Immunotec.

7.
J Clin Virol ; 30 Suppl 1: S11-5, 2004 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-15062762

RESUMO

BACKGROUND: Routine diagnostic laboratories are confronted with an ever-increasing workload with limited resources. Automation has provided some solutions to these challenges particularly high through put analysers such as the Abbott AxSYM. OBJECTIVE: The aim of the present study was to compare the performance of two automated immunoassay systems in a diagnostic virology laboratory. Samples previously tested using the Abbott AxSYM were tested with a recently introduced immunoassay analyser, the Bayer ADVIA Centaur, for six virology analytes: HBsAg, anti-HBc total, anti-HBc IgM, anti-HBs, anti-HCV and anti-HIV1/O/2. STUDY DESIGN: This study was a retrospective analysis of stored serum samples previously tested on the Abbott AxSYM. Samples giving discrepant results were tested by other alternative immunoassays and re-tested on the Abbott AxSYM in the same freeze-thaw cycle. RESULTS: Although the sensitivities of the two automated immunoassays were similar there was improved specificity demonstrated for anti-HIV and anti-HCV when using the ADVIA Centaur assays. The low background signals allowed resolution of samples previously shown to have indeterminate results for anti-HIV antibody in the AxSYM assay. In addition, samples shown to have Abbott AxSYM anti-HCV results that could not be confirmed by RIBA and HCV molecular methods were shown to be negative by the ADVIA Centaur assay.


Assuntos
Sorodiagnóstico da AIDS , Hepatite B/diagnóstico , Hepatite C/diagnóstico , Imunoensaio/métodos , Autoanálise , Reações Falso-Positivas , Anticorpos Anti-HIV/sangue , Anticorpos Anti-Hepatite B/sangue , Antígenos de Superfície da Hepatite B/sangue , Anticorpos Anti-Hepatite C/sangue , Humanos , Imunoglobulina M/sangue , Reprodutibilidade dos Testes , Estudos Retrospectivos , Sensibilidade e Especificidade
SELEÇÃO DE REFERÊNCIAS