RESUMO
BACKGROUND: Endoscopic resection of adenomas prevents colorectal cancer, but the optimal technique for larger lesions is controversial. Piecemeal endoscopic mucosal resection (EMR) has a low adverse event (AE) rate but a variable recurrence rate necessitating early follow-up. Endoscopic submucosal dissection (ESD) can reduce recurrence but may increase AEs. OBJECTIVE: To compare ESD and EMR for large colonic adenomas. DESIGN: Participant-masked, parallel-group, superiority, randomized controlled trial. (ClinicalTrials.gov: NCT03962868). SETTING: Multicenter study involving 6 French referral centers from November 2019 to February 2021. PARTICIPANTS: Patients with large (≥25 mm) benign colonic lesions referred for resection. INTERVENTION: The patients were randomly assigned by computer 1:1 (stratification by lesion location and center) to ESD or EMR. MEASUREMENTS: The primary end point was 6-month local recurrence (neoplastic tissue on endoscopic assessment and scar biopsy). The secondary end points were technical failure, en bloc R0 resection, and cumulative AEs. RESULTS: In total, 360 patients were randomly assigned to ESD (n = 178) or EMR (n = 182). In the primary analysis set (n = 318 lesions in 318 patients), recurrence occurred after 1 of 161 ESDs (0.6%) and 8 of 157 EMRs (5.1%) (relative risk, 0.12 [95% CI, 0.01 to 0.96]). No recurrence occurred in R0-resected cases (90%) after ESD. The AEs occurred more often after ESD than EMR (35.6% vs. 24.5%, respectively; relative risk, 1.4 [CI, 1.0 to 2.0]). LIMITATION: Procedures were performed under general anesthesia during hospitalization in accordance with the French health system. CONCLUSION: Compared with EMR, ESD reduces the 6-month recurrence rate, obviating the need for systematic early follow-up colonoscopy at the cost of more AEs. PRIMARY FUNDING SOURCE: French Ministry of Health.
Assuntos
Adenoma , Neoplasias do Colo , Neoplasias Colorretais , Humanos , Neoplasias do Colo/cirurgia , Neoplasias do Colo/patologia , Colonoscopia/efeitos adversos , Colonoscopia/métodos , Biópsia , Adenoma/cirurgia , Adenoma/patologia , Resultado do Tratamento , Neoplasias Colorretais/cirurgia , Neoplasias Colorretais/patologia , Recidiva Local de Neoplasia , Mucosa Intestinal/patologia , Mucosa Intestinal/cirurgia , Estudos RetrospectivosRESUMO
INTRODUCTION: The environmental impact of endoscopy is a topic of growing interest. This study aimed to compare the carbon footprint of performing an esogastroduodenoscopy (EGD) with a reusable (RU) or with a single-use (SU) disposable gastroscope. METHODS: SU (Ambu aScope Gastro) and RU gastroscopes (Olympus, H190) were evaluated using life cycle assessment methodology (ISO 14040) including the manufacture, distribution, usage, reprocessing and disposal of the endoscope. Data were obtained from Edouard Herriot Hospital (Lyon, France) from April 2023 to February 2024. Primary outcome was the carbon footprint (measured in Kg CO2 equivalent) for both gastroscopes per examination. Secondary outcomes included other environmental impacts. A sensitivity analysis was performed to examine the impact of varying scenarios. RESULTS: Carbon footprint of SU and RU gastroscopes were 10.9 kg CO2 eq and 4.7 kg CO2 eq, respectively. The difference in carbon footprint equals one conventional car drive of 28 km or 6 days of CO2 emission of an average European household. Based on environmentally-extended input-output life cycle assessment, the estimated per-use carbon footprint of the endoscope stack and washer was 0.18 kg CO2 eq in SU strategy versus 0.56 kg CO2 eq in RU strategy. According to secondary outcomes, fossil eq depletion was 130 MJ (SU) and 60.9 MJ (RU) and water depletion for 6.2 m3 (SU) and 9.5 m3 (RU), respectively. CONCLUSION: For one examination, SU gastroscope have a 2.5 times higher carbon footprint than RU ones. These data will help with the logistics and planning of an endoscopic service in relation to other economic and environmental factors.
Assuntos
Pegada de Carbono , Equipamentos Descartáveis , Reutilização de Equipamento , Gastroscópios , Humanos , Endoscopia do Sistema Digestório/instrumentação , FrançaRESUMO
BACKGROUND & AIMS: Conventional endoscopic mucosal resection (C-EMR) is established as the primary treatment modality for superficial nonampullary duodenal epithelial tumors (SNADETs), but recently underwater endoscopic mucosal resection (U-EMR) has emerged as a potential alternative. The majority of previous studies focused on Asian populations and small lesions (≤20 mm). We aimed to compare the efficacy and outcomes of U-EMR vs C-EMR for SNADETs in a Western setting. METHODS: This was a retrospective multinational study from 10 European centers that performed both C-EMR and U-EMR between January 2013 and July 2023. The main outcomes were the technical success, procedure-related adverse events (AEs), and the residual/recurrent adenoma (RRA) rate, evaluated on a per-lesion basis. We assessed the association between the type of endoscopic mucosal resection and the occurrence of AEs or RRAs using mixed-effects logistic regression models (propensity scores). Sensitivity analyses were performed for lesions ≤20 mm or >20 mm. RESULTS: A total of 290 SNADETs submitted to endoscopic resection during the study period met the inclusion criteria and were analyzed (C-EMR: n = 201, 69.3%; U-EMR: n = 89, 30.7%). The overall technical success rate was 95.5% and comparable between groups. In logistic regression models, compared with U-EMR, C-EMR was associated with a significantly higher frequency of overall delayed AEs (odds ratio [OR], 4.95; 95% CI, 2.87-8.53), postprocedural bleeding (OR, 7.92; 95% CI, 3.95-15.89), and RRAs (OR, 3.66; 95% CI, 2.49-5.37). Sensitivity analyses confirmed these results when solely considering either small (≤20 mm) or large (>20 mm) lesions. CONCLUSIONS: Compared with C-EMR, U-EMR was associated with a lower rate of overall AEs and RRAs, regardless of lesion size. Our results confirm the possible role of U-EMR as an effective and safe technique in the management of SNADETs.
RESUMO
INTRODUCTION: When initial resection of rectal neuroendocrine tumors (r-NETs) is not R0, persistence of local residue could lead to disease recurrence. This study aimed to evaluate the interest of systematic resection of non-R0 r-NET scars. METHODS: Retrospective analysis of all the consecutive endoscopic revisions and resections of the scar after non-R0 resections of r-NETs. RESULTS: A total of 100 patients were included. Salvage endoscopic procedure using endoscopic submucosal dissection or endoscopic full-thickness resection showed an R0 rate of near 100%. Residual r-NET was found in 43% of cases. DISCUSSION: In case of non-R0 resected r-NET, systematic scar resection by endoscopic full-thickness resection or endoscopic submucosal dissection seems necessary.
Assuntos
Ressecção Endoscópica de Mucosa , Tumores Neuroendócrinos , Neoplasias Retais , Humanos , Tumores Neuroendócrinos/cirurgia , Cicatriz/etiologia , Cicatriz/patologia , Estudos Retrospectivos , Resultado do Tratamento , Recidiva Local de Neoplasia/cirurgia , Neoplasias Retais/cirurgia , Neoplasias Retais/patologia , Ressecção Endoscópica de Mucosa/métodosRESUMO
INTRODUCTION: The adoption of colorectal endoscopic submucosal dissection (ESD) is still limited in the West. A recent randomized trial showed that ESD is more effective and only slightly riskier than piecemeal endoscopic mucosal resection; reproducibility outside expert centers was questioned. We evaluated the results according to the annual case volume in a multicentric prospective cohort. METHODS: Between September 2019 and September 2022, colorectal ESD was consecutively performed at 13 participating centers classified as low volume (LV), middle volume (MV), and high volume (HV). The main procedural outcomes were assessed. Multivariate and propensity score matching analyses were performed. RESULTS: Three thousand seven hundred seventy ESDs were included. HV centers treated larger and more often colonic lesions than MV and LV centers. En bloc , R0, and curative resection rates were 95.2%, 87.4%, and 83.2%, respectively, and were higher at HV than at MV and LV centers. HV centers also achieved a faster dissection speed. Delayed bleeding and surgery for complications rates were 5.4% and 0.8%, respectively, without significant differences. The perforation rate (overall: 9%) was higher at MV than at LV and HV centers. Lesion characteristics, but not volume center, were independently associated with both R1 resection and perforation. However, after propensity score matching, R0 rates were significantly higher at HV than at LV centers, and perforation rates were significantly higher at MV than at HV centers. DISCUSSION: Colorectal ESD can be successfully implemented in the West, even in nonexpert centers. However, difficult lesions must still be referred to experts.
RESUMO
BACKGROUND AND AIMS: Juvenile polyposis syndrome (JPS) is a rare hereditary autosomal dominant cancer-predisposition syndrome caused by germline pathogenic variants (PVs) located in SMAD4 or BMPR1A genes. Accurate clinical and endoscopic data regarding the evolution of gastric lesions remain sparse. METHODS: Clinical, endoscopic, genetic, and pathologic data from patients with SMAD4 or BMPR1A PVs included between 2007 and 2020 in the French network on rare digestive polyposis (RENAPOL [French National Polyposis Register]) database were prospectively collected to address uncertainties regarding gastric involvement. RESULTS: Thirty-six patients were included: 25 (69.5%) had SMAD4 PVs, and 11 had BMPR1A PVs. For SMAD4 PV carriers, median age at inclusion was 43.0 years (range, 10-78 years). At baseline EGD, 22 (88%) of 25 patients exhibited at least 1 gastric juvenile polyp, and 5 (20%) of 25 had macroscopic signs of inflammatory gastritis. Early gastric disease was mostly located under the cardia, then progressed to the gastric antrum and body. During a mean follow-up period of 55.0 months, 12 of 25 patients had gastric disease progression (ie, new juvenile polyps [91.6%], diffuse gastric involvement [41.6%], inflammatory flat progression [25%]). Among 62 biopsies, low-grade dysplasia was observed in 5 (7.5%) samples from 2 patients. Nine carriers (36%) underwent gastrectomy (mean age, 47.2 years) due to diffuse gastric involvement or worsening clinical symptoms. Gastric adenocarcinoma (T1) was found in 1 gastrectomy specimen. Among the 11 patients with BMPR1A PVs, 2 had gastric hamartomatomas at baseline EGD, none with dysplasia or symptoms. CONCLUSIONS: Gastric involvement in JPS seems to be progressive over a lifetime, initiates in the cardia area, and mostly involves SMAD4 PV carriers.
RESUMO
BACKGROUND AND AIMS: Achalasia can be treated very effectively with peroral endoscopic myotomy (POEM), but factors associated with early failure remain to be determined, especially in European cohorts. METHODS: All consecutive adult patients who underwent a first POEM to treat primary achalasia were included in this multicenter retrospective study. Early failure was defined by an Eckardt score (ES) >3 at 3 months after POEM. When evaluating factors predictive of early failure, 2 cohorts were considered: one consisted of the total population, for whom only basic variables were collected, and the other a cohort built for a case-control study that included matched early-failure and early-success patients (ratio, 1:2). RESULTS: Among 746 patients, the early failure rate was 9.4%. Predictive factors were age ≤45 years (P = .019), achalasia types I and III (P < .001), and the development of a severe adverse event during the procedure (P = .023). In the case-control study, the only additional independent risk factor for early failure was a high pre-POEM ES (P = .001). Only the retrosternal pain subscore was significantly associated with the early failure rate. CONCLUSION: The early failure rate of POEM used to treat primary achalasia is <10%. Younger age, type I/III achalasia, and a high pre-POEM ES were significantly associated with failure.
Assuntos
Acalasia Esofágica , Miotomia , Cirurgia Endoscópica por Orifício Natural , Adulto , Humanos , Pessoa de Meia-Idade , Acalasia Esofágica/cirurgia , Acalasia Esofágica/etiologia , Estudos Retrospectivos , Estudos de Casos e Controles , Cirurgia Endoscópica por Orifício Natural/efeitos adversos , Cirurgia Endoscópica por Orifício Natural/métodos , Miotomia/efeitos adversos , Miotomia/métodos , Resultado do Tratamento , Esfíncter Esofágico Inferior/cirurgiaRESUMO
BACKGROUND AND AIMS: Traction has become the reference strategy for colorectal endoscopic submucosal dissection (ESD). One of its major limitations is that the force of traction decreases as dissection progresses. The ATRACT traction device (ATRACT Device and Co, Lyon, France) uses a pulley system to increase traction during the procedure, making it easier and faster. A retrospective study of 54 cases showed interesting results in terms of efficacy and safety throughout the digestive tract. We sought to confirm these initial results with a prospective study of resections of colorectal lesions. METHODS: In this prospective multicenter study, 5 experienced operators from 3 different centers each performed 10 procedures using the ATRACT device consecutively for all conventional colorectal ESDs measuring between 4 and 10 cm in conventional locations (no recurrent lesions, appendicular, of the ileocecal valve, in contact with the pectinate line, or measuring more than two-thirds of the circumference). RESULTS: Between November 2022 and April 2023, 50 ESDs were performed in 49 patients. On average, the main diameter of the lesions was 66.6 mm, with a surface area of 3066 mm2. The mean operating time was 55.2 minutes, resulting in a mean resection speed of 61.4 mm2/min. En bloc and R0 resection rates were 100% and 98%, respectively. Resections were curative in 94% of cases. Four (8%) perforations occurred, all of which were closed endoscopically without the need for surgery. One (2%) case of delayed hemorrhage was noted. To date, this is the series with the highest resection speeds in the literature for colorectal ESD. For comparison, previous studies reported a speed of 23.5 mm2/min using the "pocket" strategy and a speed of 39.1 mm2/min using the double-clip traction technique. These results need to be confirmed in larger studies and in nonexpert centers. CONCLUSIONS: This prospective evaluation confirms the efficacy and safety of the adaptive traction strategy with the ATRACT device for colorectal ESD with high resection speed.
Assuntos
Neoplasias Colorretais , Ressecção Endoscópica de Mucosa , Duração da Cirurgia , Tração , Humanos , Ressecção Endoscópica de Mucosa/métodos , Ressecção Endoscópica de Mucosa/instrumentação , Estudos Prospectivos , Masculino , Feminino , Idoso , Pessoa de Meia-Idade , Neoplasias Colorretais/cirurgia , Tração/métodos , Tração/instrumentação , Idoso de 80 Anos ou mais , Colonoscopia/métodos , Mucosa Intestinal/cirurgia , Perfuração Intestinal/etiologia , Perfuração Intestinal/cirurgiaRESUMO
BACKGROUND AND AIMS: EUS-guided placement of fiducial markers in patients with esophageal or rectal cancer who have been referred for radiation therapy lacks data regarding its feasibility and safety. The aim of this study was to assess the success rate of EUS-guided fiducial marker placement in these indications. METHODS: This prospective multicenter study enrolled patients with rectal or esophageal tumors who were treated between March 2017 and June 2021. The primary endpoint was the success of fiducial marker placement under EUS guidance utilizing the preloaded 22-gauge EchoTip Ultra Fiducial Needle (Cook Medical, Limerick, Ireland), defined by the ability to release fiducials at least at the proximal and distal ends of the tumor. Secondary endpoints were the adverse events, length of procedure, and fiducial markers remaining throughout radiation therapy. RESULTS: A total of 33 patients were included in this study, with a mean age of 64.2 ± 11.3 years; 66.7% were male. Twenty patients had rectal adenocarcinoma, and 13 had esophageal malignancies. The success rate of fiducial marker placement was 93.9%. Markers could only be released at the proximal end of the tumor in 2 cases. The average procedure time (±SD) was 12.5 ± 4.8 minutes. The number of fiducial markers placed for each patient was 3.8 ± .5. No adverse events were reported. At the end of radiotherapy, markers were still visible on imaging in all patients. CONCLUSIONS: This prospective multicenter study highlights the safety and high success of the placement of fiducial markers under EUS guidance for rectal and esophageal tumors, with no adverse events and with a short procedure time. Fiducial markers remained in place over time during radiation therapy. (Clinical trial registration number: NCT03057288.).
RESUMO
BACKGROUND AND AIMS: The muscle retracting sign (MRS) can be present during endoscopic submucosal dissection (ESD) of macronodular colorectal lesions. The prevalence of MRS and its pathologic and clinical implications is unclear. This study evaluated the effect of MRS on the technical and clinical outcomes of ESD. METHODS: All patients referred for ESD of protruding lesions or granular mixed lesions with >10 mm macronodule granular mixed laterally spreading tumors (LST-GMs) in 2 academic centers from January 2017 to October 2022 were prospectively included. Size of the macronodule was analyzed retrospectively. The primary outcome was the curative resection rate according to MRS status. Secondary outcomes were R0 resection, perforation, secondary surgery rate, and risk factors for MRS. RESULTS: Of 694 lesions, 84 (12%) had MRS (MRS+). The curative resection rate was decreased by MRS (MRS+ 41.6% vs lesions without MRS [MRS-] 81.3%), whereas the perforation (MRS+ 22.6% vs MRS- 9.2%), submucosal cancer (MRS+ 34.9% vs MRS- 9.2%), and surgery (MRS+ 45.2% vs MRS- 6%) rates were increased. The R0 resection rate of MRS+ colonic lesions was lower than that of rectal lesions (53% vs 74.3%). In multivariate analysis, protruding lesions (odds ratio, 2.47; 95% confidence interval, 1.27-4.80) and macronodules >4 cm (odds ratio, 4.24; 95% confidence interval, 2.23-8.05) were risk factors for MRS. CONCLUSIONS: MRS reduces oncologic outcomes and increases the perforation rate. Consequently, procedures in the colon should be stopped if MRS is detected, and those in the rectum should be continued due to the morbidity of alternative therapy.
Assuntos
Neoplasias Colorretais , Ressecção Endoscópica de Mucosa , Humanos , Prevalência , Estudos Retrospectivos , Relevância Clínica , Dissecação/métodos , Músculos/patologia , Neoplasias Colorretais/patologia , Resultado do Tratamento , Mucosa Intestinal/cirurgia , Mucosa Intestinal/patologiaRESUMO
BACKGROUND AND AIMS: We aimed to compare the long-term outcomes of patients with high-risk T1 colorectal cancer (CRC) resected endoscopically who received either additional surgery or surveillance. METHODS: We used data from routine care to emulate a target trial aimed at comparing 2 strategies after endoscopic resection of high-risk T1 CRC: surgery with lymph node dissection (treatment group) versus surveillance alone (control group). All patients from 14 tertiary centers who underwent an endoscopic resection for high-risk T1 CRC between March 2012 and August 2019 were included. The primary outcome was a composite outcome of cancer recurrence or death at 48 months. RESULTS: Of 197 patients included in the analysis, 107 were categorized in the treatment group and 90 were categorized in the control group. From baseline to 48 months, 4 of 107 patients (3.7%) died in the treatment group and 6 of 90 patients (6.7%) died in the control group. Four of 107 patients (3.7%) in the treatment group experienced a cancer recurrence and 4 of 90 patients (4.4%) in the control group experienced a cancer recurrence. After balancing the baseline covariates by inverse probability of treatment weighting, we found no significant difference in the rate of death and cancer recurrence between patients in the 2 groups (weighted hazard ratio, .95; 95% confidence interval, .52-1.75). CONCLUSIONS: Our study suggests that patients with high-risk T1 CRC initially treated with endoscopic resection may not benefit from additional surgery.
Assuntos
Neoplasias Colorretais , Recidiva Local de Neoplasia , Humanos , Estudos Retrospectivos , Recidiva Local de Neoplasia/patologia , Neoplasias Colorretais/cirurgia , Neoplasias Colorretais/patologia , Endoscopia/métodos , Excisão de Linfonodo , Fatores de Risco , Resultado do TratamentoRESUMO
BACKGROUND AND AIMS: There are few data favoring the need for septotomy at the time of peroral endoscopic myotomy (POEM) or if POEM alone is sufficient. Our aim was to compare POEM outcomes with and without septotomy (POEM+S or POEM-S) in patients with symptomatic epiphrenic diverticula (ED) and an underlying motility disorder. METHODS: This was an international, multicenter retrospective study involving 21 centers between January 2014 and January 2023. Patients with ED and an underlying motility disorder who underwent POEM were included. The primary outcome was clinical success (Eckardt score [ES] ≤3 or a 1-point drop in ES for patients with baseline ES <3) without the need for repeat surgical/endoscopic interventions during follow-up. RESULTS: A total of 85 patients (mean age, 64.29 ± 17.1 years; 32 [37.6%] female) with ED and underlying motility disorder underwent POEM+S (n = 47) or POEM-S (n = 38). Patients in the POEM+S group had a significantly higher mean pre-POEM ES (7.3 ± 2.1 vs 5.8 ± 2; P = .002). The most common indication for POEM was achalasia (51% in the POEM+S cohort and 51.8% in the POEM-S cohort; P = .7). A posterior approach was favored in the POEM+S group (76.6% vs 52.6%; P = .02). A similar rate of technical success was seen in both groups (97.9% vs 100%; P = .1). The rate of adverse events was similar between the 2 cohorts (4.2% vs 8.1%; P = .6). The median length of hospital stay after POEM-S was significantly longer compared with POEM+S (2 days [interquartile range (IQR), 1-4 days] vs 1 day [IQR, 1-2 days]; P = .005). Clinical success was equivalent between the 2 groups (83% vs 86.8%; P = .6) at a median follow-up duration of 8 months (IQR, 3-19 months). CONCLUSIONS: In patients with ED and an underlying motility disorder, both POEM+S and POEM-S are equally safe and effective, with similar procedure duration and a low recurrence rate at short-term follow-up. Future comparative prospective studies with long-term follow-up are required to validate these findings.
RESUMO
BACKGROUND AND AIMS: Circumferential endoscopic submucosal dissection (cESD) in the esophagus has been reported to be feasible in small Eastern case series. We assessed the outcomes of cESD in the treatment of early esophageal squamous cell carcinoma (ESCC) in Western countries. METHODS: We conducted an international study at 25 referral centers in Europe and Australia using prospective databases. We included all patients with ESCC treated with cESD before November 2022. Our main outcomes were curative resection according to European guidelines and adverse events. RESULTS: A total of 171 cESDs were performed on 165 patients. En bloc and R0 resections rates were 98.2% (95% confidence interval [CI], 95.0-99.4) and 69.6% (95% CI, 62.3-76.0), respectively. Curative resection was achieved in 49.1% (95% CI, 41.7-56.6) of the lesions. The most common reason for noncurative resection was deep submucosal invasion (21.6%). The risk of stricture requiring 6 or more dilations or additional techniques (incisional therapy/stent) was high (71%), despite the use of prophylactic measures in 93% of the procedures. The rates of intraprocedural perforation, delayed bleeding, and adverse cardiorespiratory events were 4.1%, 0.6%, and 4.7%, respectively. Two patients died (1.2%) of a cESD-related adverse event. Overall and disease-free survival rates at 2 years were 91% and 79%. CONCLUSIONS: In Western referral centers, cESD for ESCC is curative in approximately half of the lesions. It can be considered a feasible treatment in selected patients. Our results suggest the need to improve patient selection and to develop more effective therapies to prevent esophageal strictures.
Assuntos
Ressecção Endoscópica de Mucosa , Neoplasias Esofágicas , Carcinoma de Células Escamosas do Esôfago , Humanos , Carcinoma de Células Escamosas do Esôfago/cirurgia , Neoplasias Esofágicas/patologia , Ressecção Endoscópica de Mucosa/métodos , Esofagoscopia/métodos , Resultado do Tratamento , Estudos RetrospectivosRESUMO
BACKGROUND : Good submucosal exposure is key to successful endoscopic submucosal dissection (ESD) and can be achieved with various traction devices. Nevertheless, these devices have a fixed traction force that tends to decrease as the dissection progresses. In contrast, the ATRACT adaptive traction device increases traction during the procedure. METHODS : In this retrospective analysis of prospectively collected data (from a French database), we analyzed ESD procedures performed with the ATRACT device between April 2022 and October 2022. The device was used consecutively whenever possible. We collected details of lesion characteristics, procedural data, histologic outcomes, and clinical consequences for the patient. RESULTS : 54 resections performed in 52 patients by two experienced operators (46 procedures) and six novices (eight procedures) were analyzed. The ATRACT devices used were the ATRACT-2 (nâ=â21), the ATRACT 2â+â2 (nâ=â30), and the ATRACT-4 (nâ=â3). Four adverse events were observed: one perforation (1.9â%), which was closed endoscopically, and three delayed bleeding events (5.5â%). The R0 rate was 93â%, resulting in curative resection in 91â% of cases. CONCLUSION: ESD using the ATRACT device is safe and effective in the colon and rectum, but can also be used to assist with procedures in the upper gastrointestinal tract. It may be particularly useful in difficult locations.
Assuntos
Ressecção Endoscópica de Mucosa , Humanos , Ressecção Endoscópica de Mucosa/métodos , Estudos Retrospectivos , Reto , Dissecação/efeitos adversos , Dissecação/métodos , Tração , Resultado do TratamentoRESUMO
INTRODUCTION: Gastric peroral endoscopic myotomy (G-POEM) is a promising technique for treating refractory gastroparesis. We present the first double-blind randomized study comparing the clinical efficacy of G-POEM versus pyloric botulinum toxin injection (BTI). METHODS: This randomized study, conducted in two expert centers, enrolled patients with refractory gastroparesis, medically managed for >6 months and confirmed by gastric emptying scintigraphy (GES), into two groups, G-POEM versus BTI, with follow-up of 1 year. The primary end point was the 3-month clinical efficacy, defined as a >1-point decrease in the mean Gastroparesis Cardinal Symptom Index (GCSI) score. Secondary end points were: 1-year efficacy, GES evolution, adverse events, and quality of life. RESULTS: 40 patients (22 women; mean age 48.1 [SD 17.4]), with mean symptom duration of 5.8 (SD 5.7) years, were randomized. Etiologies included idiopathic (n=18), diabetes (n=11), postoperative (n=6), and mixed (n=4). G-POEM showed a higher 3-month clinical success than BTI (65% vs. 40%, respectively; P=0.10), along with non-significantly higher 1-year clinical success (60% vs. 40%, respectively) on intention-to-treat analysis. The GCSI decreased in both groups at 3 months and 1 year. Only three minor adverse events occurred in the G-POEM group. The GES improvement rate was 72% in the G-POEM group versus 50% in the BTI group (non-significant). CONCLUSION: G-POEM seems to have a higher clinically relevant success rate than BTI, but this was not statistically demonstrated. This study confirms the interest in treatments targeting the pylorus, either mechanically or chemically, for managing refractory gastroparesis.
Assuntos
Toxinas Botulínicas , Gastroparesia , Piloromiotomia , Adulto , Idoso , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Toxinas Botulínicas/administração & dosagem , Toxinas Botulínicas/efeitos adversos , Esvaziamento Gástrico/efeitos dos fármacos , Gastroparesia/tratamento farmacológico , Gastroparesia/etiologia , Gastroparesia/cirurgia , Gastroscopia , Injeções , Piloromiotomia/métodos , Piloromiotomia/efeitos adversos , Piloro/cirurgia , Qualidade de Vida , Cintilografia , Resultado do TratamentoRESUMO
BACKGROUND: The ileocecal valve (ICV) is considered to be one of the most difficult locations for endoscopic submucosal dissection (ESD). The objective of this study was to evaluate the efficacy and safety of traction-assisted ESD in this situation. METHODS: All patients who underwent traction-assisted ESD for an ICV lesion at three centers were identified from a prospective ESD database. En bloc and R0 rates were evaluated. Factors associated with non-R0 resection were explored. RESULTS: 106 patients with an ICV lesion were included. The median lesion size was 50 mm (interquartile range 38-60) and 58.5% (62/106) invaded the terminal ileum. The en bloc and R0 resection rates were 94.3% and 76.4%, respectively. Factors associated with non-R0 resection were lesions covering ≥75% of the ICV (odds ratio [OR] 0.21. 95%CI 0.06-0.76; P=0.02), and involving the anal lip (OR 0.36, 95%CI 0.13-0.99; P=0.04) or more than two sites on the ICV (OR 0.27, 95%CI 0.07-0.99; P=0.03). CONCLUSION: Traction-assisted ESD for treatment of ICV lesions was a safe and feasible option. Large lesions and anal lip involvement appeared to be factors predictive of difficulty.
Assuntos
Ressecção Endoscópica de Mucosa , Neoplasias do Íleo , Valva Ileocecal , Humanos , Ressecção Endoscópica de Mucosa/métodos , Ressecção Endoscópica de Mucosa/efeitos adversos , Masculino , Feminino , Valva Ileocecal/cirurgia , Estudos Retrospectivos , Idoso , Neoplasias do Íleo/cirurgia , Neoplasias do Íleo/patologia , Pessoa de Meia-Idade , Tração/métodos , França , Resultado do Tratamento , Idoso de 80 Anos ou mais , Mucosa Intestinal/cirurgia , Mucosa Intestinal/patologiaRESUMO
BACKGROUND: Clinically significant delayed bleeding (CSDB) is a frequent, and sometimes severe, adverse event after colorectal endoscopic submucosal dissection (ESD). We evaluated risk factors of CSDB after colorectal ESD. METHODS: We analyzed a prospective registry of 940 colorectal ESDs performed from 2013 to 2022. The incidence of bleeding was evaluated up to 30 days. Risk factors for delayed bleeding were evaluated by multivariate logistic regression. A Korean scoring model was tested, and a new risk-scoring model was developed and internally validated. RESULTS: CSDB occurred in 75 patients (8.0%). The Korean score performed poorly in our cohort, with a receiver operating characteristic (ROC) curve of 0.567. In the multivariate analysis, risk factors were age ≥75 years (odds ratio [OR] 1.63; 95%CI 0.97-2.73; 1 point), use of antithrombotics (OR 1.72; 95%CI 1.01-2.94; 1 point), rectal location (OR 1.51; 95%CI 0.92-2.48; 1 point), size >50 mm (OR 3.67; 95%CI 2.02-7.14; 3 points), and American Society of Anesthesiologists (ASA) score of III or IV (OR 2.26; 95%CI 1.32-3.92; 2 points). The model showed fair calibration and good discrimination, with an area under the ROC curve of 0.751 (95%CI 0.690-0.812). The score was used to define two groups of patients, those with low-medium risk (0 to 4 points) and high risk (5 to 8 points) for CSDB (respective bleeding rates 4.1% and 17.5%). CONCLUSION: A score based on five simple and meaningful variables was predictive of CSDB.
Assuntos
Neoplasias Colorretais , Ressecção Endoscópica de Mucosa , Neoplasias Gástricas , Humanos , Idoso , Ressecção Endoscópica de Mucosa/efeitos adversos , Estudos Retrospectivos , Hemorragia/etiologia , Fatores de Risco , Neoplasias Colorretais/cirurgia , Hemorragia Pós-Operatória/epidemiologia , Hemorragia Pós-Operatória/etiologiaRESUMO
BACKGROUND: This study evaluated the safety and efficacy of salvage endoscopic submucosal dissection (ESD) for Barrett's neoplasia recurrence after radiofrequency ablation (RFA). METHODS: Data from patients at 16 centers were collected for a multicenter retrospective study. Patients who underwent at least one RFA treatment for Barrett's esophagus and thereafter underwent further esophageal ESD for neoplasia recurrence were included. RESULTS: Data from 56 patients who underwent salvage ESD between April 2014 and November 2022 were collected. Immediate complications included one muscular tear (1.8%) treated with stent (Agree classification: grade IIIa). Two transmural perforations (3.6%; treated with clips) and five muscular tears (8.9%; two treated with clips) had no clinical impact and were not considered as adverse events. Seven patients (12.5%) developed strictures (grade IIIa), which were treated with balloon dilation. Histological analysis showed 36 adenocarcinoma, 17 high grade dysplasia, and 3 low grade dysplasia. En bloc and R0 resection rates were 89.3% and 66.1%, respectively. Resections were curative in 33 patients (58.9%), and noncurative in 22 patients (39.3%), including 11 "local risk" (19.6%) and 11 "high risk" (19.6%) resections. At the end of follow-up with a median time of 14 (0-75) months after salvage ESD, and with further endoscopic treatment if necessary (RFA, argon plasma coagulation, endoscopic mucosal resection, ESD), neoplasia remission ratio was 37/53 (69.8%) and the median remission time was 13 (1-75) months. CONCLUSION: In expert hands, salvage ESD was a safe and effective treatment for recurrence of Barrett's neoplasia after RFA treatment.
Assuntos
Esôfago de Barrett , Ressecção Endoscópica de Mucosa , Neoplasias Esofágicas , Recidiva Local de Neoplasia , Ablação por Radiofrequência , Terapia de Salvação , Humanos , Esôfago de Barrett/cirurgia , Esôfago de Barrett/patologia , Ressecção Endoscópica de Mucosa/efeitos adversos , Ressecção Endoscópica de Mucosa/métodos , Masculino , Feminino , Idoso , Estudos Retrospectivos , Terapia de Salvação/métodos , Pessoa de Meia-Idade , Neoplasias Esofágicas/cirurgia , Neoplasias Esofágicas/patologia , Ablação por Radiofrequência/efeitos adversos , Ablação por Radiofrequência/métodos , Adenocarcinoma/cirurgia , Adenocarcinoma/patologia , Estenose Esofágica/etiologia , Idoso de 80 Anos ou mais , Resultado do Tratamento , Esofagoscopia/métodos , Esofagoscopia/efeitos adversosRESUMO
INTRODUCTION: The environmental impact of endoscopy, including small-bowel capsule endoscopy (SBCE), is a topic of growing attention and concern. This study aimed to evaluate the greenhouse gas (GHG) emissions (kgCO2) generated by an SBCE procedure. METHODS: Life cycle assessment methodology (ISO 14040) was used to evaluate three brands of SBCE device and included emissions generated by patient travel, bowel preparation, capsule examination, and video recording. A survey of 87 physicians and 120 patients was conducted to obtain data on travel, activities undertaken during the procedure, and awareness of environmental impacts. RESULTS: The capsule itself (4âg) accounted forâ<â6â% of the total product weight. Packaging (43-119âg) accounted for 9â%-97â% of total weight, and included deactivation magnets (5âg [4â%-6â%]) and paper instructions (11-50âg [up to 40â%]). A full SBCE procedure generated approximately 20âkgCO2, with 0.04âkgCO2 (0.2â%) attributable to the capsule itself and 18âkgCO2 (94.7â%) generated by patient travel. Capsule retrieval using a dedicated device would add 0.98âkgCO2 to the carbon footprint. Capsule deconstruction revealed materials (e.âg. neodymium) that are prohibited from environmental disposal; 76â% of patients were not aware of the illegal nature of capsule disposal via wastewater, and 63â% would have been willing to retrieve it. The carbon impact of data storage and capsule reading was negligible. CONCLUSION: The carbon footprint of SBCE is mainly determined by patient travel. The capsule device itself has a relatively low carbon footprint. Given that disposal of capsule components via wastewater is illegal, retrieval of the capsule is necessary but would likely be associated with an increase in device-related emissions.
Assuntos
Endoscopia por Cápsula , Intestino Delgado , Humanos , Endoscopia por Cápsula/métodos , Endoscopia por Cápsula/instrumentação , Intestino Delgado/diagnóstico por imagem , Pegada de Carbono , Viagem , Cápsulas Endoscópicas , Gases de Efeito Estufa/efeitos adversos , Gases de Efeito Estufa/análise , Masculino , Adulto , FemininoRESUMO
BACKGROUND: Gastrointestinal (GI) endoscopy is one of healthcare's main contributors to climate change. We aimed to assess healthcare professionals' attitudes and the perceived barriers to implementation of sustainable GI endoscopy. METHODS: The LEAFGREEN web-based survey was a cross-sectional study conducted by the European Society of Gastrointestinal Endoscopy (ESGE) Green Endoscopy Working Group. The questionnaire comprised 39 questions divided into five sections (respondent demographics; climate change and sustainability beliefs; waste and resource management; single-use endoscopes and accessories; education and research). The survey was available via email to all active members of the ESGE and the European Society of Gastroenterology and Endoscopy Nurses and Associates (ESGENA) in March 2023. RESULTS: 407 respondents participated in the survey (11% response rate). Most participants (86%) agreed climate change is real and anthropogenic, but one-third did not consider GI endoscopy to be a significant contributor to climate change. Improvement in the appropriateness of endoscopic procedures (41%) and reduction in single-use accessories (34%) were considered the most important strategies to reduce the environmental impact of GI endoscopy. Respondents deemed lack of institutional support and knowledge from staff to be the main barriers to sustainable endoscopy. Strategies to reduce unnecessary GI endoscopic procedures and comparative studies of single-use versus reusable accessories were identified as research priorities. CONCLUSIONS: In this survey, ESGE and ESGENA members acknowledge climate change as a major threat to humanity. Further improvement in sustainability beliefs and professional attitudes, reduction in inappropriate GI endoscopy, and rational use of single-use accessories and endoscopes are critically required.