Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 11 de 11
Filtrar
1.
Biomed Opt Express ; 13(3): 1344-1356, 2022 Mar 01.
Artigo em Inglês | MEDLINE | ID: mdl-35414986

RESUMO

Recently proposed time-gated diffuse correlation spectroscopy (TG-DCS) has significant advantages compared to conventional continuous wave (CW)-DCS, but it is still in an early stage and clinical capability has yet to be established. The main challenge for TG-DCS is the lower signal-to-noise ratio (SNR) when gating for the deeper traveling late photons. Longer wavelengths, such as 1064 nm have a smaller effective attenuation coefficient and a higher power threshold in humans, which significantly increases the SNR. Here, we demonstrate the clinical utility of TG-DCS at 1064 nm in a case study on a patient with severe traumatic brain injury admitted to the neuro-intensive care unit (neuroICU). We showed a significant correlation between TG-DCS early (ρ = 0.67) and late (ρ = 0.76) gated against invasive thermal diffusion flowmetry. We also analyzed TG-DCS at high temporal resolution (50 Hz) to elucidate pulsatile flow data. Overall, this study demonstrates the first clinical translation capability of the TG-DCS system at 1064 nm using a superconducting nanowire single-photon detector.

2.
J Biophotonics ; 14(11): e202000454, 2021 11.
Artigo em Inglês | MEDLINE | ID: mdl-34328247

RESUMO

There is a need for quantitative biomarkers for early diagnosis of autism. Cerebral blood flow and oxidative metabolism parameters may show superior contrasts for improved characterization. Diffuse correlation spectroscopy (DCS) has been shown to be reliable method to obtain cerebral blood flow contrast in animals and humans. Thus, in this study, we evaluated the combination of DCS and fNIRS in an established autism mouse model. Our results indicate that autistic group had significantly (P = .001) lower (~40%) blood flow (1.16 ± 0.26) × 10-8  cm2 /s), and significantly (P = .015) lower (~70%) oxidative metabolism (52.4 ± 16.6 µmol/100 g/min) compared to control group ([1.93 ± 0.74] × 10-8  cm2 /s, 177.2 ± 45.8 µmol/100 g/min, respectively). These results suggest that the combination of DCS and fNIRS can provide hemodynamic and metabolic contrasts for in vivo assessment of autism pathological conditions noninvasively.


Assuntos
Transtorno Autístico , Espectroscopia de Luz Próxima ao Infravermelho , Animais , Circulação Cerebrovascular , Camundongos , Consumo de Oxigênio , Perfusão
3.
Brain Sci ; 11(8)2021 Aug 20.
Artigo em Inglês | MEDLINE | ID: mdl-34439712

RESUMO

Survivors of severe brain injury may require care in a neurointensive care unit (neuro-ICU), where the brain is vulnerable to secondary brain injury. Thus, there is a need for noninvasive, bedside, continuous cerebral blood flow monitoring approaches in the neuro-ICU. Our goal is to address this need through combined measurements of EEG and functional optical spectroscopy (EEG-Optical) instrumentation and analysis to provide a complementary fusion of data about brain activity and function. We utilized the diffuse correlation spectroscopy method for assessing cerebral blood flow at the neuro-ICU in a patient with traumatic brain injury. The present case demonstrates the feasibility of continuous recording of noninvasive cerebral blood flow transients that correlated well with the gold-standard invasive measurements and with the frequency content changes in the EEG data.

4.
Biomed Opt Express ; 11(10): 5557-5564, 2020 Oct 01.
Artigo em Inglês | MEDLINE | ID: mdl-33149970

RESUMO

Diffuse correlation spectroscopy (DCS) is increasingly used in the optical imaging field to assess blood flow in humans due to its non-invasive, real-time characteristics and its ability to provide label-free, bedside monitoring of blood flow changes. Previous DCS studies have utilized a traditional curve fitting of the analytical or Monte Carlo models to extract the blood flow changes, which are computationally demanding and less accurate when the signal to noise ratio decreases. Here, we present a deep learning model that eliminates this bottleneck by solving the inverse problem more than 2300% faster, with equivalent or improved accuracy compared to the nonlinear fitting with an analytical method. The proposed deep learning inverse model will enable real-time and accurate tissue blood flow quantification with the DCS technique.

5.
J Vis Exp ; (159)2020 05 27.
Artigo em Inglês | MEDLINE | ID: mdl-32538897

RESUMO

To obtain a comprehensive understanding of the human brain, utilization of cerebral blood flow (CBF) as a source of contrast is desired because it is a key hemodynamic parameter related to cerebral oxygen supply. Resting state low frequency fluctuations based on oxygenation contrast have been shown to provide correlations between functionally connected regions. The presented protocol uses optical diffuse correlation spectroscopy (DCS) to assess blood flow-based resting state functional connectivity (RSFC) in the human brain. Results of CBF-based RSFC in human frontal cortex indicate that intra-regional RSFC is significantly higher in the left and right cortices compared to inter-regional RSFC in both cortices. This protocol should be of interest to researchers who employ multi-modal imaging techniques to study human brain function, especially in the pediatric population.


Assuntos
Encéfalo/irrigação sanguínea , Circulação Cerebrovascular , Análise Espectral , Adulto , Encéfalo/fisiologia , Córtex Cerebral/irrigação sanguínea , Córtex Cerebral/fisiologia , Circulação Cerebrovascular/fisiologia , Lobo Frontal/irrigação sanguínea , Lobo Frontal/fisiologia , Humanos
6.
Biomed Opt Express ; 10(9): 4676-4683, 2019 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-31565518

RESUMO

We investigated the change in optical properties and vascular parameters to characterize skin tissue from mild photodamage to actinic keratosis (AK) with comparison to a published photodamage scale. Multi-wavelength spatial frequency domain imaging (SFDI) measurements were performed on the dorsal forearms of 55 adult subjects with various amounts of photodamage. Dermatologists rated the levels of photodamage based upon the photographs in blinded fashion to allow comparison with SFDI data. For characterization of statistical data, we used artificial neural networks. Our results indicate that optical and vascular parameters can be used to quantify photodamage and can discriminate between the stages as low, medium, and high grades, with the best performance of ∼70%, ∼76% and 80% for characterization of low- medium- and high-grade lesions, respectively. Ultimately, clinicians can use this noninvasive approach for risk assessment and frequent monitoring of high-risk populations.

7.
J Biophotonics ; 11(2)2018 02.
Artigo em Inglês | MEDLINE | ID: mdl-28708329

RESUMO

Near-infrared diffuse correlation spectroscopy (DCS) is used to record spontaneous cerebral blood flow fluctuations in the frontal cortex. Nine adult subjects participated in the experiments, in which 8-minute spontaneous fluctuations were simultaneously recorded from the left and right dorsolateral and inferior frontal regions. Resting-state functional connectivity (RSFC) was measured by the temporal correlation of the low frequency fluctuations. Our data shows the RSFC within the dorsolateral region is significantly stronger than that between the inferior and dorsolateral regions, in line with previous observations with functional near-infrared spectroscopy. This indicates that DCS is capable of investigating brain functional connectivity in terms of cerebral blood flow.


Assuntos
Encéfalo/fisiologia , Circulação Cerebrovascular , Rede Nervosa/fisiologia , Descanso , Espectroscopia de Luz Próxima ao Infravermelho , Adulto , Encéfalo/irrigação sanguínea , Feminino , Lobo Frontal/irrigação sanguínea , Lobo Frontal/fisiologia , Humanos , Masculino , Rede Nervosa/irrigação sanguínea
8.
Toxicol In Vitro ; 52: 251-254, 2018 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-29859991

RESUMO

Early knowledge about burn severity and depth can lead to improved outcome for patients. In this study, we investigated the change in optical properties in ex vivo human skin following thermal burn injuries. Human skin removed during body contouring procedures was subjected to thermal burn injury for either 10 or 60 s. Multi-wavelength spatial frequency domain imaging (SFDI) measurements were performed on each sample and the optical properties (absorption and scattering parameters) were obtained at each wavelength. Multi-wavelength fitting was used to quantify absorption and scattering parameters, and these parameters were compared to histologic assessments of burn depth related to burn severity. Our results indicated substantial changes in optical scattering parameters and these changes correlated well with the burn severity and depth, and fit closely with previously reported studies using porcine in vivo models. This study provides the characterization of thermal burn injury on human skin ex vivo by using the optical method of SFDI with high sensitivity and specificity. This preclinical human model system without live animals could have uses in testing the imaging parameters of other skin injuries, including from caustic agents.


Assuntos
Queimaduras/diagnóstico por imagem , Imagem Óptica/métodos , Queimaduras/patologia , Humanos , Pele/patologia , Índices de Gravidade do Trauma
9.
Biomed Opt Express ; 8(12): 5518-5532, 2017 Dec 01.
Artigo em Inglês | MEDLINE | ID: mdl-29296485

RESUMO

A novel approach for time-domain diffuse correlation spectroscopy (TD-DCS) has been recently proposed, which has the unique advantage by simultaneous measurements of optical and dynamical properties in a scattering medium. In this study, analytical models for calculating the time-resolved electric-field autocorrelation function is presented for a multi-layer turbid sample, as well as a semi-infinite medium embedded with a small dynamic heterogeneity. To verify the analytical models, we used Monte Carlo simulations, which demonstrated that the theoretical prediction for the time-resolved autocorrelation function was highly consistent with the Monte Carlo simulation, validating the proposed analytical models. Using these analytical models, we also showed that TD-DCS has a higher sensitivity compared to conventional continuous-wave (CW) DCS for detecting the deeper dynamics. The presented analytical models and simulations can be utilized for quantification of optical and dynamical properties from future TD-DCS experimental data as well as for optimization of the experimental design to achieve maximum contrast for deep tissue dynamics.

10.
Biomed Opt Express ; 8(6): 3045-3052, 2017 Jun 01.
Artigo em Inglês | MEDLINE | ID: mdl-28663925

RESUMO

For prevention and accurate intervention planning, it is crucial to predict if lesions will progress towards cancer. In this study, we investigated the change in optical properties and vascular parameters to characterize skin tissue from mild photodamage to actinic keratosis (AK). Multi-wavelength spatial frequency domain imaging (SFDI) measurements were performed on three patients with clinically normal skin, as well as pre-cancerous actinic keratosis lesions. Our results indicate that there exist significant differences in both optical and vascular parameters between these patients, and that these parameters can be early biomarkers of neoplasia. Ultimately, clinicians can use this noninvasive approach for frequent monitoring of high-risk population.

11.
Sci Rep ; 7(1): 15578, 2017 Nov 14.
Artigo em Inglês | MEDLINE | ID: mdl-29138489

RESUMO

Doxorubicin (Dox) is approved for use in liposomal form for the treatment of ovarian cancer. We previously developed a long-circulating Dox formulation in liposomes containing small amounts of porphyrin-phospholipid, which enables on-demand drug release with near-infrared irradiation. In this study, we present and evaluate a dual-modal, dual-channel light endoscope that allows quantitative reflectance and fluorescence imaging for monitoring of local Dox concentrations in target areas. The endoscope consists of two flexible imaging fibers; one to transmit diagnostic and therapeutic light to the target, and the other to detect fluorescent and reflected light. Thus, the endoscope serves for imaging, for light delivery to trigger drug release, and for monitoring drug concentration kinetics during drug release. We characterized the performance of this endoscope in tissue phantoms and in an in vivo model of ovarian cancer. This study demonstrates the feasibility of non-invasive, quantitative mapping of Dox distribution in vivo via endoscopic imaging.


Assuntos
Diagnóstico por Imagem/métodos , Doxorrubicina/química , Endoscópios , Neoplasias Ovarianas/tratamento farmacológico , Animais , Doxorrubicina/uso terapêutico , Sistemas de Liberação de Medicamentos , Liberação Controlada de Fármacos , Feminino , Humanos , Cinética , Lipossomos/química , Lipossomos/isolamento & purificação , Camundongos , Neoplasias Ovarianas/diagnóstico por imagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA