Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Catheter Cardiovasc Interv ; 96(2): 255-265, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31905259

RESUMO

BACKGROUND: The ULISSE registry evaluated the real-world performance of the Ultimaster® biodegradable polymer sirolimus-eluting stent (BP-SES) in a multicenter-independent cohort of patients undergoing percutaneous coronary intervention, including a large proportion of diabetes mellitus (DM) patients. METHODS: In this subgroup analysis, 1,660 consecutive patients, 2,422 lesions, treated with BP-SES enrolled in the ULISSE registry were divided in two groups: DM (485 patients, 728 lesions) and non-DM (1,175 patients, 1,694 lesions). Primary endpoint was target lesion failure (TLF), a composite endpoint of cardiac-death, target-vessel myocardial infarction (TV-MI), and clinically driven target lesion revascularization (TLR) at 1-year. Secondary endpoint was TLR at 1-year. RESULTS: At 1-year follow-up TLF occurred in 5% overall patients and was significantly higher in DM patients (8 vs. 3.7%; p = .001), due to more cardiac deaths (3.4 vs. 1.1%; p = .002). TLR occurred in 3.2% overall patients, and it was not significantly higher in DM compared to non-DM patients (4.4 vs. 2.8%; p = .114). The incidence of stent thrombosis was low and similar between groups (0.4 vs. 0.9%; p = .526). Insulin-treated DM (ITDM) patients showed higher rate of TLF as compared to non-ITDM patients (13 vs. 6.5%; p = .041), but similar rate of TLR (6 vs. 4%; p = .405). After adjustment for relevant comorbidities, DM was not significantly associated with TLF or cardiac death in patients undergoing BP-SES implantation. CONCLUSIONS: This study is the first all-comers evaluation of BP-SES in DM patients. Our findings show that DM patients, mostly those with ITDM, still represent a vulnerable population and experience significantly higher rate of TLF. Overall BP-SES efficacy is considerable, although not statistically significant higher rate of TLR is still present in DM compared to non-DM patients.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Diabetes Mellitus , Stents Farmacológicos , Intervenção Coronária Percutânea/instrumentação , Sirolimo/administração & dosagem , Idoso , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/mortalidade , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Medição de Risco , Fatores de Risco , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 94(7): 972-979, 2019 12 01.
Artigo em Inglês | MEDLINE | ID: mdl-31037840

RESUMO

BACKGROUND: The ULISSE registry has demonstrated the real-world performance of the Ultimaster biodegradable polymer sirolimus-eluting stent (BP-SES) in a large cohort of patients undergoing percutaneous coronary intervention, including a large proportion of patients presenting with acute myocardial infarction (AMI). METHODS: We performed a subgroup analysis of the ULISSE registry in AMI patients and compared the outcomes of this vulnerable cohort with that of patients presenting without AMI (non-AMI). The primary end point was the incidence of 1-year target lesion failure (TLF), a composite of cardiac death, target vessel myocardial infarction (TV-MI), and clinically indicated target lesion revascularization (TLR). RESULTS: Of 1,660 patients included in the ULISSE registry, 381(23%) presented with AMI, 207(54.3%) non-ST elevation myocardial infarction, and 174(45.7%) ST-elevation myocardial infarction. Compared with non-AMI patients, those with AMI were more frequently female and smokers, with lower left ventricular ejection fraction (LVEF) and chronic kidney disease requiring dialysis. At 1 year, TLF rate was significantly higher in AMI than non-AMI patients (7.9 vs. 4.1%; HR 1.98, CI 95% 1.22-3.23; p = .005) driven by higher rate of cardiac death (4.0 vs. 1.1%; HR 3.59, CI 95% 1.64-7.88; p = .01) and TV-MI (2.8 vs 0.9%; HR 2.99,CI 95% 1.22-7.37; p = .01), without differences in TLR rate (4.3 vs. 2.9%,HR 0.66, CI95% 0.35-1.25; p = .2). At multivariate Cox regression analysis, eGFR <40 mL/min (HR: 2.868) and LVEF <40% (HR: 2.394) were the only independent predictors of TLF. CONCLUSIONS: In AMI patients, Ultimaster BP-SES implantation was associated with higher rate of TLF and definite stent thrombosis compared with non-AMI patients. The high incidence of adverse events was mainly driven by the unfavorable baseline risk profile.


Assuntos
Implantes Absorvíveis , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/terapia , Stents Farmacológicos , Infarto do Miocárdio/terapia , Intervenção Coronária Percutânea/instrumentação , Polímeros/química , Sirolimo/administração & dosagem , Idoso , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Trombose Coronária/etiologia , Feminino , Humanos , Itália , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/diagnóstico por imagem , Infarto do Miocárdio/mortalidade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Intervalo Livre de Progressão , Desenho de Prótese , Recidiva , Sistema de Registros , Estudos Retrospectivos , Fatores de Risco , Sirolimo/efeitos adversos , Fatores de Tempo
3.
Int J Cardiol ; 290: 52-58, 2019 09 01.
Artigo em Inglês | MEDLINE | ID: mdl-30917900

RESUMO

BACKGROUND: This study aimed to evaluate real-world clinical outcome of patients needing short dual antiplatelet therapy (S-DAPT) following PCI with Ultimaster® thin-strut, biodegradable polymer sirolimus-eluting stent (BP-SES), which was supposed to induce faster stent endothelialization and reduce device thrombogenicity. METHODS: In this sub-group analysis of patients enrolled in the ULISSE registry, two groups were identified: 1) patients discharged with S-DAPT (≤3-month) due to high bleeding risk or need for urgent major non-cardiac surgery and 2) patients discharged with recommended DAPT (R-DAPT) duration (≥6-month). The primary ischemic-safety and bleeding-safety endpoints were TLF (composite of cardiac-death, target vessel MI, and clinically driven target lesion revascularization), and BARC major bleedings (≥type-3a) at 1-year follow-up. To account for events occurring before DAPT discontinuation we performed 3-month landmark analysis. RESULTS: 82 patients (5%) were discharged with ≤3-month DAPT (57 ±â€¯27 days), and 1558 patients (94%) were discharged with ≥6-month DAPT (318 ±â€¯75 days). No significant differences between S-DAPT and R-DAPT group were observed in TLF at 1-year (7.9% vs. 4.6%). The rate of BARC major bleeding resulted significantly higher in S-DAPT group (3.9% vs. 0.3%; p = 0.001), with the majority of bleeding events occurring within 3 months. The landmark analysis showed no significant differences in BARC major bleedings between groups (1.4% vs. 0.3%; p = 0.142). CONCLUSIONS: As compared to those treated with R-DAPT (≥6-month), patients needing -S-DAPT (≤3-month) after PCI with Ultimaster® BP-SES had similar rates of 1-year TLF and BARC major bleedings following early DAPT discontinuation.


Assuntos
Implantes Absorvíveis/tendências , Síndrome Coronariana Aguda/terapia , Stents Farmacológicos/tendências , Inibidores da Agregação Plaquetária/administração & dosagem , Sistema de Registros , Sirolimo/administração & dosagem , Síndrome Coronariana Aguda/diagnóstico por imagem , Síndrome Coronariana Aguda/epidemiologia , Idoso , Idoso de 80 Anos ou mais , Seguimentos , Humanos , Imunossupressores/administração & dosagem , Itália/epidemiologia , Pessoa de Meia-Idade , Polímeros , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
4.
Int J Cardiol ; 260: 36-41, 2018 06 01.
Artigo em Inglês | MEDLINE | ID: mdl-29622449

RESUMO

BACKGROUND: This study was designed to confirm in a large population of unselected patients the promising results of Ultimaster® biodegradable polymer sirolimus-eluting stent (BP-SES) already shown in previous trial. METHODS: ULISSE is an observational, multicenter, national registry evaluating all patients undergoing PCI with the Ultimaster® BP-SES. Incidence of 1-year TLF (cardiac death or target vessel MI or clinically indicated TLR) was the primary endpoint. Pre-specified subgroup analysis was performed for diabetic patients and for those with lesion longer than 25 mm, bifurcation and CTO lesions. RESULTS: 1660 patients were enrolled in 9 Italian cardiology centers, 82% were males, mean age of 68 ±â€¯10 years, and 29% were diabetics. Overall 2422 lesions were treated, 65% type B2/C lesions, 7% CTOs, 17% bifurcations and 38% long lesions. The incidence of 1-year TLF was 5%, with 3.2% of clinically indicated TLR. TLF occurred in 8% of the patients with diabetes mellitus, and 7% in bifurcation, 6.7% in CTO and 6.2% in long lesions. Definite overall ST was 0.9%, and 1.2% in patients treated for type B2/C lesions. Multivariate logistic regression analysis identified stenting on unprotected LMT (OR = 4.80), stenting on ISR lesion (OR = 3.19) and need for rotational atherectomy (OR = 6.24) as the strongest independent predictors of TLF. CONCLUSIONS: The results of this national all-comers registry show that the Ultimaster® BP-SES real-world performance was comparable with that observed in the clinical trial, with low rate of primary endpoint and TLR. Long term follow-up will be necessary to prove the theoretical advantage of the BP-SES over time.


Assuntos
Implantes Absorvíveis/tendências , Stents Farmacológicos/tendências , Vigilância da População , Sistema de Registros , Sirolimo/administração & dosagem , Idoso , Antibacterianos/administração & dosagem , Morte , Feminino , Seguimentos , Cardiopatias/diagnóstico , Cardiopatias/mortalidade , Cardiopatias/cirurgia , Humanos , Itália/epidemiologia , Masculino , Pessoa de Meia-Idade , Vigilância da População/métodos , Estudos Retrospectivos , Fatores de Tempo , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA