Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 39
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Appl Clin Med Phys ; 23(12): e13777, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-36125203

RESUMO

Entry into the field of clinical medical physics is most commonly accomplished through the completion of a Commission on Accreditation of Medical Physics Educational Programs (CAMPEP)-accredited graduate and residency program. To allow a mechanism to bring valuable expertise from other disciplines into clinical practice in medical physics, an "alternative pathway" approach was also established. To ensure those trainees who have completed a doctoral degree in physics or a related discipline have the appropriate background and didactic training in medical physics, certificate programs and a CAMPEP-accreditation process for these programs were initiated. However, medical physics-specific didactic, research, and clinical exposure of those entering medical physics residencies from these certificate programs is often comparatively modest when evaluated against individuals holding Master's and/or Doctoral degrees in CAMPEP-accredited graduate programs. In 2016, the AAPM approved the formation of Task Group (TG) 298, "Alternative Pathway Candidate Education and Training." The TG was charged with reviewing previous published recommendations for alternative pathway candidates and developing recommendations on the appropriate education and training of these candidates. This manuscript is a summary of the AAPM TG 298 report.


Assuntos
Educação Médica , Internato e Residência , Radioterapia (Especialidade) , Humanos , Física Médica/educação , Competência Clínica , Educação de Pós-Graduação em Medicina
2.
J Appl Clin Med Phys ; 23(3): e13554, 2022 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-35128786

RESUMO

PURPOSE: Medical physics residents (MPRs) will define and shape the future of physics in medicine. We sought to better understand the residency experience, as related to resilience and well-being, through the lens of current MPRs and medical physicists (MPs) working with residents. METHODS AND MATERIALS: From February-May 2019, we conducted 32, 1-h, confidential, semi-structured interviews with MPs either currently enrolled in an accredited residency (n = 16) or currently employed by a department with an accredited residency (n = 16). Interviews centered on the topics of mentorship, work/life integration, and discrimination. Qualitative analysis methods were used to derive key themes from the interview transcripts. RESULTS: With regard to the medical physics residency experience, four key themes emerged during qualitative analysis: the demanding nature of medical physics residencies, the negative impacts of residency on MPRs during training and beyond, strategies MPRs use to cope with residency stress, and the role of professional societies in addressing residency-related change. CONCLUSIONS: Residency training is a stress-inducing time in the path to becoming a board-certified MP. By uncovering several sources of this stress, we have identified opportunities to support the resiliency and well-being of MPs in training through recommendations by professional societies, programmatic changes, and interventions at the department and residency program director level for residency programs, as well as strategies that MPRs themselves can use to support well-being on their career journey.


Assuntos
Internato e Residência , Humanos , Mentores , Física
3.
J Appl Clin Med Phys ; 21(7): 11-15, 2020 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-31800151

RESUMO

The American Association of Physicists in Medicine (AAPM) is a nonprofit professional society whose primary purposes are to advance the science, education and professional practice of medical physics. The AAPM has more than 8,000 members and is the principal organization of medical physicists in the United States. The AAPM will periodically define new practice guidelines for medical physics practice to help advance the science of medical physics and to improve the quality of service to patients throughout the United States. Existing medical physics practice guidelines will be reviewed for the purpose of revision or renewal, as appropriate, on their fifth anniversary or sooner. Each medical physics practice guideline represents a policy statement by the AAPM, has undergone a thorough consensus process in which it has been subjected to extensive review, and requires the approval of the Professional Council. The medical physics practice guidelines recognize that the safe and effective use of diagnostic and therapeutic radiology requires specific training, skills, and techniques, as described in each document. Reproduction or modification of the published practice guidelines and technical standards by those entities not providing these services is not authorized. The following terms are used in the AAPM practice guidelines: Must and Must Not: Used to indicate that adherence to the recommendation is considered necessary to conform to this practice guideline. Should and Should Not: Used to indicate a prudent practice to which exceptions may occasionally be made in appropriate circumstances. Approved by AAPM's Executive Committee May 28, 2019.


Assuntos
Física Médica , Radioterapia (Especialidade) , Humanos , Sociedades , Estados Unidos
4.
J Appl Clin Med Phys ; 18(6): 275-287, 2017 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-29125231

RESUMO

PURPOSE: The education and training landscape has been profoundly reshaped by the ABR 2012/2014 initiative and the MedPhys Match. This work quantifies these changes and summarizes available reports, surveys, and statistics on education and training. METHODS: We evaluate data from CAMPEP-accredited program websites, annual CAMPEP graduate and residency program reports, and surveys on the MedPhys Match and Professional Doctorate degree (DMP). RESULTS: From 2009-2015, the number of graduates from CAMPEP-accredited graduate programs rose from 210 to 332, while CAMPEP-accredited residency positions rose from 60 to 134. We estimate that approximately 60% of graduates of CAMPEP-accredited graduate programs intend to enter clinical practice, however, only 36% of graduates were successful in acquiring a residency position in 2015. The maximum residency placement percentage for a graduate program is 70%, while the median for all programs is only 22%. Overall residency placement percentage for CAMPEP-accredited program graduates from 2011-2015 was approximately 38% and 25% for those with a PhD and MS, respectively. The disparity between the number of clinically oriented graduates and available residency positions is perceived as a significant problem by over 70% of MedPhys Match participants responding to a post-match survey. Approximately 32% of these respondents indicated that prior knowledge of this situation would have changed their decision to pursue graduate education in medical physics. CONCLUSION: These data reveal a substantial disparity between the number of residency training positions and graduate students interested in these positions, and a substantial variability in residency placement percentage across graduate programs. Comprehensive data regarding current and projected supply and demand within the medical physics workforce are needed for perspective on these numbers. While the long-term effects of changes in the education and training infrastructure are still unclear, available survey data suggest that these changes could negatively affect potential entrants to the profession.


Assuntos
Competência Clínica , Educação de Pós-Graduação em Medicina/métodos , Física Médica/educação , Internato e Residência/normas , Radioterapia (Especialidade)/educação , Credenciamento , Avaliação Educacional , Humanos
5.
J Oral Maxillofac Surg ; 74(12): 2557-2566, 2016 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-27424068

RESUMO

Epidemiologic data have shown changes in the demographic profile of patients presenting with oral cavity squamous cell carcinoma (SCC) during the past 4 decades. In particular, there has been a marked increase in the number of young women without a history of smoking presenting with SCC of the tongue. A Surveillance, Epidemiology, and End Results review of patients with head and neck cancer identified 5.3% younger than 40 years. After comparing cohorts from 1973 to 1984 with 1985 to 1997, a 60% increase in tongue cancer in patients younger 40 years was noted. Epidemiologic data also have shown that women are tending to delay childbearing to an older age. These 2 factors have resulted in an increasing prevalence of cancer diagnosed during pregnancy. If current trends continue, oral surgeons and maternal fetal medicine obstetric specialists will see an increasing number of pregnant patients presenting with malignancies. This in turn will lead to a number of complex surgical and adjuvant treatment considerations resulting in ethical and moral decisions for which limited data exist to guide best practice. The treatment chosen will affect not only the health of the patient, but also the health of the fetus and ongoing pregnancy. This report describes the case of a woman who was diagnosed with SCC of the tongue at 14 weeks' gestational age. This report presents her treatment course and a review of the literature to support her decisions related to the care given.


Assuntos
Carcinoma de Células Escamosas , Complicações Neoplásicas na Gravidez , Neoplasias da Língua , Adulto , Carcinoma de Células Escamosas/diagnóstico , Carcinoma de Células Escamosas/terapia , Quimiorradioterapia Adjuvante , Feminino , Glossectomia , Humanos , Gravidez , Complicações Neoplásicas na Gravidez/diagnóstico , Complicações Neoplásicas na Gravidez/terapia , Neoplasias da Língua/diagnóstico , Neoplasias da Língua/terapia
6.
J Appl Clin Med Phys ; 17(5): 34-46, 2016 09 08.
Artigo em Inglês | MEDLINE | ID: mdl-27685109

RESUMO

To create a comprehensive dataset of peripheral dose (PD) measurements from a new generation of linear accelerators with and without the presence of a newly designed fetal shield, PD measurements were performed to evaluate the effects of depth, field size, distance from the field edge, collimator angle, and beam modi-fiers for common treatment protocols and modalities. A custom fetal lead shield was designed and made for our department that allows external beam treatments from multiple angles while minimizing the need to adjust the shield during patient treatments. PD measurements were acquired for a comprehensive series of static fields on a stack of Solid Water. Additionally, PDs from various clinically relevant treatment scenarios for pregnant patients were measured using an anthropomorphic phantom that was abutted to a stack of Solid Water. As expected, the PD decreased as the distance from the field edge increased and the field size decreased. On aver-age, a PD reduction was observed when a 90° collimator rotation was applied and/or when the tertiary MLCs and jaws defined the field aperture. However, the effect of the collimator rotation (90° versus 0°) in PD reduction was not found to be clini-cally significant when the tertiary MLCs were used to define the field aperture. In the presence of both the MLCs and the fetal shield, the PD was reduced by 58% at a distance of 10 cm from the field edge. The newly designed fetal shield may effectively reduce fetal dose and is relatively easy to setup. Due to its design, we are able to use a broad range of treatment techniques and beam angles. We believe the acquired comprehensive PD dataset collected with and without the fetal shield will be useful for treatment teams to estimate fetal dose and help guide decisions on treat-ment techniques without the need to perform pretreatment phantom measurements.


Assuntos
Feto/efeitos da radiação , Neoplasias/radioterapia , Imagens de Fantasmas , Lesões por Radiação/prevenção & controle , Proteção Radiológica/instrumentação , Feminino , Humanos , Gravidez , Dosagem Radioterapêutica , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia de Intensidade Modulada/métodos , Espalhamento de Radiação
7.
J Appl Clin Med Phys ; 16(1): 5189, 2015 Jan 08.
Artigo em Inglês | MEDLINE | ID: mdl-25679176

RESUMO

A formal communication process was established and evaluated for the management of patients with cardiac implantable electronic devices (CIEDs) receiving radiation therapy (RT). Methods to estimate dose to the CIED were evaluated for their appropriateness in the management of these patients. A retrospective, institutional review board (IRB) approved study of 69 patients with CIEDs treated with RT between 2005 and 2011 was performed. The treatment sites, techniques, and the estimated doses to the CIEDs were analyzed and compared to estimates from published peripheral dose (PD) data and three treatment planning systems(TPSs) - UMPlan, Eclipse's AAA and Acuros algorithms. When measurements were indicated, radiation doses to the CIEDs ranged from 0.01-5.06 Gy. Total peripheral dose estimates based on publications differed from TLD measurements by an average of 0.94 Gy (0.05-4.49 Gy) and 0.51 Gy (0-2.74 Gy) for CIEDs within 2.5 cm and between 2.5 and 10 cm of the treatment field edge, respectively. Total peripheral dose estimates based on three TPSs differed from measurements by an average of 0.69 Gy (0.02-3.72 Gy) for CIEDs within 2.5 cm of the field edge. Of the 69 patients evaluated in this study, only two with defibrillators experienced a partial reset of their device during treatment. Based on this study, few CIED-related events were observed during RT. The only noted correlation with treatment parameters for these two events was beam energy, as both patients were treated with high-energy photon beams (16 MV). Differences in estimated and measured CIED doses were observed when using published PD data and TPS calculations. As such, we continue to follow conservative guidelines and measure CIED doses when the device is within 10 cm of the field or the estimated dose is greater than 2 Gy for pacemakers or 1 Gy for defibrillators.


Assuntos
Desfibriladores Implantáveis , Marca-Passo Artificial , Radioterapia de Intensidade Modulada/métodos , Neoplasias Torácicas/radioterapia , Algoritmos , Análise de Falha de Equipamento , Humanos , Fótons/uso terapêutico , Radiometria , Dosagem Radioterapêutica , Estudos Retrospectivos
8.
J Appl Clin Med Phys ; 16(6): 490-500, 2015 11 08.
Artigo em Inglês | MEDLINE | ID: mdl-26699556

RESUMO

We present an institutional experience on the clinical implementation of magnetic resonance (MR)-guided vaginal brachytherapy using commercially available solid applicator models. To test the fidelity of solid applicator models to digitize vaginal cylinder applicators, three datasets were evaluated. The first included 15 patients who were simulated with CT alone. Next, a water phantom was used to evaluate vaginal cylinders ranging from 20 to 35 mm in diameter with CT and MR. Finally, three patients undergoing HDR brachytherapy with vaginal cylinders that were simulated with both CT and MR were evaluated. In these assessments, the solid applicator models were aligned based on the outline of the applicators on the corresponding volumetric image, and deviations between the central source positions defined based on X-ray markers (on CT) and solid applicator models (on CT and MR), and the percent dose difference between select reference points were calculated. The mean central source deviation defined based on X-ray markers (on CT) and solid applicator models (on CT and MR) for the 15-patient cohort, the phantom, and the 3-patient cohort is 0.6 mm, 0.6 mm, and 1.2 mm, respectively. The average absolute percent dose difference for the bladder, rectum, prescription, and inferior reference points were 2.2%, 2.3%, 2.2%, and 2.4%, respectively, for the 15 patient cohort. For the phantom study, the average, absolute percent dose difference for the prescription and inferior reference points are 2.0% and 2.1% for the CT, 2.3% and 2.2% for the T1W, and 2.8% and 3.0% for the T2W images. For the three patient cohort, the average absolute percent dose difference for the bladder, rectum, prescription, and inferior reference points are 2.9%, 2.6%, 3.0%, and 4.2% for the CT, 6.5%, 1.6%, 2.5%, and 4.7% for the T1W, and 6.0%, 7.4%, 2.6, and 2.0% for the T2W images. Based on the current study, aligning the applicator model to MR images provides a practical, efficient approach to perform MR-based brachytherapy planning.


Assuntos
Braquiterapia/instrumentação , Imageamento por Ressonância Magnética/métodos , Planejamento da Radioterapia Assistida por Computador/métodos , Radioterapia Guiada por Imagem/métodos , Braquiterapia/métodos , Estudos de Coortes , Neoplasias do Endométrio/diagnóstico por imagem , Neoplasias do Endométrio/patologia , Neoplasias do Endométrio/radioterapia , Feminino , Humanos , Imageamento Tridimensional/métodos , Imagens de Fantasmas , Tomografia Computadorizada por Raios X , Vagina
9.
J Appl Clin Med Phys ; 15(1): 4520, 2014 Jan 06.
Artigo em Inglês | MEDLINE | ID: mdl-24423851

RESUMO

Primary peritoneal clear cell carcinoma (PP-CCC), which is a rare tumor with poor prognosis, is typically managed with surgery and/or chemotherapy. We present a unique treatment approach for a patient with a pelvic PP-CCC, consisting of postchemotherapy intensity-modulated radiation therapy (IMRT) followed by interstitial high-dose-rate (HDR) brachytherapy. A 54-year-old female with an inoperable pelvic-supravaginal 5.6 cm T3N0M0 PP-CCC tumor underwent treatment with 6 cycles of carboplatin and taxol chemotherapy. Postchemotherapy PET/CT scan revealed a residual 3.3 cm tumor. The patient underwent CT and MR planning simulation, and was treated with 50 Gy to the primary tumor and 45 Gy to the pelvis including the pelvic lymph nodes, using IMRT to spare bowel. Subsequently, the patient was treated with an interstitial HDR brachytherapy implant, planned using both CT and MR scans. A total dose of 15 Gy in 5 Gy fractions over two days was delivered with Ir-192 HDR brachytherapy. The total prescribed equivalent 2 Gy dose (EQD2) to the HDR planning target volume (PTV) from both the EBRT and HDR treatments ranged between 63 and 68.8 Gy2 due to differential dosing of the primary and pelvic targets. The patient tolerated radiotherapy well, except for mild diarrhea not requiring medication. There was no patient-reported acute toxicity one month following the radiotherapy course. At four months following adjuvant radiation therapy, the patient had near complete resolution of local tumor on PET/CT without any radiation-associated toxicity. However, the patient was noted to have metastatic disease outside of the radiation field, specifically lesions in the liver and bone. This case report illustrates the feasibility of the treatment of a pelvic PP-CCC with IMRT followed by interstitial HDR brachytherapy boost, which resulted in near complete local tumor response without significant morbidity.


Assuntos
Adenocarcinoma de Células Claras/radioterapia , Braquiterapia , Fracionamento da Dose de Radiação , Neoplasias Peritoneais/radioterapia , Planejamento da Radioterapia Assistida por Computador , Radioterapia de Intensidade Modulada , Estudos de Viabilidade , Feminino , Seguimentos , Humanos , Linfonodos/efeitos da radiação , Pessoa de Meia-Idade , Órgãos em Risco , Pelve/efeitos da radiação , Tomografia por Emissão de Pósitrons , Prognóstico , Radioterapia Conformacional , Tomografia Computadorizada por Raios X
11.
J Appl Clin Med Phys ; 15(3): 4763, 2014 May 08.
Artigo em Inglês | MEDLINE | ID: mdl-24892354

RESUMO

There is a clear need for established standards for medical physics residency training. The complexity of techniques in imaging, nuclear medicine, and radiation oncology continues to increase with each passing year. It is therefore imperative that training requirements and competencies are routinely reviewed and updated to reflect the changing environment in hospitals and clinics across the country. In 2010, the AAPM Work Group on Periodic Review of Medical Physics Residency Training was formed and charged with updating AAPM Report Number 90. This work group includes AAPM members with extensive experience in clinical, professional, and educational aspects of medical physics. The resulting report, AAPM Report Number 249, concentrates on the clinical and professional knowledge needed to function independently as a practicing medical physicist in the areas of radiation oncology, imaging, and nuclear medicine, and constitutes a revision to AAPM Report Number 90. This manuscript presents an executive summary of AAPM Report Number 249.


Assuntos
Guias como Assunto , Física Médica/educação , Física Médica/normas , Internato e Residência/normas , Medicina Nuclear/educação , Radioterapia (Especialidade)/educação , Radiologia/educação , Currículo/normas , Medicina Nuclear/normas , Radioterapia (Especialidade)/normas , Radiologia/normas , Estados Unidos
12.
J Appl Clin Med Phys ; 14(6): 4476, 2013 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-24257289

RESUMO

Medical physicists are often involved in the didactic training of graduate students, residents (both physics and physicians), and technologists. As part of continuing medical education, we are also involved in maintenance of certification projects to assist in the education of our peers. As such, it is imperative that we remain current concerning available educational resources. Medical physics journals offer book reviews, allowing us an opportunity to learn about newly published books in the field. A similar means of communication is not currently available for online educational resources. This information is conveyed through informal means. This review presents a summary of online resources available to the medical physics community that may be useful for educational purposes.


Assuntos
Instrução por Computador , Física Médica/educação , Internet , Radiologia/educação , Humanos
13.
J Appl Clin Med Phys ; 14(6): 4728, 2013 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-24257293

RESUMO

The AAPM has long advocated a consistent level of medical physics practice, and has published many recommendations and position statements toward that goal, such as Science Council Task Group reports related to calibration and quality assurance, Education Council and Professional Council Task Group reports related to education, training, and peer review, and Board-approved Position Statements related to the Scope of Practice, physicist qualifications, and other aspects of medical physics practice. Despite these concerted and enduring efforts, the profession does not have clear and concise statements of the acceptable practice guidelines for routine clinical medical physics. As accreditation of clinical practices becomes more common, Medical Physics Practice Guidelines (MPPGs) will be crucial to ensuring a consistent benchmark for accreditation programs. To this end, the AAPM has recently endorsed the development of MPPGs, which may be generated in collaboration with other professional societies. The MPPGs are intended to be freely available to the general public. Accrediting organizations, regulatory agencies, and legislators will be encouraged to reference these MPPGs when defining their respective requirements. MPPGs are intended to provide the medical community with a clear description of the minimum level of medical physics support that the AAPM would consider prudent in clinical practice settings. Support includes, but is not limited to, staffing, equipment, machine access, and training. These MPPGs are not designed to replace extensive Task Group reports or review articles, but rather to describe the recommended minimum level of medical physics support for specific clinical services. This article has described the purpose, scope, and process for the development of MPPGs.


Assuntos
Competência Clínica , Física Médica/educação , Física Médica/normas , Guias de Prática Clínica como Assunto/normas , Radioterapia (Especialidade)/normas , Humanos
14.
Acad Radiol ; 30 Suppl 2: S202-S210, 2023 09.
Artigo em Inglês | MEDLINE | ID: mdl-37100674

RESUMO

RATIONALE AND OBJECTIVES: Most women with endometrial cancer (EC) have an excellent prognosis and may be cured. However, treatment-related pelvic functional impacts may affect long-term quality of life. To better understand these concerns, we explored correlations between patient-reported outcomes and pelvic magnetic resonance imaging (MRI) features in women treated for EC. MATERIALS AND METHODS: Women with histologic diagnosis of EC were consented preoperatively and completed the validated Female Sexual Function Index (FSFI) and Pelvic Floor Dysfunction Index (PFDI) questionnaires at preoperative, 6-week, and 6-month follow-up visits. Pelvic MRIs with dynamic pelvic floor sequences were performed at 6 weeks and 6 months. RESULTS: A total of 33 women participated in this prospective pilot study. Only 53.7% had been asked about sexual function by providers while 92.4% thought they should have been. Sexual function became more important to women over time. Baseline FSFI was low, declined at 6 weeks, and climbed above baseline at 6 months. Hyperintense vaginal wall signal on T2-weighted images (10.9 vs. 4.8, p = .002) and intact Kegel function (9.8 vs. 4.8, p = .03) were associated with higher FSFI. PFDI scores trended toward improved pelvic floor function over time. Pelvic adhesions on MRI were associated with better pelvic floor function (23.0 vs. 54.9, p = .003). Urethral hypermobility (48.4 vs. 21.7, p = .01), cystocele (65.6 vs. 24.8, p < .0001), and rectocele (58.8 vs. 18.8, p < .0001) predicted worse pelvic floor function. CONCLUSION: Use of pelvic MRI to quantify anatomic and tissue changes may facilitate risk stratification and response assessment for pelvic floor and sexual dysfunction. Patients articulated the need for attention to these outcomes during EC treatment.


Assuntos
Neoplasias do Endométrio , Qualidade de Vida , Feminino , Humanos , Estudos Prospectivos , Projetos Piloto , Imageamento por Ressonância Magnética , Neoplasias do Endométrio/diagnóstico por imagem , Neoplasias do Endométrio/cirurgia , Medidas de Resultados Relatados pelo Paciente , Inquéritos e Questionários
16.
Med Phys ; 49(8): e983-e1023, 2022 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-35662032

RESUMO

The task group (TG) on magnetic resonance imaging (MRI) implementation in high-dose-rate (HDR) brachytherapy (BT)-Considerations from simulation to treatment, TG 303, was constituted by the American Association of Physicists in Medicine's (AAPM's) Science Council under the direction of the Therapy Physics Committee, the Brachytherapy Subcommittee, and the Working Group on Brachytherapy Clinical Applications. The TG was charged with developing recommendations for commissioning, clinical implementation, and on-going quality assurance (QA). Additionally, the TG was charged with describing HDR BT workflows and evaluating practical consideration that arise when implementing MR imaging. For brevity, the report is focused on the treatment of gynecologic and prostate cancer. The TG report provides an introduction and rationale for MRI implementation in BT, a review of previous publications on topics including available applicators, clinical trials, previously published BT-related TG reports, and new image-guided recommendations beyond CT-based practices. The report describes MRI protocols and methodologies, including recommendations for the clinical implementation and logical considerations for MR imaging for HDR BT. Given the evolution from prescriptive to risk-based QA, an example of a risk-based analysis using MRI-based, prostate HDR BT is presented. In summary, the TG report is intended to provide clear and comprehensive guidelines and recommendations for commissioning, clinical implementation, and QA for MRI-based HDR BT that may be utilized by the medical physics community to streamline this process. This report is endorsed by the American Brachytherapy Society.


Assuntos
Braquiterapia , Neoplasias da Próstata , Braquiterapia/métodos , Humanos , Imageamento por Ressonância Magnética/métodos , Masculino , Próstata , Neoplasias da Próstata/diagnóstico por imagem , Neoplasias da Próstata/radioterapia , Dosagem Radioterapêutica , Estados Unidos
17.
J Appl Clin Med Phys ; 12(3): 3398, 2011 Apr 22.
Artigo em Inglês | MEDLINE | ID: mdl-21844848

RESUMO

The purpose of this study was to determine the dosimetric impact of density variations observed in water-equivalent solid slabs. Measurements were performed using two 30 cm × 30 cm water-equivalent slabs, one being 4 cm think and the other 5 cm thick. The location and extent of density variations were determined by computed tomography (CT) scans. Additional imaging measurements were made with an amorphous silicon megavoltage portal imaging device and an ultrasound unit. Dosimetric measurements were conducted with a 2D ion chamber array, and a scanned diode in water. Additional measurements and calculations were made of small rectilinear void inhomogeneities formed with water-equivalent slabs, using a 2D ion chamber array and the convolution superposition algorithm. Two general types of density variation features were observed on CT images: 1) regions of many centimeters across, but typically only a few millimeters thick, with electron densities a few percent lower than the bulk material, and 2) cylindrical regions roughly 0.2 cm in diameter and up to 20 cm long with electron densities up to 5% lower than the surrounding material. The density variations were not visible on kilovoltage, megavoltage or ultrasound images. The dosimetric impact of the density variations were not detectable to within 0.1% using the 2D ion chamber array or the scanning photon diode at distances 0.4 cm to 2 cm beyond the features. High-resolution dosimetric calculations using the convolution-superposition algorithm with density corrections enabled on CT-based datasets showed no discernable dosimetric impact. Calculations and measurements on simulated voids place the upper limit on possible dosimetric variations from observed density variations at much less than 0.6%. CT imaging of water-equivalent slabs may reveal density variations which are otherwise unobserved with kV, MV, or ultrasound imaging. No dosimetric impact from these features was measureable with an ion chamber array or scanned photon diode. Consequently, they were determined to be acceptable for all clinical use.


Assuntos
Fótons , Radiometria/métodos , Água/química , Algoritmos , Humanos , Íons , Imagens de Fantasmas , Efeitos da Radiação , Radiometria/instrumentação , Radioterapia de Alta Energia , Silício/química , Tomografia Computadorizada por Raios X , Ultrassonografia , Ecrans Intensificadores para Raios X
18.
Adv Radiat Oncol ; 6(5): 100724, 2021.
Artigo em Inglês | MEDLINE | ID: mdl-34278052

RESUMO

PURPOSE: To generate an understanding of the primary concerns facing medical physicists regarding integration of a demanding technical career with their personal lives. METHODS AND MATERIALS: In 2019, we recruited 32 medical physics residents, faculty, and staff via emails to US medical physics residency program directors to participate in a 1-hour, semistructured interview that elicited their thoughts on several topics, including work-life integration. Standard techniques of qualitative thematic analysis were used to generate the research findings. RESULTS: Of the participants, 50% were women and 69% were non-Hispanic White individuals, with a mean (SD) age of 37.5 (7.4) years. They were evenly split between residents and faculty or staff. Participant responses centered around 5 primary themes: the gendered distribution of household responsibilities, the effect of career or work on home and family life, the effect of family on career or work, support and strategies for reconciling work-life conflicts, and the role of professional societies in addressing work-life integration. Participants expressed concern about the effect of heavy workloads on home life, with female respondents more likely to report carrying the majority of the household burden. CONCLUSIONS: Medical physicists experience challenges in managing work-life conflict amid a diverse array of personal and professional responsibilities. Further investigations are needed to quantitatively assess the division of work and household labor by gender in medical physics, particularly after the outbreak of the COVID-19 pandemic, but this study's qualitative findings suggest that the profession should consider ways to address root causes of work-life conflict to promote the future success and well-being of all medical physicists, and perhaps women in particular.

19.
Semin Radiat Oncol ; 30(1): 29-38, 2020 01.
Artigo em Inglês | MEDLINE | ID: mdl-31727297

RESUMO

An interstitial brachytherapy approach for gynecologic cancers is typically considered for patients with lesions exceeding 5 mm within tissue or that are not easily accessible for intracavitary applications. Recommendations for treating gynecologic malignancies with this approach are available through the American Brachytherapy Society, but vary based on available resources, staffing, and logistics. The intent of this manuscript is to share the collective experience of 3 academic centers that routinely perform interstitial gynecologic brachytherapy. Discussion points include indications for interstitial implants, procedural preparations, applicator selection, anesthetic options, imaging, treatment planning objectives, clinical workflows, timelines, safety, and potential challenges. Interstitial brachytherapy is a complex, high-skill procedure requiring routine practice to optimize patient safety and treatment efficacy. Clinics planning to implement this approach into their brachytherapy practice may benefit from considering the discussion points shared in this manuscript.


Assuntos
Braquiterapia/métodos , Neoplasias dos Genitais Femininos/radioterapia , Braquiterapia/instrumentação , Feminino , Neoplasias dos Genitais Femininos/patologia , Humanos , Imageamento por Ressonância Magnética , Guias de Prática Clínica como Assunto , Dosagem Radioterapêutica , Tomografia Computadorizada por Raios X , Estados Unidos , Fluxo de Trabalho
20.
Brachytherapy ; 19(3): 355-361, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32249182

RESUMO

PURPOSE: To present on the commissioning of an automated brachytherapy plan checker (BPC) for the evaluation of high-dose-rate brachytherapy treatment plans in support of standardized workflows and patient safety. METHODS AND MATERIALS: A BPC was developed using an applications programming interface in a commercial treatment planning system based on different inputs (e.g., regulations, professional society recommendations, and user feedback) and leveraged our experience with an in-house developed external beam plan checker. The BPC was commissioned using a comprehensive suite of test plans with known errors and anonymized clinical plans. RESULTS: During commissioning, the BPC was successfully executed on a total of 87 test plans. Commissioning tests spanned a range of treatment sites and evaluated that pass and fail states were correct. Administration settings were changed in a nonclinical database to evaluate tests involving the source and afterloader. Clinical testing of the BPC was then performed in parallel with a manual review process before clinical implementation. CONCLUSIONS: To commission the BPC for clinical use, a comprehensive suite of test plans was developed and used to ensure the BPC correctly detected and reported errors. A summary of the test plans is presented to help guide users developing similar automated tools. The BPC represents a process-improvement initiative designed to reduce errors and improve safety for brachytherapy patients. By using a comprehensive test suite for commissioning, tests are available for periodic quality assurance and after software upgrades.


Assuntos
Braquiterapia , Planejamento da Radioterapia Assistida por Computador , Software/normas , Humanos , Dosagem Radioterapêutica
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA