Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 18 de 18
Filtrar
1.
J Gen Intern Med ; 37(9): 2308-2313, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35713808

RESUMO

BACKGROUND: Point-of-care ultrasound (POCUS) training has been increasing among internal medicine (IM) residency programs, but few programs can provide longitudinal training due to barriers such as lack of trained faculty. AIM: Describe the development of a longitudinal POCUS track for IM residents using local and external resources, including a national POCUS certificate program. SETTING: University-based IM residency program affiliated with a public and veterans affairs hospital. PARTICIPANTS: Twelve IM residents from 2018 to 2021. PROGRAM DESCRIPTION: Residents complete a national POCUS certificate program by attending live courses and completing online modules, an image portfolio, and final knowledge/skills assessments. Locally, residents participate in 1-month procedure and diagnostic POCUS rotations and provide peer-to-peer POCUS teaching of residents and medical students. PROGRAM EVALUATION: The POCUS track increased residents' use and comfort with diagnostic and procedural applications. All residents rated being satisfied or very satisfied with the track and would recommend it to prospective applicants (100%). The most commonly reported barriers to utilizing POCUS per residents were time constraints (83%), lack of available ultrasound equipment (83%), and lack of trained faculty (58%). DISCUSSION: IM residency programs with limited faculty expertise in POCUS can leverage external resources to provide longitudinal POCUS training to its residents.


Assuntos
Internato e Residência , Estudantes de Medicina , Humanos , Sistemas Automatizados de Assistência Junto ao Leito , Estudos Prospectivos , Ultrassonografia/métodos
2.
J Infect Dis ; 220(3): 514-523, 2019 07 02.
Artigo em Inglês | MEDLINE | ID: mdl-30923818

RESUMO

As we age, there is an increased risk for the development of tuberculosis (TB) caused by Mycobacterium tuberculosis (Mtb) infection. Few studies consider that age-associated changes in the alveolar lining fluid (ALF) may increase susceptibility by altering soluble mediators of innate immunity. We assessed the impact of adult or elderly human ALF during Mtb infection in vitro and in vivo. We identified amplification of pro-oxidative and proinflammatory pathways in elderly ALF and decreased binding capability of surfactant-associated surfactant protein A (SP-A) and surfactant protein D (SP-D) to Mtb. Human macrophages infected with elderly ALF-exposed Mtb had reduced control and fewer phagosome-lysosome fusion events, which was reversed when elderly ALF was replenished with functional SP-A/SP-D. In vivo, exposure to elderly ALF exacerbated Mtb infection in young mice. Our studies demonstrate how the pulmonary environment changes as we age and suggest that Mtb may benefit from declining host defenses in the lung mucosa of the elderly.


Assuntos
Pulmão/imunologia , Pulmão/microbiologia , Mucosa Respiratória/imunologia , Mucosa Respiratória/microbiologia , Tuberculose/imunologia , Adolescente , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Imunidade Inata/imunologia , Inflamação/imunologia , Inflamação/microbiologia , Lisossomos/imunologia , Lisossomos/microbiologia , Macrófagos/imunologia , Macrófagos/microbiologia , Masculino , Pessoa de Meia-Idade , Mycobacterium tuberculosis/imunologia , Fagossomos/imunologia , Fagossomos/microbiologia , Proteína A Associada a Surfactante Pulmonar/imunologia , Proteína D Associada a Surfactante Pulmonar/imunologia , Tuberculose/microbiologia , Adulto Jovem
3.
Ultrasound J ; 16(1): 45, 2024 Oct 02.
Artigo em Inglês | MEDLINE | ID: mdl-39356371

RESUMO

BACKGROUND: Point-of-care ultrasound (POCUS) has emerged as an essential bedside tool for clinicians, but lack of access to ultrasound equipment has been a top barrier to POCUS use. Recently, several handheld ultrasound devices ("handhelds") have become available, and clinicians are seeking data to guide purchasing decisions. Few comparative studies of different handhelds have been done. We conducted a cross-sectional study comparing 6 handhelds readily available in the United States (Butterfly iQ + ™ by Butterfly Network Inc.; Clarius™ by Clarius Mobile Health; Kosmos™ by EchoNous; TE Air™ by Mindray; Vscan Air™ SL and CL by General Electric; and Lumify™ by Philips Healthcare). A multi-specialty group of physician POCUS experts (n = 35) acquired three standard ultrasound views (abdominal right upper quadrant, cardiac apical 4-chamber, and superficial neck and lung views) in random order on the same standardized patients and rated the image quality. Afterward, a final survey of the overall ease of use, image quality, and satisfaction of each handheld was completed. RESULTS: Thirty-five POCUS experts specializing in internal medicine/hospital medicine, critical care, emergency medicine, and nephrology acquired and rated right upper quadrant, apical 4-chamber, and superficial neck and lung views with 6 different handhelds. For image quality, the highest-rated handhelds were Vscan Air™ for the right upper quadrant view, Mindray TE Air™ for the cardiac apical 4-chamber view, and Lumify™ for superficial views of the neck and lung. Overall satisfaction with image quality was highest with Vscan Air™, Lumify™, and Mindray, while overall satisfaction with ease of use was highest with Vscan Air™. The 5 most desirable characteristics of handhelds were image quality, ease of use, portability, probe size, and battery life. Ultimately, all 6 handhelds had notable advantages and disadvantages, with no single device having all desired qualities or features. CONCLUSIONS: The overall satisfaction with image quality was rated highest with Vscan Air™, Lumify™, and Mindray TE Air™when acquiring right upper quadrant, apical 4-chamber, and superficial neck and lung views. No single handheld was perceived to be superior in image quality for all views. Vscan Air™ was rated highest for overall ease of use and was the most preferred handheld for purchase by POCUS experts.

5.
Ultrasound J ; 14(1): 27, 2022 Jul 07.
Artigo em Inglês | MEDLINE | ID: mdl-35796842

RESUMO

BACKGROUND: Point-of-care ultrasound (POCUS) is rapidly becoming ubiquitous across healthcare specialties. This is due to several factors including its portability, immediacy of results to guide clinical decision-making, and lack of radiation exposure to patients. The recent growth of handheld ultrasound devices has improved access to ultrasound for many clinicians. Few studies have directly compared different handheld ultrasound devices among themselves or to cart-based ultrasound machines. We conducted a prospective observational study comparing four common handheld ultrasound devices for ease of use, image quality, and overall satisfaction. Twenty-four POCUS experts utilized four handheld devices (Butterfly iQ+™ by Butterfly Network Inc., Kosmos™ by EchoNous, Vscan Air™ by General Electric, and Lumify™ by Philips Healthcare) to obtain three ultrasound views on the same standardized patients using high- and low-frequency probes. RESULTS: Data were collected from 24 POCUS experts using all 4 handheld devices. No single ultrasound device was superior in all categories. For overall ease of use, the Vscan Air™ was rated highest, followed by the Lumify™. For overall image quality, Lumify™ was rated highest, followed by Kosmos™. The Lumify™ device was rated highest for overall satisfaction, while the Vscan Air™ was rated as the most likely to be purchased personally and carried in one's coat pocket. The top 5 characteristics of handheld ultrasound devices rated as being "very important" were image quality, ease of use, portability, total costs, and availability of different probes. CONCLUSIONS: In a comparison of four common handheld ultrasound devices in the United States, no single handheld ultrasound device was perceived to have all desired characteristics. POCUS experts rated the Lumify™ highest for image quality and Vscan Air™ highest for ease of use. Overall satisfaction was highest with the Lumify™ device, while the most likely to be purchased as a pocket device was the Vscan Air™. Image quality was felt to be the most important characteristic in evaluating handheld ultrasound devices.

6.
Diagnostics (Basel) ; 11(2)2021 Feb 22.
Artigo em Inglês | MEDLINE | ID: mdl-33671699

RESUMO

Point-of-care lung ultrasound (LUS) is an attractive alternative to chest X-ray (CXR), but its diagnostic accuracy compared to CXR has not been well studied in coronavirus disease 2019 (COVID-19) patients. We conducted a prospective observational study to assess the correlation between LUS and CXR findings in COVID-19 patients. Ninety-six patients with a clinical diagnosis of COVID-19 underwent an LUS exam and CXR upon presentation. Physicians blinded to the CXR findings performed all LUS exams. Detection of pulmonary infiltrates by CXR versus LUS was compared between patients categorized as suspected or confirmed COVID-19 based on reverse transcriptase-polymerase chain reaction. Sensitivities and correlation by Kappa statistic were calculated between LUS and CXR. LUS detected pulmonary infiltrates more often than CXR in both suspected and confirmed COVID-19 subjects. The most common LUS abnormalities were discrete B-lines, confluent B-lines, and small subpleural consolidations. Most important, LUS detected unilateral or bilateral pulmonary infiltrates in 55% of subjects with a normal CXR. Substantial agreement was demonstrated between LUS and CXR for normal, unilateral or bilateral findings (Κ = 0.48 (95% CI 0.34 to 0.63)). In patients with suspected or confirmed COVID-19, LUS detected pulmonary infiltrates more often than CXR, including more than half of the patients with a normal CXR.

7.
Ultrasound J ; 13(1): 39, 2021 Sep 06.
Artigo em Inglês | MEDLINE | ID: mdl-34487262

RESUMO

BACKGROUND: Lack of training is currently the most common barrier to implementation of point-of-care ultrasound (POCUS) use in clinical practice, and in-person POCUS continuing medical education (CME) courses have been paramount in improving this training gap. Due to travel restrictions and physical distancing requirements during the COVID-19 pandemic, most in-person POCUS training courses were cancelled. Though tele-ultrasound technology has existed for several years, use of tele-ultrasound technology to deliver hands-on training during a POCUS CME course has not been previously described. METHODS: We conducted a retrospective observational study comparing educational outcomes, course evaluations, and learner and faculty feedback from in-person versus tele-ultrasound POCUS courses. The same POCUS educational curriculum was delivered to learners by the two course formats. Data from the most recent pre-pandemic in-person course were compared to tele-ultrasound courses during the COVID-19 pandemic. RESULTS: Pre- and post-course knowledge test scores of learners from the in-person (n = 88) and tele-ultrasound course (n = 52) were compared. Though mean pre-course knowledge test scores were higher among learners of the tele-ultrasound versus in-person course (78% vs. 71%; p = 0.001), there was no significant difference in the post-course test scores between learners of the two course formats (89% vs. 87%; p = 0.069). Both learners and faculty rated the tele-ultrasound course highly (4.6-5.0 on a 5-point scale) for effectiveness of virtual lectures, tele-ultrasound hands-on scanning sessions, and course administration. Faculty generally expressed less satisfaction with their ability to engage with learners, troubleshoot image acquisition, and provide feedback during the tele-ultrasound course but felt learners completed the tele-ultrasound course with a better basic POCUS skillset. CONCLUSIONS: Compared to a traditional in-person course, tele-ultrasound POCUS CME courses appeared to be as effective for improving POCUS knowledge post-course and fulfilling learning objectives. Our findings can serve as a roadmap for educators seeking guidance on development of a tele-ultrasound POCUS training course whose demand will likely persist beyond the COVID-19 pandemic.

8.
Arch Clin Cases ; 7(3): 46-51, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-34754927

RESUMO

Hospitalized patients with SARS-CoV-2 (severe acute respiratory syndrome coronavirus 2) are at risk for developing secondary fungal infections due to greater incidence of preexisting comorbidities and exposure to iatrogenic factors such as corticosteroid use. We present the case of a 44-year-old Hispanic female discovered unresponsive in her home that was found to have severe hyperglycemia with comorbid COVID-19 (coronavirus disease 2019) associated pneumonia. The patient was intubated and treated with several broad-spectrum antibiotics, remdesivir, and corticosteroids but had little improvement in her clinical status. Bronchoscopy was performed and revealed multiple necrotic lesions in the lungs. Endobronchial biopsy and bronchoalveolar lavage samples revealed pauciseptated hyphae consistent with zygomycetes. The patient was treated with multiple antifungals including voriconazole, micafungin, and amphotericin B. However, despite maximal medical therapy, the patient perished. This case highlights that clinicians must carry a high degree of suspicion and a low threshold to begin treatment for Mucor in diabetics and other immunosuppressed patients.

17.
Behav Processes ; 79(3): 195-8, 2008 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-18760337

RESUMO

A wide range of physiological and behavioral alterations occur in response to sickness. Sickness behaviors, rather than incidental by-products or side-effects of acute illness, serve as adaptive functional responses that allow animals to cope with a pathogenic challenge. Among the more salient sickness behaviors is a reduction in food intake; virtually all sick animals display marked decreases in this behavior. Food intake, however, is only one component of the food-related behavioral repertoire. For many mammalian species, food hoarding represents a substantial portion of the total energetic budget. Here we tested the effects of experimental sickness on food hoarding and food intake in a naturally food hoarding species, Siberian hamsters (Phodopus sungorus). Adult male and female hamsters received injections of lipopolysaccharide (LPS) to induce sickness or control injections. LPS-induced sickness resulted in a marked decrease in food intake in both males and females, but did not decrease hoarding in either sex. These results support previous findings suggesting that food hoarding and food intake appear to be differentially regulated at the physiological level.


Assuntos
Comportamento Animal/fisiologia , Ingestão de Alimentos/fisiologia , Comportamento Alimentar/fisiologia , Phodopus/fisiologia , Análise de Variância , Animais , Comportamento Animal/efeitos dos fármacos , Peso Corporal/efeitos dos fármacos , Peso Corporal/fisiologia , Cricetinae , Ingestão de Alimentos/efeitos dos fármacos , Ensaio de Imunoadsorção Enzimática/métodos , Comportamento Alimentar/efeitos dos fármacos , Feminino , Imunoglobulina G/sangue , Imunoglobulinas/sangue , Lipopolissacarídeos/administração & dosagem , Lipopolissacarídeos/imunologia , Lipopolissacarídeos/toxicidade , Masculino , Fatores Sexuais , Comportamento Estereotipado/efeitos dos fármacos , Comportamento Estereotipado/fisiologia
18.
J Urol ; 176(3): 905-9, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16890650

RESUMO

PURPOSE: We reviewed our experience with fat poor cases of angiomyolipoma. MATERIALS AND METHODS: The records of patients with angiomyolipoma, as determined by pathological study, from 1998 to 2004 were reviewed by recording patient demographics and outcomes. Fat poor cases were defined as the failure of imaging to demonstrate fat in a lesion. Computerized tomography and histological characteristics were assessed. RESULTS: Histologically confirmed angiomyolipoma was found in 15 patients. Multiple lesions were found in 3 of 15 cases (20%). Of these 15 patients who underwent surgery 11 (73%) had unsuspected angiomyolipoma due to absent fat on computerized tomography and they underwent intervention for presumed renal cell carcinoma. Mean age +/- SD in this group was 54 +/- 15 years and 8 of 11 patients (73%) were female, of whom 4 (50%) had uterine fibroids. These lesions were found incidentally in 7 of 11 cases (64%). Operative complications developed in 2 of 11 patients (18%). Average maximal diameter on pathological evaluation was 3.2 +/- 1.3 cm (range 1.5 to 6). Nonenhanced computerized tomography was available in 7 of 11 cases, of which 3 of 7 (42%) showed hyperdense lesions and 4 of 7 (57%) showed isodense lesions. The percent of fat identified per high power field was less than 25% in 12 of 13 fat poor angiomyolipoma lesions (92%) compared to 2 of 4 classic lesions (50%) known to be angiomyolipoma before surgery (p = 0.04). CONCLUSIONS: We suggest that a general definition of fat poor angiomyolipoma should be the failure of imaging to reveal fat within a lesion, thus, making it unsuspected at surgery. A pathological definition should be less than 25% fat per high power field, which to our knowledge is a formerly undefined quantity. Not all cases are hyperdense on nonenhanced computerized tomography. These lesions cannot be reliably identified by imaging and they should be managed like all enhancing renal masses.


Assuntos
Angiolipoma/diagnóstico por imagem , Angiolipoma/patologia , Neoplasias Renais/diagnóstico por imagem , Neoplasias Renais/patologia , Tomografia Computadorizada por Raios X , Tecido Adiposo , Adulto , Idoso , Idoso de 80 Anos ou mais , Feminino , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA