Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 10 de 10
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Europace ; 26(4)2024 Mar 30.
Artigo em Inglês | MEDLINE | ID: mdl-38591838

RESUMO

AIMS: Recent trial data demonstrate beneficial effects of active rhythm management in patients with atrial fibrillation (AF) and support the concept that a low arrhythmia burden is associated with a low risk of AF-related complications. The aim of this document is to summarize the key outcomes of the 9th AFNET/EHRA Consensus Conference of the Atrial Fibrillation NETwork (AFNET) and the European Heart Rhythm Association (EHRA). METHODS AND RESULTS: Eighty-three international experts met in Münster for 2 days in September 2023. Key findings are as follows: (i) Active rhythm management should be part of the default initial treatment for all suitable patients with AF. (ii) Patients with device-detected AF have a low burden of AF and a low risk of stroke. Anticoagulation prevents some strokes and also increases major but non-lethal bleeding. (iii) More research is needed to improve stroke risk prediction in patients with AF, especially in those with a low AF burden. Biomolecules, genetics, and imaging can support this. (iv) The presence of AF should trigger systematic workup and comprehensive treatment of concomitant cardiovascular conditions. (v) Machine learning algorithms have been used to improve detection or likely development of AF. Cooperation between clinicians and data scientists is needed to leverage the potential of data science applications for patients with AF. CONCLUSIONS: Patients with AF and a low arrhythmia burden have a lower risk of stroke and other cardiovascular events than those with a high arrhythmia burden. Combining active rhythm control, anticoagulation, rate control, and therapy of concomitant cardiovascular conditions can improve the lives of patients with AF.


Assuntos
Fibrilação Atrial , Acidente Vascular Cerebral , Humanos , Fibrilação Atrial/complicações , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Acidente Vascular Cerebral/etiologia , Acidente Vascular Cerebral/prevenção & controle , Risco , Hemorragia , Anticoagulantes/uso terapêutico
2.
Europace ; 21(4): 636-644, 2019 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-30649270

RESUMO

AIMS: Per standard of care, dual-chamber pacemakers are programmed in DDDR mode with fixed atrioventricular (AV) delay or with long AV delay to minimize ventricular pacing. We aimed to evaluate whether the PR interval may be a specific criterion of choice between standard DDDR, to preserve AV synchrony in long PR patients, and managed ventricular pacing (MVP), to avoid ventricular desynchronization imposed by right ventricle apical pacing, in short PR patients. METHODS AND RESULTS: In the MINERVA trial, 1166 patients were randomized to Control DDDR, MVP, or atrial anti-tachycardia pacing plus MVP (DDDRP + MVP). We evaluated the interaction of PR interval with pacing mode by comparing the risk of atrial fibrillation (AF) longer than 7 consecutive days as a function of PR interval. Out of 906 patients with available data, the median PR interval was 180 ms. The PR interval was found to significantly (P = 0.012) interact with pacing mode for AF incidence: the risk of AF > 7 days was lower [hazard ratio (HR) 0.58, 95% confidence interval (95% CI) 0.34-0.99; P = 0.047] in patients with short PR (shorter than median PR) if programmed in MVP mode compared with DDDR mode and it was lower (HR 0.65, 95% CI 0.43-0.99; P = 0.049) in patients with long PR (equal to or longer than median PR) if programmed in DDDR mode compared with MVP. CONCLUSION: Our data show that PR interval may be used as a selection criterion to identify the optimal physiological pacing mode. Persistent AF incidence was lower in short PR patients treated by right ventricular pacing minimization and in long PR patients treated by standard dual-chamber pacing.


Assuntos
Algoritmos , Fibrilação Atrial/epidemiologia , Bloqueio Atrioventricular/fisiopatologia , Estimulação Cardíaca Artificial/métodos , Bloqueio Interatrial/fisiopatologia , Síndrome do Nó Sinusal/terapia , Idoso , Idoso de 80 Anos ou mais , Arritmias Cardíacas/fisiopatologia , Arritmias Cardíacas/terapia , Fibrilação Atrial/fisiopatologia , Eletrocardiografia , Feminino , Humanos , Incidência , Masculino , Pessoa de Meia-Idade , Marca-Passo Artificial , Prognóstico , Modelos de Riscos Proporcionais , Síndrome do Nó Sinusal/fisiopatologia
3.
Circulation ; 135(19): 1851-1867, 2017 05 09.
Artigo em Inglês | MEDLINE | ID: mdl-28483832

RESUMO

Approximately 10% of ischemic strokes are associated with atrial fibrillation (AF) first diagnosed at the time of stroke. Detecting asymptomatic AF would provide an opportunity to prevent these strokes by instituting appropriate anticoagulation. The AF-SCREEN international collaboration was formed in September 2015 to promote discussion and research about AF screening as a strategy to reduce stroke and death and to provide advocacy for implementation of country-specific AF screening programs. During 2016, 60 expert members of AF-SCREEN, including physicians, nurses, allied health professionals, health economists, and patient advocates, were invited to prepare sections of a draft document. In August 2016, 51 members met in Rome to discuss the draft document and consider the key points arising from it using a Delphi process. These key points emphasize that screen-detected AF found at a single timepoint or by intermittent ECG recordings over 2 weeks is not a benign condition and, with additional stroke factors, carries sufficient risk of stroke to justify consideration of anticoagulation. With regard to the methods of mass screening, handheld ECG devices have the advantage of providing a verifiable ECG trace that guidelines require for AF diagnosis and would therefore be preferred as screening tools. Certain patient groups, such as those with recent embolic stroke of uncertain source (ESUS), require more intensive monitoring for AF. Settings for screening include various venues in both the community and the clinic, but they must be linked to a pathway for appropriate diagnosis and management for screening to be effective. It is recognized that health resources vary widely between countries and health systems, so the setting for AF screening should be both country- and health system-specific. Based on current knowledge, this white paper provides a strong case for AF screening now while recognizing that large randomized outcomes studies would be helpful to strengthen the evidence base.


Assuntos
Fibrilação Atrial/diagnóstico , Fibrilação Atrial/epidemiologia , Internacionalidade , Programas de Rastreamento/métodos , Humanos , Fatores de Risco , Acidente Vascular Cerebral/diagnóstico , Acidente Vascular Cerebral/epidemiologia , Acidente Vascular Cerebral/prevenção & controle
4.
Lancet ; 386(9994): 672-9, 2015 Aug 15.
Artigo em Inglês | MEDLINE | ID: mdl-26211828

RESUMO

BACKGROUND: Catheter ablation is increasingly used to manage atrial fibrillation, but arrhythmia recurrences are common. Adenosine might identify pulmonary veins at risk of reconnection by unmasking dormant conduction, and thereby guide additional ablation to improve arrhythmia-free survival. We assessed whether adenosine-guided pulmonary vein isolation could prevent arrhythmia recurrence in patients undergoing radiofrequency catheter ablation for paroxysmal atrial fibrillation. METHODS: We did this randomised trial at 18 hospitals in Australia, Europe, and North America. We enrolled patients aged older than 18 years who had had at least three symptomatic atrial fibrillation episodes in the past 6 months, and for whom treatment with an antiarrhythmic drug failed. After pulmonary vein isolation, intravenous adenosine was administered. If dormant conduction was present, patients were randomly assigned (1:1) to additional adenosine-guided ablation to abolish dormant conduction or to no further ablation. If no dormant conduction was revealed, randomly selected patients were included in a registry. Patients were masked to treatment allocation and outcomes were assessed by a masked adjudicating committee. Patients were followed up for 1 year. The primary outcome was time to symptomatic atrial tachyarrhythmia after a single procedure in the intention-to-treat population. The trial is registered with ClinicalTrials.gov, number NCT01058980. FINDINGS: Adenosine unmasked dormant pulmonary vein conduction in 284 (53%) of 534 patients. 102 (69·4%) of 147 patients with additional adenosine-guided ablation were free from symptomatic atrial tachyarrhythmia compared with 58 (42·3%) of 137 patients with no further ablation, corresponding to an absolute risk reduction of 27·1% (95% CI 15·9-38·2; p<0·0001) and a hazard ratio of 0·44 (95% CI 0·31-0·64; p<0·0001). Of 115 patients without dormant pulmonary vein conduction, 64 (55·7%) remained free from symptomatic atrial tachyarrhythmia (p=0·0191 vs dormant conduction with no further ablation). Occurrences of serious adverse events were similar in each group. One death (massive stroke) was deemed probably related to ablation in a patient included in the registry. INTERPRETATION: Adenosine testing to identify and target dormant pulmonary vein conduction during catheter ablation of atrial fibrillation is a safe and highly effective strategy to improve arrhythmia-free survival in patients with paroxysmal atrial fibrillation. This approach should be considered for incorporation into routine clinical practice. FUNDING: Canadian Institutes of Health Research, St Jude Medical, Biosense-Webster, and M Lachapelle (Montreal Heart Institute Foundation).


Assuntos
Adenosina , Antiarrítmicos , Fibrilação Atrial/cirurgia , Ablação por Cateter/métodos , Veias Pulmonares/efeitos dos fármacos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Duração da Cirurgia , Modelos de Riscos Proporcionais , Veias Pulmonares/cirurgia , Prevenção Secundária , Resultado do Tratamento
5.
Pacing Clin Electrophysiol ; 38(2): 201-8, 2015 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-25469738

RESUMO

BACKGROUND: Sufficient electrode-tissue contact is crucial for adequate lesion formation in radiofrequency catheter ablation (RFCA). OBJECTIVE: We assessed the impact of direct catheter force measurement on acute procedural parameters and outcome of RFCA for paroxysmal and persistent atrial fibrillation (AF). METHODS: Ninety-nine consecutive patients (70% men) with paroxysmal (63.6%) or persistent AF underwent left atrial RFCA using a 3.5-mm open-irrigated-tip (OIT) catheter with contact force measurement capabilities (group 1). For comparison a case-matched cohort with standard OIT catheters was used (99 patients; group 2). Case matching included gender, type of AF, number or RFCA procedures, and type of procedure. RESULTS: Procedural data showed a significant decline in radiofrequency ablation time from 52 ± 20 to 44 ± 16 minutes (P = 0.003) with a remarkable mean reduction in overall procedure time of 34 minutes (P = 0.0001; 225.8 ± 53.1 vs 191.9 ± 53.3 minutes). In parallel, the total fluoroscopy time could be significantly reduced from 28.5 ± 11.0 to 19.9 ± 9.3 minutes (P = 0.0001) as well as fluoroscopy dose from 74.1 ± 58.0 to 56.7 ± 38.9 Gy/cm(2) (P = 0.016). Periprocedural complications were similar in both groups. CONCLUSIONS: The use of contact force sensing technology is able to significantly reduce ablation, procedure, and fluoroscopy times as well as dose in RFCA of AF in a mixed case-matched group of paroxysmal and persistent AF. Energy delivery is substantially reduced by avoiding radiofrequency ablation in positions with insufficient surface contact. Additionally 12-month outcome data showed increased efficacy. Such time saving and equally safe technology may have a relevant impact on laboratory management and increased cost effectiveness.


Assuntos
Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/cirurgia , Ablação por Cateter/instrumentação , Duração da Cirurgia , Cirurgia Assistida por Computador/instrumentação , Ablação por Cateter/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Retroalimentação , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Radiografia , Estresse Mecânico , Cirurgia Assistida por Computador/métodos , Tato , Resultado do Tratamento
6.
Can J Cardiol ; 36(12): 1965-1974, 2020 12.
Artigo em Inglês | MEDLINE | ID: mdl-33157186

RESUMO

BACKGROUND: Pulmonary vein (PV) stenosis is a complication of atrial fibrillation (AF) ablation. The incidence of PV stenosis after routine post-ablation imaging remains unclear and is limited to single-centre studies. Our objective was to determine the incidence and predictors of PV stenosis following circumferential radiofrequency ablation in the multicentre Adenosine Following Pulmonary Vein Isolation to Target Dormant Conduction Elimination (ADVICE) trial. METHODS: Patients with symptomatic AF underwent circumferential radiofrequency ablation in one of 13 trial centres. Computed tomographic (CTA) or magnetic resonance (MRA) angiography was performed before ablation and 90 days after ablation. Two blinded reviewers measured PV diameters and areas. PVs with stenosis were classified as severe (> 70%), moderate (50%-70%), or mild (< 50%). Predictors of PV stenosis were identified by means of multivariable logistic regression. RESULTS: A total of 197 patients (median age 59.5 years, 29.4% women) were included in this substudy. PV stenosis was identified in 41 patients (20.8%) and 47 (8.2%) of 573 ablated PVs. PV stenosis was classified as mild in 42 PVs (7.3%) and moderate in 5 PVs (0.9%). No PVs had severe stenosis. Both cross-sectional area and diameter yielded similar classifications for severity of PV stenosis. Diabetes was associated with a statistically significant increased risk of PV stenosis (OR 4.91, 95% CI 1.45-16.66). CONCLUSIONS: In the first systematic multicentre evaluation of post-ablation PV stenosis, no patient acquired severe PV stenosis. Although the results are encouraging for the safety of AF ablation, 20.8% of patients had mild or moderate PV stenosis, in which the long-term effects are unknown.


Assuntos
Fibrilação Atrial , Ablação por Cateter/efeitos adversos , Angiografia por Ressonância Magnética , Complicações Pós-Operatórias , Veias Pulmonares , Estenose de Veia Pulmonar , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Canadá/epidemiologia , Ablação por Cateter/métodos , Angiografia por Tomografia Computadorizada/métodos , Angiografia por Tomografia Computadorizada/estatística & dados numéricos , Feminino , Humanos , Incidência , Angiografia por Ressonância Magnética/métodos , Angiografia por Ressonância Magnética/estatística & dados numéricos , Masculino , Pessoa de Meia-Idade , Tamanho do Órgão , Avaliação de Resultados em Cuidados de Saúde , Complicações Pós-Operatórias/diagnóstico , Complicações Pós-Operatórias/epidemiologia , Complicações Pós-Operatórias/fisiopatologia , Veias Pulmonares/diagnóstico por imagem , Veias Pulmonares/patologia , Veias Pulmonares/cirurgia , Fatores de Risco , Índice de Gravidade de Doença , Estenose de Veia Pulmonar/diagnóstico , Estenose de Veia Pulmonar/epidemiologia , Estenose de Veia Pulmonar/etiologia , Estenose de Veia Pulmonar/fisiopatologia
7.
Am Heart J ; 156(3): 445-51, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18760124

RESUMO

BACKGROUND: Dual-chamber (DDD) pacing has generally been regarded as "physiologic pacing" and therefore expected to be superior to ventricular pacing. Major randomized trials have so far failed to demonstrate significant reductions in the incidences of mortality, stroke, and heart failure. It has been shown that unnecessary ventricular pacing in patients with sinus node dysfunction or only intermittent atrioventricular block is associated with ventricular desynchronization and increased risk of atrial tachyarrhythmias (ATA). METHODS: The MINimizE Right Ventricular pacing to prevent Atrial fibrillation and heart failure (MINERVA) study is a prospective, multi-center, randomized, international, single-blind, controlled trial designed to determine whether physiologic pacing through the managed ventricular pacing (MVP) algorithm combined with preventive atrial pacing (PAP) and atrial antitachycardia pacing (ATP) is superior to standard DDD pacing in terms of 2-year reduction in death, permanent ATA, and cardiovascular hospitalizations. Patients with standard class I or II indications for permanent DDD pacing and history of ATA will receive a Medtronic EnRhythm implantable pacemaker (Medtronic, Minneapolis, MN). After a 1-month run-in period, patients will be randomized in a 1:1:1 manner to the DDD (control group, all OFF), the DDDRP (MVP + PAP + ATP ON), and the MVP group (only MVP ON). Up to 1,300 patients will be included in approximately 70 centers in Europe, the Middle East, and Asia. CONCLUSIONS: The MINERVA study will make an important contribution to the management of patients with paroxysmal ATA and accepted indications for dual-chamber pacemaker implantation by determining whether physiologic pacing combined with PAP and ATP is superior to standard DDD pacing in terms of reduction of mortality, incidence of permanent ATA, and cardiovascular hospitalizations.


Assuntos
Função Atrial , Estimulação Cardíaca Artificial/métodos , Projetos de Pesquisa , Taquicardia/fisiopatologia , Taquicardia/terapia , Fibrilação Atrial/prevenção & controle , Doenças Cardiovasculares/prevenção & controle , Doenças Cardiovasculares/terapia , Hospitalização/estatística & dados numéricos , Humanos , Incidência , Método Simples-Cego , Taquicardia/epidemiologia , Taquicardia/mortalidade
9.
Can J Cardiol ; 28(2): 184-90, 2012.
Artigo em Inglês | MEDLINE | ID: mdl-22217936

RESUMO

BACKGROUND: Pulmonary vein (PV) isolation (PVI) has emerged as an effective therapy for paroxysmal atrial fibrillation (AF). However, AF recurs in up to 50% of patients, generally because of recovery of PV conduction. Adenosine given during the initial procedure may reveal dormant PV conduction, thereby identifying the need for additional ablation, leading to improved outcomes. The Adenosine Following Pulmonary Vein Isolation to Target Dormant Conduction Elimination (ADVICE) study is a prospective multicentre randomized trial assessing the impact of adenosine-guided PVI in preventing AF recurrences. METHODS: Patients undergoing a first PVI procedure for paroxysmal AF will be recruited. After standard PVI is completed, all patients will receive intravenous adenosine in an attempt to unmask dormant conduction. If dormant conduction is elicited, patients will be randomized to no further ablation (control group) or additional adenosine-guided ablation until dormant conduction is abolished. If no dormant conduction is revealed, randomly selected patients will be followed in a registry. The primary outcome is time to first documented symptomatic AF recurrence. Assuming that dormant conduction is present in 50% of patients post PVI and symptomatic AF recurs in 45% of controls, 244 patients with dormant conduction will be required to obtain > 90% power to detect a difference of 20%. Thus, a total of 488 patients will be enrolled and followed for 12 months. CONCLUSION: The ADVICE trial will assess whether a PVI strategy incorporating elimination of dormant conduction unmasked by intravenous adenosine will decrease the rate of recurrent symptomatic AF compared with standard PVI.


Assuntos
Adenosina/uso terapêutico , Antiarrítmicos/uso terapêutico , Fibrilação Atrial/terapia , Veias Pulmonares/cirurgia , Fibrilação Atrial/prevenção & controle , Humanos , Estudos Prospectivos , Projetos de Pesquisa , Prevenção Secundária
10.
Heart Rhythm ; 8(1): 65-73, 2011 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-20933098

RESUMO

BACKGROUND: Magnetic resonance imaging (MRI) of pacemaker patients is contraindicated due to documented potential risks to the patient from hazardous interactions between the MRI and pacemaker system. OBJECTIVE: The purpose of this prospective, randomized, controlled, worldwide clinical trial was to evaluate the safety and effectiveness of a pacemaker system designed for safe use in MRI for any bradycardia indicated patient. METHODS: Patients (n = 464) were randomized to undergo an MRI scan between 9 and 12 weeks postimplant (MRI group, n = 258) or not to undergo MRI (control group, n = 206) after successful implantation of the specially designed dual-chamber pacemaker and leads. Patients were monitored for arrhythmias, symptoms, and pacemaker system function during 14 nonclinically indicated relevant brain and lumbar MRI sequences. Sequences were performed at 1.5 T and included scans with high radiofrequency power deposition and/or high gradient dB/dt exposure. Clinical evaluation of the pacemaker system function occurred immediately before and after MRI, 1 week and 1 month post-MRI, and at corresponding times for the control group. Primary endpoints for safety analyzed the MRI procedure complication-free rate and for effectiveness compared capture and sensing performance between MRI and control groups. RESULTS: No MRI-related complications occurred during or after MRI, including sustained ventricular arrhythmias, pacemaker inhibition or output failures, electrical resets, or other pacemaker malfunctions. Pacing capture threshold and sensed electrogram amplitude changes were minimal and similar between study groups. CONCLUSION: This trial documented the ability of this pacemaker system to be exposed in a controlled fashion to MRI in a 1.5 T scanner without adverse impact on patient outcomes or pacemaker system function.


Assuntos
Bradicardia/terapia , Imageamento por Ressonância Magnética , Marca-Passo Artificial , Estimulação Cardíaca Artificial , Contraindicações , Desenho de Equipamento , Humanos , Estudos Prospectivos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA