Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 37
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Eur Heart J ; 44(46): 4862-4873, 2023 Dec 07.
Artigo em Inglês | MEDLINE | ID: mdl-37930776

RESUMO

BACKGROUND AND AIMS: For patients with symptomatic, severe tricuspid regurgitation (TR), early results of transcatheter tricuspid valve (TV) intervention studies have shown significant improvements in functional status and quality of life associated with right-heart reverse remodelling. Longer-term follow-up is needed to confirm sustained improvements in these outcomes. METHODS: The prospective, single-arm, multicentre TRISCEND study enrolled 176 patients to evaluate the safety and performance of transcatheter TV replacement in patients with ≥moderate, symptomatic TR despite medical therapy. Major adverse events, reduction in TR grade and haemodynamic outcomes by echocardiography, and clinical, functional, and quality-of-life parameters are reported to one year. RESULTS: Enrolled patients were 71.0% female, mean age 78.7 years, 88.0% ≥ severe TR, and 75.4% New York Heart Association classes III-IV. Tricuspid regurgitation was reduced to ≤mild in 97.6% (P < .001), with increases in stroke volume (10.5 ± 16.8 mL, P < .001) and cardiac output (0.6 ± 1.2 L/min, P < .001). New York Heart Association class I or II was achieved in 93.3% (P < .001), Kansas City Cardiomyopathy Questionnaire score increased by 25.7 points (P < .001), and six-minute walk distance increased by 56.2 m (P < .001). All-cause mortality was 9.1%, and 10.2% of patients were hospitalized for heart failure. CONCLUSIONS: In an elderly, highly comorbid population with ≥moderate TR, patients receiving transfemoral EVOQUE transcatheter TV replacement had sustained TR reduction, significant increases in stroke volume and cardiac output, and high survival and low hospitalization rates with improved clinical, functional, and quality-of-life outcomes to one year. Funded by Edwards Lifesciences, TRISCEND ClinicalTrials.gov number, NCT04221490.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Humanos , Feminino , Idoso , Masculino , Insuficiência da Valva Tricúspide/epidemiologia , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Estudos Prospectivos , Qualidade de Vida , Resultado do Tratamento , Cateterismo Cardíaco/métodos , Índice de Gravidade de Doença
2.
Heart Fail Clin ; 19(3): 285-296, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37230644

RESUMO

This review discusses the contemporary clinical evaluation and management of patients with comorbid aortic regurgitation (AR) and heart failure (HF) (AR-HF). Importantly, as clinical HF exists along the spectrum of AR severity, the present review also details novel strategies to detect early signs of HF before the clinical syndrome ensues. Indeed, there may be a vulnerable cohort of AR patients who benefit from early detection and management of HF. Additionally, while the mainstay of operative management for AR has historically been surgical aortic valve replacement, this review discusses alternate procedures that may be beneficial in high-risk cohorts.


Assuntos
Insuficiência da Valva Aórtica , Estenose da Valva Aórtica , Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Humanos , Insuficiência da Valva Aórtica/complicações , Insuficiência da Valva Aórtica/diagnóstico , Insuficiência da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Resultado do Tratamento
3.
Heart Fail Clin ; 19(3): 297-305, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37230645

RESUMO

Primary mitral regurgitation is a frequent etiology of congestive heart failure and is best treated with intervention when patients are symptomatic or when additional risk factors exist. Surgical intervention improves outcomes in appropriately selected patients. However, for those at high surgical risk, transcatheter intervention provides less invasive repair and replacement options while providing comparable outcomes to surgery. The excess mortality and high prevalence of heart failure in untreated mitral regurgitation illuminate the need for further developments in mitral valve intervention ideally fulfilled by expanding these types of procedures and eligibility to these procedures beyond only those at high surgical risk.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Implante de Prótese de Valva Cardíaca/efeitos adversos , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/terapia , Insuficiência Cardíaca/etiologia , Cateterismo Cardíaco/métodos , Resultado do Tratamento
4.
Heart Fail Clin ; 19(3): 307-315, 2023 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-37230646

RESUMO

The causes of mitral regurgitation (MR) can be broadly divided into primary and secondary causes. Although primary MR is caused by degenerative alterations of the mitral valve and the mitral valve apparatus, secondary (functional) MR is multifactorial and related to dilation of the left ventricle and/or mitral annulus commonly resulting in concomitant restriction of the leaflets. Therefore, the treatment of secondary MR (SMR) is complex and includes guideline directed heart failure therapy along with surgical and transcatheter approaches that have shown effectiveness in certain subgroups. This review aims to provide insight into current advances in diagnosis and management of SMR.


Assuntos
Insuficiência Cardíaca , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Humanos , Insuficiência da Valva Mitral/diagnóstico , Insuficiência da Valva Mitral/etiologia , Insuficiência da Valva Mitral/cirurgia , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/etiologia , Insuficiência Cardíaca/terapia , Cateterismo Cardíaco/métodos , Resultado do Tratamento
5.
J Card Surg ; 37(7): 1947-1956, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35384050

RESUMO

BACKGROUND: Valve-sparing aortic root replacement (VSARR) is an alternative to valve-replacing aortic root replacement (VRARR) with valved-conduits based on recent guidelines for clinical practice. This study investigated outcomes of these two procedures in patients with nonstenotic valves. METHODS: Between January 7, 2007 and June 30, 2019, 475 patients with aortic root aneurysm without aortic stenosis underwent VSARR (151) or VRARR (324) techniques. Propensity score-matching (PSM) was used to alleviate confounding. Endpoints were 30-day mortality, 8-year survival and reoperation, aortic regurgitation, and valve gradients. RESULTS: PSM created 69 pairs of patients with a mean age 52 ± 13 years (10.1% Marfan syndrome, 34.8% bicuspid aortic valve). There was no statistically significant difference in major perioperative morbidity or 30-day mortality (0% VSARR vs. 1.4% VRARR; p = 0.316). Overall survival was significantly higher (p = 0.025) in the VSARR group versus the VRARR group (8-year estimates 100% vs. 88.9%, respectively), while freedom from valve reoperation was similar (p = 0.97, 8-year estimates 90.9% vs. 96.7%, respectively). Freedom from > moderate-severe AR was not significantly different (p = 0.08, 8-year estimates 90.0% VSARR group vs. 100% VRARR), but mean valve gradients at last follow-up were better in the VSARR group (5.9 vs. 13.2 mmHg, p < 0.001). CONCLUSIONS: VSARR is a safe operation in patients with aortic root aneurysm and nonstenotic aortic valves in the hands of experienced surgeons. Freedom from reoperation is similar and the mode of aortic valve failure differs between the two groups.


Assuntos
Aneurisma da Aorta Torácica , Insuficiência da Valva Aórtica , Implante de Prótese de Valva Cardíaca , Adulto , Idoso , Aneurisma da Aorta Torácica/cirurgia , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/etiologia , Insuficiência da Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca/métodos , Humanos , Pessoa de Meia-Idade , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
6.
Echocardiography ; 38(7): 1165-1172, 2021 07.
Artigo em Inglês | MEDLINE | ID: mdl-34028863

RESUMO

BACKGROUND: Elite athletes show structural cardiac changes as an adaptation to exercise. Studies examining strain in athletes have largely analyzed images at rest only. There is little data available regarding the change in strain with exercise. Our objectives were: to investigate the feasibility of strain analysis in athletes at peak exercise, to determine the normal range of left ventricular (LV) global longitudinal strain (GLS) within this population postexercise, to describe how LV GLS changes with exercise, and to determine whether any clinical characteristics correlate with the change in GLS that occurs with exercise. METHODS: We conducted a cross-sectional study on elite athletes who participated in the 2016-2018 National Basketball Association Draft Combines. Echocardiograms were obtained at rest and after completing a treadmill stress test to maximal exertion or completion of Bruce protocol. Primary outcomes included GLS obtained at rest and peak exercise. Secondary outcome was the change in GLS between rest and exercise. Univariate relationships between various clinical characteristics and our secondary outcome were analyzed. RESULTS: Our final cohort (n = 111) was all male and 92/111 (82.9%) were African American. Mean GLS magnitude increased in response to exercise (-17.6 ± 1.8 vs -19.2 ± 2.6, P < .0001). Lower resting heart rates (r = .22, P = .02) and lower heart rates at peak exercise (r = .21, P = .03) correlated with the increase in LV GLS from exercise. CONCLUSIONS: Strain imaging is technically feasible to obtain among elite basketball athletes at peak exercise. Normative strain response to exercise from this study may help identify abnormal responses to exercise in athletes.


Assuntos
Basquetebol , Função Ventricular Esquerda , Atletas , Estudos Transversais , Ecocardiografia , Estudos de Viabilidade , Humanos , Masculino
7.
Echocardiography ; 37(6): 913-916, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-32472553

RESUMO

Tricuspid valve (TV) degeneration after surgical repair with an annuloplasty ring is problematic as redo operation carries high mortality. This can be addressed with transcatheter therapies to implant a valve within in prior ring (tricuspid valve-in-ring). When an incomplete ring is present, paravalvular leak is commonly encountered after tricuspid valve-in-ring (TViR) implant; however, this can be addressed with paravalvular leak closure devices. Multimodality imaging including cardiac computed tomography and three-dimensional (3D) transesophageal echocardiography (TEE) are important for successful TViR implant. We report a case of tricuspid regurgitation after tricuspid repair with an incomplete annuloplasty ring and subsequent paravalvular leak closure.


Assuntos
Implante de Prótese de Valva Cardíaca , Próteses Valvulares Cardíacas , Insuficiência da Valva Tricúspide , Cateterismo Cardíaco , Ecocardiografia Transesofagiana , Próteses Valvulares Cardíacas/efeitos adversos , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Valva Mitral/cirurgia , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia
8.
J Card Fail ; 24(9): 614-617, 2018 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-30081076

RESUMO

BACKGROUND: Rehospitalization for heart failure (HF) is common, and subclinical congestion may be present at discharge. Larger inferior vena cava (IVC) size and lower collapsibility at discharge assessed via bedside ultrasound are predictive of rehospitalization; however, the utility of IVC assessment with the use of pocket-carried ultrasound (PCUS) during the transition from discharge to the posthospitalization follow-up visit (FU) has not been investigated. METHODS AND RESULTS: IVCmax and IVCmin were measured with the use of PCUS, and the collapsibility index (IVCCI = [IVCmax - IVCmin]/IVCmax) was determined. The primary outcome was 90-day rehospitalization or death. We prospectively enrolled 49 adults (71 ± 13 years of age, 51% male, 47% black, 43% preserved ejection fraction) hospitalized for HF. Nineteen patients (39%) experienced the outcome. Within the rehospitalized group, discharge and FU mean IVCmax were both >2.1 cm (2.2 ± 0.5 and 2.2 ± 0.7) and IVCCIs <50% (44 ± 20% and 45 ± 24%). Within those not rehospitalized, FU IVCmax was ≤2.1 cm (2.1 ± 0.6 and 1.9 ± 0.6; P = .038) and IVCCI >50% at both time points (55 ± 25% and 62 ± 19%; P = NS). FU IVCCI below an optimal cutoff of 42% had modest discrimination alone (c-statistic = 0.73). FU IVCCI <42% was associated with a greater hazard of the outcome independent of admission log B-type natriuretic peptide (adjusted hazard ratio = 6.8; 95% confidence interval 2.4-19.0; P < .001). CONCLUSIONS: Posthospitalization IVCCI assessment with PCUS predicts HF rehospitalization and may identify patients in need of intervention.


Assuntos
Insuficiência Cardíaca/terapia , Readmissão do Paciente/estatística & dados numéricos , Sistemas Automatizados de Assistência Junto ao Leito , Ultrassonografia/instrumentação , Veia Cava Inferior/diagnóstico por imagem , Doença Aguda , Idoso , Desenho de Equipamento , Feminino , Seguimentos , Insuficiência Cardíaca/diagnóstico , Insuficiência Cardíaca/fisiopatologia , Humanos , Masculino , Projetos Piloto , Valor Preditivo dos Testes , Estudos Prospectivos , Fatores de Tempo
11.
Perfusion ; 32(7): 529-537, 2017 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-28423986

RESUMO

PURPOSE: Measuring myocardial strain using two-dimensional speckle tracking echocardiography has emerged as a new tool to identify subclinical ventricular dysfunction. Abnormal strain has been shown to have superior sensitivity compared with dobutamine stress echocardiography for viability assessment; however, there is a paucity of data regarding the prediction of long-term major adverse cardiac events. We compared the prognostic ability of both global longitudinal strain (GLS) from resting echocardiograms to regional wall motion score index (WMSI) from stress echocardiograms in their ability to predict long-term major adverse cardiac events. METHODS: Patients referred for stress echocardiography, who also underwent coronary angiography within 3 months of stress echo (n=122), were enrolled. Patients with reduced ejection fractions (<40%) were excluded. Patients were followed for a median of 3.4 years for major adverse cardiac events, readmissions and repeat cardiac testing. RESULTS: Patients with abnormal GLS (GLS <16.8%) from the resting echocardiogram obtained as part of the exercise echocardiogram experienced a significantly shorter time to major adverse cardiac events (p=0.026), first cardiovascular hospitalization and repeat cardiac testing (p=0.0011) compared to those with normal GLS. Abnormal GLS appears to be a better predictor than abnormal WMSI in predicting major adverse cardiac events (p=0.174) and time to first cardiovascular hospitalization or repeat cardiac testing (p=0.0093). CONCLUSION: GLS may be a better predictor of long-term major adverse cardiac events, readmissions and repeat cardiac testing than WMSI in patients undergoing stress echocardiography.


Assuntos
Doença da Artéria Coronariana/complicações , Ecocardiografia sob Estresse/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Ecocardiografia sob Estresse/métodos , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Medição de Risco
12.
JACC Cardiovasc Imaging ; 17(7): 729-742, 2024 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-38842961

RESUMO

BACKGROUND: Tricuspid valve transcatheter edge-to-edge repair (T-TEER) is the most widely used transcatheter therapy to treat patients with tricuspid regurgitation (TR). OBJECTIVES: The aim of this study was to develop a simple anatomical score to predict procedural outcomes of T-TEER. METHODS: All patients (n = 168) who underwent T-TEER between January 2017 and November 2022 at 2 centers were included in the derivation cohort. Additionally, 126 patients from 2 separate institutions served as a validation cohort. T-TEER was performed using 2 commercially available technologies. Core laboratory assessment of procedural transesophageal echocardiograms was used to determine septolateral and anteroposterior coaptation gap, leaflet morphology, septal leaflet length and retraction, chordal structure density, tethering height, en face TR jet morphology and TR jet location, image quality, and the presence of intracardiac leads. A scoring system was derived using univariable and multivariable logistic regression. Endpoints assessed were immediate postprocedural TR reduction ≥2 grades and TR grade moderate or less. RESULTS: The median age was 82 years (Q1-Q3: 78-84 years); 48% of patients were women; and patients presented with severe (55%), massive (36%), and torrential (8%) TR. Five variables (septolateral coaptation gap, chordal structure density, en face TR jet morphology, TR jet location, and image quality) were identified as best predicting procedural outcome and were incorporated in the GLIDE (Gap, Location, Image quality, density, en-face TR morphology) score (range 0-5). TR reduction ≥2 grades and TR grade moderate or less were observed in >90% of patients with GLIDE scores of 0 and 1 and in only 5.6% and 16.7% of those with GLIDE scores ≥4. The GLIDE score was then externally validated in a separate cohort (area under the curve: 0.77; 95% CI: 0.69-0.86). TR reduction significantly correlated with functional improvement assessed by NYHA functional class and 6-minute walk distance at 3 months. CONCLUSIONS: The GLIDE score is a simple, 5-component score that is readily obtained during patient imaging and can predict successful T-TEER.


Assuntos
Cateterismo Cardíaco , Ecocardiografia Transesofagiana , Valor Preditivo dos Testes , Recuperação de Função Fisiológica , Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Feminino , Masculino , Idoso , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/fisiopatologia , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/fisiopatologia , Valva Tricúspide/cirurgia , Resultado do Tratamento , Idoso de 80 Anos ou mais , Reprodutibilidade dos Testes , Estudos Retrospectivos , Fatores de Risco , Técnicas de Apoio para a Decisão , Medição de Risco , Fatores de Tempo
13.
JACC Cardiovasc Imaging ; 17(5): 471-485, 2024 May.
Artigo em Inglês | MEDLINE | ID: mdl-38099912

RESUMO

BACKGROUND: The CLASP IID randomized trial (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial) demonstrated the safety and effectiveness of the PASCAL system for mitral transcatheter edge-to-edge repair (M-TEER) in patients at prohibitive surgical risk with significant symptomatic degenerative mitral regurgitation (DMR). OBJECTIVES: This study describes the echocardiographic methods and outcomes from the CLASP IID trial and analyzes baseline variables associated with residual mitral regurgitation (MR) ≤1+. METHODS: An independent echocardiographic core laboratory assessed echocardiographic parameters based on American Society of Echocardiography guidelines focusing on MR mechanism, severity, and feasibility of M-TEER. Factors associated with residual MR ≤1+ were identified using logistic regression. RESULTS: In 180 randomized patients, baseline echocardiographic parameters were well matched between the PASCAL (n = 117) and MitraClip (n = 63) groups, with flail leaflets present in 79.2% of patients. Baseline MR was 4+ in 76.4% and 3+ in 23.6% of patients. All patients achieved MR ≤2+ at discharge. The proportion of patients with MR ≤1+ was similar in both groups at discharge but diverged at 6 months, favoring PASCAL (83.7% vs 71.2%). Overall, patients with a smaller flail gap were significantly more likely to achieve MR ≤1+ at discharge (adjusted OR: 0.70; 95% CI: 0.50-0.99). Patients treated with PASCAL and those with a smaller flail gap were significantly more likely to sustain MR ≤1+ to 6 months (adjusted OR: 2.72 and 0.76; 95% CI: 1.08-6.89 and 0.60-0.98, respectively). CONCLUSIONS: The study used DMR-specific echocardiographic methodology for M-TEER reflecting current guidelines and advances in 3-dimensional echocardiography. Treatment with PASCAL and a smaller flail gap were significant factors in sustaining MR ≤1+ to 6 months. Results demonstrate that MR ≤1+ is an achievable benchmark for successful M-TEER. (Edwards PASCAL TrAnScatheter Valve RePair System Pivotal Clinical Trial [CLASP IID]; NCT03706833).


Assuntos
Cateterismo Cardíaco , Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Mitral , Valva Mitral , Valor Preditivo dos Testes , Recuperação de Função Fisiológica , Índice de Gravidade de Doença , Humanos , Insuficiência da Valva Mitral/diagnóstico por imagem , Insuficiência da Valva Mitral/cirurgia , Insuficiência da Valva Mitral/fisiopatologia , Masculino , Feminino , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Valva Mitral/fisiopatologia , Resultado do Tratamento , Cateterismo Cardíaco/instrumentação , Cateterismo Cardíaco/efeitos adversos , Idoso , Fatores de Risco , Implante de Prótese de Valva Cardíaca/instrumentação , Implante de Prótese de Valva Cardíaca/efeitos adversos , Fatores de Tempo , Idoso de 80 Anos ou mais , Próteses Valvulares Cardíacas , Estudos de Viabilidade , Medição de Risco , Desenho de Prótese , Ecocardiografia Tridimensional
14.
PLoS One ; 18(2): e0281993, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-36800368

RESUMO

Vaccine development against COVID-19 has mitigated severe disease. However, reports of rare but serious adverse events following immunization (sAEFI) in the young populations are fuelling parental anxiety and vaccine hesitancy. With a very early season of viral illnesses including COVID-19, respiratory syncytial virus (RSV), influenza, metapneumovirus and several others, children are facing a winter with significant respiratory illness burdens. Yet, COVID-19 vaccine and booster uptake remain sluggish due to the mistaken beliefs that children have low rates of severe COVID-19 illness as well as rare but severe complications from COVID-19 vaccine are common. In this study we examined composite sAEFI reported in association with COVID-19 vaccines in the United States (US) amongst 5-17-year-old children, to ascertain the composite reported risk associated with vaccination. Between December 13, 2020, and April 13, 2022, a total of 467,890,599 COVID-19 vaccine doses were administered to individuals aged 5-65 years in the US, of which 180 million people received at least 2 doses. In association with these, a total of 177,679 AEFI were reported to the Vaccine Adverse Event reporting System (VAERS) of which 31,797 (17.9%) were serious. The rates of ED visits per 100,000 recipients were 2.56 (95% CI: 2.70-3.47) amongst 5-11-year-olds, 18.25 (17.57-18.95) amongst 12-17-year-olds and 33.74 (33.36-34.13) amongst 18-65-year olds; hospitalizations were 1.07 (95% CI 0.87-1.32) per 100,000 in 5-11-year-olds, 6.83 (6.42-7.26) in 12-17-year olds and 8.15 (7.96-8.35) in 18-65 years; life-threatening events were 0.14 (95% CI: 0.08-0.25) per 100,000 in 5-11-year olds, 1.22 (1.05-1.41) in 12-17-year-olds and 2.96 (2.85-3.08) in 18-65 year olds; and death 0.03 (95% CI 0.01-0.10) per 100,000 in 5-11 year olds, 0.08 (0.05-0.14) amongst 12-17-year olds and 0.76 (0.71-0.82) in 18-65 years age group. The results of our study from national population surveillance data demonstrate rates of reported serious AEFIs amongst 5-17-year-olds which appear to be significantly lower than in 18-65-year-olds. These low risks must be taken into account in overall recommendation of COVID-19 vaccination amongst children.


Assuntos
Vacinas contra COVID-19 , COVID-19 , Adolescente , Adulto , Idoso , Criança , Pré-Escolar , Humanos , Pessoa de Meia-Idade , Adulto Jovem , Sistemas de Notificação de Reações Adversas a Medicamentos , COVID-19/epidemiologia , COVID-19/prevenção & controle , Vacinas contra COVID-19/efeitos adversos , Imunização/efeitos adversos , Estados Unidos/epidemiologia , Vacinação/efeitos adversos
15.
Front Cardiovasc Med ; 10: 1256420, 2023.
Artigo em Inglês | MEDLINE | ID: mdl-38034383

RESUMO

This study aims to assess whether the On-X aortic valved conduit better restores normal valvular and ascending aortic hemodynamics than other commonly used bileaflet mechanical valved conduit prostheses from St. Jude Medical and Carbomedics by using same-day transthoracic echocardiography (TTE) and 4D flow magnetic resonance imaging (MRI) examinations. TTE and 4D flow MRI were performed back-to-back in 10 patients with On-X, six patients with St. Jude (two) and Carbomedics (four) prostheses, and 36 healthy volunteers. TTE evaluated valvular hemodynamic parameters: transvalvular peak velocity (TPV), mean and peak transvalvular pressure gradient (TPG), and effective orifice area (EOA). 4D flow MRI evaluated the peak systolic 3D viscous energy loss rate (VELR) density and mean vorticity magnitude in the ascending aorta (AAo). While higher TPV and mean and peak TPG were recorded in all patients compared to healthy subjects, the values in On-X patients were closer to those in healthy subjects (TPV 1.9 ± 0.3 vs. 2.2 ± 0.3 vs. 1.2 ± 0.2 m/s, mean TPG 7.4 ± 1.9 vs. 9.2 ± 2.3 vs. 3.1 ± 0.9 mmHg, peak TPG 15.3 ± 5.2 vs. 18.9 ± 5.2 vs. 6.1 ± 1.8 mmHg, p < 0.001). Likewise, while higher VELR density and mean vorticity magnitude were recorded in all patients than in healthy subjects, the values in On-X patients were closer to those in healthy subjects (VELR: 50.6 ± 20.1 vs. 89.8 ± 35.2 vs. 21.4 ± 9.2 W/m3, p < 0.001) and vorticity (147.6 ± 30.0 vs. 191.2 ± 26.0 vs. 84.6 ± 20.5 s-1, p < 0.001). This study demonstrates that the On-X aortic valved conduit may produce less aberrant hemodynamics in the AAo while maintaining similar valvular hemodynamics to St. Jude Medical and Carbomedics alternatives.

16.
JACC Cardiovasc Interv ; 16(13): 1579-1589, 2023 07 10.
Artigo em Inglês | MEDLINE | ID: mdl-37438025

RESUMO

BACKGROUND: Transcatheter tricuspid valve repair (TTVr) has significantly expanded treatment options for tricuspid regurgitation (TR). However, a sizeable proportion of patients are still declined for TTVr and little is known about their clinical characteristics and cardiac morphology. OBJECTIVES: This study sought to characterize patients who screen fail for TTVr with respect to their clinical characteristics and cardiac morphology. METHODS: A total of 547 patients were evaluated for TTVr between January 2016 to December 2021 from 3 centers in the United States and Germany. Clinical records and echocardiographic studies were used to assess medical history and right ventricular (RV) and tricuspid valve (TV) characteristics. RESULTS: Median age was 80 (IQR: 74-83) years and 60.0% were female. Over half (58.1%) were accepted for TTVr. Of those who were deemed unsuitable for TTVr (41.9%), the most common exclusion reasons were anatomical criteria (56.8%). In the regression analysis, RV and right atrial size, TV coaptation gap, and tethering area were identified as independent screen failure predictors. Other rejection reasons included clinical futility (17.9%), low symptom burden (12.7%), and technical limitations (12.7%). Most of the excluded patients (71.6%) were managed conservatively with medical therapy, while a small number either proceeded to TV surgery (22.3%) or subsequently became eligible for transcatheter tricuspid valve replacement in later available clinical trials in the United States (6.1%). CONCLUSIONS: The majority of TTVr screen failure patients are excluded due to TV, right atrial, and RV enlargement. However, a significant proportion is excluded due to clinical futility. These identifiable anatomical and clinical characteristics emphasize the importance of earlier referral and intervention of TR and the need for continued innovation of Transcatheter tricuspid valve interventions.


Assuntos
Apêndice Atrial , Ecocardiografia , Ventrículos do Coração , Insuficiência da Valva Tricúspide , Valva Tricúspide , Humanos , Masculino , Feminino , Idoso de 80 Anos ou mais , Idoso , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Apêndice Atrial/diagnóstico por imagem , Estados Unidos , Alemanha , Estudos Retrospectivos , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Ventrículos do Coração/diagnóstico por imagem
17.
Ann Cardiothorac Surg ; 11(4): 369-379, 2022 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-35958531

RESUMO

Patients with bicuspid aortic valves commonly require an intervention on their valve and/or aorta. Because of their heterogeneous presentations, recommendations for imaging surveillance and surgery timing are highly individualized. Critical points in care include time of diagnosis, transition from adolescent to adult medicine, and surgery referral. To better support patients with bicuspid aortic valves, we developed a comprehensive program that utilizes the multidisciplinary care team, complex interventions, and translational research protocols. We describe our program structure and experience with this common and sometimes challenging diagnosis.

18.
JACC Cardiovasc Interv ; 15(19): 1921-1932, 2022 10 10.
Artigo em Inglês | MEDLINE | ID: mdl-36202561

RESUMO

BACKGROUND: Tricuspid regurgitation (TR) is prevalent and undertreated, with mortality and morbidity increasing with TR severity. Given poor outcomes with medical therapy and high in-hospital mortality for isolated tricuspid valve surgery, emerging transcatheter repair devices offer a promising alternative. OBJECTIVES: The Edwards Cardioband Tricuspid Valve Reconstruction System Early Feasibility study (NCT03382457) evaluates the treatment of functional TR via annular reduction with the Cardioband Tricuspid Valve Reconstruction System (Edwards Lifesciences). METHODS: Patients with ≥ moderate functional TR were eligible for this prospective, single-arm multicenter study. At 1 year, patients were evaluated for echocardiographic parameters, clinical and quality-of-life measures, and major adverse events. RESULTS: The 37 patients enrolled had a mean age of 78 years; 76% were female; and they had ≥ severe functional (97.3%) or mixed (2.7%) TR, atrial flutter/fibrillation (97%), and New York Heart Association functional class III/IV (65%). At 1 year, 73.0% achieved ≤ moderate TR (P < 0.0001), and 73.1% had ≥2 grade reductions. Echocardiography showed significant reductions in the tricuspid annulus diameter (P < 0.0001), mean vena contracta (P < 0.0001), proximal isovelocity surface area effective regurgitant orifice area (P < 0.0001), right ventricular end-diastolic diameter (P < 0.0001), and inferior vena contracta (P = 0.0006). New York Heart Association functional class improved significantly (P < 0.0001), with 92.3% achieving class I/II, and Kansas City Cardiomyopathy Questionnaire scores improved by 19.0 points (P < 0.0001). One-year cardiovascular mortality was 8.1%, reinterventions were necessary in 5.4%, major access site complications occurred in 8.1%, and severe bleeding was noted in 35.1% of patients. Kaplan-Meier estimates of survival and freedom from heart failure rehospitalization were 85.9% and 88.7%, respectively. CONCLUSIONS: One-year experience using the Cardioband system for tricuspid valve repair shows high survival and low rehospitalization rates with durable outcomes in TR reduction and echocardiographic, clinical, and quality-of-life outcomes.


Assuntos
Implante de Prótese de Valva Cardíaca , Insuficiência da Valva Tricúspide , Idoso , Cateterismo Cardíaco , Estudos de Viabilidade , Feminino , Humanos , Masculino , Estudos Prospectivos , Índice de Gravidade de Doença , Resultado do Tratamento , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia , Insuficiência da Valva Tricúspide/diagnóstico por imagem , Insuficiência da Valva Tricúspide/cirurgia
19.
Curr Opin Cardiol ; 25(5): 464-8, 2010 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-20657279

RESUMO

PURPOSE OF REVIEW: The focus only on the left ventricle (LV) for both evaluation of cardiac dyssynchrony and the efficacy of resynchronization therapy (CRT) is too limited to explain the nuances of clinical response to CRT. Right ventricular function, synchrony and remodeling are now commonly characterized noninvasively. This review presents new insights into the role of the right ventricle independently and in conjunction with the LV in determining the clinical efficacy of CRT. RECENT FINDINGS: There are patients with predominantly right ventricular dyssynchrony who respond to CRT without reverse remodeling of the LV. Studies of longitudinal axis function of the right ventricle show that contractile function improvement precedes right ventricular reverse remodeling in clinical responders to CRT. The discordance seen in some CRT responders between improvements in left ventricular and right ventricular morphology, function and markers of synchrony is best understood using multiple markers of cardiac longitudinal axis function and cardiac deformation analysis. SUMMARY: Advanced right ventricular dysfunction reduces the likelihood of clinical response to CRT. However, right ventricular contractile function may improve following CRT independent of changes in right ventricular size or volumetric measures of right ventricular function. The consequences of isolated improvements in right ventricular function on CRT-related prognosis deserve further study.


Assuntos
Estimulação Cardíaca Artificial , Função Ventricular Esquerda/fisiologia , Insuficiência Cardíaca/fisiopatologia , Insuficiência Cardíaca/terapia , Humanos , Remodelação Ventricular/fisiologia
20.
J Thorac Cardiovasc Surg ; 159(6): 2216-2226.e2, 2020 06.
Artigo em Inglês | MEDLINE | ID: mdl-31543305

RESUMO

OBJECTIVE: Bicuspid aortic valve is a common risk factor for thoracic aortic aneurysm and dissection. Guidelines for elective ascending aortic intervention (AAI) in bicuspid aortic valve are derived from limited evidence, and the extent of practice variation due to patient and provider characteristics is unknown. Using data from 2 large cardiovascular registries, we investigated factors that influence decisions for AAI. METHODS: All bicuspid aortic valve cases with known aortic diameters and surgical status were included. We used multivariable logistic regression to profile predictors of isolated aortic valve replacement (AVR) or AVR+AAI, stratified by patient characteristics, surgical indications, and institution. RESULTS: We studied 2861 subjects at 18 institutions from 1996 to 2015. The median aortic diameter of patients who underwent AVR+AAI varied widely across institutions (39-52 mm). Aortic diameters were <45 mm in 38% of patients undergoing AVR+AAI. Patients who underwent AAI at <45 mm, compared with those managed nonoperatively, were younger (54 ± 13 vs 61 ± 15 years; P < .001) with more frequent aortic stenosis (53% vs 28%; P < .001) and regurgitation (52% vs 18%; P < .001). CONCLUSIONS: Clinical and institutional factors influence the timing of AAI and are associated with significant variability in ascending aortic diameter at AAI across institutions. More than one third of patients with a bicuspid aortic valve undergo AAI at aortic diameters <45 mm. Long-term outcomes of this subgroup of patients, who may manifest earlier and more severe disease, are needed to determine the risk-benefit ratio of routine aortic interventions at smaller diameters.


Assuntos
Aneurisma da Aorta Torácica/cirurgia , Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/anormalidades , Doenças das Valvas Cardíacas/cirurgia , Implante de Prótese de Valva Cardíaca , Procedimentos Cirúrgicos Vasculares , Adulto , Idoso , Aneurisma da Aorta Torácica/diagnóstico por imagem , Aneurisma da Aorta Torácica/etiologia , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Insuficiência da Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/etiologia , Estenose da Valva Aórtica/diagnóstico por imagem , Estenose da Valva Aórtica/etiologia , Doença da Válvula Aórtica Bicúspide , Tomada de Decisão Clínica , Estudos Transversais , Procedimentos Cirúrgicos Eletivos , Feminino , Doenças das Valvas Cardíacas/complicações , Doenças das Valvas Cardíacas/diagnóstico por imagem , Implante de Prótese de Valva Cardíaca/efeitos adversos , Humanos , Masculino , Pessoa de Meia-Idade , Seleção de Pacientes , Sistema de Registros , Medição de Risco , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento , Estados Unidos , Procedimentos Cirúrgicos Vasculares/efeitos adversos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA