Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 1 de 1
Filtrar
Mais filtros

Base de dados
Assunto principal
Ano de publicação
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Eur J Radiol ; 171: 111267, 2024 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-38169217

RESUMO

PURPOSE: Computed tomography (CT) scans are a significant source of medically induced radiation exposure. Novel deep learning-based denoising (DLD) algorithms have been shown to enable diagnostic image quality at lower radiation doses than iterative reconstruction (IR) methods. However, most comparative studies employ low-dose simulations due to ethical constraints. We used real intraindividual animal scans to investigate the dose-reduction capabilities of a DLD algorithm in comparison to IR. MATERIALS AND METHODS: Fourteen veterinarian-sedated alive pigs underwent 2 CT scans on the same 3rd generation dual-source scanner with two months between each scan. Four additional scans ensued each time, with mAs reduced to 50 %, 25 %, 10 %, and 5 %. All scans were reconstructed ADMIRE levels 2 (IR2) and a novel DLD algorithm, resulting in 280 datasets. Objective image quality (CT numbers stability, noise, and contrast-to-noise ratio) was measured via consistent regions of interest. Three radiologists independently rated all possible dataset combinations per time point for subjective image quality (-1 = inferior, 0 = equal, 1 = superior). The points were averaged for a semiquantitative score, and inter-rater agreement was measured using Spearman's correlation coefficient and adequately corrected mixed-effects modeling analyzed objective and subjective image quality. RESULTS: Neither dose-reduction nor reconstruction method negatively impacted CT number stability (p > 0.999). In objective image quality assessment, the lowest radiation dose achievable by DLD when comparing noise (p = 0.544) and CNR (p = 0.115) to 100 % IR2 was 25 %. Overall, inter-rater agreement of the subjective image quality ratings was strong (r ≥ 0.69, mean 0.93 ± 0.05, 95 % CI 0.92-0.94; each p < 0.001), and subjective assessments corroborated that DLD at 25 % radiation dose was comparable to 100 % IR2 in image quality, sharpness, and contrast (p ≥ 0.281). CONCLUSIONS: The DLD algorithm can achieve image quality comparable to the standard IR method but with a significant dose reduction of up to 75%. This suggests a promising avenue for lowering patient radiation exposure without sacrificing diagnostic quality.


Assuntos
Aprendizado Profundo , Humanos , Animais , Suínos , Doses de Radiação , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/métodos , Algoritmos , Modelos Animais
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA