RESUMO
BACKGROUND: NobleStitch EL is a novel suture-based technique used for patent foramen ovale (PFO) closure and an alternative to traditional double-disc devices without the need for antithrombotic therapy. However, successful closure rates are still unknown, and certain anatomies may be unfavorable for successful closure. AIMS: We assessed the efficacy of the NobleStitch EL and sought to identify patient-related anatomical features associated with successful suture-based closure. METHODS: We included 55 patients who underwent PFO closure with the NobleStitch EL in The Netherlands and Switzerland. Successful closure was defined as residual right-to-left shunt grade ≤1 with Valsalva maneuver at a cardiac ultrasound. Predefined possible anatomical determinants for effective closure included PFO length, atrial septal aneurysm, PFO entry- and exit diameter. RESULTS: Successful closure was achieved in 33 patients (60%). The PFO length was shorter in patients with successful closure compared to unsuccessful closure with a median length of 9.6 mm (IQR 8.0-15.0) versus 13.3 mm (IQR 11.4-18.6) on preprocedural ultrasound (p = 0.041) and 9.9 mm (IQR 8.0-13.1) versus 12.5 mm (IQR 9.7-15.4) on angiography (p = 0.049). Additionally, the PFO exit diameter and PFO volume were smaller in patients with successful closure than unsuccessful closure, with a mean diameter of 7.0 ± 3.1 mm versus 9.5 ± 3.8 mm (p = 0.015) and a median volume of 381 mm3 (IQR 286-894) versus 985 mm3 (IQR 572-1550) (p = 0.016). CONCLUSION: In our study cohort, the successful PFO closure rate using NobleStitch EL was relatively low (60%). With this alternative procedure, patients with a small PFO driven by a short PFO tunnel length and small exit diameter seem to be eligible for successful suture-based closure.
Assuntos
Forame Oval Patente , Acidente Vascular Cerebral , Humanos , Forame Oval Patente/diagnóstico por imagem , Forame Oval Patente/terapia , Forame Oval Patente/complicações , Resultado do Tratamento , Ecocardiografia Transesofagiana , Cateterismo Cardíaco , SuturasAssuntos
Doenças das Artérias Carótidas , Poluição Ambiental , Microplásticos , Placa Aterosclerótica , Humanos , Microplásticos/análise , Nanopartículas/análise , Placa Aterosclerótica/química , Placa Aterosclerótica/patologia , Doenças das Artérias Carótidas/patologia , Fatores de Risco de Doenças Cardíacas , Salas CirúrgicasRESUMO
INTRODUCTION: Lipoprotein(a) [Lp(a)] is linked to higher risks of atherosclerotic cardiovascular disease (ASCVD). Current guideline recommendations are quite liberal on measuring Lp(a) (Class IIa, Level C), and may lead to underuse among (interventional) cardiologists. AREAS COVERED: This case-based narrative review outlines four clinical cases of patients with elevated Lp(a) to illustrate its pathophysiological impact on coronary artery disease (CAD). The expert consensus statements from the American Heart Association (AHA) and European Atherosclerosis Society (EAS) served as the basis of this review. More recent publications, from 2023 to 2024, were accessed through the MEDLINE online library. EXPERT OPINION: We highlighted the importance of routine Lp(a) measurement in identifying patients at high risk for atherosclerosis, necessitating potent risk mitigation. Measuring Lp(a) helps clinicians identify which patients are at highest residual risk, who require potent pharmacological treatment and special attention during catheter interventions. As noninvasive and advanced intravascular imaging modalities evolve, future catheterization laboratories will integrate advanced imaging, diagnostics, and treatment, facilitating tailored patient care. Knowing Lp(a) levels is crucial in this context. While Lp(a)-lowering drugs are currently investigated in clinical trials, it is of paramount importance to know Lp(a) levels and strive toward aggressive management of other modifiable risk factors in patients with elevated Lp(a) and established symptomatic CAD being diagnosed or treated in catheterization laboratories.
Assuntos
Doença da Artéria Coronariana , Lipoproteína(a) , Humanos , Aterosclerose/sangue , Aterosclerose/diagnóstico , Biomarcadores/sangue , Doença da Artéria Coronariana/sangue , Doença da Artéria Coronariana/diagnóstico , Lipoproteína(a)/sangue , Guias de Prática Clínica como Assunto , Recidiva , Medição de Risco/métodos , Medição de Risco/normasRESUMO
OBJECTIVES: This study sought to present an angiography-based computational model for serial assessment of superficial wall strain (SWS, dimensionless) of de-novo coronary stenoses treated with either bioresorbable scaffold (BRS) or drug-eluting stent (DES). BACKGROUND: A novel method for SWS allows the assessment of the mechanical status of arteries in-vivo, which may help for predicting cardiovascular outcomes. METHODS: Patients with arterial stenosis treated with BRS (n = 21) or DES (n = 21) were included from ABSORB Cohort B1 and AIDA trials. The SWS analyses were performed along with quantitative coronary angiography (QCA) at pre-PCI, post-PCI, and 5-year follow-up. Measurements of QCA and SWS parameters were quantified at the treated segment and adjacent 5-mm proximal and distal edges. RESULTS: Before PCI, the peak SWS on the 'to be treated' segment (0.79 ± 0.36) was significantly higher than at both virtual edges (0.44 ± 0.14 and 0.45 ± 0.21; both p < 0.001). The peak SWS in the treated segment significantly decreased by 0.44 ± 0.13 (p < 0.001). The surface area of high SWS decreased from 69.97mm2 to 40.08mm2 (p = 0.002). The peak SWS in BRS group decreased to a similar extent (p = 0.775) from 0.81 ± 0.36 to 0.41 ± 0.14 (p < 0.001), compared with DES group from 0.77 ± 0.39 to 0.47 ± 0.13 (p = 0.001). Relocation of high SWS to device edges was often observed in both groups after PCI (35 of 82 cases, 41.7 %). At follow-up of BRS, the peak SWS remained unchanged compared to post-PCI (0.40 ± 0.12 versus 0.36 ± 0.09, p = 0.319). CONCLUSION: Angiography-based SWS provided valuable information about the mechanical status of coronary arteries. Device implantation led to a significant decrease of SWS to a similar extent with either polymer-based scaffolds or permanent metallic stents.
Assuntos
Stents Farmacológicos , Intervenção Coronária Percutânea , Humanos , Everolimo , Implantes Absorvíveis , Intervenção Coronária Percutânea/efeitos adversos , Vasos Coronários/diagnóstico por imagem , Angiografia Coronária , Resultado do Tratamento , Desenho de PróteseRESUMO
BACKGROUND/PURPOSE: The Lipid Rich Plaque (LRP) study demonstrated the association between coronary plaque lipid content and outcomes. In this LRP substudy, we assessed the impact of optimal medical therapy (OMT) on the occurrence of non-culprit major adverse cardiac events (NC-MACE). Advanced intracoronary imaging modalities are able to identify patients with vulnerable coronary lesion morphology associated with future events. METHODS/MATERIALS: A total of 1270 patients who underwent cardiac catheterization for suspected coronary artery disease (CAD) with evaluable maxLCBI4mm in non-culprit vessels and known medical therapy after discharge were followed for 2 years. OMT was defined as the use of a statin and dual antiplatelet therapy (DAPT). RESULTS: Among the 1270 patients included in this substudy, 1110 (87.7%) had PCI for an index event, and 1014 (80%) patients received OMT. Estimated cumulative incidence functions of NC-MACE did not differ significantly between patients treated with or without OMT (log-rank p-value = 0.876). In patients labeled high risk (maxLCBI4mm > 400), cumulative incidence function also did not differ between patients treated with vs without OMT (log-rank p-value = 0.19). CONCLUSIONS: In the current LRP analysis, we could not identify a beneficial effect of OMT in the reduction of NC-MACE rate, even in patients with high-risk plaques, during 24-month follow-up.
Assuntos
Doença da Artéria Coronariana , Inibidores de Hidroximetilglutaril-CoA Redutases , Intervenção Coronária Percutânea , Placa Aterosclerótica , Doença da Artéria Coronariana/complicações , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/terapia , Humanos , Inibidores de Hidroximetilglutaril-CoA Redutases/efeitos adversos , Lipídeos , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/métodos , Placa Aterosclerótica/patologia , Inibidores da Agregação Plaquetária/efeitos adversos , Resultado do TratamentoRESUMO
BACKGROUND: Absorb bioresorbable vascular scaffold (BVS)-related events have been reported between 1 and 3 years - the period of active scaffold bioresorption. Data on the performance of the Absorb BVS in daily clinical practice beyond this time point are scarce. AIMS: This report aimed to provide the final five-year clinical follow-up of the Absorb BVS in comparison with the XIENCE everolimus-eluting stent (EES). In addition, we evaluated the effect of prolonged dual antiplatelet therapy (DAPT) administration on events in the scaffold group. METHODS: AIDA was a multicentre, investigator-initiated, non-inferiority trial, in which 1,845 unselected patients with coronary artery disease were randomly assigned to either the Absorb BVS (n=924) or the XIENCE EES (n=921). Target vessel failure (TVF), a composite of cardiac death, target vessel myocardial infarction or target vessel revascularisation, was the primary endpoint. Scaffold thrombosis cases were matched with controls and tested for the effect of prolonged DAPT. RESULTS: Up to five-year follow-up, there was no difference in TVF between the Absorb BVS (17.7%) and the XIENCE EES (16.1%) (hazard ratio [HR] 1.31, 95% confidence interval [CI]: 0.90-1.41; p=0.302). Definite or probable device thrombosis (DT) occurred in 43 patients (4.8%) in the scaffold group compared to 13 patients (1.5%) in the stent group (HR 3.32, 95% CI: 1.78-6.17; p<0.001). DT between 3 and 4 years occurred six times in the Absorb arm versus three times in the XIENCE arm. Between 4 and 5 years, the incidence was three versus two, respectively. Of those three DT in the scaffold group, two occurred in XIENCE EES-treated lesions. The odds ratio of scaffold thrombosis in patients on DAPT compared to off DAPT throughout five-year follow-up was 0.36 (95% CI: 0.15-0.86). CONCLUSIONS: The excess risk of the Absorb BVS on late adverse events, in particular device thrombosis, in routine PCI continues up to 4 years and seems to plateau afterwards. Clinical Trial Registration ClinicalTrials.gov: NCT01858077.