Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 88
Filtrar
Mais filtros

País/Região como assunto
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Ann Vasc Surg ; 23(3): 412.e1-4, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-18774688

RESUMO

An 88-year-old woman with hypertension, chronic vein insufficiency, and repeated cellulites in the right lower extremity was admitted to our hospital with a new episode of right leg inflammation and edema associated with fever and leukocytosis. Due to unilateral enlargement of the leg and D-simer levels of 1000 microg/mL, a concomitant deep venous thrombosis was suspected and ultrasonography was performed. Color duplex-scanning found normal flow in the right deep leg veins but revealed an 11-cm-diameter popliteal artery aneurysm. A computed tomography scan confirmed the diagnosis and revealed a large perianeurysmal hematoma, and angiography provided evidence of perianeurysmal bleeding. The patient was unfit for open surgery, so an endovascular approach under local anesthesia was elected. The aneurysm was successfully excluded with an endograft, and 15 months after surgery, the patient is alive and had an uneventful postoperative course.


Assuntos
Aneurisma Roto/cirurgia , Implante de Prótese Vascular , Artéria Poplítea/cirurgia , Idoso de 80 Anos ou mais , Aneurisma Roto/patologia , Feminino , Hematoma/cirurgia , Hemorragia/cirurgia , Humanos , Artéria Poplítea/patologia , Tomografia Computadorizada por Raios X , Resultado do Tratamento , Ultrassonografia Doppler em Cores
2.
Ann Vasc Surg ; 23(3): 410.e17-20, 2009.
Artigo em Inglês | MEDLINE | ID: mdl-18502607

RESUMO

Prosthetic infection is one of the most serious complications of vascular surgery, and its treatment remains a surgical challenge. Good results have been reported using in situ replacement with arterial allografts, but late degeneration of the graft itself may necessitate further repair. We report a case of rupture and pseudoaneurysm formation of an iliac artery homograft urgently treated by endoluminal grafting with complete and immediate exclusion of the sac without complications. At 6-month follow-up angio-computed tomography showed patency of the vascular stent graft without leak evidence. Two years and 6 months after the procedure, the patient is well and alive.


Assuntos
Falso Aneurisma/cirurgia , Aneurisma Roto/cirurgia , Implante de Prótese Vascular/efeitos adversos , Prótese Vascular/efeitos adversos , Criopreservação , Artéria Ilíaca/transplante , Infecções Relacionadas à Prótese/cirurgia , Procedimentos Cirúrgicos Vasculares/efeitos adversos , Idoso de 80 Anos ou mais , Falso Aneurisma/diagnóstico por imagem , Falso Aneurisma/etiologia , Aneurisma Roto/diagnóstico por imagem , Aneurisma Roto/etiologia , Antibacterianos/uso terapêutico , Aneurisma Aórtico/cirurgia , Implante de Prótese Vascular/instrumentação , Remoção de Dispositivo , Humanos , Aneurisma Ilíaco/cirurgia , Masculino , Desenho de Prótese , Infecções Relacionadas à Prótese/etiologia , Infecções Relacionadas à Prótese/microbiologia , Reoperação , Tomografia Computadorizada Espiral , Transplante Homólogo , Resultado do Tratamento
3.
Vasa ; 38(4): 334-7, 2009 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-19998253

RESUMO

BACKGROUND: Despite the theoretical effectiveness of the Angio-Seal closure device to control bleeding after arterial puncture it can increase the risk of ischemia. OBJECTIVES: To describe arterial lesions caused by the device, surgical techniques needed to repair those lesions and surgical outcome in patients who underwent surgery for arterial ischemia after heart catheterization. PATIENTS AND METHODS: Seven patients underwent surgery over a period of 12 months at our institution. Five patients underwent emergency surgery and two a delayed procedure. The cause of ischemia was dissection of an atheroma plaque at the puncture site in four cases, dissection of the superficial femoral artery in one case, thrombosis of the common femoral artery in one case, and plication of the posterior arterial wall in one case. Arterial repair in these patients required the insertion of a vascular graft in three cases, endarterectomy plus angioplasty in two cases, endarterectomy plus graft interposition plus thrombectomy of the superficial femoral artery in one case and endarterectomy plus femoropopliteal bypass in one case. RESULTS: Treatment was successful in all patients. Mean follow up was 7.6 months (range 5-11 months). During the study period one patient died due to cardiopathy. No patients had to be re-operated and no limb losses were recorded. All the patients were asymptomatic from a vascular point of view with normal active lives for their age. CONCLUSIONS: Surgical repair is effective, although, generally, it is not restricted to a simple thrombectomy, requiring the use of different arterial repair techniques.


Assuntos
Cateterismo Cardíaco/efeitos adversos , Artéria Femoral/cirurgia , Hemorragia/prevenção & controle , Técnicas Hemostáticas/efeitos adversos , Isquemia/cirurgia , Extremidade Inferior/irrigação sanguínea , Trombose/cirurgia , Procedimentos Cirúrgicos Vasculares , Idoso , Idoso de 80 Anos ou mais , Angioplastia , Implante de Prótese Vascular , Endarterectomia , Desenho de Equipamento , Feminino , Hemorragia/etiologia , Técnicas Hemostáticas/instrumentação , Humanos , Isquemia/etiologia , Masculino , Pessoa de Meia-Idade , Punções , Trombectomia , Trombose/etiologia , Fatores de Tempo , Resultado do Tratamento
4.
J Hosp Infect ; 70(1): 48-52, 2008 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-18621436

RESUMO

On 2 November 1999, one of the main hospital façades adjoining cardiovascular surgery collapsed in a 900-bed teaching hospital in Santander, Spain. The purpose of this study was to determine whether the accident affected the safety of patients by increasing the risk for nosocomial and surgical site infections (SSI). Measures for the prevention of nosocomial infections were immediately reinforced. A total of 217 consecutive patients were operated on before 2 November 1999, with another 296 after this date. Patients in both study periods showed similar severity of illness, complexity of surgical procedure and length of hospital stay. The overall rate of nosocomial infection before and after the accident was 28.1% and 24.7%, respectively (P=0.381). The rates of respiratory infection, urinary infection and bacteraemia were also similar. A statistically significant reduction in the SSI rate in the second period was observed (14.8% vs 4.4%, P=0.008). The collapse of the façade was not associated with any increase in nosocomial infection rates, but there was a significant reduction of SSI rates in relation to intensive infection control measures implemented after the collapse.


Assuntos
Infecção Hospitalar/epidemiologia , Infecção da Ferida Cirúrgica/epidemiologia , Cirurgia Torácica , Idoso , Bacteriemia/epidemiologia , Feminino , Hospitais de Ensino , Humanos , Tempo de Internação , Masculino , Prevalência , Infecções Respiratórias/epidemiologia , Índice de Gravidade de Doença , Espanha , Infecções Urinárias/epidemiologia
5.
Arch Intern Med ; 160(8): 1185-91, 2000 Apr 24.
Artigo em Inglês | MEDLINE | ID: mdl-10789613

RESUMO

BACKGROUND: Since publication of the Duke criteria for diagnosing endocarditis, several articles have confirmed their sensitivity when native and prosthetic valves are considered together. OBJECTIVES: To compare the differences between the older von Reyn criteria and the Duke criteria in prosthetic valve endocarditis only, and to determine if the latter's sensitivity could be improved by adding 2 minor criteria: new-onset heart failure and presence of conduction disturbances. METHODS: We retrospectively evaluated 93 episodes of prosthetic valve endocarditis from January 1986 to January 1998 in a teaching hospital, and then analyzed the 76 surgically confirmed episodes to compare the differences between the von Reyn and Duke diagnostic criteria. RESULTS: The von Reyn criteria rejected the diagnosis in 16 of the confirmed episodes, compared with 1 diagnosis missed by the Duke criteria and 1 missed using our suggested modifications. Definite diagnosis (Duke) was established in 60 episodes, compared with a diagnosis of probable (von Reyn) in 36 episodes (P<.001). Our modifications improved the sensitivity of the Duke criteria, diagnosing 70 episodes as definite (P = .02). CONCLUSIONS: As was the case with native valve endocarditis, the Duke criteria proved to be more sensitive than the von Reyn criteria in prosthetic valve endocarditis. The addition of 2 minor criteria (new-onset heart failure and presence of conduction disturbances) could improve the diagnostic sensitivity of the Duke criteria.


Assuntos
Endocardite Bacteriana/diagnóstico , Próteses Valvulares Cardíacas/efeitos adversos , Infecções Relacionadas à Prótese/diagnóstico , Adulto , Endocardite Bacteriana/etiologia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Sensibilidade e Especificidade
6.
Thromb Haemost ; 79(6): 1126-9, 1998 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-9657436

RESUMO

Based on genetic variability, structural differences in the glycoprotein IIb/IIIa platelet receptor for adhesive proteins result in individual differences in the thrombogenicity of platelets. Recent studies suggest a controversial association between a genetic polymorphism of the glycoprotein IIIa gene (PlA2) and the risk of coronary artery disease. In our study, the prevalence of the PlA2 allele in a group of patients undergoing percutaneous coronary revascularization was 37%, a value significantly higher than in controls [13%, odds ratio (OR) = 3.93, 95% CI, 1.84 to 8.53] suggesting a significant association between this polymorphism and documented coronary stenosis, which is strongest among <60 years old patients (OR = 12.30, 95% CI, 2.98 to 70.93). This polymorphism represents an inherited risk factor for severe cardiovascular disease due to coronary occlusion.


Assuntos
Doença das Coronárias/genética , Complexo Glicoproteico GPIIb-IIIa de Plaquetas/genética , Polimorfismo Genético , Idoso , Consumo de Bebidas Alcoólicas/epidemiologia , Alelos , Angioplastia Coronária com Balão , Terapia Combinada , Comorbidade , Doença das Coronárias/epidemiologia , Doença das Coronárias/cirurgia , Doença das Coronárias/terapia , Diabetes Mellitus/epidemiologia , Feminino , Fibrinogênio/análise , Frequência do Gene , Genótipo , Humanos , Hipertensão/epidemiologia , Lipídeos/sangue , Masculino , Pessoa de Meia-Idade , Reação em Cadeia da Polimerase , Polimorfismo de Fragmento de Restrição , Prevalência , Fatores de Risco , Fumar/epidemiologia , Stents
7.
J Thorac Cardiovasc Surg ; 112(1): 59-68, 1996 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-8691886

RESUMO

Between January 1989 and August 1992, 612 CarboMedics mechanical prostheses (CarboMedics, Inc., Austin, Tex.) (295 mitral, 308 aortic, and 9 tricuspid) were implanted in 504 patients: 189 patients had isolated mitral valve replacement, 209 had isolated aortic valve replacement, and 106 had multiple valve replacement. The total follow-up was 1182 patient-years. The hospital mortality rate was 7.4% for mitral valve replacement, 5.3% for aortic valve replacement, and 13.2% for multiple valve replacement. Linearized rates for the different complications for mitral valve replacement, aortic valve replacement, and multiple valve replacement (in events per 100 patient-years) were, respectively, as follows: late mortality, 2.6 +/- 0.8, 1.5 +/- 0.5, and 3.9 +/- 1.3; thromboembolism [correction of thromboembolim], 3.7 +/- 0.9, 3.1 +/- 0.8, and 3.9 +/- 1.3; valve thrombosis, 0.5 +/- 0.3 for mitral valve replacement and 0.4 +/- 0.4 for multiple valve replacement; anticoagulant-related hemorrhage, 2.8 +/- 0.8, 1.9 +/- 0.6, and 2.6 +/- 1.1; nonstructural dysfunction, 1.6 +/- 0.6, 0.8 +/- 0.4, and 3.5 +/- 1.2; and reoperation, 1.1 +/- 0.5, 0.4 +/- 0.3, and 3.1 +/- 1.1. Actuarial estimates of freedom from the different complications for mitral valve replacement, aortic valve replacement, and multiple valve replacement (at 5 years of follow-up for mitral valve replacement and aortic valve replacement and 4.5 years for multiple valve replacement) were, respectively, as follows: overall death, 83% +/- 4%, 89% +/- 2%, and 76% +/- 4%; thromboembolism or valve thrombosis, 88% +/- 3%, 91% +/- 2%, and 86% +/- 5%; anticoagulant-related hemorrhage, 89% +/- 3%, 95% +/- 2%, and 90% +/- 5%; nonstructural dysfunction, 97% +/- 1%, 98% +/- 1%, and 91% +/- 3%; and reoperation, 96% +/- 2%, 99% +/- 1%, and 87% +/- 5%. There were no instances of prosthetic structural dysfunction. The performance of the CarboMedics valve is satisfactory at 5 years of follow-up but thromboembolic and hemorrhagic phenomena are still serious complications of mechanical prostheses.


Assuntos
Próteses Valvulares Cardíacas , Adolescente , Adulto , Idoso , Valva Aórtica/cirurgia , Mortalidade Hospitalar , Humanos , Pessoa de Meia-Idade , Valva Mitral/cirurgia , Complicações Pós-Operatórias , Desenho de Prótese , Reoperação , Estudos Retrospectivos , Resultado do Tratamento
8.
J Thorac Cardiovasc Surg ; 89(1): 136-41, 1985 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-3965810

RESUMO

Ten patients were treated for skin erosion and exposure of chronically implanted pacemakers. The pulse generators had been implanted either subcutaneously or in the subpectoral, submammary location. All patients were treated either by primary or secondary relocation of the pulse generator to deeper subfascial planes. Pacemakers relocated primarily to subfacial planes healed without resurfacing. Those pacemakers relocated to other superficial planes resurfaced but healed in a second subfascial translocation. Bacteriologic studies on these patients revealed that the organisms cultured or antibiotics utilized did not influence the fate of the relocated pulse generator. The subfascial location was the only determinant of the ultimate healing of the exposed pacemaker. We conclude that subfascial relocation of well-functioning pacemaker generators should be considered as an alternative to complete replacement of the unit.


Assuntos
Fasciotomia , Corpos Estranhos/cirurgia , Marca-Passo Artificial/efeitos adversos , Reoperação , Procedimentos Cirúrgicos Operatórios , Adulto , Idoso , Eletrodos Implantados/efeitos adversos , Infecções por Enterobacteriaceae/tratamento farmacológico , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Reoperação/métodos , Dermatopatias Infecciosas/tratamento farmacológico , Dermatopatias Infecciosas/etiologia , Dermatopatias Infecciosas/cirurgia , Infecções Estafilocócicas/tratamento farmacológico , Procedimentos Cirúrgicos Operatórios/métodos
9.
J Thorac Cardiovasc Surg ; 110(3): 688-95; discussion 695-6, 1995 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-7564435

RESUMO

Manufacturing factors have seldom been implicated as a direct cause of structural deterioration of valvular bioprostheses; this phenomenon has generally been considered to be of a host-dependent origin. We analyzed the clinical and pathologic data from 12 Carpentier-Edwards mitral bioprostheses removed from 12 patients because of severe dysfunction and showing detachment of the porcine aortic wall from the stent in one commissure or more. These 12 prostheses were part of a group of 92 such valves that were explanted and displayed structural deterioration. They belong to a population of 405 Carpentier-Edwards bioprostheses implanted in the mitral position in our institution between May 1978 and November 1988. The patients included three men and nine women with a mean age of 54 +/- 13 years. One patient had a history of chronic renal failure, and two had systemic hypertension. Prosthesis sizes were 29, 31, and 33 mm (n = 4 for each size). The models of the valves were 6625 (n = 8) and 6650 (n = 4). Mean duration of implantation of the prostheses was 99 +/- 27 months (52 to 136 months) and did not differ depending on the model. There was no significant clustering of commissural detachments depending on valve size, year of implantation, or gender of the patient. No similar phenomenon was observed among 76 explanted aortic Carpentier-Edwards bioprostheses with structural deterioration from a population of 441 valves implanted during the same time frame. Native porcine aortic roots (n = 5) and aortic Carpentier-Edwards bioprostheses explanted because of structural deterioration (n = 4) were used as controls for comparison. Macroscopic examination showed single commissural dehiscence in 10 patients and double in two. Radiology disclosed no or mild mineralization in eight valves and no calcium in the area of aortic wall dehiscence, except for heavily calcified valves. Light microscopy evidenced a significant thinning of the aortic wall at the paracommissural level of mitral bioprostheses (351 +/- 68 microns) compared with either aortic bioprostheses (526 +/- 59 microns; p < 0.01) or control native porcine aortic roots (419 +/- 50 microns; p < 0.01). No difference was found in terms of aortic wall thickness between detached (322 +/- 42 microns) and intact (366 +/- 74 microns) commissures in mitral bioprostheses.(ABSTRACT TRUNCATED AT 400 WORDS)


Assuntos
Bioprótese , Próteses Valvulares Cardíacas , Adulto , Idoso , Aorta/patologia , Calcinose/patologia , Feminino , Doenças das Valvas Cardíacas/patologia , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/patologia , Valva Mitral/cirurgia , Falha de Prótese , Reoperação , Estudos Retrospectivos , Stents
10.
J Thorac Cardiovasc Surg ; 97(1): 98-103, 1989 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-2642992

RESUMO

Surgical repair of ruptured or elongated chordae tendineae of the mitral valve is one of the most complex reconstructive techniques in cardiac surgery. Various surgical procedures have been described to repair chordal abnormalities of the anterior leaflet of the mitral valve with unpredictable results. Mitral valve replacement is usually recommended in that situation. This report describes a simple repair technique that we have devised. We resected one or two marginal chordae of the anterior leaflet of the mitral valve in 35 sheep and replaced them with a double-armed, pledget-supported, expanded polytetrafluoroethylene suture. The 30 surviving animals were studied hemodynamically and were electively put to death 3, 6, 9, 18, and 24 months after the operation. Mitral insufficiency did not develop in any of the sheep. All specimens had a normal mitral valve without thrombosis. The polytetrafluoroethylene suture remained pliable and was incorporated into the anterior leaflet and papillary muscle. Scanning and transmission electron microscopy showed that the suture was completely covered by a sheath of tissue with a collagen structure remarkably similar to that of a native chorda. Calcification was not detected in the new chordae. This reproducible and safe technique may considerably simplify the difficult repair of chordal abnormalities.


Assuntos
Cordas Tendinosas/cirurgia , Próteses Valvulares Cardíacas , Politetrafluoretileno , Suturas , Animais , Cordas Tendinosas/ultraestrutura , Colágeno/análise , Hemodinâmica , Valva Mitral/fisiopatologia , Valva Mitral/cirurgia , Ovinos , Técnicas de Sutura
11.
J Thorac Cardiovasc Surg ; 112(4): 908-13, 1996 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-8873716

RESUMO

A total of 970 adult patients undergoing cardiovascular operations during a 1-year period were eligible for a case-control study on the risk factors for nosocomial infection. Cases were defined as patients in whom a postoperative infection developed. Every case was paired with one uninfected subject. Nosocomial infection occurred in 89 (9.2%) patients. A total of 120 episodes of infection were diagnosed (1.3 episodes per patient). The infection ratio was 12.4%. Surgical site infection was the most common (5.6%), followed by pneumonia (3.2%), urinary tract infection requiring the use of intravenous antibiotics (1.8%), deep surgical site (0.9%), and bacteremia (0.7%). Advanced age, urgent intervention, duration of surgical procedure, blood transfusion, and use of invasive procedures (urinary catheter, chest tubes, nasogastric tube passage) were significantly associated with infection in the bivariate analysis. Nosocomial infection resulted in a significant increase in the length of hospital stay. Cases showed an almost fivefold greater risk of death than controls (odds ratio, 4.73; 95% confidence interval, 1.11 to 6.83; p = 0.009). Age older than 65 years, female sex, and mode of surgical intervention were selected in the multivariate analysis for patients undergoing cardiac operations, whereas general anesthesia or assisted ventilation, central venous catheter, and blood transfusion were the variables selected for patients undergoing operation for vascular disorders. In summary, the recognition of risk factors for postoperative infection in patients undergoing cardiovascular surgical procedures may contribute to improve their prognosis and to more organized surveillance and control activities in the hospital environment.


Assuntos
Procedimentos Cirúrgicos Cardíacos , Infecção Hospitalar/etiologia , Complicações Pós-Operatórias , Procedimentos Cirúrgicos Vasculares , Idoso , Estudos de Casos e Controles , Doença das Coronárias/cirurgia , Feminino , Doenças das Valvas Cardíacas/cirurgia , Humanos , Tempo de Internação , Masculino , Análise Multivariada , Fatores de Risco
12.
J Thorac Cardiovasc Surg ; 80(6): 849-60, 1980 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-7431984

RESUMO

In an attempt to clarify the indications for tricuspid valve operations, we studied 150 patients who had preoperative and postoperative full catheterization including biventriculography. Seventy-eight patients had organic and 72 had functional tricuspid insufficiency (TI). One hundred nineteen underwent tricuspid repair (46 commissurotomies and 115 annulopasties), and in 31 the tricuspid disease was surgically ignored. Ninety seven percent of all patients with hemodynamically correct left-side repair were in Class I or II, regardless of the state of the tricuspid valve. Repair of lesions on the left side determined the postoperative cardiac index. In the "repaired group," 38% had residual gradients and 30% residual TI. Eighty percent of patients with low postoperative pulmonary resistance had no TI, compared with 53% with high pulmonary resistance. In the "ignored group," all 14 patients with organic disease had residual TI, as did nine of 17 with functional disease but with elevated pulmonary resistance. The right ventricular end-diastolic volume (RVEDV) decreased 37% in the "repaired" (p < 0.001) and 36% in the "ignored" group (p < 0.01) if tricuspid competence was achieved, but remained high if TI persisted. Because of these data, which emphasize the need for an early and correct repair of the left-side lesions, we believe that (1) functional TI can be ignored only in patients with predictable and significant reduction in pulmonary resistance and (2) organic disease must be repaired.


Assuntos
Hemodinâmica , Insuficiência da Valva Tricúspide/mortalidade , Valva Tricúspide/cirurgia , Adolescente , Adulto , Idoso , Débito Cardíaco , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Circulação Pulmonar , Insuficiência da Valva Tricúspide/fisiopatologia , Resistência Vascular
13.
J Thorac Cardiovasc Surg ; 89(3): 451-5, 1985 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-3974281

RESUMO

This experimental study summarizes our experience with the use of a new polytetrafluoroethylene surgical membrane as a pericardial substitute in 24 dogs. Group I consists of 10 dogs who underwent simple pericardial closure with this membrane, and in Group II, 14 dogs had pericardial closure with this membrane after cardiac procedures. There were three early deaths. Two dogs that had undergone an associated right heart procedure developed endocarditis at 4 and 7 months, respectively. Postmortem examinations were performed in all 21 surviving dogs. The pericardial membranes were found to be acellular and to have maintained their initial characteristics. The epicardium was normal and the coronary arteries easily visible. Seven of the eight 0.2 mm thick membranes caused filmy pericardial adhesions. None of the 0.1 mm thick membranes formed adhesions or had any structural change. We conclude that this new 0.1 mm thick polytetrafluoroethylene surgical membrane should be clinically tested to see if it will reduce or eliminate pericardial adhesions and facilitate cardiac reoperation.


Assuntos
Membranas Artificiais , Pericárdio/cirurgia , Politetrafluoretileno , Animais , Cães , Pericárdio/patologia , Propriedades de Superfície
14.
J Thorac Cardiovasc Surg ; 90(2): 278-80, 1985 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-4021528

RESUMO

This report provides retrospective follow-up data on 88 patients who received an Ionescu-Shiley bovine pericardial valve in the aortic position between August, 1977, and June. 1980. Seven instances of primary tissue degeneration occurred in seven of the 65 patients followed up until June, 1984. Cumulative duration of follow-up was 335.5 patient-years. The linearized incidence of primary tissue failure was 2.08% per patient-year. The actuarial rate of freedom from valve failure for patients with an Ionescu-Shiley valve in aortic position was 79% +/- 8% at 7 years of follow-up. This series shows a higher incidence of primary tissue failure with this prosthesis than with the glutaraldehyde-preserved porcine xenograft in the aortic position at 7 years' follow-up.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas , Adolescente , Adulto , Valva Aórtica , Bioprótese/efeitos adversos , Falha de Equipamento , Seguimentos , Próteses Valvulares Cardíacas/efeitos adversos , Humanos , Pessoa de Meia-Idade , Reoperação , Fatores de Tempo
15.
J Thorac Cardiovasc Surg ; 111(1): 211-7, 1996 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-8551768

RESUMO

Sixty-two patients with rheumatic mitral valve disease (mean age 42.2 +/- 10.2 years) underwent repair of chordae tendineae between June 1974 and May 1994. Chordal shortening was done in 38 patients, fenestration in 17, resection of secondary chordae in 3, replacement in 2, and transposition in 2. In 41 patients, mitral commissurotomy was also done. Ring annuloplasty was done in all patients. The mean follow-up was 10.2 years (range 2 months to 20 years). The completeness of follow-up during the closing interval (January to July 1994) was 100%. Hospital mortality occurred in four patients (6.5%) and nine patients died during the late follow-up. The actuarial survival curve at 20 years was 65.8% +/- 10%. Six patients with mitral valve dysfunction (restenosis 4, insufficiency 2) and one with aortic valve dysfunction (structural deterioration of bioprosthesis) underwent reoperation. The actuarial curve of freedom from reoperation at 20 years for mitral valve dysfunction was 73.1% +/- 10.5%. In the 49 surviving patients, a Doppler echographic study during the closing interval showed a mean mitral valve area of 1.9 +/- 0.3 cm2. In the 43 patients with a repaired native valve, absent or trivial mitral regurgitation was documented in 35 and mild or moderate regurgitation in 8. In conclusion, repair of chordae tendineae in rheumatic mitral valve disease when feasible is a stable and safe procedure with a low prevalence of reoperation. However, the type of reconstructive operation and experience of the surgical team are major considerations in successful repair of the mitral valve.


Assuntos
Cordas Tendinosas/cirurgia , Insuficiência da Valva Mitral/cirurgia , Estenose da Valva Mitral/cirurgia , Cardiopatia Reumática/cirurgia , Adulto , Feminino , Seguimentos , Humanos , Masculino , Valva Mitral/cirurgia , Insuficiência da Valva Mitral/epidemiologia , Insuficiência da Valva Mitral/etiologia , Estenose da Valva Mitral/epidemiologia , Estenose da Valva Mitral/etiologia , Reoperação , Estudos Retrospectivos , Análise de Sobrevida , Taxa de Sobrevida , Fatores de Tempo , Resultado do Tratamento
16.
J Thorac Cardiovasc Surg ; 101(5): 871-80, 1991 May.
Artigo em Inglês | MEDLINE | ID: mdl-2023444

RESUMO

Valve-related morbidity and mortality after heart valve replacement with the Hancock I porcine bioprosthesis has been retrospectively analyzed. From June 1974 through December 1976, 253 Hancock I bioprostheses (150 mitral and 103 aortic) were inserted in 220 selected patients who survived the operation and had follow-up until June 1989 (mean follow-up 13.5 years, with an accumulative follow-up of 2956.4 patient-years). One hundred seventeen patients had mitral valve replacement, 70 had aortic valve replacement, and 33 had combined mitral and aortic valve replacement. There were 27 thromboembolic events. The probability of being free from thromboembolism at 14 years was 81.0% +/- 7.4% for the mitral valve replacement group, 85.4% +/- 6.7% for the aortic group, and 67.1% +/- 18.4% for the mitral-aortic group. Fifteen episodes of prosthetic valve endocarditis occurred. There were 10 instances of nonstructural dysfunction (paravalvular leaks) in seven mitral valves (4.6%) and in three aortic valves (2.9%). One hundred twenty-two bioprostheses in 106 patients resulted in structural deterioration. The probability of freedom from structural deterioration at 14 years was 37.2% +/- 3.9% for the mitral group, 43.9% +/- 7.1% for the aortic group, and 30.1% +/- 8.9% for the mitral-aortic group. The logistic regression analysis between age at the time of operation and bioprosthetic life (structural deterioration-free period) demonstrates a linear regression curve (r = 0.53). There were 56 late deaths (27 patients died at reoperation). The actuarial survival rate (including hospital mortality) at 14 years was 57.2% +/- 5.4% for the entire series, with no statistically significant difference between groups. The probability of remaining free from valve-related morbidity and mortality at 14 years was 16.7% +/- 4.8% for the mitral group, 20.8% +/- 6.2% for the aortic group, and 14.0% +/- 7.0% for the mitral-aortic group. The long-term results of this series show that the clinical performance of the Hancock I porcine valve appears satisfactory during the first 6 years. The behavior of this bioprosthesis at 14 years' follow-up changes drastically, because only a minor group of patients is free from valve-related complications, justifying the restriction of its use for selected patients.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas/efeitos adversos , Adulto , Endocardite/epidemiologia , Endocardite/etiologia , Falha de Equipamento , Feminino , Seguimentos , Próteses Valvulares Cardíacas/mortalidade , Humanos , Masculino , Pessoa de Meia-Idade , Taxa de Sobrevida , Tromboembolia/epidemiologia , Tromboembolia/etiologia
17.
J Thorac Cardiovasc Surg ; 104(5): 1274-9, 1992 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-1434705

RESUMO

Satisfactory long-term clinical results with heart valves have renewed the interest in the use of mitral homografts, despite the technical difficulties with their surgical implantation. This report describes the behavior and viability of the partial mitral homograft in the ortotopic position in a chronic sheep model (n = 25). The 20 surviving animals were studied hemodynamically and were anesthetized and electively put to death 3, 6, 9, and 12 months after the operation. All specimens had a normal mitral valve without signs of infection or thrombosis. Light, scanning, and transmission electron microscopy showed the presence of viable endothelial cells from the recipient covering the graft, signs of reendothelialization, and organized dense collagen tissue. The structural integrity was more evident in the fresh mitral homografts. This method may provide consider improvement in the viability of the mitral homograft, and it could be a valid alternative for repair of mitral valve localized pathology.


Assuntos
Valva Mitral/transplante , Animais , Endotélio/citologia , Endotélio/ultraestrutura , Microscopia Eletrônica , Microscopia Eletrônica de Varredura , Valva Mitral/citologia , Valva Mitral/cirurgia , Ovinos , Transplante Homólogo/métodos
18.
J Thorac Cardiovasc Surg ; 79(3): 326-37, 1980 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-7354633

RESUMO

From May, 1974, through December, 1978, 255 mitral annuloplasties have been performed at our institution. Forty-three Carpentier rings and 212 flexible rings were used. Simultaneously, 307 patients with predominant insufficiency were treated with a Hancock bioprosthesis. A critical analysis of the flexible ring group versus the Hancock group is presented: The average ages were 41.3 versus 43.3 years. Preoperatively, 55% versus 60% were in Functional Class III and 9.6 versus 25.4% were in Class IV. The valve lesion was caused by rheumatic disease in 91.2% versus 93.9%. A multiple valve operation was required by 51% versus 60%. There was a significant difference in the operative mortality rates (1.8% versus 11.4%). This difference was maintained for each preoperative functional class and for the isolated and multiple valve groups. There was no significant difference in the late mortality rates (1.4% versus 3.7%). The total actuarial survival rates were of 96.4% and 81% (maximum follow-up times 4.0 and 4.5 years). The incidence of embolism was 2.4% and 4.1% per patient-year, with both groups being subjected to the same anticoagulation policy. The incidence of dysfunctions was equal (3.9% per patient-year). Postoperative hemodynamic evaluation of 72 patients having annuloplasty and 129 patients having Hancock valve replacement showed basal mean transmitral gradients of 10.98 +/- 3.6 and 9.66 +/- 2.73 mm Hg. The average effective orifice areas were 1.93 +/- 0.74 and 2.25 +/- 0.46 cm2. While the bioprosthesis behaves hemodynamically like a flow-related variable orifice, the reconstructed valve orifice is dependent upon its preoperative anatomy. In conclusion, the comparison of flexible ring annuloplasty and Hancock valve replacement for mitral valve disease shows a lower operative mortality for the former and comparable medium-term postoperative course. Since both techniques have a limited durability, longer follow-up periods will soon resolve this controversial issue.


Assuntos
Hemodinâmica , Insuficiência da Valva Mitral/cirurgia , Complicações Pós-Operatórias/fisiopatologia , Adolescente , Adulto , Idoso , Bioprótese , Criança , Embolia/mortalidade , Feminino , Próteses Valvulares Cardíacas , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/fisiopatologia , Insuficiência da Valva Mitral/fisiopatologia , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/cirurgia
19.
J Thorac Cardiovasc Surg ; 115(5): 1130-5, 1998 May.
Artigo em Inglês | MEDLINE | ID: mdl-9605083

RESUMO

OBJECTIVE: To investigate the long-term performance of aortic valve repair, we analyzed the results obtained in a 22-year period in patients who underwent repair of nonsevere rheumatic aortic valve disease during other valvular procedures. METHODS: Fifty-three patients (mean 40 +/- 11.6 years of age) with predominant rheumatic mitral valve disease had concomitant aortic valve disease in association with serious tricuspid valve disease in 25 of them. Preoperatively, aortic valve disease was considered moderate in 47.2% of the patients and mild in 52.8%. All patients underwent reparative techniques of the aortic valve (free edge unrolling, 44; subcommissural annuloplasty, 40; commissurotomy, 36) at the time of mitral or mitrotricuspid valve surgery. The completeness of follow-up during the closing interval was 100%, with a mean follow-up of 18.8 years (range 8 to 22.5 years). RESULTS: Hospital mortality rate was 7.5%. Of 49 surviving patients, 26 (53.1%) died during late follow-up. The actuarial survival curve including hospital mortality was 35.4% +/- 8.7% at 22 years. For patients who underwent mitral and aortic valve surgery, the actuarial survival curve at 22 years was 32.3% +/- 13%, whereas for patients who had a triple-valve operation the survival was 37.0% +/- 10.1% (p = 0.07). Twenty-five patients underwent an aortic prosthetic valve replacement. Actuarial free from aortic structural deterioration and valve-related complications at 22 years was 25.3% +/- 9.3% and 12.7% +/- 4.8%, respectively. CONCLUSIONS: Long-term functional results of reparative procedures of nonsevere aortic valve disease in patients with predominant rheumatic mitral valve disease have been inadequate at 22 years of follow-up. According to these data, conservative operations for rheumatic aortic valve disease do not seem appropriate.


Assuntos
Insuficiência da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/cirurgia , Valva Aórtica/cirurgia , Implante de Prótese de Valva Cardíaca , Cardiopatia Reumática/cirurgia , Adolescente , Adulto , Idoso , Valva Aórtica/diagnóstico por imagem , Insuficiência da Valva Aórtica/mortalidade , Insuficiência da Valva Aórtica/fisiopatologia , Estenose da Valva Aórtica/mortalidade , Estenose da Valva Aórtica/fisiopatologia , Cateterismo Cardíaco , Ponte Cardiopulmonar , Ecocardiografia Doppler , Feminino , Seguimentos , Próteses Valvulares Cardíacas , Implante de Prótese de Valva Cardíaca/mortalidade , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade , Valva Mitral/diagnóstico por imagem , Valva Mitral/cirurgia , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/fisiopatologia , Complicações Pós-Operatórias/cirurgia , Reoperação , Estudos Retrospectivos , Cardiopatia Reumática/mortalidade , Cardiopatia Reumática/fisiopatologia , Segurança , Taxa de Sobrevida , Valva Tricúspide/diagnóstico por imagem , Valva Tricúspide/cirurgia
20.
J Thorac Cardiovasc Surg ; 88(2): 234-7, 1984 Aug.
Artigo em Inglês | MEDLINE | ID: mdl-6748717

RESUMO

Valve replacement in patients with a small aortic anulus can cause difficult technical problems or leave the patient with a significant residual transvalvular gradient. Between August, 1977, and June, 1983, 35 patients with a small aortic root (21 mm or less) underwent aortic valve replacement with Ionescu-Shiley pericardial xenograft valves. They ranged in age from 29 to 76 years (mean 52.8 years) and in weight from 64 to 91 kg (mean 76.3 +/- 3.6 kg). Preoperatively, 26 patients were in New York Heart Association Functional Class III-IV. The valve sizes used were 17 mm in three cases, 19 mm in 16 cases, and 21 mm in 16 cases. There were four hospital deaths (11.4%) resulting from sepsis or low cardiac output. There were no late deaths. Cumulative duration of follow-up was 819.4 patient-months. Twenty-four (78%) of the 31 surviving patients are asymptomatic. Up to the time of review, there have been no episodes of thromboembolism, infective endocarditis, perivalvular leak, valve thrombosis, or primary tissue valve failure. Fifteen patients were hemodynamically evaluated 2 to 47 months (mean 14.3 months) after operation. The average resting transvalvular gradients for 19 and 21 mm valves were 15.1 and 10.8 mm Hg, respectively. Our experience suggests that the Ionescu-Shiley pericardial xenograft valve is a valid alternative in the surgical treatment of patients with a small aortic root.


Assuntos
Bioprótese , Próteses Valvulares Cardíacas , Adulto , Idoso , Valva Aórtica/patologia , Valva Aórtica/cirurgia , Feminino , Seguimentos , Hemodinâmica , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA