Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
J Interv Cardiol ; 29(2): 208-15, 2016 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-26927945

RESUMO

OBJECTIVES: To evaluate the mid-term outcomes after percutaneous closure of the secundum atrial septal defects (ASD) using the Figulla-Occlutech device (FOD). BACKGROUND: Transcatheter closure has become the method of choice for most patients with ASD. Although the FOD may have some advantageous characteristics there is a paucity of data on later outcomes after the use of this relatively new device. METHODS: Observational, single arm study including 200 non-consecutive patients who underwent ASD closure between 04/09 and 07/15 in 2 centers. Device performance, deployment technique, and immediate and mid-term outcomes were assessed. RESULTS: Median age and weight were 24 years (4-72) and 58 kg (15-92), respectively. Single defects were observed in 171 patients (median size of 19 mm). The remainder had multiple or multifenestrated defects. Implantation of FOD (median size of 24 mm) was successful in all (99%), but 2 patients (1 with deficient postero-inferior rim; 1 with a large ASD for the size of the child). Embolization with device retrieval occurred in 2 (1%). Median follow-up of 36 months was obtained in 172 patients. Serial echocardiographic assessment showed complete closure in all but 2 patients, in whom an additional small non-significant posterior defect was purposely left untouched. There have been no episodes of late arrhythmias, device embolization, cardiac erosion, endocarditis, thromboembolism, wire fracture, or death. CONCLUSIONS: Transcatheter closure of ASDs in older children, adolescents, and adults using the FOD was highly successful in a wide range of anatomical scenarios with high closure rates and no complications in mid-term follow-up.


Assuntos
Cateterismo Cardíaco/métodos , Comunicação Interatrial/cirurgia , Dispositivo para Oclusão Septal/efeitos adversos , Adolescente , Adulto , Idoso , Cateterismo Cardíaco/efeitos adversos , Cateterismo Cardíaco/instrumentação , Criança , Pré-Escolar , Ecocardiografia/métodos , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Estudos Retrospectivos , Resultado do Tratamento , Adulto Jovem
2.
Sci Rep ; 3: 3054, 2013 Oct 29.
Artigo em Inglês | MEDLINE | ID: mdl-24165828

RESUMO

We present an approach to control the magnetic structure of adatoms adsorbed on a substrate having a high magnetic susceptibility. Using finite Ni-Pt and Fe-Pt nanowires and nanostructures on Pt(111) surfaces, our ab initio results show that it is possible to tune the exchange interaction and magnetic configuration of magnetic adatoms (Fe or Ni) by introducing different numbers of Pt atoms to link them, or by including edge effects. The exchange interaction between Ni (or Fe) adatoms on Pt(111) can be considerably increased by introducing Pt chains to link them. The magnetic ordering can be regulated allowing for ferromagnetic or antiferromagnetic configurations. Noncollinear magnetic alignments can also be stabilized by changing the number of Pt-mediated atoms. An Fe-Pt triangularly-shaped nanostructure adsorbed on Pt(111) shows the most complex magnetic structure of the systems considered here: a spin-spiral type of magnetic order that changes its propagation direction at the triangle vertices.

3.
Rev. Soc. Cardiol. Estado de Säo Paulo ; 27(1): 39-48, jan.-mar. 2017. ilus
Artigo em Português | LILACS, SES-SP, SES SP - Instituto Dante Pazzanese de Cardiologia, SES-SP | ID: biblio-836944

RESUMO

A comunicação interatrial tipo ostium secundum (CIA OS) é uma cardiopatia congênita relativamente frequente, que causa repercussão hemodinâmica para o ventrículo direito, com sobrecarga volumétrica e dilatação da câmara. A maioria dos pacientes é assintomática, porém sintomas podem aparecer depois da segunda década de vida. O tratamento eletivo é usualmente realizado próximo ao quinto ano de vida, podendo ser indicado mais precocemente quando houver sintomatologia exuberante. O fechamento transcateter usando uma prótese de duplo disco é bem estabelecido como a primeira escolha de tratamento para a maioria dos pacientes de anatomia favorável. Foi comprovado que o forame oval patente (FOP) está associado à acidente vascular cerebral isquêmico (AVCI) em pacientes com poucos ou nenhum fator de risco de doença cardiovascular. Recentemente, foi demonstrado que a oclusão transcateter do FOP é superior ao tratamento clínico para prevenir recorrências de AVCI nessa população, em um estudo randomizado com acompanhamento clínico de longo prazo. Este manuscrito revisa as atuais indicações, critérios de seleção do paciente e o seguimento clínico dos pacientes com CIA OS e FOP submetidos ao tratamento transcateter


Ostium secundum atrial septal defect (OS-ASD) is a relatively frequent congenital heart defect that causes hemodynamic burden on the right ventricle with volume overload and chamber dilatation. Most patients are asymptomatic, however symptoms can appear after the second decade of life. Elective treatment is usually performed around the fifth year of life, and may be occasionally indicated earlier if there are exuberant symptoms. Transcatheter closure using a double disc device is well established as the first choice of treatment for most patients with suitable anatomy. Patent foramen ovale (PFO) has been shown to be associated with ischemic stroke in patients with no or limited risk factors for cardiovascular disease. It was recently demonstrated in a randomized trial with long-term follow-up that transcatheter closure of PFO is superior to medical treatment for preventing recurrences of stroke in this patient population. This manuscript reviews the current indications, patient selection criteria, and long-term follow-up in patients with OS-ASD and PFO submitted to transcatheter closure


Assuntos
Humanos , Masculino , Feminino , Criança , Forame Oval Patente/terapia , Átrios do Coração/cirurgia , Cardiopatias Congênitas/fisiopatologia , Comunicação Interatrial/terapia , Ventrículos do Coração , Cirurgia Torácica , Ecocardiografia/métodos , Cateterismo Cardíaco/métodos , Heparina/administração & dosagem , Aspirina/administração & dosagem , Fatores de Risco , Resultado do Tratamento , Artéria Femoral , Cateteres Cardíacos , Coração/fisiopatologia
4.
Rev. bras. cardiol. invasiva ; 19(4): 430-441, dez. 2011. ilus
Artigo em Português | LILACS, SES-SP | ID: lil-618804

RESUMO

INTRODUÇÃO: Uma nova geração de próteses Amplatzer com menor perfil e maior flexibilidade foi desenvolvida recentemente para o tratamento percutâneo da persistência do canal arterial (PCA). Neste artigo é relatado o uso desse novo dispositivo, Amplatzer Duct Occludder IITM (ADO II), para o tratamento tanto de PCA como de outros defeitos congênitos e estruturais, avaliando sua eficácia e segurança. Métodos: Estudo longitudinal observacional de um coorte de pacientes portadores de cardiopatias congênitas e estruturais tratados com ADO II entre outubro de 2009 e agosto de 2011. Pacientes com menos de 5 kg e canais > 5,5 mm e/ou do tipo B foram excluídos do estudo. A prótese foi implantada por vias anterógrada ou retrógrada. A cintura foi cerca de 2 mm maior que o defeito e o comprimento da prótese foi de 4 mm para lesões mais curtas ( até 6-8 mm). Resultados: Foram incluídos no estudo 28 pacientes, com mediana de idade e de peso de 2 anos e 11,7 kg, respectivamente, dos quais 23 eram portadores de PCA com diâmetro mínimo de 2,3 +- 0,8 mm. Os demais apresentavam...


BACKGROUND: A new generation of Amplatzer devices with lower profile and greater flexibility has been recently developed for percutaneous occlusion of the patent ductus arteriosus (PDA). In this paper, the use of this new device, the Amplatzer Duct Occludder II TM (ADO II) for percutaneous closure of the PDA as well as for the treatment of other congenital and structural heart defects is reported, assessing its safety and efficacy. METHODS: Longitudinal and observational study of a cohort of patients with congenital and structural heart defects treated with ADO II between October 2009 and August 2011. Patients weighing less than 5 kg and PDAs > 5.5 mm and/or type B were excluded. The device was implanted using the antegrade or retrograde approach. The waist was 2 mm larger than the defect and the length of the prosthesis was 4 mm for shorter lesions (less than 6-8 mm). RESULTS: Twenty-eight patients with a median age and weight of 2 years and 11.7 kg, respectively, were included. Twenty-three had a PDA with a mean minimal diameter of 2.3 + 0.8 mm. The remainder had muscular ventricular septal defect (1), pulmonary arteriovenous fistula (1), ruptured aneurysm of the sinus of Valsalva (1), and univentricular heart in the early postoperative period of bidirectional cavopulmonary anastomosis with residual antegrade pulmonary flow (2). The device was successfully implanted in all patients, except for an infant weighing 8 kg with a long, tortuous and oblique PDA with a diameter of 2.8 mm and a shallow ampulla. There was total occlusion of the defects in all patients. One patient with univentricular heart and right isomerism died due to complications not related to the procedure. CONCLUSIONS: ADO II proved to be a flexible, safe and effective device for the percutaneous treatment of infants, children and selected adults with PDA and other congenital and structural heart defects. Its use may have limitations for some anatomical PDA configurations in smaller infants.


Assuntos
Humanos , Masculino , Feminino , Pré-Escolar , Próteses e Implantes , Canal Arterial/anormalidades , Cardiopatias Congênitas/cirurgia , Cardiopatias Congênitas/complicações , Cateterismo Cardíaco/métodos , Cateterismo Cardíaco , Angiografia/métodos , Angiografia , Ecocardiografia/métodos , Ecocardiografia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA