Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Eur J Vasc Endovasc Surg ; 61(4): 628-634, 2021 04.
Artigo em Inglês | MEDLINE | ID: mdl-33583710

RESUMO

OBJECTIVE: The coronavirus disease of 2019 (COVID-19) due to SARS-CoV-2 infection has been found to cause an increased risk of venous thrombo-embolism (VTE). The aims of the study were to determine the frequency of VTE in critically ill patients with COVID-19 and its correlation with D dimer levels and pharmacological prophylaxis. METHODS: This was a cohort study of critically ill patients due to COVID-19. All patients admitted to the intensive care unit on the same day of April 2020 were selected, regardless of length of stay, and a single bilateral venous duplex ultrasound in the lower extremities was performed up to 72 hours later. Pulmonary embolism (PE) was diagnosed by computed tomography angiography. Asymptomatic and symptomatic VTE were registered, including pre-screening in hospital VTE. Characteristics of patients, blood test results, doses of thromboprophylaxis received, VTE events, and mortality after seven day follow up were recorded. RESULTS: A total of 230 critically ill patients were studied. The median intensive care unit stay of these patients was 12 days (interquartile range [IQR] 5 - 19 days). After seven days follow up, the frequency of patients with VTE, both symptomatic and asymptomatic, was 26.5% (95% confidence interval [CI] 21% - 32%) (69 events in 61 patients): 45 with DVT and 16 with PE (eight of them with concomitant DVT). The cumulative frequency of symptomatic VTE was 8.3% (95% CI 4.7% - 11.8%). D dimer values ≥ 1 500 ng/mL were diagnostic of VTE, with a sensitivity of 80% and a specificity of 42%. During follow up after screening, six patients developed new VTE. Three of them developed a recurrence after a DVT diagnosed at screening, despite receiving therapeutic doses of heparin. Mortality rates at seven day follow up were the same for those with (6.6%) and without (5.3%) VTE. CONCLUSION: Patients with severe COVID-19 infection are at high risk of VTE, and further new symptomatic VTE events and recurrence can occur despite anticoagulation. The prophylactic anticoagulant dose may need to be increased in patients with a low risk of bleeding.


Assuntos
COVID-19/complicações , Tromboembolia Venosa/epidemiologia , Tromboembolia Venosa/etiologia , Idoso , COVID-19/sangue , Estudos de Coortes , Correlação de Dados , Estado Terminal , Feminino , Produtos de Degradação da Fibrina e do Fibrinogênio/análise , Humanos , Masculino , Pessoa de Meia-Idade , Medição de Risco , Tromboembolia Venosa/sangue , Tromboembolia Venosa/prevenção & controle
2.
Ann Vasc Surg ; 69: 366-372, 2020 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-32504790

RESUMO

BACKGROUND: To compare contrast usage and radiation exposure during endovascular aneurysm repair (EVAR) using mobile C-arm imaging in a conventional operating room (OR) or fixed angiographic equipment in a hybrid OR (HR). METHODS: A retrospective unicenter study from May 2016 to August 2019. All consecutive patients undergoing standard EVAR were included. Patients were divided into 2 groups. Group OR included EVARs performed in a conventional OR with a mobile C-arm (May 2016 to April 2018) and group HR included EVARs performed with a fixed angiographic equipment in an HR (May 2018 to August 2019). Data collected included patient demographics, aneurysm diameter, neck length, radiation dose: median dose-area product (DAP), fluoroscopy time, total operative time, contrast use, and 30-day clinical outcomes. RESULTS: A total of 77 patients were included in the study (42 patients in group OR and 35 patients in group HR). There was no difference in age, body mass index (BMI), mean aneurysm, and neck length between groups. Patients in the group HR received less contrast volume (108.6 mL [±41.5] vs. 162.5 mL [±52.6]; P < 0.001), but higher radiation dose (154 Gy cm2 [±102.9] vs. 61.5 Gy cm2 [±42.4]; P < 0.001). There were no differences in fluoroscopy time (20.4 min [±8.5] vs. 23.2 min [±12.4]; P = 0.274) and total operative time (106.4 [±22.3] vs. 109.4 [±25.8]; P = 0.798). No difference was found in terms of 30-day complication rates or operative mortality between groups. DAP was positively correlated with BMI in the group OR (Spearman's rank correlation coefficient rs, 0.580; P < 0.001), but no correlation could be seen in the group HR (rs, 0.408; P = 0.028). CONCLUSIONS: Routine EVAR performed in a hybrid fixed-imaging suite may be associated with less contrast usage, but higher radiation exposure in our center. The significantly higher radiation exposure when the mobile C-arm is replaced by an HR should not be underestimated.


Assuntos
Aneurisma da Aorta Abdominal/cirurgia , Implante de Prótese Vascular/instrumentação , Procedimentos Endovasculares/instrumentação , Arquitetura de Instituições de Saúde , Salas Cirúrgicas/organização & administração , Radiografia Intervencionista/instrumentação , Idoso , Idoso de 80 Anos ou mais , Aneurisma da Aorta Abdominal/diagnóstico por imagem , Implante de Prótese Vascular/efeitos adversos , Meios de Contraste/administração & dosagem , Meios de Contraste/efeitos adversos , Bases de Dados Factuais , Procedimentos Endovasculares/efeitos adversos , Desenho de Equipamento , Feminino , Humanos , Masculino , Duração da Cirurgia , Doses de Radiação , Exposição à Radiação/efeitos adversos , Radiografia Intervencionista/efeitos adversos , Estudos Retrospectivos , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
3.
J Sports Sci ; 33(16): 1702-9, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-25620031

RESUMO

The purpose of this study was to assess the validity of accelerometers using force plates (i.e., ground reaction force (GRF)) during the performance of different tasks of daily physical activity in children. Thirteen children (10.1 (range 5.4-15.7) years, 3 girls) wore two accelerometers (ActiGraph GT3X+ (ACT), GENEA (GEN)) at the hip that provide raw acceleration signals at 100 Hz. Participants completed different tasks (walking, jogging, running, landings from boxes of different height, rope skipping, dancing) on a force plate. GRF was collected for one step per trial (10 trials) for ambulatory movements and for all landings (10 trials), rope skips and dance procedures. Accelerometer outputs as peak loading (g) per activity were averaged. ANOVA, correlation analyses and Bland-Altman plots were computed to determine validity of accelerometers using GRF. There was a main effect of task with increasing acceleration values in tasks with increasing locomotion speed and landing height (P < 0.001). Data from ACT and GEN correlated with GRF (r = 0.90 and 0.89, respectively) and between each other (r = 0.98), but both accelerometers consistently overestimated GRF. The new generation of accelerometer models that allow raw signal detection are reasonably accurate to measure impact loading of bone in children, although they systematically overestimate GRF.


Assuntos
Acelerometria/normas , Atividade Motora , Aceleração , Atividades Cotidianas , Adolescente , Osso e Ossos/fisiologia , Criança , Pré-Escolar , Feminino , Humanos , Masculino
4.
J Foot Ankle Res ; 16(1): 84, 2023 Nov 25.
Artigo em Inglês | MEDLINE | ID: mdl-38001471

RESUMO

BACKGROUND: This report aims to present a novel system for the management of foot lesions in patients with diabetes. It was developed in the diabetic foot unit (DFU) of the Mutua de Terrassa University Hospital (HUMT) by primary care professionals, the Diabetic Foot Clinic (DFC), and during emergency cases treated by our group based on daily activities in patients with neuropathy or neuroischemia. BODY: This system considers five degrees of action based on two fixed variables: presence of infection and lesion depth. These two variables allowed the user to investigate aspects of the system until the overall action required by the pathology is made clear. These variables establish pathology stages of various severities that require different actions in aspects of care, management and treatment. CONCLUSION: This tool facilitates diagnosis, treatment, and coordination among different members of a multidisciplinary team working in specialized hospital units, primary care centers, and emergency settings.


Assuntos
Diabetes Mellitus , Pé Diabético , Humanos , Pé Diabético/diagnóstico , Pé Diabético/terapia
5.
Cells ; 12(8)2023 04 07.
Artigo em Inglês | MEDLINE | ID: mdl-37190017

RESUMO

Two α-isoforms of the Na+,K+-ATPase (α1 and α2) are expressed in the cardiovascular system, and it is unclear which isoform is the preferential regulator of contractility. Mice heterozygous for the familial hemiplegic migraine type 2 (FHM2) associated mutation in the α2-isoform (G301R; α2+/G301R mice) have decreased expression of cardiac α2-isoform but elevated expression of the α1-isoform. We aimed to investigate the contribution of the α2-isoform function to the cardiac phenotype of α2+/G301R hearts. We hypothesized that α2+/G301R hearts exhibit greater contractility due to reduced expression of cardiac α2-isoform. Variables for contractility and relaxation of isolated hearts were assessed in the Langendorff system without and in the presence of ouabain (1 µM). Atrial pacing was performed to investigate rate-dependent changes. The α2+/G301R hearts displayed greater contractility than WT hearts during sinus rhythm, which was rate-dependent. The inotropic effect of ouabain was more augmented in α2+/G301R hearts than in WT hearts during sinus rhythm and atrial pacing. In conclusion, cardiac contractility was greater in α2+/G301R hearts than in WT hearts under resting conditions. The inotropic effect of ouabain was rate-independent and enhanced in α2+/G301R hearts, which was associated with increased systolic work.


Assuntos
Fibrilação Atrial , Transtornos de Enxaqueca , Camundongos , Animais , ATPase Trocadora de Sódio-Potássio/genética , ATPase Trocadora de Sódio-Potássio/metabolismo , Ouabaína/farmacologia , Isoformas de Proteínas/metabolismo , Mutação/genética , Fenótipo
6.
Int Angiol ; 41(1): 1-8, 2022 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34751541

RESUMO

BACKGROUND: Venous thromboembolism (VTE) disease in COVID-19 patients is a remarkable issue, especially its relationship with bleeding events and mortality. The objective of this study was to describe the outcomes of critically ill patients with COVID-19, hospitalized in the Intensive Care Unit (ICU), in relationship with VTE during their stay. METHODS: This is a prospective cohort study of critically ill COVID-19 patients in two hospitals that underwent a venous ultrasound at the beginning of follow-up of both lower limbs in April 2020. In case of clinical suspicion of new VTE during the 30-day follow-up, additional ultrasound or thoracic CT were performed. Global VTE frequency, major bleeding events and survival were collected, and their predictors were studied. RESULTS: We included 230 patients. After 30 days of follow-up, there were 95 VTE events in 86 patients (37.4%). Thirteen patients (5.7%) developed major bleeding complications and 42 patients (18.3%) died. None of the comorbidities or previous treatments were related with bleeding events. D-Dimer at admission was significantly related with VTE development and mortality. Independent predictors of mortality in the regression model were older age (>66 years), D-Dimer at admission (>1.500 ng/mL) and low lymphocyte count (<0.45×109/L) with an AUC in the ROC curve of 0.81 (95% CI: 0.73-0.89). Patients presenting these three conditions presented a mortality of 100% in the predictive model. CONCLUSIONS: VTE frequency in ICU COVID-19 patients is high and risk of major bleeding is low. Comorbidities and laboratory parameters of admission in these patients can be a useful tool to predict mortality.


Assuntos
COVID-19 , Tromboembolia Venosa , Estado Terminal , Humanos , Estudos Prospectivos , Estudos Retrospectivos , Fatores de Risco , SARS-CoV-2 , Tromboembolia Venosa/etiologia
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA