Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 32
Filtrar
Mais filtros

Base de dados
Tipo de documento
País de afiliação
Intervalo de ano de publicação
1.
Clin Proteomics ; 21(1): 5, 2024 Jan 24.
Artigo em Inglês | MEDLINE | ID: mdl-38267848

RESUMO

BACKGROUND: The 2022 consensus statement of the European Atherosclerosis Society (EAS) on lipoprotein(a) (Lp(a)) recognizes the role of Lp(a) as a relevant genetically determined risk factor and recommends its measurement at least once in an individual's lifetime. It also strongly urges that Lp(a) test results are expressed as apolipoprotein (a) (apo(a)) amount of substance in molar units and no longer in confounded Lp(a) mass units (mg/dL or mg/L). Therefore, IVD manufacturers should transition to molar units. A prerequisite for this transition is the availability of an Lp(a) Reference Measurement Procedure (RMP) that allows unequivocal molecular detection and quantification of apo(a) in Lp(a). To that end an ISO 17511:2020 compliant LC-MS based and IFCC-endorsed RMP has been established that targets proteotypic peptides of apolipoprotein(a) (apo(a)) in Lp(a). The RMP is laborious and requires highly skilled operators. To guide IVD-manufacturers of immunoassay-based Lp(a) test kits in the transition from mass to molar units, a Designated Comparison Method (DCM) has been developed and evaluated. METHODS: To assess whether the DCM provides equivalent results compared to the RMP, the procedural designs were compared and the analytical performance of DCM and RMP were first evaluated in a head-to-head comparison. Subsequently, apo(a) was quantified in 153 human clinical serum samples. Both DCM and RMP were calibrated using external native calibrators that produce results traceable to SRM2B. Measurement uncertainty (MU) was checked against predefined allowable MU. RESULTS: The major difference in the design of the DCM for apo(a) is the use of only one enzymatic digestion step. The analytical performance of the DCM and RMP for apo(a) is highly similar. In a direct method comparison, equivalent results were obtained with a median regression slope 0.997 of and a median bias of - 0.2 nmol/L (- 0.2%); the intermediate imprecision of the test results was within total allowable error (TEa) (CVa of 10.2% at 90 nmol/L). CONCLUSIONS: The semi-automated, higher throughput, LC-MS-based method for Lp(a) meets the predefined analytical performance specifications and allowable MU and is hence applicable as a higher order Designated Comparison Method, which is ideally suited to guide IVD manufacturers in the transition from Lp(a) mass to molar units.

2.
Clin Chem Lab Med ; 2024 Oct 31.
Artigo em Inglês | MEDLINE | ID: mdl-39479776

RESUMO

OBJECTIVES: As high-sensitivity cardiac troponin T (hs-cTnT) is making the transition from diagnostic to prognostic use, a long-term stability study of 5th generation hs-cTnT according to EFLM CRESS recommendations was set up for investigation of frozen clinical specimens (two matrices). METHODS: Study samples collected in serum tubes and lithium heparin tubes with gel from patients admitted for suspected minor myocardial damage were measured directly after completion of the study (0 years), and after 3-year and 6-year storage at -80 °C, and recovery of hs-cTnT concentrations after long-term storage (%hs-cTnT concentration compared to 0-year) was calculated. Hs-cTnT changes were also compared to decisive delta changes, such as the ones proposed in the ESC NSTEMI 0 h/1 h algorithm (<3 or >5 ng/L for ruling out and ruling in suspected NSTEMI patients). RESULTS: Eighty-six patients were included in the study, whereof 28 both lithium heparin plasma and serum samples were collected simultaneously, in others only serum (n=30) or plasma (n=28). Multiple aliquots per patient were made, so that 479 serum and 473 plasma samples were available for analysis. Across the overall hs-cTnT measuring range, median recovery after 6 years was 105.4 % and 106.2 % for serum and plasma, respectively. Based on these decisive delta changes, serum showed consistent results upon long term storage (max 0.8 % of samples above delta threshold of >5 ng/L) as compared to heparin plasma (up to 19.2 % of samples above threshold). CONCLUSIONS: Over 6 years of storage at -80 °C, recovery of hs-cTnT in serum and heparin plasma was similar and within common lot-to-lot variation. Yet, when evaluating absolute delta increments around hs-cTnT clinical decision points, long-term stored sera displayed better clinical performance compared to heparin plasma samples.

3.
Clin Chem Lab Med ; 2024 Oct 28.
Artigo em Inglês | MEDLINE | ID: mdl-39450666

RESUMO

OBJECTIVES: Quantitative protein mass spectrometry (MS) is ideally suited for precision diagnostics and for reference standardization of protein analytes. At the Leiden Apolipoprotein Reference Laboratory we apply MS strategies to obtain detailed insight into the protein-to-peptide conversion in order to verify that quantifier peptides are not partly concealed in miscleaved protein backbone. METHODS: Apolipoprotein(a) (apo(a)) was digested in a non-optimal manner to enhance the number of miscleaved peptides that were identified by high resolution liquid chromatography tandem-MS measurements. The protein-to-peptide conversion was carefully mapped with specific attention for miscleaved peptides that contain an apo(a) quantifier peptide. Four different isotopologues of each apo(a)-quantifier peptide were applied to evaluate linearity of internal peptide standards during measurement of specific real-life samples. RESULTS: Two apo(a) quantifier peptides that were concealed in two different miscleaved peptides were included into a multiple reaction monitoring list in our targeted MS-based apo(a) quantifications to alert for potential protein digestion discrepancies. The presence of miscleaved peptides could be ruled out when applying our candidate reference measurement procedure (RMP) for apo(a) quantification. CONCLUSIONS: These data further corroborate the validity of our apo(a) candidate RMP as higher order method for certification of commercial Lp(a) tests that is endorsed by the International Federation of Clinical Chemistry and Laboratory Medicine. MS-based molecular detection and quantification of heterogeneous apo(a) proteoforms will allow manufacturers' transitioning from confounded lipoprotein(a) [Lp(a)] mass levels into accurate molar apo(a) levels.

4.
Clin Chem ; 69(3): 251-261, 2023 03 01.
Artigo em Inglês | MEDLINE | ID: mdl-36644914

RESUMO

BACKGROUND: Medical results generated by European CE Marking for In Vitro Diagnostic or in-house tests should be traceable to higher order reference measurement systems (RMS), such as International Federation of Clinical Chemistry and Laboratory Medicine (IFCC)-endorsed reference measurement procedures (RMPs) and reference materials. Currently, serum apolipoprotein (a) [apo(a)] is recognized as a novel risk factor for cardiovascular risk assessment and patient management. The former RMS for serum apo(a) is no longer available; consequently, an International System of Units (SI)-traceable, ideally multiplexed, and sustainable RMS for apo(a) is needed. METHODS: A mass spectrometry (MS)-based candidate RMP (cRMP) for apo(a) was developed using quantitative bottom-up proteomics targeting 3 proteotypic peptides. The method was provisionally validated according to ISO 15193 using a single human serum based calibrator traceable to the former WHO-IFCC RMS. RESULTS: The quantitation of serum apo(a) was by design independent of its size polymorphism, was linear from 3.8 to 456 nmol/L, and had a lower limit of quantitation for apo(a) of 3.8 nmol/L using peptide LFLEPTQADIALLK. Interpeptide agreement showed Pearson Rs of 0.987 and 0.984 for peptides GISSTVTGR and TPENYPNAGLTR, and method comparison indicated good correspondence (slopes 0.977, 1.033, and 1.085 for LFLEPTQADIALLK, GISSTVTGR, and TPENYPNAGLTR). Average within-laboratory imprecision of the cRMP was 8.9%, 11.9%, and 12.8% for the 3 peptides. CONCLUSIONS: A robust, antibody-independent, MS-based cRMP was developed as higher order RMP and an essential part of the apo(a) traceability chain and future RMS. The cRMP fulfils predefined analytical performance specifications, making it a promising RMP candidate in an SI-traceable MS-based RMS for apo(a).


Assuntos
Peptídeos , Soro , Humanos , Apoproteína(a) , Espectrometria de Massas , Padrões de Referência , Calibragem
5.
Clin Chem ; 69(8): 924-935, 2023 08 02.
Artigo em Inglês | MEDLINE | ID: mdl-37477911

RESUMO

BACKGROUND: We explored the potential of emerging and conventional urinary kidney injury biomarkers in recipients of living donor (LD) or donation after circulatory death (DCD) kidney transplantation, patients with chronic kidney disease (CKD), and individuals from the general population. METHODS: Urine samples from kidney allograft recipients with mild (LD; n = 199) or severe (DCD; n = 71) ischemia-reperfusion injury (IRI) were analyzed for neutrophil gelatinase-associated lipocalin (NGAL), insulin-like growth factor-binding protein 7 (IGFBP7), tissue inhibitor of metalloproteinases 2 (TIMP2), kidney injury molecule-1 (KIM-1), chemokine C-X-C motif (CXCL9), solute carrier family 22 member 2 (SLC22A2), nephrin, and uromodulin (UMOD) by quantitative multiplex LC-MS/MS analysis. The fold-change in biomarker levels was determined in mild and severe IRI and in patients with CKD stage 1-2 (n = 127) or stage ≥3 (n = 132) in comparison to the general population (n = 1438). Relationships between the biomarkers and total protein, ß2-microglobulin (B2M), creatinine, and osmolality were assessed. RESULTS: NGAL, IGFBP7, TIMP2, KIM-1, CXCL9, and UMOD were quantifiable, whereas nephrin and SLC22A2 were below the limit of detection. Kidney injury biomarkers were increased up to 6.2-fold in allograft recipients with mild IRI and 8.3-fold in recipients with severe IRI, compared to the reference population, with the strongest response observed for NGAL and B2M. In CKD stage 1-2, B2M, NGAL, IGFBP7, TIMP2, KIM-1, UMOD, and CXCL9 were not altered, but in individuals with CKD stage ≥3, B2M, NGAL, and KIM-1 were increased up to 1.3-fold. IGFBP7, TIMP2, NGAL, and CXCL9 were strongly correlated (all r ≥ 0.8); correlations with B2M and TP were smaller (all r ≤ 0.6). CONCLUSIONS: IRI, but not stable CKD, was associated with increased urinary levels of kidney injury biomarkers determined by LC-MS/MS. Absolute and multiplexed protein quantitation by LC-MS/MS is an effective strategy for biomarker panel evaluation for translation toward the clinical laboratory.


Assuntos
Injúria Renal Aguda , Insuficiência Renal Crônica , Traumatismo por Reperfusão , Humanos , Lipocalina-2/urina , Cromatografia Líquida , Espectrometria de Massas em Tandem , Rim , Biomarcadores/urina , Aloenxertos , Injúria Renal Aguda/diagnóstico
6.
Clin Chem Lab Med ; 61(1): 55-66, 2023 01 27.
Artigo em Inglês | MEDLINE | ID: mdl-36069790

RESUMO

OBJECTIVES: Quantitative protein mass-spectrometry (QPMS) in blood depends on tryptic digestion of proteins and subsequent measurement of representing peptides. Whether serum and plasma can be used interchangeably and whether in-vitro anticoagulants affect the recovery is unknown. In our laboratory serum samples are the preferred matrix for QPMS measurement of multiple apolipoproteins. In this study, we investigated the effect of different matrices on apolipoprotein quantification by mass spectrometry. METHODS: Blood samples were collected from 44 healthy donors in Beckton Dickinson blood tubes simultaneously for serum (with/without gel) and plasma (heparin, citrate or EDTA). Nine apolipoproteins were quantified according to standard operating procedure using value-assigned native serum calibrators for quantitation. Tryptic digestion kinetics were investigated in the different matrices by following formation of peptides for each apolipoprotein in time, up to 22 h. RESULTS: In citrate plasma recovery of apolipoproteins showed an overall reduction with a bias of -14.6%. For heparin plasma only -0.3% bias was found compared to serum, whereas for EDTA-plasma reduction was more pronounced (-5.3% bias) and variable with >14% reduction for peptides of apoA-I, A-II and C-III. Digestion kinetics revealed that especially slow forming peptides showed reduced formation in EDTA-plasma. CONCLUSIONS: Plasma anticoagulants affect QPMS test results. Heparin plasma showed comparable results to serum. Reduced concentrations in citrate plasma can be explained by dilution, whereas reduced recovery in EDTA-plasma is dependent on altered proteolytic digestion efficiency. The results highlight the importance of a standardized pre-analytical phase for accurate QPMS applications in clinical chemistry.


Assuntos
Heparina , Fase Pré-Analítica , Humanos , Ácido Edético , Espectrometria de Massas , Anticoagulantes , Ácido Cítrico , Citratos
7.
Int J Mol Sci ; 23(20)2022 Oct 17.
Artigo em Inglês | MEDLINE | ID: mdl-36293255

RESUMO

The prospective, multicenter TESTBREAST study was initiated with the aim of identifying a novel panel of blood-based protein biomarkers to enable early breast cancer detection for moderate-to-high-risk women. Serum samples were collected every (half) year up until diagnosis. Protein levels were longitudinally measured to determine intrapatient and interpatient variabilities. To this end, protein cluster patterns were evaluated to form a conceptual basis for further clinical analyses. Using a mass spectrometry-based bottom-up proteomics strategy, the protein abundance of 30 samples was analyzed: five sequential serum samples from six high-risk women; three who developed a breast malignancy (cases) and three who did not (controls). Serum samples were chromatographically fractionated and an in-depth serum proteome was acquired. Cluster analyses were applied to indicate differences between and within protein levels in serum samples of individuals. Statistical analyses were performed using ANOVA to select proteins with a high level of clustering. Cluster analyses on 30 serum samples revealed unique patterns of protein clustering for each patient, indicating a greater interpatient than intrapatient variability in protein levels of the longitudinally acquired samples. Moreover, the most distinctive proteins in the cluster analysis were identified. Strong clustering patterns within longitudinal intrapatient samples have demonstrated the importance of identifying small changes in protein levels for individuals over time. This underlines the significance of longitudinal serum measurements, that patients can serve as their own controls, and the relevance of the current study set-up for early detection. The TESTBREAST study will continue its pursuit toward establishing a protein panel for early breast cancer detection.


Assuntos
Neoplasias da Mama , Humanos , Feminino , Neoplasias da Mama/patologia , Proteoma/metabolismo , Estudos Prospectivos , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Proteínas Sanguíneas/análise , Biomarcadores , Biomarcadores Tumorais
8.
J Proteome Res ; 20(12): 5304-5314, 2021 12 03.
Artigo em Inglês | MEDLINE | ID: mdl-34735145

RESUMO

Kidney injury is a complication frequently encountered in hospitalized patients. Early detection of kidney injury prior to loss of renal function is an unmet clinical need that should be targeted by a protein-based biomarker panel. In this study, we aim to quantitate urinary kidney injury biomarkers at the picomolar to nanomolar level by liquid chromatography coupled to tandem mass spectrometry in multiple reaction monitoring mode (LC-MRM-MS). Proteins were immunocaptured from urinary samples, denatured, reduced, alkylated, and digested into peptides before LC-MRM-MS analysis. Stable-isotope-labeled peptides functioned as internal standards, and biomarker concentrations were attained by an external calibration strategy. The method was evaluated for selectivity, carryover, matrix effects, linearity, and imprecision. The LC-MRM-MS method enabled the quantitation of KIM-1, NGAL, TIMP2, IGFBP7, CXCL9, nephrin, and SLC22A2 and the detection of TGF-ß1, cubilin, and uromodulin. Two to three peptides were included per protein, and three transitions were monitored per peptide for analytical selectivity. The analytical carryover was <1%, and minimal urine matrix effects were observed by combining immunocapture and targeted LC-MRM-MS analysis. The average total CV of all quantifier peptides was 26%. The linear measurement range was determined per measurand and found to be 0.05-30 nmol/L. The targeted MS-based method enables the multiplex quantitation of low-abundance urinary kidney injury biomarkers for future clinical evaluation.


Assuntos
Peptídeos , Espectrometria de Massas em Tandem , Cromatografia Líquida/métodos , Humanos , Isótopos , Rim/química , Rim/fisiologia , Peptídeos/análise , Espectrometria de Massas em Tandem/métodos
9.
Br J Cancer ; 115(3): 332-8, 2016 07 26.
Artigo em Inglês | MEDLINE | ID: mdl-27404454

RESUMO

BACKGROUND: Cancer-related venous thromboembolism (VTE) heralds a poor prognosis, especially in pancreatic adenocarcinoma (PAC). Tissue factor (TF) is implicated as one of the main culprits in PAC-associated VTE and disease progression. METHODS: In a prospective cohort study of 79 PAC patients, we measured plasma CA19-9 and microparticle-associated TF activity (MP-TF activity). In addition, we enumerated TF(+)MPs and MUC1(+)MPs in plasma (n=55), and studied the expression of TF, MUC1, CD31 and CD68 in tumour tissue (n=44). RESULTS: Plasma MP-TF activity was markedly elevated in PAC patients with VTE compared with those without (median: 1925 vs 113 fM Xa min(-1); P<0.001) and correlated with the extent of thromboembolic events, metastatic disease and short survival. Similar results were found for CA19-9. Patients with massively progressing thrombosis and cerebral embolisms despite anticoagulant therapy (n=3) had the highest MP-TF activities (12 118-40 188 fM Xa min(-1)) and CA19-9 (40 730-197 000 kU l(-1)). All tumours expressed MUC1 and TF. MP-TF activity did not correlate with intensity of TF expression in adenocarcinoma cells, but corresponded with numbers of TF(+) macrophages in the surrounding stroma. CONCLUSIONS: Circulating TF(+)MPs and mucins may concertedly aggravate coagulopathy in PAC. Understanding of underlying mechanisms may result in new treatment strategies for VTE prevention and improvement of survival.


Assuntos
Antígeno CA-19-9/metabolismo , Neoplasias Pancreáticas/complicações , Tromboplastina/metabolismo , Trombose/etiologia , Idoso , Idoso de 80 Anos ou mais , Estudos de Coortes , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Trombose/metabolismo
10.
Clin Chem ; 62(1): 188-97, 2016 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-26585923

RESUMO

BACKGROUND: Direct and calculated measures of lipoprotein fractions for cardiovascular risk assessment suffer from analytical inaccuracy in certain dyslipidemic and pathological states, most commonly hypertriglyceridemia. LC-MS/MS has proven suitable for multiplexed quantification and phenotyping of apolipoproteins. We developed and provisionally validated an automated assay for quantification of apolipoprotein (apo) A-I, B, C-I, C-II, C-III, and E and simultaneous qualitative assessment of apoE phenotypes. METHODS: We used 5 value-assigned human serum pools for external calibration. Serum proteins were denatured, reduced, and alkylated according to standard mass spectrometry-based proteomics procedures. After trypsin digestion, peptides were analyzed by LC-MS/MS. For each peptide, we measured 2 transitions. We compared LC-MS/MS results to those obtained by an immunoturbidimetric assay or ELISA. RESULTS: Intraassay CVs were 2.3%-5.5%, and total CVs were 2.5%-5.9%. The LC-MS/MS assay correlated (R = 0.975-0.995) with immunoturbidimetric assays with Conformité Européenne marking for apoA-I, apoB, apoC-II, apoC-III, and apoE in normotriglyceridemic (n = 54) and hypertriglyceridemic (n = 46) sera. Results were interchangeable for apoA-I ≤3.0 g/L (Deming slope 1.014) and for apoB-100 ≤1.8 g/L (Deming slope 1.016) and were traceable to higher-order standards. CONCLUSIONS: The multiplex format provides an opportunity for new diagnostic and pathophysiologic insights into types of dyslipidemia and allows a more personalized approach for diagnosis and treatment of lipid abnormalities.


Assuntos
Apolipoproteínas/sangue , Automação , Dislipidemias/sangue , Dislipidemias/diagnóstico , Fenótipo , Espectrometria de Massas em Tandem , Cromatografia Líquida de Alta Pressão , Ensaio de Imunoadsorção Enzimática , Humanos , Nefelometria e Turbidimetria , Proteômica
11.
Methods ; 81: 74-85, 2015 Jun 15.
Artigo em Inglês | MEDLINE | ID: mdl-25766926

RESUMO

A fully automated workflow was developed and validated for simultaneous quantification of the cardiovascular disease risk markers apolipoproteins A-I (apoA-I) and B-100 (apoB-100) in clinical sera. By coupling of stable-isotope standards and capture by anti-peptide antibodies (SISCAPA) for enrichment of proteotypic peptides from serum digests to matrix-assisted laser desorption/ionization time-of-flight (MALDI-TOF) MS detection, the standardized platform enabled rapid, liquid chromatography-free quantification at a relatively high throughput of 96 samples in 12h. The average imprecision in normo- and triglyceridemic serum pools was 3.8% for apoA-I and 4.2% for apoB-100 (4 replicates over 5 days). If stored properly, the MALDI target containing enriched apoA-1 and apoB-100 peptides could be re-analyzed without any effect on bias or imprecision for at least 7 days after initial analysis. Validation of the workflow revealed excellent linearity for daily calibration with external, serum-based calibrators (R(2) of 0.984 for apoA-I and 0.976 for apoB-100 as average over five days), and absence of matrix effects or interference from triglycerides, protein content, hemolysates, or bilirubins. Quantification of apoA-I in 93 normo- and hypertriglyceridemic clinical sera showed good agreement with immunoturbidimetric analysis (slope = 1.01, R(2) = 0.95, mean bias = 4.0%). Measurement of apoB-100 in the same clinical sera using both methods, however, revealed several outliers in SISCAPA-MALDI-TOF-MS measurements, possibly as a result of the lower MALDI-TOF-MS signal intensity (slope = 1.09, R(2) = 0.91, mean bias = 2.0%). The combination of analytical performance, rapid cycle time and automation potential validate the SISCAPA-MALDI-TOF-MS platform as a valuable approach for standardized and high-throughput quantification of apoA-I and apoB-100 in large sample cohorts.


Assuntos
Apolipoproteína A-I/sangue , Apolipoproteína B-100/sangue , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Anticorpos Monoclonais , Apolipoproteína A-I/imunologia , Apolipoproteína B-100/imunologia , Biomarcadores/sangue , Calibragem , Humanos , Fluxo de Trabalho
12.
J Proteome Res ; 14(2): 928-42, 2015 Feb 06.
Artigo em Inglês | MEDLINE | ID: mdl-25494833

RESUMO

Clinically actionable quantification of protein biomarkers by mass spectrometry (MS) requires analytical performance in concordance with quality specifications for diagnostic tests. Laboratory-developed tests should, therefore, be validated in accordance with EN ISO 15189:2012 guidelines for medical laboratories to demonstrate competence and traceability along the entire workflow, including the selected standardization strategy and the phases before, during, and after proteolysis. In this study, bias and imprecision of a previously developed MS method for quantification of serum apolipoproteins A-I (Apo A-I) and B (Apo B) were thoroughly validated according to Clinical and Laboratory Standards Institute (CLSI) guidelines EP15-A2 and EP09-A3, using 100 patient sera and either stable-isotope labeled (SIL) peptides or SIL-Apo A-I as internal standard. The systematic overview of error components assigned sample preparation before the first 4 h of proteolysis as major source (∼85%) of within-sample imprecision without external calibration. No improvement in imprecision was observed with the use of SIL-Apo A-I instead of SIL-peptides. On the contrary, when the use of SIL-Apo A-I was combined with external calibration, imprecision improved significantly (from ∼9% to ∼6%) as a result of the normalization for matrix effects on linearity. A between-sample validation of bias in 100 patient sera further supported the presence of matrix effects on digestion completeness and additionally demonstrated specimen-specific biases associated with modified peptide sequences or alterations in protease activity. In conclusion, the presented overview of bias and imprecision components contributes to a better understanding of the sources of errors in MS-based protein quantification and provides valuable recommendations to assess and control analytical quality in concordance with the requirements for clinical use.


Assuntos
Fragmentos de Peptídeos/análise , Fragmentos de Peptídeos/normas , Proteômica/métodos , Proteômica/normas , Proteínas Sanguíneas/análise , Proteínas Sanguíneas/química , Cromatografia Líquida , Humanos , Marcação por Isótopo , Fragmentos de Peptídeos/sangue , Fragmentos de Peptídeos/química , Reprodutibilidade dos Testes , Espectrometria de Massas em Tandem , Tripsina
13.
Clin Chem Lab Med ; 53(10): 1547-56, 2015 Sep 01.
Artigo em Inglês | MEDLINE | ID: mdl-25719331

RESUMO

BACKGROUND: The StatSensor® Xpress-i™, a point-of-care system for blood creatinine measurement, offers patients the possibility of self-monitoring creatinine. In this study, the analytical performance of the StatSensor® for both detecting current renal function and monitoring renal (dys)function in kidney transplant patients was examined. METHODS: Accuracy of the StatSensor® with capillary and venous whole blood was evaluated and compared to an isotopic dilution mass spectrometry (IDMS)-traceable enzymatic creatinine test in venous serum (n=138). Twenty Li-heparin samples were compared to the IDMS reference method performed by a Joint Committee for Traceability in Laboratory Medicine (JCTLM)-listed reference laboratory (RfB, Bonn, Germany). To evaluate StatSensor®'s suitability to monitor kidney function, both venous and capillary samples were obtained in 20 hospitalized transplantation patients. Venous samples were analyzed with an IDMS-traceable enzymatic test, capillary samples were measured using the StatSensor®. For all 2-day intervals, percentage change in creatinine was compared between both methods. RESULTS: The StatSensor® did not meet total allowable error criterion of 6.9%. Average overall CVa for the StatSensor® was 10.4% and 5.2% for capillary and venous whole blood results, respectively. Overall CVa for the central laboratory serum creatinine method was <1.5%. For monitoring renal (dys)function, total agreement of the StatSensor® with an IDMS-traceable enzymatic test was 68% using a 10% Δ change. No significant differences were found between the changes observed by both methods. CONCLUSIONS: Capillary blood testing with the StatSensor® is not advisable for determining current renal function with a single creatinine measurement in kidney transplant patients, mainly due to excessive analytical imprecision. However, our results suggest that capillary blood testing with the StatSensor® can be used for daily trend monitoring of kidney function after renal transplantation.


Assuntos
Análise Química do Sangue/instrumentação , Creatinina/sangue , Transplante de Rim/métodos , Adulto , Análise Química do Sangue/métodos , Feminino , Taxa de Filtração Glomerular , Testes Hematológicos/instrumentação , Testes Hematológicos/métodos , Humanos , Testes de Função Renal/métodos , Masculino , Pessoa de Meia-Idade , Monitorização Fisiológica/instrumentação , Monitorização Fisiológica/métodos , Sistemas Automatizados de Assistência Junto ao Leito , Reprodutibilidade dos Testes
15.
Sci Rep ; 14(1): 12901, 2024 06 05.
Artigo em Inglês | MEDLINE | ID: mdl-38839764

RESUMO

Early kidney injury may be detected by urinary markers, such as beta-2 microglobulin (B2M), tissue inhibitor of metalloproteinases-2 (TIMP-2), insulin-like growth factor-binding protein 7 (IGFBP7), kidney injury molecule-1 (KIM-1) and/or neutrophil gelatinase-associated lipocalin (NGAL). Of these biomarkers information on pathophysiology and reference ranges in both healthy and diseased populations are scarce. Differences in urinary levels of B2M, TIMP-2, IGFBP7, KIM-1 and NGAL were compared 24 h before and after nephrectomy in 38 living kidney donors from the REnal Protection Against Ischaemia-Reperfusion in transplantation study. Linear regression was used to assess the relation between baseline biomarker concentration and kidney function 1 year after nephrectomy. Median levels of urinary creatinine and creatinine standardized B2M, TIMP-2, IGFBP7, KIM-1, NGAL, and albumin 24 h before nephrectomy in donors were 9.4 mmol/L, 14 µg/mmol, 16 pmol/mmol, 99 pmol/mmol, 63 ng/mmol, 1390 ng/mmol and 0.7 mg/mmol, with median differences 24 h after nephrectomy of - 0.9, + 1906, - 7.1, - 38.3, - 6.9, + 2378 and + 1.2, respectively. The change of donor eGFR after 12 months per SD increment at baseline of B2M, TIMP-2, IGFBP7, KIM-1 and NGAL was: - 1.1, - 2.3, - 0.7, - 1.6 and - 2.8, respectively. Urinary TIMP-2 and IGFBP7 excretion halved after nephrectomy, similar to urinary creatinine, suggesting these markers predominantly reflect glomerular filtration. B2M and NGAL excretion increased significantly, similar to albumin, indicating decreased proximal tubular reabsorption following nephrectomy. KIM-1 did not change considerably after nephrectomy. Even though none of these biomarkers showed a strong relation with long-term donor eGFR, these results provide valuable insight into the pathophysiology of these urinary biomarkers.


Assuntos
Biomarcadores , Proteínas de Ligação a Fator de Crescimento Semelhante a Insulina , Nefrectomia , Inibidor Tecidual de Metaloproteinase-2 , Microglobulina beta-2 , Humanos , Nefrectomia/métodos , Nefrectomia/efeitos adversos , Inibidor Tecidual de Metaloproteinase-2/urina , Microglobulina beta-2/urina , Masculino , Feminino , Pessoa de Meia-Idade , Proteínas de Ligação a Fator de Crescimento Semelhante a Insulina/urina , Adulto , Biomarcadores/urina , Transplante de Rim/efeitos adversos , Doadores Vivos , Rim/cirurgia , Rim/fisiopatologia , Rim/metabolismo , Receptor Celular 1 do Vírus da Hepatite A/metabolismo , Receptor Celular 1 do Vírus da Hepatite A/análise , Creatinina/urina , Lipocalina-2/urina
16.
J Appl Lab Med ; 9(6): 949-963, 2024 Nov 04.
Artigo em Inglês | MEDLINE | ID: mdl-39239905

RESUMO

BACKGROUND: To evaluate the clinical performance and effectiveness of a multiplex apolipoprotein panel in the context of cardiovascular precision diagnostics, clinical samples of patients with recent acute coronary syndrome in the ODYSSEY OUTCOMES trial were measured by quantitative clinical chemistry proteomics (qCCP). The ISO15189-accredited laboratory setting, including the total testing process (TTP), served as a foundation for this study. Consequently, tailored quality assurance measures needed to be designed and implemented to suit the demands of a multiplex LC-MS/MS test. METHODS: Nine serum apolipoproteins were measured in 23 376 samples with a laboratory-developed multiplex apolipoprotein test on 4 Agilent 6495 LC-MS/MS systems. A fit-for-purpose process was designed with tailored additions enhancing the accredited laboratory infrastructure and the TTP. Quality assurance was organized in 3 steps: system suitability testing (SST), internal quality control (IQC) evaluation with adjusted Westgard rules to fit a multiplex test, and interpeptide agreement analysis. Data was semi-automatically evaluated with a custom R script. RESULTS: LC-MS/MS analyses were performed with the following between-run CVs: for apolipoprotein (Apo) (a) 6.2%, Apo A-I 2.3%, Apo A-II 2.1%, Apo A-IV 2.9%, Apo B 1.9%, Apo C-I 3.3%, Apo C-II 3.3%, Apo C-III 2.7%, and for Apo E 3.3% and an average interpeptide agreement Pearson r of 0.981. CONCLUSIONS: This is the first study of its kind in which qCCP was performed at this scale. This research successfully demonstrates the feasibility of high-throughput LC-MS/MS applications in large clinical trials. ClinicalTrials.gov Registration Number: NCT01663402.


Assuntos
Apolipoproteínas , Proteômica , Controle de Qualidade , Espectrometria de Massas em Tandem , Humanos , Síndrome Coronariana Aguda/sangue , Síndrome Coronariana Aguda/diagnóstico , Apolipoproteínas/sangue , Cromatografia Líquida/métodos , Cromatografia Líquida/normas , Proteômica/métodos , Proteômica/normas , Garantia da Qualidade dos Cuidados de Saúde , Espectrometria de Massas em Tandem/métodos , Espectrometria de Massas em Tandem/normas , Ensaios Clínicos Fase III como Assunto
17.
J Proteome Res ; 12(12): 5760-74, 2013 Dec 06.
Artigo em Inglês | MEDLINE | ID: mdl-24168082

RESUMO

Implementation of quantitative clinical chemistry proteomics (qCCP) requires targeted proteomics approaches, usually involving bottom-up multiple reaction monitoring-mass spectrometry (MRM-MS) with stable-isotope labeled standard (SIS) peptides, to move toward more accurate measurements. Two aspects of qCCP that deserve special attention are (1) proper calibration and (2) the assurance of consistent digestion. Here, we describe the evaluation of tryptic digestion efficiency by monitoring various signature peptides, missed cleavages, and modifications during proteolysis of apolipoprotein A-I and B in normo- and hypertriglyceridemic specimens. Absolute quantification of apolipoprotein A-I and B was performed by LC-MRM-MS with SIS peptide internal standards at two time points (4 and 20 h), using three native protein calibrators. Comparison with an immunoturbidimetric assay revealed recoveries of 99.4 ± 6.5% for apolipoprotein A-I and 102.6 ± 7.2% for apolipoprotein B after 4 h of trypsin digestion. Protein recoveries after 20 h trypsin incubation equaled 95.9 ± 6.9% and 106.0 ± 10.0% for apolipoproteins A-I and B, respectively. In conclusion, the use of metrologically traceable, native protein calibrators looks promising for accurate quantification of apolipoprotein A-I and B. Selection of rapidly formed peptides, that is, with no or minor missed cleavages, and the use of short trypsin incubation times for these efficiently cleaved peptides are likely to further reduce the variability introduced by trypsin digestion and to improve the traceability of test results to reach the desirable analytical performance for clinical chemistry application.


Assuntos
Apolipoproteína A-I/sangue , Apolipoproteínas B/sangue , Cromatografia Líquida/normas , Hipertrigliceridemia/sangue , Espectrometria de Massas/normas , Fragmentos de Peptídeos/isolamento & purificação , Sequência de Aminoácidos , Apolipoproteína A-I/química , Apolipoproteínas B/química , Calibragem , Estudos de Casos e Controles , Humanos , Dados de Sequência Molecular , Nefelometria e Turbidimetria , Fragmentos de Peptídeos/química , Proteólise , Padrões de Referência , Reprodutibilidade dos Testes , Tripsina/química
20.
J Am Soc Mass Spectrom ; 32(3): 636-647, 2021 Mar 03.
Artigo em Inglês | MEDLINE | ID: mdl-33522792

RESUMO

Protein mass spectrometry (MS) is an enabling technology that is ideally suited for precision diagnostics. In contrast to immunoassays with indirect readouts, MS quantifications are multiplexed and include identification of proteoforms in a direct manner. Although widely used for routine measurements of drugs and metabolites, the number of clinical MS-based protein applications is limited. In this paper, we share our experience and aim to take away the concerns that have kept laboratory medicine from implementing quantitative protein MS. To ensure added value of new medical tests and guarantee accurate test results, five key elements of test evaluation have been established by a working group within the European Federation for Clinical Chemistry and Laboratory Medicine. Moreover, it is emphasized to identify clinical gaps in the contemporary clinical pathways before test development is started. We demonstrate that quantitative protein MS tests that provide an additional layer of clinical information have robust performance and meet long-term desirable analytical performance specifications as exemplified by our own experience. Yet, the adoption of quantitative protein MS tests into medical laboratories is seriously hampered due to its complexity, lack of robotization and high initial investment costs. Successful and widespread implementation in medical laboratories requires uptake and automation of this next generation protein technology by the In-Vitro Diagnostics industry. Also, training curricula of lab workers and lab specialists should include education on enabling technologies for transitioning to precision medicine by quantitative protein MS tests.


Assuntos
Espectrometria de Massas/métodos , Proteínas/análise , Animais , Calibragem , Química Clínica/métodos , Estudos de Avaliação como Assunto , Humanos , Peptídeos/análise , Proteólise
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA