Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 5 de 5
Filtrar
1.
Catheter Cardiovasc Interv ; 91(7): 1221-1228, 2018 06.
Artigo em Inglês | MEDLINE | ID: mdl-28944613

RESUMO

OBJECTIVE: The objective of this study was to compare the safety and efficacy of a polymer-free sirolimus coated, ultrathin strut drug eluting stent (PF-SES) to its uncoated bare-metal stent (BMS) platform of identical stent architecture. BACKGROUND: Recently published randomized trials comparing BMS to DES with a focus on shortened dual-antiplatelet therapy reported incidences of stent thrombosis (ST) and bleeding complications (LEADERS FREE) in favor of drug eluting stents (DES). METHODS: Data of previously published large-sale, international, single-armed, multicenter, observational studies of ultra-thin PF-SES, and BMS were propensity score (PS) matched for selected lesion morphological and cardiovascular risk factors to compare target lesion revascularization (TLR), myocardial infarction, cardiac death, major adverse cardiac events (MACE), bleeding complications and ST rates. Primary endpoint in both studies was TLR at 9 months. RESULTS: At 9 months the rates of TLR was significantly lower in the PF-SES group as compared with patients treated with the BMS analogue of identical stent design (1.4% vs. 4.6%, P = 0.005). Likewise the 9-month MACE rates were lower in the PF-SES group (3.2% vs. 8.7%, P = 0.001) whereas there were no differences in the accumulated ST rates (0.5% vs. 1.5%, P = 0.109). Overall accumulated bleeding incidences (BARC 1-5) were not significantly different between PF-SES and BMS patients (1.8% vs. 2.7%, p = 0.388). CONCLUSIONS: PF-SES are superior over analogue BMS of identical stent architecture in daily clinical routine with lower rates of TLR and MACE in a PS-matched, unselected patient population without differences in accumulated ST rates and bleeding frequencies given the currently favored postprocedural comedication (ClinicalTrials.gov Identifier NCT02629575).


Assuntos
Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/cirurgia , Stents Farmacológicos , Metais , Intervenção Coronária Percutânea/instrumentação , Probucol/administração & dosagem , Sirolimo/administração & dosagem , Idoso , Idoso de 80 Anos ou mais , Ásia , Fármacos Cardiovasculares/efeitos adversos , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Europa (Continente) , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Complicações Pós-Operatórias/etiologia , Complicações Pós-Operatórias/mortalidade , Complicações Pós-Operatórias/cirurgia , Probucol/efeitos adversos , Pontuação de Propensão , Estudos Prospectivos , Desenho de Prótese , Sistema de Registros , Medição de Risco , Fatores de Risco , Sirolimo/efeitos adversos , Fatores de Tempo , Resultado do Tratamento
2.
Catheter Cardiovasc Interv ; 91(3): 387-395, 2018 02 15.
Artigo em Inglês | MEDLINE | ID: mdl-28471086

RESUMO

OBJECTIVES: to compare the occurrence of clinical events in diabetics treated with the Absorb bioresorbable vascular scaffold (Absorb BVS; Abbott Vascular, Santa Clara, CA) versus everolimus-eluting metal stents (EES; XIENCE V; Abbott Vascular, Santa Clara, CA) BACKGROUND: There are limited data dedicated to clinical outcomes of diabetic patients treated with bioresorbable scaffolds (BRS) at 2-year horizon. METHODS: The present study included 812 patients in the ABSORB EXTEND study in which a total of 215 diabetic patients were treated with Absorb BVS. In addition, 882 diabetic patients treated with EES in pooled data from the SPIRIT clinical program (SPIRIT II, SPIRIT III and SPIRIT IV trials) were used for comparison by applying propensity score matching using 29 different variables. The primary endpoint was ischemia driven major adverse cardiac events (ID-MACE), including cardiac death, myocardial infarction (MI), and ischemia driven target lesion revascularization (ID-TLR). RESULTS: After 2 years, the ID-MACE rate was 6.5% in the Absorb BVS vs. 8.9% in the Xience group (P = 0.40). There was no difference for MACE components or definite/probable device thrombosis (HR: 1.43 [0.24,8.58]; P = 0.69). The occurrence of MACE was not different for both diabetic status (insulin- and non-insulin-requiring diabetes) in all time points up to the 2-year follow-up for the Absorb and Xience groups. CONCLUSION: In this largest ever patient-level pooled comparison on the treatment of diabetic patients with BRS out to two years, individuals with diabetes treated with the Absorb BVS had a similar rate of MACE as compared with diabetics treated with the Xience EES. © 2017 Wiley Periodicals, Inc.


Assuntos
Implantes Absorvíveis , Angioplastia Coronária com Balão/instrumentação , Fármacos Cardiovasculares/administração & dosagem , Doença da Artéria Coronariana/cirurgia , Diabetes Mellitus , Stents Farmacológicos , Everolimo/administração & dosagem , Idoso , Angioplastia Coronária com Balão/efeitos adversos , Angioplastia Coronária com Balão/mortalidade , Doença da Artéria Coronariana/diagnóstico por imagem , Doença da Artéria Coronariana/mortalidade , Diabetes Mellitus/diagnóstico , Diabetes Mellitus/tratamento farmacológico , Diabetes Mellitus/mortalidade , Feminino , Humanos , Hipoglicemiantes/uso terapêutico , Insulina/uso terapêutico , Masculino , Pessoa de Meia-Idade , Pontuação de Propensão , Desenho de Prótese , Fatores de Risco , Fatores de Tempo , Resultado do Tratamento
3.
Int Heart J ; 52(1): 61-3, 2011.
Artigo em Inglês | MEDLINE | ID: mdl-21321471

RESUMO

We report a 69 year old female who presented with chest pain to the Emergency Department of the National Heart Institute Malaysia. Her history revealed that she had had 2 separate episodes of chest pain beginning in 2002, resulting in total occlusion of her mid left anterior descending artery (LAD) requiring percutaneous coronary intervention and stenting on both occasions. Cine angiogram on her current admission revealed recurrent target lesion in-stent restenosis with total occlusion of the distal LAD. Intravascular ultrasound revealed multilayered suboptimally deployed stents in the LAD. Successive drug-eluting balloon deployments resulted in sustained patency of the LAD after 1 year.


Assuntos
Angioplastia Coronária com Balão , Reestenose Coronária/terapia , Stents Farmacológicos , Idoso , Angioplastia Coronária com Balão/métodos , Feminino , Humanos , Recidiva , Resultado do Tratamento
4.
AsiaIntervention ; 7(1): 54-59, 2021 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-34913003

RESUMO

AIMS: The aim of the study was to report the clinical experience, 30-day mortality and acute outcomes of patients undergoing transcatheter aortic valve implantation (TAVI) in the Asia Pacific region. METHODS AND RESULTS: The Asia Pacific TAVI registry is an international, multicentre, prospective, observational registry managed under the auspices of the Asian Pacific Society of Interventional Cardiology (APSIC). Patients undergoing TAVI in seven centres from Hong Kong, Japan, Philippines, Singapore and Taiwan, treated with TAVI devices for severe symptomatic aortic stenosis, were assessed. This first review presents the acute results and 30-day mortality. A multivariable analysis was also performed to identify independent predictors of early all-cause mortality. The enrolment was from 2009 to 2017 and a total of 1,125 patients were recruited. The 30-day mortality rate was 2.5%. Baseline logistic EuroSCORE more than 16 was independently associated with a 2.8-times increased risk of 30-day all-cause mortality (p=0.016). Post-procedural stroke (HR 4.9, p=0.008) was also associated with increased mortality. CONCLUSIONS: This initial report of the Asia Pacific TAVI registry demonstrated good acute success and low 30-day mortality. The preprocedural logistic EuroSCORE and post-procedural stroke incidence were strongly associated with acute mortality. Further attempts to reduce post-procedural stroke should be explored.

5.
JACC Cardiovasc Interv ; 6(4): 334-43, 2013 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-23523459

RESUMO

OBJECTIVES: This study sought to compare the efficacy and safety results after coronary implantation of a combined sirolimus-eluting CD34 antibody coated Combo stent (OrbusNeich Medical, Ft. Lauderdale, Florida) with the paclitaxel-eluting Taxus Liberté stent (PES) (Boston Scientific, Natick, Massachusetts). This report summarizes the first-in-man randomized, controlled multicenter REMEDEE trial (Randomized study to Evaluate the safety and effectiveness of an abluMinal sirolimus coatED bio-Engineered StEnt) angiographic, intravascular ultrasound, and clinical results up to 12 months. BACKGROUND: Drug-eluting stents have limited restenosis and reintervention but are complicated by especially late and very late stent thrombosis and accelerated neoatherosclerosis. Alternative or adjunct technologies should address these limitations. METHODS: One hundred eighty-three patients with de novo native coronary artery stenoses were randomized 2:1 to Combo stent or PES implantation. The primary endpoint is the angiographic in-stent late lumen loss at 9 months, which was tested for noninferiority between the 2 stent groups. Secondary endpoints include the occurrence of major adverse cardiac events. RESULTS: The Combo stent was found to be noninferior to the PES in 9-month angiographic in-stent late lumen loss with 0.39 ± 0.45 mm versus 0.44 ± 0.56 mm (pnoninferiority = 0.0012). At 12 months, the occurrence of major adverse cardiac events was 8.9% in the Combo group and 10.2% in the PES group (p = 0.80) with no difference in mortality, occurrence of myocardial infarction, or target lesion revascularization. No stent thrombosis was reported in either group. CONCLUSIONS: In the REMEDEE trial the Combo stent has shown to be effective by meeting the primary noninferiority angiographic endpoint and safe, with an overall low rate of clinical events in both stent groups, including no stent thrombosis up to 12 months.


Assuntos
Anticorpos/administração & dosagem , Fármacos Cardiovasculares/administração & dosagem , Materiais Revestidos Biocompatíveis , Estenose Coronária/terapia , Stents Farmacológicos , Células Endoteliais/patologia , Paclitaxel/administração & dosagem , Intervenção Coronária Percutânea/instrumentação , Sirolimo/administração & dosagem , Células-Tronco/patologia , Idoso , Antígenos CD34/imunologia , Ásia , Austrália , Brasil , Angiografia Coronária , Reestenose Coronária/etiologia , Estenose Coronária/imunologia , Estenose Coronária/mortalidade , Estenose Coronária/patologia , Trombose Coronária/etiologia , Células Endoteliais/imunologia , Europa (Continente) , Feminino , Humanos , Estimativa de Kaplan-Meier , Masculino , Pessoa de Meia-Idade , Infarto do Miocárdio/etiologia , Intervenção Coronária Percutânea/efeitos adversos , Intervenção Coronária Percutânea/mortalidade , Desenho de Prótese , Fatores de Risco , Células-Tronco/imunologia , Fatores de Tempo , Resultado do Tratamento , Ultrassonografia de Intervenção
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA