Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 120
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
J Cardiovasc Electrophysiol ; 35(6): 1101-1111, 2024 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-38519418

RESUMO

INTRODUCTION: Limited data exist on pulsed-field ablation (PFA) in patients with persistent atrial fibrillation (PeAF) undergoing left atrial posterior wall isolation (LAPWI). METHODS: The Advanced TecHnologies For SuccEssful AblatioN of AF in Clinical Practice (ATHENA) prospective registry included consecutive patients referred for PeAF catheter ablation at 9 Italian centers, treated with the FARAPULSETM-PFA system. The primary efficacy and safety study endpoints were the acute LAPWI rate, freedom from arrhythmic recurrences and the incidence of major periprocedural complications. Patients undergoing pulmonary vein isolation (PVI) alone, PWI + LAPWI and redo procedures were compared. RESULTS: Among 249 patients, 21.7% had long-standing PeAF, 79.5% were male; mean age was 63 ± 9 years. LAPWI was performed in 57.6% of cases, with 15.3% being redo procedures. Median skin-to-skin times (PVI-only 68 [60-90] vs. PVI + LAPWI 70 [59-88] mins) did not differ between groups. 45.8% LAPWI cases were approached with a 3D-mapping system, and 37.3% with intracardiac echocardiography. LAPWI was achieved in all patients by means of PFA alone, in 88.8% cases at first pass. LAPWI was validated either by an Ultrahigh-density mapping system or by recording electrical activity + pacing maneuvers. No major complications occurred, while 2.4% minor complications were detected. During a median follow-up of 273 [191-379] days, 41 patients (16.5%) experienced an arrhythmic recurrence after the 90-day blanking period, with a mean time to recurrence of 223 ± 100 days and no differences among ablation strategies. CONCLUSION: LAPWI with PFA demonstrates feasibility, rapidity, and safety in real-world practice, offering a viable alternative for PeAF patients. LAPWI is achievable even with a fluoroscopy-only method and does not significantly extend overall procedural times.


Assuntos
Potenciais de Ação , Fibrilação Atrial , Ablação por Cateter , Frequência Cardíaca , Veias Pulmonares , Recidiva , Sistema de Registros , Humanos , Fibrilação Atrial/cirurgia , Fibrilação Atrial/fisiopatologia , Fibrilação Atrial/diagnóstico , Masculino , Feminino , Veias Pulmonares/cirurgia , Veias Pulmonares/fisiopatologia , Pessoa de Meia-Idade , Ablação por Cateter/efeitos adversos , Idoso , Estudos Prospectivos , Fatores de Tempo , Itália , Fatores de Risco , Átrios do Coração/fisiopatologia , Átrios do Coração/cirurgia , Resultado do Tratamento , Intervalo Livre de Progressão
2.
Mol Psychiatry ; 28(10): 4363-4373, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37644174

RESUMO

Converging evidence suggests that schizophrenia (SZ) with primary, enduring negative symptoms (i.e., Deficit SZ (DSZ)) represents a distinct entity within the SZ spectrum while the neurobiological underpinnings remain undetermined. In the largest dataset of DSZ and Non-Deficit (NDSZ), we conducted a meta-analysis of data from 1560 individuals (168 DSZ, 373 NDSZ, 1019 Healthy Controls (HC)) and a mega-analysis of a subsampled data from 944 individuals (115 DSZ, 254 NDSZ, 575 HC) collected across 9 worldwide research centers of the ENIGMA SZ Working Group (8 in the mega-analysis), to clarify whether they differ in terms of cortical morphology. In the meta-analysis, sites computed effect sizes for differences in cortical thickness and surface area between SZ and control groups using a harmonized pipeline. In the mega-analysis, cortical values of individuals with schizophrenia and control participants were analyzed across sites using mixed-model ANCOVAs. The meta-analysis of cortical thickness showed a converging pattern of widespread thinner cortex in fronto-parietal regions of the left hemisphere in both DSZ and NDSZ, when compared to HC. However, DSZ have more pronounced thickness abnormalities than NDSZ, mostly involving the right fronto-parietal cortices. As for surface area, NDSZ showed differences in fronto-parietal-temporo-occipital cortices as compared to HC, and in temporo-occipital cortices as compared to DSZ. Although DSZ and NDSZ show widespread overlapping regions of thinner cortex as compared to HC, cortical thinning seems to better typify DSZ, being more extensive and bilateral, while surface area alterations are more evident in NDSZ. Our findings demonstrate for the first time that DSZ and NDSZ are characterized by different neuroimaging phenotypes, supporting a nosological distinction between DSZ and NDSZ and point toward the separate disease hypothesis.


Assuntos
Esquizofrenia , Humanos , Esquizofrenia/genética , Imageamento por Ressonância Magnética , Neuroimagem , Lobo Parietal , Síndrome , Córtex Cerebral/diagnóstico por imagem
3.
J Cardiovasc Electrophysiol ; 34(8): 1781-1784, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37493490

RESUMO

INTRODUCTION: Cardiac involvement is common and may become clinically relevant in approximately 5%-10% of patients with systemic sarcoidosis. Although reduced left ventricular ejection fraction is a recognized predictor of mortality, recent studies have suggested an increased risk of ventricular arrhythmia (VAs) and sudden cardiac death (SCD) in patients with cardiac sarcoidosis (CS) and evidence of late gadolinium enhancement-cardiac magnetic resonance (LGE-CMR), irrespective of the underlying left ventricular systolic function. We performed a meta-analysis to assess the correlation between VAs/SCD and presence of LGE-CMR in CS patients. METHODS: We systematically searched Medline, Embase, and Cochrane electronic databases up to January 2, 2023, for studies enrolling patients with suspected or confirmed CS undergoing LGE-CMR. Clinical outcomes of interest included clinically relevant VAs, defined as sustained ventricular tachycardia, ventricular fibrillation, SCD, or aborted SCD during follow-up. The effect size was estimated using a random-effect model as risk ratio (RR) and relative 95% confidence interval (CI). RESULTS: A total of 14 studies fulfilled the selection criteria and were included in the final analysis. Among 1273 patients, LGE was detected in 465 (36.5%; Group LGE+). Males accounted for 45.2% (95% CI: 40.5%-55.7%) of the total population and the average age was 56.8 (95% CI: 52.7%-60.9) years. A total of 104 (22.3%) of 465 LGE+ patients experienced a clinically relevant VA, compared to 6 (0.7%) of 808 LGE- ones. LGE+ was associated with a ninefold increased risk in life-threatening VAs (22.3% vs. 0.7%; RR = 9.52; 95% CI [5.18-17.49]; p < .0001) compared to patients without LGE (heterogeneity I2 = 0%). CONCLUSION: In our meta-analysis, LGE+ in patients with CS was associated with a ninefold increased risk in life-threatening VAs compared to patients without LGE.


Assuntos
Miocardite , Sarcoidose , Humanos , Masculino , Pessoa de Meia-Idade , Arritmias Cardíacas/etiologia , Arritmias Cardíacas/complicações , Meios de Contraste , Morte Súbita Cardíaca/etiologia , Morte Súbita Cardíaca/epidemiologia , Gadolínio , Imagem Cinética por Ressonância Magnética , Espectroscopia de Ressonância Magnética/efeitos adversos , Miocardite/complicações , Prognóstico , Medição de Risco , Fatores de Risco , Sarcoidose/complicações , Sarcoidose/diagnóstico por imagem , Volume Sistólico , Função Ventricular Esquerda
4.
Europace ; 26(1)2023 Dec 28.
Artigo em Inglês | MEDLINE | ID: mdl-38245007

RESUMO

AIMS: Pulsed field ablation (PFA) has emerged as a novel, non-thermal energy source to selectively ablate cardiac tissue. We describe a multicentre experience on pulmonary vein isolation (PVI) via the pentaspline Farapulse™ PFA system vs. thermal-based technologies in a propensity score-matched population of paroxysmal atrial fibrillation (PAF) patients. METHODS AND RESULTS: Propensity score matching was adopted to compare PVI-only ablation outcomes via the Farawave™ system (Group PFA), cryoballoon (Group CRYO), or focal radiofrequency (Group RF) (PFA:CRYO:RF ratio = 1:2:2). Among 1572 (mean age: 62.4 ± 11.3 years; 42.5% females) PAF patients undergoing first time PVI with either PFA (n = 174), CRYO (n = 655), or RF (n = 743), propensity score matching yielded 174 PFA, 348 CRYO, and 348 RF patients. First-pass isolation was achieved in 98.8% of pulmonary veins (PVs) with PFA, 81.5% with CRYO, and 73.1% with RF (P < 0.001). Procedural and dwell times were significantly shorter with PFA, whereas the availability of a 3D mapping system led to a significant reduction in X-ray exposure with RF. Overall complication rates were 3.4% (n = 6) with PFA, 8.6% (n = 30) with CRYO, and 5.5% (n = 19) with RF (P = 0.052). The 1-year Kaplan-Meier estimated freedom from any atrial tachyarrhythmia was 79.3% with PFA, 74.7% with CRYO, and 72.4% with RF (log-rank P-value: 0.24). Among 145 repeat ablation procedures, PV reconnection rate was 19.1% after PFA, 27.5% after CRYO, and 34.8% after RF (P = 0.01). CONCLUSION: Pulsed field ablation contributed to significantly shorter procedural times. Follow-up data showed a similar arrhythmia freedom, although a higher rate of PV reconnection was documented in post-CRYO and post-RF redo procedures.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Masculino , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Criocirurgia/efeitos adversos , Criocirurgia/métodos , Pontuação de Propensão , Resultado do Tratamento , Átrios do Coração , Veias Pulmonares/cirurgia , Ablação por Cateter/efeitos adversos , Ablação por Cateter/métodos , Recidiva
5.
Pacing Clin Electrophysiol ; 46(8): 942-947, 2023 08.
Artigo em Inglês | MEDLINE | ID: mdl-37378419

RESUMO

INTRODUCTION: Cephalic vein cutdown (CVC) and axillary vein puncture (AVP) are both recommended for transvenous implantation of leads for cardiac implantable electronic devices (CIEDs). Nonetheless, it is still debated which of the two techniques has a better safety and efficacy profile. METHODS: We systematically searched Medline, Embase, and Cochrane electronic databases up to September 5, 2022, for studies that evaluated the efficacy and safety of AVP and CVC reporting at least one clinical outcome of interest. The primary endpoints were acute procedural success and overall complications. The effect size was estimated using a random-effect model as risk ratio (RR) and relative 95% confidence interval (CI). RESULTS: Overall, seven studies were included, which enrolled 1771 and 3067 transvenous leads (65.6% [n = 1162] males, average age 73.4 ± 14.3 years). Compared to CVC, AVP showed a significant increase in the primary endpoint (95.7 % vs. 76.1 %; RR: 1.24; 95% CI: 1.09-1.40; p = .001) (Figure 1). Total procedural time (mean difference [MD]: -8.25 min; 95% CI: -10.23 to -6.27; p < .0001; I2  = 0%) and venous access time (MD: -6.24 min; 95% CI: -7.01 to -5.47; p < .0001; I2  = 0%) were significantly shorter with AVP compared to CVC. No differences were found between AVP and CVC for incidence overall complications (RR: 0.56; 95% CI: 0.28-1.10; p = .09), pneumothorax (RR: 0.72; 95% CI: 0.13-4.0; p = .71), lead failure (RR: 0.58; 95% CI: 0.23-1.48; p = .26), pocket hematoma/bleeding (RR: 0.58; 95% CI: 0.15-2.23; p = .43), device infection (RR: 0.95; 95% CI: 0.14-6.60; p = .96) and fluoroscopy time (MD: -0.24 min; 95% CI: -0.75 to 0.28; p = .36). CONCLUSION: Our meta-analysis suggests that AVP may improve procedural success and reduce total procedural time and venous access time compared to CVC.


Assuntos
Veia Axilar , Venostomia , Masculino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Veia Axilar/cirurgia , Venostomia/métodos , Veia Subclávia , Punções/métodos , Coração
6.
Pacing Clin Electrophysiol ; 46(11): 1302-1309, 2023 11.
Artigo em Inglês | MEDLINE | ID: mdl-37846769

RESUMO

INTRODUCTION: Recently, a new cryoballoon (CB) technology (POLARx; Boston Scientific) has come onto the market. Preliminary data have shown that its acute safety and efficacy are similar to those of the first-generation CB. The aim of this study was to assess the medium-term outcome of pulmonary vein isolation (PVI) with the POLARxTM CB in a large multicenter registry. METHODS: We prospectively collected data on 125 consecutive patients with paroxysmal atrial fibrillation (AF) who underwent PVI by means of a novel CB system. Two cases of transient phrenic nerve palsy occurred, with full recovery in the 48h post procedure; no major procedure-related adverse events were reported. During the 90-day blanking period, 4 (3.2%) patients experienced an early recurrence. After the blanking period, over a mean follow-up of 411 ± 62 days, 19 patients (15.2%) suffered an AF/atrial tachycardia (AT) recurrence. The 1-year freedom from AF/AT recurrence was 86.4% (n = 17): 10 (8%) patients had an AF recurrence, 6 (4.8%) had an AT occurrence and 1 (0.8%) suffered both events. Patients with AF/AT recurrences had both a shorter deflation time and total deflation time. Moreover, CB ablations with measured TTI < 90 s and TTI < 60 s were more frequent in patients without AF/AT recurrence (88.5% and 77.4%, respectively) than in those who experienced at least one AF/AT recurrence (67.5% and 55.0%, p = .001 and p = .005, respectively). CONCLUSION: The novel POLARx cryo-balloon system is safe and effective for PV isolation, displaying a 1-year freedom from atrial arrhythmia recurrence of 86.4%, which is in line to that reported with AFA-Pro CB or RF ablation. CLINICAL TRIAL REGISTRATION: Catheter Ablation of Arrhythmias with a High-Density Mapping System in Real-World Practice (CHARISMA). URL: http://clinicaltrials.gov/ Identifier: NCT03793998. Registration date: January 4, 2019.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Criocirurgia , Veias Pulmonares , Humanos , Veias Pulmonares/cirurgia , Resultado do Tratamento , Criocirurgia/métodos , Itália/epidemiologia , Sistema de Registros , Ablação por Cateter/métodos , Recidiva
7.
J Cardiovasc Electrophysiol ; 33(7): 1414-1424, 2022 07.
Artigo em Inglês | MEDLINE | ID: mdl-35524404

RESUMO

INTRODUCTION: Low-voltage activity beyond pulmonary veins (PVs) may contribute to the failure of ablation of atrial fibrillation (AF) in the long term. We aimed to assess the presence of gaps (PVG) and residual potential (residual antral potential [RAP]) within the antral scar by means of an ultra-high-density mapping (UHDM) system. METHODS: We studied consecutive patients from the CHARISMA registry who were undergoing AF ablation and had complete characterization of residual PV antral activity. The Lumipoint™ (Boston Scientific) map-analysis tool was used sequentially on each PV component. The ablation endpoint was PV isolation (PVI) and electrical quiescence in the antral region. RESULTS: Fifty-eight cases of AF ablation were analyzed. A total of 86 PVGs in 34 (58.6%) patients and 44 RAPs in 34 patients (58.6%) were found. In 16 (27.6%) cases, we found at least one RAP in patients with complete absence of PV conduction. RAPs showed a lower mean voltage than PVG (0.3 ± 0.2 mV vs. 0.7 ± 0.5 mV, p < .0001), whereas the mean number of electrogram peaks was higher (8.4 ± 1.4 vs. 3.2 ± 1.5, p < .0001). The percentage of patients in whom RAPs were detected through Lumipoint™ was higher than through propagation map analysis (58.6% vs. 36.2%, p = .025). Acute procedural success was 100%, with all PVs successfully isolated and RAPs completely abolished in all study patients. During a mean follow-up of 453 ± 133 days, 6 patients (10.3%) suffered an AF/AT recurrence. CONCLUSION: Local vulnerabilities in antral lesion sets were easily discernible by means of the UHDM system in both de novo and redo patients when no PV conduction was present.


Assuntos
Fibrilação Atrial , Ablação por Cateter , Veias Pulmonares , Fibrilação Atrial/diagnóstico , Fibrilação Atrial/cirurgia , Ablação por Cateter/efeitos adversos , Humanos , Veias Pulmonares/cirurgia , Recidiva , Sistema de Registros , Resultado do Tratamento
8.
Pacing Clin Electrophysiol ; 45(12): 1409-1414, 2022 12.
Artigo em Inglês | MEDLINE | ID: mdl-36214206

RESUMO

INTRODUCTION: The implantable cardioverter defibrillator (ICD) has been demonstrated to successfully prevent sudden cardiac death (SCD) in children and young adults. A wide range of device-related complications/malfunctions have been described, which depend on the intrinsic design of the defibrillation system (transvenous-implantable cardioverter defibrillator [TV-ICD] vs. subcutaneous-implantable cardioverter defibrillator [S-ICD]). OBJECTIVE: To compare the device-related complications and inappropriate shocks with TV-ICD versus S-ICD. METHODS AND RESULTS: Electronic databases were queried for studies focusing on the prevention of SCD in children and young adults with TV-ICD or S-ICD. The effect size was estimated using a random-effect model as odds ratio (OR) and relative 95% confidence interval (CI). The primary endpoint was a composite of any device-related complications and inappropriate shocks. We identified a total of five studies including 236 patients (Group S-ICD: 76 patients; Group TV-ICD: 160 patients) with a mean follow-up time of 54.2 ± 24.9 months. S-ICD implantation contributed to a significant reduction in the risk of the primary endpoint of any device-related complications and inappropriate shocks (OR: 0.18; 95% CI: 0.05-0.73; p = .02). S-ICD was also associated with a significantly lower incidence of inappropriate shocks (OR: 0.28; 95% CI: 0.11-0.74; p = .01) and lead-related complications (OR: 0.18; 95% CI: 0.05-0.66; p = .01). A trend toward a higher risk of pocket complications (OR: 5.91; 95% CI: 0.98-35.63; p = .05) was recorded in patients with S-ICD. CONCLUSION: Children and young adults undergoing S-ICD implantation may have a lower risk of a composite of device-related complications and inappropriate shocks, compared to TV-ICD patients.


Assuntos
Morte Súbita Cardíaca , Desfibriladores Implantáveis , Criança , Humanos , Desfibriladores Implantáveis/efeitos adversos , Adolescente , Morte Súbita Cardíaca/prevenção & controle
9.
Eur Arch Psychiatry Clin Neurosci ; 272(8): 1437-1442, 2022 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-35211779

RESUMO

Attention Deficit/Hyperactivity Disorder (ADHD) is the most prevalent neurodevelopmental disorder diagnosed in the scholar age. It is associated with significant impairment in global functioning, and in moderate/severe presentations the outcome is critically dependent on pharmacological optimization of the multi-modal treatment. Methylphenidate (MPH) is the first-choice pharmacological treatment in children and adolescents with ADHD, with substantial evidence of significant efficacy and effectiveness on global functioning and symptoms' severity. There is some evidence supporting a few clinical and socio-demographic variables as predictors of pharmacological treatment prescription in children with ADHD independently of ADHD symptoms severity. However, it is warranted to investigate clinical and general psychopathological characteristics potentially associated with negative outcomes and the need for pharmacological treatment to inform appropriate prescription strategies. In this context, we compared 268 children and adolescents who were prescribed MPH (ADHD/MPH) for the first time after their first diagnostic assessment at our center, and 444 children and adolescents with ADHD (ADHD/noMPH) who were recommended non-pharmacological evidence-based interventions alone. ADHD/MPH group had higher severity of non-ADHD psychopathological symptoms compared to the ADHD/noMPH group, as documented by higher scores on the Child Behavior Checklist (CBCL) subscales, higher severity of ADHD symptoms, lower average IQ and lower adaptive levels independently of IQ. More specifically, beside externalizing symptoms, also internalizing symptoms were significantly higher in the ADHD/MPH group. The presence of significant non-ADHD psychopathology should be considered as a clinical factor associated with the need for MPH prescription in children and adolescents with ADHD.


Assuntos
Transtorno do Deficit de Atenção com Hiperatividade , Estimulantes do Sistema Nervoso Central , Metilfenidato , Criança , Adolescente , Humanos , Metilfenidato/uso terapêutico , Transtorno do Deficit de Atenção com Hiperatividade/diagnóstico , Transtorno do Deficit de Atenção com Hiperatividade/tratamento farmacológico , Estimulantes do Sistema Nervoso Central/uso terapêutico , Prescrições , Resultado do Tratamento
10.
J Cardiovasc Electrophysiol ; 32(5): 1296-1304, 2021 05.
Artigo em Inglês | MEDLINE | ID: mdl-33783875

RESUMO

BACKGROUND: No data exist on the ability of the novel Rhythmia 3-D mapping system to minimize fluoroscopy exposure during transcatheter ablation of arrhythmias. We report data on the feasibility and safety of a minimal fluoroscopic approach using this system in supraventricular tachycardia (SVT) procedures. METHODS: Consecutive patients were enrolled in the CHARISMA registry at 12 centers. All right-sided procedures performed with the Rhythmia mapping system were analyzed. The acquired electroanatomic information was used to reconstruct 3-D cardiac geometry; fluoroscopic confirmation was used whenever deemed necessary. RESULTS: Three hundred twenty-five patients (mean age = 56 ± 17 years, 57% male) were included: 152 atrioventricular nodal reentrant tachycardia, 116 atrial flutter, 41 and 16 right-sided accessory pathway and atrial tachycardia, respectively. Overall, 27 481 s of fluoroscopy were used (84.6 ± 224 s per procedure, equivalent effective dose = 1.1 ± 3.7 mSv per patient). One hundred ninety-two procedures (59.1%) were completed without the use of fluoroscopy (zero fluoroscopy, ZF). In multivariate analysis, the presence of a fellow in training (OR = 0.15, 95% CI: 0.05-0.46; p = .0008), radiofrequency application (0.99, 0.99-1.00; p = .0002), and mapping times (0.99, 0.99-1.00; p = .042) were all inversely associated with ZF approach. Acute procedural success was achieved in 97.8% of the cases (98.4 vs. 97% in the ZF vs. non-ZF group; p = .4503). During a mean of 290.7 ± 169.6 days follow-up, no major adverse events were reported, and recurrence of the primary arrhythmia was 2.5% (2.1 vs. 3% in the ZF vs. non-ZF group; p = .7206). CONCLUSIONS: The Rhythmia mapping system permits transcatheter ablation of right-sided SVT with minimal fluoroscopy exposure. Even more, in most cases, the system enables a ZF approach, without affecting safety and efficacy.


Assuntos
Ablação por Cateter , Taquicardia Supraventricular , Adulto , Idoso , Ablação por Cateter/efeitos adversos , Feminino , Fluoroscopia , Humanos , Masculino , Pessoa de Meia-Idade , Sistema de Registros , Taquicardia Supraventricular/diagnóstico por imagem , Taquicardia Supraventricular/cirurgia , Resultado do Tratamento
11.
Pacing Clin Electrophysiol ; 44(2): 327-333, 2021 02.
Artigo em Inglês | MEDLINE | ID: mdl-33382121

RESUMO

BACKGROUND/OBJECTIVES: The association between chronic heart failure (CHF) and permanent atrial fibrillation is very frequent. The repolarization duration was already found predictive for atrial fibrillation. Aim of this study was to evaluate the influence of atrial fibrillation on short period repolarization variables in decompensated CHF patients. METHOD: We used 5 min ECG recordings to assess the mean, standard deviation (SD), and normalized variance (NV) of the following variables: QT end (QTe), QT peak (QTp), and T peak to T end (Te) in 121 decompensated CHF, of whom 40 had permanent atrial fibrillation, too. We reported also the 30-day mortality. RESULTS: QTpSD (p < .01), TeSD (p < .01), QTpVN (p < .01), and TeVN (p < .01) were higher in the atrial fibrillation than among sinus rhythm CHF subjects. Multivariable logistic analysis selected only TeSD (odd ratio, o.r.: 1.32, 95% confidence interval, c.i.: 1.06-1.65, p: .015) associated with atrial fibrillation. A total of 27 patients died during the 30-days follow-up (overall mortality rate 22%), 7 (18%), and 20 (25%) respectively in the atrial fibrillation and sinus rhythm patients. Furthermore, the following variables were associated to the morality risk: NT-pro Brain Natriuretic Peptide (o.r.: 1.00, 95% c.i.: 1.00-1.00, p: .041), left ventricular end diastolic diameter (o.r.: 0.81, 95% c.i.: 0.67-0.96, p: .010), and Te mean (o.r.: 1.04, 95% c.i.: 1.02-1.09, p: .012). CONCLUSION: In decompensated CHF subjects, Te mean seems be associated to mortality and TeSD to the permanent atrial fibrillation. We could hypothesize that, during severe CHF, the multi-level ionic CHF channel derangement could be critical in influencing these non-invasive markers. (ClinicalTrials.gov number, NCT04127162).


Assuntos
Fibrilação Atrial/fisiopatologia , Eletrocardiografia , Insuficiência Cardíaca/fisiopatologia , Idoso , Idoso de 80 Anos ou mais , Fibrilação Atrial/complicações , Doença Crônica , Feminino , Insuficiência Cardíaca/complicações , Humanos , Masculino , Fatores de Tempo
12.
Pacing Clin Electrophysiol ; 44(1): 63-70, 2021 01.
Artigo em Inglês | MEDLINE | ID: mdl-33210304

RESUMO

BACKGROUND: Optimal pulmonary vein (PV) occlusion, usually verified with selective contrast injection, is mandatory to obtain an effective PV isolation during cryoballoon (CB) ablation. AIM OF THE STUDY: The purpose of this study was to verify the feasibility and the accuracy of a new dielectric sensing system in assessing PV occlusion during CB ablation in patients with atrial fibrillation (AF). METHODS: We enrolled 28 consecutive patients with paroxysmal or persistent AF. After transseptal access, a detailed image reconstruction of left atrium and PVs was achieved with an octapolar or decapolar mapping catheter (Achieve catheter, Medtronic Inc.) and KODEX-EPD system (EPD Solutions, a Philips company). The degree of PV occlusion with the inflated Arctic Front Advance Cryoballoon (Medtronic Inc.) was verified using the new "occlusion tool" software module (EPD Solutions, a Philips company) and compared to an angiogram obtained with contrast medium injection in each PV. RESULTS: A total of 105 PV CB occlusion were tested. The new occlusion tool software module showed a 91% sensitivity and 76% specificity in assessing a complete PV occlusion verified with contrast medium injection. The positive predictive value was 80%, and the negative predictive value was 88.6%. Mean procedure time was 81 ± 17 minutes. Mean fluoroscopy time was 6 ± 2 minutes. No 30-day complications were observed. CONCLUSION: The new dielectric imaging system was able to assess the degree of PV occlusion during a CB ablation with good sensitivity and specificity.


Assuntos
Fibrilação Atrial/cirurgia , Criocirurgia/métodos , Veias Pulmonares/cirurgia , Software , Fibrilação Atrial/diagnóstico por imagem , Fibrilação Atrial/fisiopatologia , Cateterismo Cardíaco , Angiografia Coronária , Criocirurgia/instrumentação , Mapeamento Epicárdico , Estudos de Viabilidade , Feminino , Humanos , Processamento de Imagem Assistida por Computador , Masculino , Pessoa de Meia-Idade , Estudos Prospectivos , Veias Pulmonares/diagnóstico por imagem , Sensibilidade e Especificidade
13.
Pacing Clin Electrophysiol ; 44(12): 2031-2040, 2021 Dec.
Artigo em Inglês | MEDLINE | ID: mdl-34606098

RESUMO

BACKGROUND: An early, comprehensive rhythm-control therapy is needed in order to treat atrial fibrillation (AF) effectively and to improve ablation outcomes. METHODS: A total of 153 consecutive patients from the CHARISMA registry undergoing AF ablation at eight centers were included. Patients with de novo PVI were classified as having undergone early treatment (ET) if the procedure was performed within 6 months after the first AF episode, and as having undergone delayed treatment (DT) if ablation was performed over 6 months after the first AF episode. RESULTS: One-hundred fifty-three patients were enrolled (69.9% male, 59 ± 10 years, 61.4% paroxysmal AF, 38.6% persistent AF). The time from the first AF episode to the ablation procedure was 1034 ± 1483 days. The ET group comprised 36 patients (25.3%), the DT group 60 (39.2%) and Redo cases were 57 (37.3%). During a mean follow-up of 366 ± 130 days, 18 patients (11.8%) suffered an AF/AT recurrence. More DT patients than ET patients suffered recurrences (15.7% vs. 2.2%, p = 0.0452) and the time to AT/AF recurrence was shorter in the group of patients who received an ablation treatment after 6 months (HR = 6.19, 95% CI: 1.7 to 21.9; p = 0.0474). On multivariate Cox analysis, only hypertension (HR = 4.86, 95% CI: 1.6 to 14.98, p = 0.0062) was independently associated with recurrences. Beyond the hypertension risk factor, ET was associated with a low risk of recurrence; recurrence rate ranged from 0% (ET patients without hypertension) to 25.0% (DT patients with hypertension). CONCLUSIONS: An early rhythm-control ablation therapy in the absence of common risk factors was associated with the lowest rate of recurrences.


Assuntos
Fibrilação Atrial/prevenção & controle , Fibrilação Atrial/cirurgia , Ablação por Cateter , Eletrocardiografia , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Recidiva , Sistema de Registros
14.
J Pediatr Hematol Oncol ; 42(6): e515-e517, 2020 08.
Artigo em Inglês | MEDLINE | ID: mdl-31449499

RESUMO

This pilot study aimed to investigate dietary changes introduced after being diagnosed with cancer in a sample of 60 consecutive children and adolescents on the basis of a self-report questionnaire. The study showed that 53% of patients changed their diet, usually "to combat the tumor" (in 47% of cases). In 1 in 2 of these cases, the health care staff were not informed about any changes. This study underscores the fact that many patients and families chose to impose dietary changes that are not always discussed with their health care staff and that may risk interfering with the continuity of a patient's treatment. It is essential to have more opportunities to speak with patients and families about this issue.


Assuntos
Dieta , Neoplasias/prevenção & controle , Neoplasias/psicologia , Autocuidado/estatística & dados numéricos , Adolescente , Adulto , Criança , Pré-Escolar , Feminino , Seguimentos , Humanos , Lactente , Recém-Nascido , Masculino , Projetos Piloto , Inquéritos e Questionários , Adulto Jovem
15.
Hum Psychopharmacol ; 35(5): e2740, 2020 09.
Artigo em Inglês | MEDLINE | ID: mdl-32785944

RESUMO

OBJECTIVE: Adult and children attention deficit/hyperactivity disorder (ADHD) share similar symptoms and responses to drugs such as methylphenidate (MPH). Yet, in Europe, these drugs remain unlicensed for adults. We aimed to assess the effects of an acute MPH challenge on the four dimensions concentration, impulsivity, tension, and general well-being in ADHD adults, and identify predictors of improvement. METHODS: Therapeutic Drug Monitoring was performed to measure MPH plasma levels. A Visual Analogue Scale was administered to patients before and after the acute MPH challenge to measure self-reported changes in the four dimensions. RESULTS: After the acute MPH challenge, our 71 patients showed significant improvement in concentration and tension. The MPH challenge dose correlated with lower patients' age, greater side effects, increased concentration (p = .008) and decreased tension (p = .001). At multiple linear regression MPH plasma levels and absence of postdose side effects predicted concentration improvement, MPH plasma levels predicted tension improvement. MPH plasma levels were significantly higher in patients who reported an improvement in concentration, tension, and impulsivity compared to nonimprovers (p's from .001 to .004). CONCLUSIONS: These findings point to the efficacy of MPH challenge in improving concentration and tension in adult ADHD, thus emphasizing the need for a broader treatment access for these patients.


Assuntos
Transtorno do Deficit de Atenção com Hiperatividade/tratamento farmacológico , Estimulantes do Sistema Nervoso Central/administração & dosagem , Monitoramento de Medicamentos , Metilfenidato/administração & dosagem , Adolescente , Adulto , Fatores Etários , Idoso , Transtorno do Deficit de Atenção com Hiperatividade/fisiopatologia , Estimulantes do Sistema Nervoso Central/farmacocinética , Estimulantes do Sistema Nervoso Central/farmacologia , Relação Dose-Resposta a Droga , Feminino , Humanos , Comportamento Impulsivo/efeitos dos fármacos , Masculino , Metilfenidato/farmacocinética , Metilfenidato/farmacologia , Pessoa de Meia-Idade , Adulto Jovem
16.
J Electrocardiol ; 58: 92-95, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31790855

RESUMO

PURPOSE: Electrophysiological studies and ablation procedures expose both physicians and patients to a significant amount of radiation. Most 3-D mapping systems provide improved tracking of catheters and enable radiation exposure to be reduced or even eliminated. However, there are no data on the ability of the Rhythmia ™ mapping system (Boston Scientific) to minimize fluoroscopy time and dose. METHODS: Here, we report on the feasibility and safety of a novel non-fluoroscopic approach (NFA) that uses the Rhythmia ™ mapping system and a novel navigation-enabled ablation catheter in SVT and atrial flutter procedures, and describe in detail our modified procedural work-flow. A total of 20 consecutive patients who were referred to our center for RF ablation of SVT arrhythmias were included in this analysis to test our procedural work flow. RESULTS: In our preliminary experience of the NFA work-flow, fluoroscopy times and radiological exposure were significantly reduced in comparison with the conventional approach. CONCLUSION: In our preliminary experience, arrhythmia ablation through a near-zero fluoroscopy approach involving the use of a novel ablation technology and the Rhythmia™ mapping system proved to be safe, feasible and effective in common atrial arrhythmias.


Assuntos
Flutter Atrial , Ablação por Cateter , Exposição à Radiação , Flutter Atrial/cirurgia , Eletrocardiografia , Humanos , Exposição à Radiação/prevenção & controle , Resultado do Tratamento
17.
J Electrocardiol ; 61: 147-152, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-32629315

RESUMO

BACKGROUND/AIM: Heart failure is a leading cause of morbidity and mortality worldwide and it is a major cause of emergency department access for cardiovascular disease patients. Aim of this study was to identify the electrocardiographic (ECG) markers, based on short-term temporal repolarization dispersion, capable to individuate decompensated chronic heart failure (CHF) patients at high mortality risk. METHODS: We obtained the following variables from an ECG recording, monitored via mobile phone, during 5-minute recordings in decompensated CHF patients: RR, QT end (QTe), QT peak (QTp) and T peak to T end (Te) and we calculated mean, standard deviation (SD) and normalized index (N). RESULTS: In-hospital mortality occurred for 25 subjects on 101 studied (25%). Deceased patients showed higher QTeSD (p < 0.01), Te mean (p < 0.01), TeSD (p < 0.05), QTeVN (p < 0.05) than the surviving group. Logistic multivariable analysis evidenced that Te mean was a significant predictor of in-hospital mortality (odd ratio: 0.09, 95% confidence limit: 0.02-0.35, p: 0.001). At multiple regression analysis, TeSD was significantly and positively related only to the NT-pro BNP levels (r: 0.540; p < 0.001). The Te mean (AUC: 0.677 p < 0.01) and TeSD (AUC: 0.647, p: 0.05) showed significant sensitivity/specificity for the event. CONCLUSIONS: The Te mean and TeSD seem to be a promising noninvasive clinical marker able to identify patients with decompensated CHF at high risk of in-hospital mortality.


Assuntos
Eletrocardiografia , Insuficiência Cardíaca , Biomarcadores , Mortalidade Hospitalar , Humanos , Peptídeo Natriurético Encefálico , Projetos Piloto
18.
J Electrocardiol ; 58: 19-26, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-31678717

RESUMO

BACKGROUND: Recent evidence has shown that the presence of abnormal substrate can be demonstrated also among patients with "lone" AF. OBJECTIVES: Interatrial conduction slowing is likely to characterize patients with paroxysmal atrial fibrillation (AF) and it could be correlated to the left atrium area of prolonged local bipolar endocardial electrograms. METHODS: P-wave duration (PWD), amplified PWD and endocavitary interatrial conduction time (IACT), were analyzed in 60 patients; 30 undergoing de novo ablation for paroxysmal AF with normal atrial volumes and without any other cardiac disease and 30 of similar age undergoing electrophysiological study for atrioventricular nodal reentrant tachycardia or atrioventricular re- entrant tachycardia. In patients with AF, voltage maps and local bipolar electrograms (LBE) duration map were evaluated. RESULTS: Although PWD was <120 ms in 28 patients with AF and in 29 controls, patients with AF exhibited longer PWD, amplified-PWD and IACT. Although low-voltage areas (<0.5 mV) were not found in the study population, 28 of them demonstrated areas with LBE longer than 60 ms. These LBE were found mainly in the roof of the left atrium and their extension was correlated to IACT (R = 0.51, p = 0.004). IACT >135.5 ms identified the subjects who experienced AF with 90% sensitivity and 97% specificity. CONCLUSION: A subclinical interatrial conduction disturbance is demonstrable in subjects with paroxysmal AF and normal left atrial volume. IACT has a good correlation to the areas of abnormal LBE in the left atrium. IACT >135 ms identified subjects who have experienced AF.


Assuntos
Fibrilação Atrial , Taquicardia por Reentrada no Nó Atrioventricular , Fibrilação Atrial/diagnóstico , Eletrocardiografia , Átrios do Coração/diagnóstico por imagem , Sistema de Condução Cardíaco , Humanos
19.
Cancer Cell Int ; 19: 83, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30992690

RESUMO

BACKGROUND: In addition to morphological and cytogenetic features, acute myeloid leukemias are characterized by mutations that can be used for target-therapy; also the minimal/measurable residual disease (MRD) could be an important prognostic factor. The purpose of this retrospective study was to investigate if somatic mutations could represent an additional prognostic value in respect of MRD alone. METHOD: At baseline, 98 patients were tested for NPM1, FLT3, and for WT1 expression; 31 for ASXL1, TET2, IDH1, IDH2, N-RAS, WT1, c-KIT, RUNX1, and DNMT3A. The same genes have been also tested after induction and consolidation. RESULTS: Overall, 60.2% of our patients resulted mutated: 24.5% carried mutations of FLT3-ITD, 38.7% of NPM1, 48.4% of c-KIT, 25.8% of N-RAS and 19.3% of IDH2. The probability of achieving a complete response (CR) was higher for younger patients, with low ELN risk score, NPM1-mutated, with low WT1 levels, and without FLT3. The presence of additional mutations represented a poor predictive factor: only 19% of these cases achieved CR in comparison to 43% of subjects without any of it. Concerning survival, it was conditioned by a lower ELN risk score, younger age, reduction > 1 log of the NPM1 mutational burden, disappearance of FLT3 mutations and lower WT1 expression. Regarding the role of the additional mutations, they impaired the outcome of 20% of the already MRD-negative patients. Concerning the possibility of predicting relapse, we observed an increase of the NPM1 mutational burden at the time-point immediately preceding the relapse (about 2 months earlier) in 50% of subjects. Similarly concerning WT1, an increase of its expression anticipated disease recurrence in 64% of cases. CONCLUSIONS: We demonstrated that additional somatic mutations are able to impair outcome of the already MRD-negative subjects. About MRD, we suggest a prognostic role also for the WT1 expression. Finally, we considered as relevant the assessment of NPM1 quantity clearance instead of the presence/absence of mutations alone. Still remains in doubt the utility in terms of long-term prognosis of a baseline more complex mutational screening; we could hypothesize that it would be useful for those patients where other markers are not available or who reached the MRD negativity.

20.
J Electrocardiol ; 54: 47-48, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-30893578

RESUMO

Recognition of pre-potentials during activation mapping of aortic cusp premature ventricular contractions is useful to localize the precise site of origin and is an indicator of successful ablation, but sometimes these electrograms can be blunt and have low amplitude. High resolution mapping in the aortic cusp region allows improved near field detection of these signals in very few beats.


Assuntos
Aorta Torácica/fisiopatologia , Mapeamento Potencial de Superfície Corporal/instrumentação , Complexos Ventriculares Prematuros/fisiopatologia , Eletrocardiografia , Humanos , Masculino , Pessoa de Meia-Idade
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA