Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 20 de 208
Filtrar
Mais filtros

Base de dados
País/Região como assunto
Tipo de documento
Intervalo de ano de publicação
1.
Sensors (Basel) ; 24(11)2024 Jun 04.
Artigo em Inglês | MEDLINE | ID: mdl-38894437

RESUMO

Temporomandibular disorders (TMDs) refer to a group of conditions that affect the temporomandibular joint, causing pain and dysfunction in the jaw joint and related muscles. The diagnosis of TMDs typically involves clinical assessment through operator-based physical examination, a self-reported questionnaire and imaging studies. To objectivize the measurement of TMD, this study aims at investigating the feasibility of using machine-learning algorithms fed with data gathered from low-cost and portable instruments to identify the presence of TMD in adult subjects. Through this aim, the experimental protocol involved fifty participants, equally distributed between TMD and healthy subjects, acting as a control group. The diagnosis of TMD was performed by a skilled operator through the typical clinical scale. Participants underwent a baropodometric analysis by using a pressure matrix and the evaluation of the cervical mobility through inertial sensors. Nine machine-learning algorithms belonging to support vector machine, k-nearest neighbours and decision tree algorithms were compared. The k-nearest neighbours algorithm based on cosine distance was found to be the best performing, achieving performances of 0.94, 0.94 and 0.08 for the accuracy, F1-score and G-index, respectively. These findings open the possibility of using such methodology to support the diagnosis of TMDs in clinical environments.


Assuntos
Algoritmos , Aprendizado de Máquina , Transtornos da Articulação Temporomandibular , Humanos , Transtornos da Articulação Temporomandibular/diagnóstico , Transtornos da Articulação Temporomandibular/fisiopatologia , Masculino , Feminino , Adulto , Máquina de Vetores de Suporte , Pessoa de Meia-Idade , Adulto Jovem , Árvores de Decisões
2.
Arch Orthop Trauma Surg ; 144(1): 307-313, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37612567

RESUMO

BACKGROUND: In recent years, increasing interest has arisen for medial pivoting TKA implants, designed to mimic the physiological knee kinematics, maximizing the contact area on the medial compartment of the knee, increasing anterior-posterior stability, and contributing to a ball-in-socket effect that allows the posterior cruciate sacrifice without a post-CAM mechanism. The medial congruent liner works with a J-curve cruciate-retaining (CR) femur without a real ball-in-socket design. The aim of this study was to evaluate the clinical outcomes and survival of these implants, with or without PCL sparing, at a medium follow-up. METHODS: Between October 2016 and October 2018, 165 TKRs were performed in 161 patients (69.2% females and 30.8% males) and prospectively followed. Mean follow-up was 72 ± 12 months. All surgeries were performed using an extramedullary device and the same prosthetic implant. Patients were matched in two groups: in 80 patients, the PCL was preserved; in 85 patients, the PCL was sacrificed with a reduction of the tibial slope. RESULTS: The OKS and KSS improved in both groups. The difference between the two groups at the final follow-up was not statistically significant. Good-to-excellent clinical results according to the KSS were achieved in 93% of the knees in the PCP group and in 95% in the PCS group. At final follow-up, the Forgotten Joint Score (FJS) was 73.6 in the PCP group and 74.1 in the PCS group with no statistical difference between the two groups (P > 0.05). CONCLUSIONS: TKA with a medially congruent insert, showed promising results at mid-term follow-up, PCL preservation or sacrifice did not affect the clinical outcomes and survival. Further follow-up will be needed to evaluate these results at long term.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Ligamento Cruzado Posterior , Masculino , Feminino , Humanos , Artroplastia do Joelho/métodos , Seguimentos , Sobrevivência , Amplitude de Movimento Articular/fisiologia , Articulação do Joelho , Fenômenos Biomecânicos , Osteoartrite do Joelho/cirurgia , Ligamento Cruzado Posterior/cirurgia
3.
Arch Orthop Trauma Surg ; 144(1): 393-404, 2024 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-37755480

RESUMO

BACKGROUND: Robotic-assisted total knee arthroplasty (RTKA) and navigated total knee arthroplasty (NTKA) have shown improved knee alignment and reduced radiographic outliers. Recent studies have proven that conventional mechanical alignment may not be the optimal goal for every patient. The aim of this study was to compare the accuracy of the planned implant positioning of a novel image-less robotic technique with an established navigated technique (NTKA). METHOD: The study is a retrospective analysis of prospectively collected data that compared the implant positioning and lower-limb alignment of 86 image-less RTKA with 86 image-less NTKA. Radiographic analysis was performed to evaluate the lower-limb overall alignment, femoral and tibial components positioning in the coronal and sagittal planes. Outliers were evaluated with a cutoff of ± 3°. RESULTS: No difference was noted between the two groups for radiographic outliers within ± 3° from neutral (p = 0.098). The mean hip-knee-ankle angle deviation from target was 1.3° in the RTKA group compared to 1.9° in the NTKA (p < 0.001). Femoral sagittal deviation (femoral component flexion) was smaller in the RTKA group (0.9° vs 1.9°; p < 0.001). Similarly, tibial coronal deviation (0.8° vs 1.5°; p < 0.001) and tibial sagittal deviation (tibial slope) were smaller in the RTKA group compared to the NTKA group (0.9° vs 1.7°; p < 0.001). CONCLUSIONS: The RTKA group reported a substantial and significant reduced error from the planned target angles for both tibial and femoral components. No difference in terms of radiographic outliers was noted between navigation and robotic assistance.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Procedimentos Cirúrgicos Robóticos , Cirurgia Assistida por Computador , Humanos , Artroplastia do Joelho/métodos , Estudos Retrospectivos , Cirurgia Assistida por Computador/métodos , Articulação do Joelho/cirurgia , Tíbia/cirurgia , Osteoartrite do Joelho/cirurgia
4.
Artigo em Inglês | MEDLINE | ID: mdl-38231208

RESUMO

BACKGROUND: This study aimed to assess the long-term survivorship and functional outcomes of fixed-bearing lateral unicompartmental knee arthroplasty (UKA) in a young patients' population with osteoarthritis limited to the lateral compartment. METHODS: The study included a cohort of consecutive patients who underwent lateral UKA between January 2008 and December 2014 at a single high-volume surgical center. The surgical procedures were performed by experienced surgeons using a lateral parapatellar approach and fixed-bearing implants. Patient follow-up included a retrospective re-evaluation, clinical assessments, patient-reported outcome measures (PROMs), and X-ray analysis. RESULTS: A total of 40 lateral UKAs were analyzed, with 19 performed on the left and 21 on the right knee. The mean age of the patients at the time of surgery was 57.6 years, and the mean BMI was 24.8. At the final follow-up, 80% of patients achieved excellent outcomes (OKS > 41), and 20% had good outcomes (OKS: 34-41). No patients exhibited fair or poor outcomes. The mean FJS at the final follow-up was 82.8. The mean WOMAC was 10.5. Kaplan-Meier survival analysis revealed a survivorship rate of 93.1% at 10 years, considering revision for any reason as endpoint. CONCLUSIONS: Lateral UKA proved to be an effective treatment option for osteoarthritis affecting the lateral compartment of the knee. The study demonstrated a high survivorship rate and favorable functional outcomes at a mean follow-up of 132.7 months. These findings highlight the potential benefits of fixed-bearing lateral UKA in selected patients with lateral compartment knee pathology.

5.
Pflugers Arch ; 475(6): 731-745, 2023 06.
Artigo em Inglês | MEDLINE | ID: mdl-37022463

RESUMO

The effects of excitability, refractoriness, and impulse conduction have been independently related to enhanced arrhythmias in the aged myocardium in experimental and clinical studies. However, their combined arrhythmic effects in the elderly are not yet completely understood. Hence, the aim of the present work is to relate relevant cardiac electrophysiological parameters to enhanced arrhythmia vulnerability in the in vivo senescent heart. We used multiple-lead epicardial potential mapping in control (9-month-old) and aged (24-month-old) rat hearts. Cardiac excitability and refractoriness were evaluated at numerous epicardial test sites by means of the strength-duration curve and effective refractory period, respectively. During sinus rhythm, durations of electrogram intervals and waves were prolonged in the senescent heart, compared with control, demonstrating a latency in tissue activation and recovery. During ventricular pacing, cardiac excitability, effective refractory period, and dispersion of refractoriness increased in the aged animal. This scenario was accompanied by impairment of impulse propagation. Moreover, both spontaneous and induced arrhythmias were increased in senescent cardiac tissue. Histopathological evaluation of aged heart specimens revealed connective tissue deposition and perinuclear myocytolysis in the atria, while scattered microfoci of interstitial fibrosis were mostly present in the ventricular subendocardium. This work suggests that enhanced arrhythmogenesis in the elderly is a multifactorial process due to the joint increase in excitability and dispersion of refractoriness in association with enhanced conduction inhomogeneity. The knowledge of these electrophysiological changes will possibly contribute to improved prevention of the age-associated increase in cardiac arrhythmias.


Assuntos
Arritmias Cardíacas , Sistema de Condução Cardíaco , Masculino , Ratos , Animais , Miocárdio , Ventrículos do Coração , Átrios do Coração
6.
J Clin Immunol ; 43(8): 2091-2103, 2023 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-37755605

RESUMO

Granulomatous lymphocytic interstitial lung disease (GLILD) represents a fatal immune dysregulatory complication in common variable immunodeficiency (CVID). Evidence-based diagnostic guidelines are lacking, and GLILD treatment consists in immunosuppressive drugs; nonetheless, therapeutical strategies are heterogeneous and essentially based on experts' opinions and data from small case series or case reports.We aimed to evaluate the efficacy and safety of first-line Rituximab monotherapy for CVID-related GLILD, by assessing symptoms and quality of life alterations, immunological parameters, pulmonary function tests, and lung computed tomography.All six GLILD patients received Rituximab infusions as a first-line treatment. Rituximab was administered at 375 mg/m2 monthly for six infusions followed by maintenance every 3 months; none of the patients experienced severe adverse events. Symptom burden and quality of life significantly improved in treated patients compared to a control group of CVID patients without GLILD. Rituximab treatment indirectly caused a trend toward reduced T-cell activation and exhaustion markers sCD25 and sTIM-3. Lung function improved in treated patients, with statistically significant increases in TLC and DLCO. Lung CT scan findings expressed by means of Baumann scoring system displayed a reduction in the entire cohort.In conclusion, first-line monotherapy with Rituximab displayed high efficacy in disease remission in all treated patients, with improvement of symptoms and amelioration of quality of life, as well as restoration of PFTs and lung CT scan findings.


Assuntos
Imunodeficiência de Variável Comum , Doenças Pulmonares Intersticiais , Humanos , Rituximab/uso terapêutico , Imunodeficiência de Variável Comum/complicações , Imunodeficiência de Variável Comum/diagnóstico , Imunodeficiência de Variável Comum/tratamento farmacológico , Doenças Pulmonares Intersticiais/diagnóstico , Doenças Pulmonares Intersticiais/tratamento farmacológico , Doenças Pulmonares Intersticiais/etiologia , Qualidade de Vida , Pulmão
7.
Appl Microbiol Biotechnol ; 107(19): 5975-5986, 2023 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-37552252

RESUMO

This work aims to represent a standard application for understanding the extent of the antibacterial efficacy of coatings with different amounts of colloidal silver on wooden surfaces over time. The key variable that was intended to be evaluated in this study was the "time efficiency," with concerns about the possible efficacy in the durability of the surfaces. By highlighting the "expiry date" of the agents, as in the case with other products, the study aimed to confirm the validity of the simulation tests conducted in the laboratory with degradation tests. Furthermore, the role of the silver amount on the barrier performance of the coatings was assessed by liquid resistance, water uptake, and perspiration tests, evaluating the aesthetic durability of the coatings by means of colorimetric analyses. Ultimately, this work demonstrates that these coatings may represent alternatives in terms of prolonged antimicrobial activity when compared with the biocide agents currently in use, capable to offer good resistance to detergent solutions and to water. Nevertheless, due to silver's susceptibility to extended exposure to acidic solutions, the findings of the research discourage the utilization of colloidal silver in wood paints intended for use in public settings. KEY POINTS: • Colloidal silver does not alter the deposition process and does not introduce defects in the wood paint. • Coatings containing silver show high antimicrobial activity over time, against both E.coli and S.aureus. • The silver-based filler resists contact with detergents and aqueous solutions but suffers oxidation processes in acidic environments.


Assuntos
Anti-Infecciosos , Prata , Prata/farmacologia , Madeira , Antibacterianos/farmacologia , Água , Escherichia coli , Materiais Revestidos Biocompatíveis
8.
Knee Surg Sports Traumatol Arthrosc ; 31(3): 1153-1161, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34981162

RESUMO

PURPOSE: Over the last decade, robotic TKA gained popularity for improving the accuracy of implant positioning and reducing outliers in limb alignment comparing to conventional jig-based TKA. Hypothesis of this study was that this newly designed robotically assisted system will achieve a high level of accuracy for bone resection. Purpose of the study was to evaluate the accuracy of the system. METHODS: For this study, 75 knees in 75 patients were operated using a new, robotic system (ROSA® Knee System; Zimmer Biomet, Warsaw, IN) with a Posterior Stabilized Total Knee Arthroplasty (Persona® Knee System). The planned, validated and measured angles and cuts for the distal and posterior femur, for the proximal tibia and for the final coronal alignment on long standing x-rays were compared. RESULTS: A statistically significant difference was found only between the average planned and the average validated angle for femoral flexion, tibial coronal axis, medial and lateral cuts; the average difference was in any case below 1 mm or under 1 degree with SD < 1. No statistical difference was found between planned validated and measured cuts. Average difference between planned HKA and measured was 1.2 ± 1.1. No statistically significant difference was found. CONCLUSIONS: The results of this study demonstrated that using this new surgical robot in total knee arthroplasty it is possible to perform accurate bone cuts and to achieve the planned angles and resections.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Procedimentos Cirúrgicos Robóticos , Cirurgia Assistida por Computador , Humanos , Artroplastia do Joelho/métodos , Procedimentos Cirúrgicos Robóticos/métodos , Cirurgia Assistida por Computador/métodos , Articulação do Joelho/cirurgia , Tíbia/cirurgia , Fêmur/cirurgia , Osteoartrite do Joelho/cirurgia
9.
Knee Surg Sports Traumatol Arthrosc ; 31(2): 407-412, 2023 Feb.
Artigo em Inglês | MEDLINE | ID: mdl-34596693

RESUMO

PURPOSE: Postoperative instability represents one of the most common complications following primary total knee arthroplasty (TKA). To prevent this outcome, valgus deformities have been historically treated using more constrained implants. The purpose of this study was to evaluate the outcome of treating a moderate valgus deformity by combining a surgical technique used to release the postero-lateral soft tissue envelope with the use of a medially congruent (MC) TKA design without using classical, semi-constrained inserts. METHODS: Seventy-nine MC TKAs were performed by three surgeons at three institutions between 2016 and 2018 as part of a multicenter, international study. Inclusion criteria were: radiographic late-stage osteoarthritic knees with Ranawat's type 1 or 2 classification of valgus deformity and integrity of the medial capsular-ligament complex (less than 10 mm of medial opening during valgus stress test at 10° of knee flexion). Exclusion criteria were: BMI > 40; neuromuscular, metabolic, or immunologic disorders; or the inability to complete outcome measures or radiographic assessment. RESULTS: Seventy-seven patients (79 knees), 59 males and 18 females, were evaluated at 2-year minimum follow-up according to the Knee Society Score (KSS) and Forgotten Joint Score (FJS). Mean age at surgery was 70 years (range 48-91). The mean range of motion (ROM) improved from 110° (range 85°-130°) preoperatively to 121° (range 105°-135°) (p < 0.001) at the time of the last follow-up. Preoperative knee extension significantly improved from 3° (range - 15° to 20°) to 1° (range - 5° to 5°) of flexion at the last follow-up in all the patients. KSS and KSS Functional scores were 89 (range 65-100) and 82 points (range 55-100), respectively. The FJS obtained at the last follow-up was 72 (range 49-88). Two patients (2.5%) had major postoperative complications (one periprosthetic joint infection; one postoperative patellar fracture) requiring surgical interventions. CONCLUSIONS: In different surgeon's hands, the use of a modern medially congruent TKA design yielded good clinical outcomes at 2 years in a consecutive series of TKA in valgus arthritic knees. Postoperative instability was not recorded in this series and this finding was related to the high conformity design of the MC polyethylene insert, which significantly differs from classical posterior-stabilized (PS) designs. LEVEL OF EVIDENCE: IV.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Masculino , Feminino , Humanos , Pessoa de Meia-Idade , Idoso , Idoso de 80 Anos ou mais , Artroplastia do Joelho/métodos , Articulação do Joelho/diagnóstico por imagem , Articulação do Joelho/cirurgia , Amplitude de Movimento Articular , Polietileno
10.
Artigo em Inglês | MEDLINE | ID: mdl-37236826

RESUMO

BACKGROUND: Pancreatic solid pseudopapillary tumors (SPTs) are rare clinical entity, with low malignancy and still unclear pathogenesis. They account for less than 2% of exocrine pancreatic neoplasms. This study aimed to perform a systematic review of the main clinical, surgical and oncological characteristics of pancreatic SPTs. DATA SOURCES: MEDLINE/PubMed, Web of Science and Scopus databases were systematically searched for the main clinical, surgical and oncological characteristics of pancreatic SPTs up to April 2021, in accordance with the preferred reporting items for systematic reviews and meta-analyses (PRISMA) standards. Primary endpoints were to analyze treatments and oncological outcomes. RESULTS: A total of 823 studies were recorded, 86 studies underwent full-text reviews and 28 met inclusion criteria. Overall, 1384 patients underwent pancreatic surgery. Mean age was 30 years and 1181 patients (85.3%) were female. The most common clinical presentation was non-specific abdominal pain (52.6% of cases). Mean overall survival was 98.1%. Mean recurrence rate was 2.8%. Mean follow-up was 4.2 years. CONCLUSIONS: Pancreatic SPTs are rare, and predominantly affect young women with unclear pathogenesis. Radical resection is the gold standard of treatment achieving good oncological impact and a favorable prognosis in a yearly life-long follow-up.

11.
Sensors (Basel) ; 23(11)2023 May 31.
Artigo em Inglês | MEDLINE | ID: mdl-37299975

RESUMO

Due to subjectivity in refereeing, the results of race walking are often questioned. To overcome this limitation, artificial-intelligence-based technologies have demonstrated their potential. The paper aims at presenting WARNING, an inertial-based wearable sensor integrated with a support vector machine algorithm to automatically identify race-walking faults. Two WARNING sensors were used to gather the 3D linear acceleration related to the shanks of ten expert race-walkers. Participants were asked to perform a race circuit following three race-walking conditions: legal, illegal with loss-of-contact and illegal with knee-bent. Thirteen machine learning algorithms, belonging to the decision tree, support vector machine and k-nearest neighbor categories, were evaluated. An inter-athlete training procedure was applied. Algorithm performance was evaluated in terms of overall accuracy, F1 score and G-index, as well as by computing the prediction speed. The quadratic support vector was confirmed to be the best-performing classifier, achieving an accuracy above 90% with a prediction speed of 29,000 observations/s when considering data from both shanks. A significant reduction of the performance was assessed when considering only one lower limb side. The outcomes allow us to affirm the potential of WARNING to be used as a referee assistant in race-walking competitions and during training sessions.


Assuntos
Máquina de Vetores de Suporte , Dispositivos Eletrônicos Vestíveis , Humanos , Caminhada , Algoritmos , Inteligência Artificial
12.
Sensors (Basel) ; 23(8)2023 Apr 12.
Artigo em Inglês | MEDLINE | ID: mdl-37112276

RESUMO

The importance of physical activity has been widely demonstrated both in clinics and in sports. One of the new frontier training programs is high-intensity functional training (HIFT). The immediate effects of HIFT on the psychomotor and cognitive performance of well-trained people are still not clear. This paper aims to evaluate the immediate effects induced by HIFT on blood lactate levels, physical performance in terms of body stability and jump ability, and cognitive performance in terms of reaction time. Nineteen well-trained participants were enrolled in the experimental studies and asked to execute six repetitions of a circuit training. Data were gathered both in a pre-training session and after each one of the circuit repetitions. An immediate significant increase with respect to the baseline was observed during the first repetition, with a further increase after the third one. No effects on jump ability were found, whereas a deterioration in body stability was found. Positive immediate effects on cognitive performance in terms of accuracy and speed in task execution were assessed. The findings can be exploited by trainers during coaching to optimize the design of training programs.


Assuntos
Treinamento Intervalado de Alta Intensidade , Esportes , Humanos , Adulto , Exercício Físico , Cognição
13.
Int Orthop ; 47(3): 755-762, 2023 03.
Artigo em Inglês | MEDLINE | ID: mdl-36596998

RESUMO

PURPOSE: Higher patient's expectations and dissatisfaction following total knee arthroplasty are well-documented phenomena. Despite the implications of different patients' related factors both modifiable and nonmodifiable, in the last decade a lot of emphasis has been focused on surgical technique, implant alignment and stability both as a cause and a potential solution of several problems. METHODS: Different alignment and balancing techniques have been recently described and the introduction of new technologies such as computer and robotic-assisted surgery have been the basis for their optimization. In this paper, the surgical technique of the ROSA Knee System will be described focusing on the potential alignment options and the ligament balancing technique. The current literature available about the system will also be analyzed. RESULTS: The ROSA® robotic system have been recently introduced in the market and presents specific and peculiar features to optimize ligament balancing and an individualized alignment of the implant in a three dimensional prospective. DISCUSSION: The system is showing a favourable gap balancing technique and the possibility to create an individualized alignment. Preliminary results have now been shown in the literature both on the accuracy of the system and on clinical outcomes. CONCLUSIONS: Preliminary results are promising both in terms of accuracy of the system and of clinical outcomes.


Assuntos
Artroplastia do Joelho , Osteoartrite do Joelho , Procedimentos Cirúrgicos Robóticos , Rosa , Humanos , Artroplastia do Joelho/efeitos adversos , Artroplastia do Joelho/métodos , Procedimentos Cirúrgicos Robóticos/efeitos adversos , Procedimentos Cirúrgicos Robóticos/métodos , Estudos Prospectivos , Articulação do Joelho/cirurgia , Osteoartrite do Joelho/cirurgia , Ligamentos/cirurgia
14.
Int J Mol Sci ; 24(3)2023 Jan 25.
Artigo em Inglês | MEDLINE | ID: mdl-36768684

RESUMO

Frequently touched surfaces (FTS) that are contaminated with pathogens are one of the main sources of nosocomial infections, which commonly include hospital-acquired and healthcare-associated infections (HAIs). HAIs are considered the most common adverse event that has a significant burden on the public's health worldwide currently. The persistence of pathogens on contaminated surfaces and the transmission of multi-drug resistant (MDR) pathogens by way of healthcare surfaces, which are frequently touched by healthcare workers, visitors, and patients increase the risk of acquiring infectious agents in hospital environments. Moreover, not only in hospitals but also in high-traffic public places, FTS play a major role in the spreading of pathogens. Consequently, attention has been devoted to developing novel and alternative methods to tackle this problem. This study planned to produce and characterize innovative functionalized enameled coated surfaces supplemented with 1% AgNO3 and 2% AgNO3. Thus, the antimicrobial properties of the enamels against relevant nosocomial pathogens including the Gram-positive Staphylococcus aureus and the Gram-negative Escherichia coli and the yeast Candida albicans were assessed using the ISO:22196:2011 norm.


Assuntos
Anti-Infecciosos , Infecção Hospitalar , Humanos , Antifúngicos/farmacologia , Prata/farmacologia , Anti-Infecciosos/farmacologia , Antibacterianos/farmacologia , Infecção Hospitalar/prevenção & controle , Infecção Hospitalar/microbiologia , Testes de Sensibilidade Microbiana
15.
Int J Mol Sci ; 24(7)2023 Apr 01.
Artigo em Inglês | MEDLINE | ID: mdl-37047568

RESUMO

The toxicity of nanoparticles absorbed through contact or inhalation is one of the major concerns for public health. It is mandatory to continually evaluate the toxicity of nanomaterials. In vitro nanotoxicological studies are conventionally limited by the two dimensions. Although 3D bioprinting has been recently adopted for three-dimensional culture in the context of drug release and tissue regeneration, little is known regarding its use for nanotoxicology investigation. Therefore, aiming to simulate the exposure of lung cells to nanoparticles, we developed organoid-based scaffolds for long-term studies in immortalized cell lines. We printed the viscous cell-laden material via a customized 3D bioprinter and subsequently exposed the scaffold to either 40 nm latex-fluorescent or 11-14 nm silver nanoparticles. The number of cells significantly increased on the 14th day in the 3D environment, from 5 × 105 to 1.27 × 106, showing a 91% lipid peroxidation reduction over time and minimal cell death observed throughout 21 days. Administered fluorescent nanoparticles can diffuse throughout the 3D-printed scaffolds while this was not the case for the unprinted ones. A significant increment in cell viability from 3D vs. 2D cultures exposed to silver nanoparticles has been demonstrated. This shows toxicology responses that recapitulate in vivo experiments, such as inhaled silver nanoparticles. The results open a new perspective in 3D protocols for nanotoxicology investigation supporting 3Rs.


Assuntos
Bioimpressão , Nanopartículas Metálicas , Alicerces Teciduais , Bioimpressão/métodos , Nanopartículas Metálicas/toxicidade , Prata/toxicidade , Organoides , Impressão Tridimensional , Engenharia Tecidual/métodos
16.
Arch Orthop Trauma Surg ; 143(5): 2675-2681, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35819516

RESUMO

BACKGROUND: Total knee arthroplasty (TKA) in major deformities with ligament insufficiency may require a higher constraint, with bone sacrifice and concerns about long-term survivorship. Mid-level constraint liners have been recently introduced, but few studies described their outcomes. The aim of this study is to evaluate the short to mid-term outcomes of a constrained postero-stabilized (CPS) insert for primary TKA in moderate to severe deformities. METHODS: All patients who underwent TKA using a CPS liner in two centers between 2015 and 2017 were included in the study. The indications were: (1) valgus deformity type 2-3 partially correctable; (2) severe varus deformity with varus thrust; (3) post-traumatic deformity with major ligamentous insufficiency and any case of intra-operative ligament insufficiency. Patients were evaluated according to the Knee Society Scoring System (KSS), the Hospital for Special Surgery score (HSS), the Western Ontario and Mc Master University (WOMAC) and the Oxford Knee score (OKS). X-rays were evaluated according to the Knee Society Roentgenographic Evaluation System. RESULTS: Forty-seven TKA were included, with an average age of 66.1 ± 10.3 years and an average follow-up of 68.4 ± 6 months. All patients demonstrated a moderate to severe pre-operative mediolateral instability. All the scores significantly improved (p < 0.0001). In 71.4% of cases, the outcomes were excellent or very good. There were no failures due to aseptic loosening but one failure due to a traumatic ligament rupture. The cumulative survivorship was 97.9% ± 2.1% at 84 months. CONCLUSIONS: This mid-range constraint total knee replacement demonstrated promising outcomes and survival at mid-term follow-up. LEVEL OF EVIDENCE: IV (case series).


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Humanos , Pessoa de Meia-Idade , Idoso , Artroplastia do Joelho/métodos , Seguimentos , Articulação do Joelho/cirurgia , Ligamentos/cirurgia , Estudos Retrospectivos , Amplitude de Movimento Articular
17.
Arch Orthop Trauma Surg ; 143(5): 2693-2699, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35908099

RESUMO

BACKGROUND: Unicompartmental knee arthroplasty (UKA) accounts for 10% of knee arthroplasty procedures in Europe. Fixed bearing UKA designs have shown favorable survivorship in registries when compared with mobile bearings. This study analyses long-term follow-up of patients with a medial fixed bearing metal backed tibial UKA and reports 15 years survivorship and clinical outcomes. METHODS: Data were collected prospectively for 148 medial unicompartmental fixed bearing metal backed UKAs implanted in 148 patients in two high volumes knee arthroplasty centers between January 2005 and December 2007. The indication was osteoarthritis in all but 2 patients. Patients' reported outcome scores were documented at last follow up. The mean patient age at time of surgery was 65 years. RESULTS: At final follow up, outcome and survivorship data were collected for 124 medial fixed bearing UKAs. Thirteen patients underwent revision; average time to revision was 77 months (SD 35.31). The Kaplan-Meier analysis demonstrated a survivorship of 97.65% at 69 months and of 89,52%. at 120 months and 173 months of follow-up. When revisions for infection were excluded, the survivorship of the implant was 90.3% at the last of follow up. The mean OKS was 43.02 (SD 5.1) at the last follow-up, and the mean FJS was 77.6 (SD 6.9). CONCLUSION: This Medial fixed bearing metal backed UKA demonstrates promising long-term survivorship and patient outcomes. It appears to be a suitable and reasonably lasting option for the treatment of medial compartment OA.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Humanos , Idoso , Artroplastia do Joelho/métodos , Sobrevivência , Osteoartrite do Joelho/cirurgia , Reoperação , Resultado do Tratamento , Seguimentos , Articulação do Joelho/cirurgia , Estudos Retrospectivos
18.
Arch Orthop Trauma Surg ; 143(5): 2701-2711, 2023 May.
Artigo em Inglês | MEDLINE | ID: mdl-35913518

RESUMO

BACKGROUND: Robotic assisted total knee arthroplasty (RTKA) has shown improved knee alignment and reduced radiographic outliers. However, there remains debate on functional outcomes and patient-reported outcomes (PROMs). This study compares the 1-year clinical outcomes of a new imageless robotically assisted technique (ROSA Knee System, Zimmer Biomet, Warsaw, IN) with an imageless navigated procedure (NTKA, iAssist Knee, Zimmer, Warsaw, IN). METHODS: The study is a retrospective analysis of prospectively collected data that compared the functional outcomes and PROMs of 50 imageless RTKA with 47 imageless NTKA at 1-year follow-up. Baseline characteristics, intraoperative and postoperative information were collected including complications, revisions, Knee Society Score (KSS), Knee injury and Osteoarthritis Outcome Score (KOOS) score, and Forgotten Joint Score (FJS-12). Radiographic analysis of preoperative and postoperative images evaluating hip-knee-ankle (HKA) angle was performed. RESULTS: There was no difference regarding baseline characteristics between the groups. Mean operative time was significantly longer in the RTKA group (122 min vs. 97 min; p < 0.0001). Significant differences were reported for the "Pain" (85 [RTKA] vs 79.1 [NTKA]; p = 0.0283) subsection of the KOOS score. In addition, RTKA was associated with higher maximum range of motion (119.4° vs. 107.1°; p < 0.0001) and better mean improvement of the arc of motion by 11.67° (23.02° vs. 11.36°; p < 0.0001). No significant differences were noted for other subsections of KOOS, KSS, FJS-12, complications, or limb alignment at 1-year follow-up. CONCLUSIONS: Imageless RTKA was associated with longer surgical time, better pain perception and improved ROM at 12-month follow-up compared with NTKA. No significant differences were reported on other PROMs, complication rates and radiographic outcomes. LEVEL OF EVIDENCE: III.


Assuntos
Artroplastia do Joelho , Prótese do Joelho , Osteoartrite do Joelho , Procedimentos Cirúrgicos Robóticos , Humanos , Artroplastia do Joelho/métodos , Estudos Retrospectivos , Articulação do Joelho/cirurgia , Joelho/cirurgia , Osteoartrite do Joelho/cirurgia
19.
Clin Immunol ; 237: 108974, 2022 04.
Artigo em Inglês | MEDLINE | ID: mdl-35278713

RESUMO

Dedicator of Cytokinesis 8 (DOCK8) deficiency is a rare form of autosomal recessive combined immunodeficiency. The effect of DOCK8 deficiency on Natural Killer cell biology has not been fully elucidated yet. Thus, we undertook a detailed phenotypic and functional evaluation of NK cells from seven patients with DOCK8 deficiency. Patients' immature CD56bright NK cells were defective in IFN-γ secretion, while their mature CD56dim NK cells showed impaired cytotoxicity, partially rescued upon rIL-2 addition. Cross-linking of NK cell receptors revealed a specific defect in the CD3 zeta chain-dependent activation pathway in DOCK8 deficiency. Lack of DOCK8, but not of WASP, impaired CCR7 expression on human CD56bright NK cells, a critical receptor for their migration to secondary lymph nodes. Evaluation of a patient's lymph node showed a severe reduction in NK cells that showed increased intracellular expression of CCR7. Our data suggest that DOCK8 deficiency variably affects NK cell homeostasis in humans.


Assuntos
Citocinese , Fatores de Troca do Nucleotídeo Guanina , Células Matadoras Naturais , Receptores CCR7 , Antígeno CD56/metabolismo , Fatores de Troca do Nucleotídeo Guanina/genética , Fatores de Troca do Nucleotídeo Guanina/metabolismo , Humanos , Células Matadoras Naturais/metabolismo , Receptores CCR7/genética , Receptores CCR7/metabolismo , Proteína da Síndrome de Wiskott-Aldrich
20.
Clin Immunol ; 241: 109077, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35843508

RESUMO

INTRODUCTION: Autoimmunity is a common feature in CVID patients. To date the mechanisms leading to the development of such complications are not fully elucidated. MATERIALS AND METHODS: Data from 122 CVID patients subdivided in three groups based on the absence of autoimmunity (n-AI) or the presence of hematologic autoimmune phenomena (Cy-AI) or non-hematologic autoimmune phenomena (n-Cy-AI) were evaluated. RESULTS: We identified a total of 128 autoimmune manifestations in 55/122 patients (45.1%). 30/122 (24.6%) patients presented hematologic autoimmune phenomena while 29/122 (23.8%) presented gastrointestinal autoimmune involvement. Immune thrombocytopenia was the most common manifestation (27/122; 22.1%), followed by autoimmune hemolytic anemia (18/122; 14.8%) and autoimmune enteropathy (17/122; 13.9%). Cy-AI patients displayed higher CD4+ effector memory and terminally differentiated CD8+ cells with lower percentages of naïve and recent thymic emigrants (RTEs) CD4+ cells and a significant expansion of the CD19hiCD21low population. CONCLUSIONS: CVID patients developing autoimmune cytopenias display characteristic immune phenotypic features.


Assuntos
Imunodeficiência de Variável Comum , Púrpura Trombocitopênica Idiopática , Autoimunidade , Linfócitos T CD4-Positivos , Humanos , Imunofenotipagem
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA