Pediatr Res ; 91(7): 1686-1694, 2022 06.
Artigo em Inglês | MEDLINE | ID: mdl-34294868

RESUMO

BACKGROUND: Preterm infants are commonly supported with 4-8 cm H2O continuous positive airway pressures (CPAP), although higher CPAP levels may improve functional residual capacity (FRC). METHODS: Preterm rabbits delivered at 29/32 days (~26-28 weeks human) gestation received 0, 5, 8, 12, 15 cm H2O of CPAP or variable CPAP of 15 to 5 or 15 to 8 cm H2O (decreasing ~2 cm H2O/min) for up to 10 min after birth. RESULTS: FRC was lower in the 0 (6.8 (1.0-11.2) mL/kg) and 5 (10.1 (1.1-16.8) mL/kg) compared to the 15 (18.8 (10.9-22.4) mL/kg) cm H2O groups (p = 0.003). Fewer kittens achieved FRC > 15 mL/kg in the 0 (20%), compared to 8 (36%), 12 (60%) and 15 (73%) cm H2O groups (p = 0.008). While breathing rates were not different (p = 0.096), apnoea tended to occur more often with CPAP < 8 cm H2O (p = 0.185). CPAP belly and lung bulging rates were similar whereas pneumothoraces were rare. Lowering CPAP from 15 to 5, but not 15 to 8 cm H2O, decreased FRC and breathing rates. CONCLUSION: In all, 15 cm H2O of CPAP improved lung aeration and reduced apnoea, but did not increase the risk of lung over-expansion, pneumothorax or CPAP belly immediately after birth. FRC and breathing rates were maintained when CPAP was decreased to 8 cm H2O. IMPACT: Although preterm infants are commonly supported with 4-8 cm H2O CPAP at birth, preclinical studies have shown that higher PEEP levels improve lung aeration. In this study, CPAP levels of 15 cm H2O improved lung aeration and reduced apnoea in preterm rabbit kittens immediately after birth. In all, 15 cm H2O CPAP did not increase the risk of lung over-expansion (indicated by bulging between the ribs), pneumothorax, or CPAP belly. These results can be used when designing future studies on CPAP strategies for preterm infants in the delivery room.


Assuntos
Apneia , Pneumotórax , Animais , Pressão Positiva Contínua nas Vias Aéreas , Capacidade Residual Funcional , Humanos , Recém-Nascido , Recém-Nascido Prematuro , Coelhos
2.
Opt Express ; 28(5): 7080-7094, 2020 Mar 02.
Artigo em Inglês | MEDLINE | ID: mdl-32225943

RESUMO

This work demonstrates the use of a scientific-CMOS (sCMOS) energy-integrating detector as a photon-counting detector, thereby eliminating dark current and read-out noise issues, that simultaneously provides both energy resolution and sub-pixel spatial resolution for X-ray imaging. These capabilities are obtained by analyzing visible light photon clouds that result when X-ray photons produce fluorescence from a scintillator in front of the visible light sensor. Using low-fluence monochromatic X-ray projections to avoid overlapping photon clouds, the centroid of individual X-ray photon interactions was identified. This enabled a tripling of the spatial resolution of the detector to 6.71 ± 0.04 µm. By calculating the total charge deposited by this interaction, an energy resolution of 61.2 ± 0.1% at 17 keV was obtained. When combined with propagation-based phase contrast imaging and phase retrieval, a signal-to-noise ratio of up to 15 ± 3 was achieved for an X-ray fluence of less than 3 photons/mm2.

3.
Opt Express ; 27(10): 14231-14245, 2019 May 13.
Artigo em Inglês | MEDLINE | ID: mdl-31163875

RESUMO

We present a pixel-specific, measurement-driven correction that effectively reduces errors in detector response that give rise to the ring artifacts commonly seen in X-ray computed tomography (CT) scans. This correction is easy to implement, suppresses CT artifacts significantly, and is effective enough for use with both absorption and phase contrast imaging. It can be used as a standalone correction or in conjunction with existing ring artifact removal algorithms to further improve image quality. We validate this method using two X-ray CT data sets acquired using monochromatic sources, showing post-correction signal-to-noise increases of up to 55%, and we define an image quality metric to use specifically for the assessment of ring artifact suppression.


Assuntos
Artefatos , Imagens de Fantasmas , Intensificação de Imagem Radiográfica/métodos , Interpretação de Imagem Radiográfica Assistida por Computador/métodos , Tomografia Computadorizada por Raios X/instrumentação , Algoritmos
4.
Opt Express ; 25(19): 23424-23436, 2017 Sep 18.
Artigo em Inglês | MEDLINE | ID: mdl-29041643

RESUMO

Scanning X-ray fluorescence tomography was once considered impractical due to prohibitive measurement time requirements but is now common for investigating metal distributions within small systems. A recent look-ahead to the possibilities of 4th-generation synchrotron light sources [J. Synchrotron. Radiat. 21, 1031 (2014)] raised the possibility of a spiral-scanning measurement scheme where motion overheads are almost completely eliminated. Here we demonstrate the spiral scanning measurement and use Fourier ring correlation analysis to interrogate sources of resolution degradation. We develop an extension to the Fourier ring correlation formalism that enables direct determination of resolution from the measured sinogram data, greatly enhancing its power as a diagnostic tool for computed tomography.

5.
J Synchrotron Radiat ; 22(2): 354-65, 2015 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-25723937

RESUMO

A Geant4 Monte Carlo simulation of the X-ray fluorescence microprobe (XFM) end-station at the Australian Synchrotron has been developed. The simulation is required for optimization of the scan configuration and reconstruction algorithms. As part of the simulation process, a Gaussian beam model was developed. Experimental validation of this simulation has tested the efficacy for use of the low-energy physics models in Geant4 for this synchrotron-based technique. The observed spectral distributions calculated in the 384 pixel Maia detector, positioned in the standard back-scatter configuration, were compared with those obtained from experiments performed at three incident X-ray beam energies: 18.5, 11.0 and 6.8 keV. The reduced χ-squared (\chi^{2}_{\rm{red}}) was calculated for the scatter and fluorescence regions of the spectra and demonstrates that the simulations successfully reproduce the scatter distributions. Discrepancies were shown to occur in the multiple-scatter tail of the Compton continuum. The model was shown to be particularly sensitive to the impurities present in the beryllium window of the Maia detector and their concentrations were optimized to improve the \chi^{2}_{\rm{red}} parametrization in the low-energy fluorescence regions of the spectra.

6.
Sci Rep ; 12(1): 18469, 2022 11 02.
Artigo em Inglês | MEDLINE | ID: mdl-36323686

RESUMO

The ill-posed problem of phase retrieval in optics, using one or more intensity measurements, has a multitude of applications using electromagnetic or matter waves. Many phase retrieval algorithms are computed on pixel arrays using discrete Fourier transforms due to their high computational efficiency. However, the mathematics underpinning these algorithms is typically formulated using continuous mathematics, which can result in a loss of spatial resolution in the reconstructed images. Herein we investigate how phase retrieval algorithms for propagation-based phase-contrast X-ray imaging can be rederived using discrete mathematics and result in more precise retrieval for single- and multi-material objects and for spectral image decomposition. We validate this theory through experimental measurements of spatial resolution using computed tomography (CT) reconstructions of plastic phantoms and biological tissues, using detectors with a range of imaging system point spread functions (PSFs). We demonstrate that if the PSF substantially suppresses high spatial frequencies, the potential improvement from utilising the discrete derivation is limited. However, with detectors characterised by a single pixel PSF (e.g. direct, photon-counting X-ray detectors), a significant improvement in spatial resolution can be obtained, demonstrated here at up to 17%.


Assuntos
Algoritmos , Tomografia Computadorizada por Raios X , Imagens de Fantasmas , Tomografia Computadorizada por Raios X/métodos , Fótons , Matemática
7.
IEEE Trans Med Imaging ; 41(8): 2170-2179, 2022 08.
Artigo em Inglês | MEDLINE | ID: mdl-35259098

RESUMO

In X-ray imaging, photons are transmitted through and absorbed by the target object, but are also scattered in significant quantities. Previous attempts to use scattered X-ray photons for imaging applications used pencil or fan beam illumination. Here we present 3D X-ray Scatter Tomography using full-field illumination for small-animal imaging. Synchrotron imaging experiments were performed on a phantom and the chest of a juvenile rat. Transmitted and scattered photons were simultaneously imaged with separate cameras; a scientific camera directly downstream of the sample stage, and a pixelated detector with a pinhole imaging system placed at 45° to the beam axis. We obtained scatter tomogram feature fidelity sufficient for segmentation of the lungs and major airways in the rat. The image contrast in the scatter tomogram slices approached that of transmission imaging, indicating robustness to the amount of multiple scattering present in our case. This opens the possibility of augmenting full-field 2D imaging systems with additional scatter detectors to obtain complementary modes or to improve the fidelity of existing images without additional dose, potentially leading to single-shot or reduced-angle tomography or overall dose reduction for live animal studies.


Assuntos
Fótons , Tomografia Computadorizada por Raios X , Animais , Imagens de Fantasmas , Ratos , Espalhamento de Radiação , Tomografia Computadorizada por Raios X/métodos , Raios X
8.
Phys Rev Lett ; 105(22): 220402, 2010 Nov 26.
Artigo em Inglês | MEDLINE | ID: mdl-21231368

RESUMO

We describe a wave function engineering approach to the formation of textures in nonrotated multicomponent Bose-Einstein condensates. With numerical simulations of a viable two-component condensate experiment, we demonstrate the formation of a ballistically expanding regular lattice texture, composed of half-quantum vortices and spin-2 textures. The formation is described by a linear interference process in which the geometry and phase of three initially separated wave packets provide deterministic control over the resulting lattice texture.

9.
Front Pediatr ; 7: 427, 2019.
Artigo em Inglês | MEDLINE | ID: mdl-31696099

RESUMO

Background: Spontaneous breathing is essential for successful non-invasive respiratory support delivered by a facemask at birth. As hypoxia is a potent inhibitor of spontaneous breathing, initiating respiratory support with a high fraction of inspired O2 may reduce the risk of hypoxia and increase respiratory effort at birth. Methods: Preterm rabbit kittens (29 days gestation, term ~32 days) were delivered and randomized to receive continuous positive airway pressure with either 21% (n = 12) or 100% O2 (n = 8) via a facemask. If apnea occurred, intermittent positive pressure ventilation (iPPV) was applied with either 21% or 100% O2 in kittens who started in 21% O2, and remained at 100% O2 for kittens who started the experiment in 100% O2. Respiratory rate (breaths per minute, bpm) and variability in inter-breath interval (%) were measured from esophageal pressure recordings and functional residual capacity (FRC) was measured from synchrotron phase-contrast X-ray images. Results: Initially, kittens receiving 21% O2 had a significantly lower respiratory rate and higher variability in inter-breath interval, indicating a less stable breathing pattern than kittens starting in 100% O2 [median (IQR) respiratory rate: 16 (4-28) vs. 38 (29-46) bpm, p = 0.001; variability in inter-breath interval: 33.3% (17.2-50.1%) vs. 27.5% (18.6-36.3%), p = 0.009]. Apnea that required iPPV, was more frequently observed in kittens in whom resuscitation was started with 21% compared to 100% O2 (11/12 vs. 1/8, p = 0.001). After recovering from apnea, respiratory rate was significantly lower and variability in inter-breath interval was significantly higher in kittens who received iPPV with 21% compared to 100% O2. FRC was not different between study groups at both timepoints. Conclusion: Initiating resuscitation with 100% O2 resulted in increased respiratory activity and stability, thereby reducing the risk of apnea and need for iPPV after birth. Further studies in human preterm infants are mandatory to confirm the benefit of this approach in terms of oxygenation. In addition, the ability to avoid hyperoxia after initiation of resuscitation with 100% oxygen, using a titration protocol based on oxygen saturation, needs to be clarified.

10.
Artigo em Inglês | MEDLINE | ID: mdl-30106727

RESUMO

We propose a sparse imaging methodology called Chaotic Sensing (ChaoS) that enables the use of limited yet deterministic linear measurements through fractal sampling. A novel fractal in the discrete Fourier transform is introduced that always results in the artefacts being turbulent in nature. These chaotic artefacts have characteristics that are image independent, facilitating their removal through dampening (via image denoising) and obtaining the maximum likelihood solution. In contrast with existing methods, such as compressed sensing, the fractal sampling is based on digital periodic lines that form the basis of discrete projected views of the image without requiring additional transform domains. This allows the creation of finite iterative reconstruction schemes in recovering an image from its fractal sampling that is also new to discrete tomography. As a result, ChaoS supports linear measurement and optimisation strategies, while remaining capable of recovering a theoretically exact representation of the image. We apply the method to simulated and experimental limited magnetic resonance (MR) imaging data, where restrictions imposed by MR physics typically favour linear measurements for reducing acquisition time.

11.
Phys Rev E Stat Nonlin Soft Matter Phys ; 75(6 Pt 2): 066613, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17677382

RESUMO

An analysis is presented of the phase vortices generated in the far field by an arbitrary arrangement of three monochromatic point sources of complex spherical waves. In contrast with the case of three interfering plane waves, in which an infinitely extended vortex lattice is generated, the spherical sources generate a finite number of phase vortices. Analytical expressions for the vortex core locations are developed and shown to have a convenient representation in a discrete parameter space. Our far-field analysis may be mapped onto the case of a coherently illuminated Young's interferometer, in which the screen is punctured by three rather than two pinholes.

12.
Ultramicroscopy ; 111(11): 1540-6, 2011 Nov.
Artigo em Inglês | MEDLINE | ID: mdl-21939618

RESUMO

We study atomic-resolution annular electron energy-loss spectroscopy (AEELS) in scanning transmission electron microscopy (STEM) imaging with experiments and numerical simulations. In this technique the central part of the bright field disk is blocked by a beam stop, forming an annular entry aperture to the spectrometer. The EELS signal thus arises only from electrons scattered inelastically to angles defined by the aperture. It will be shown that this method is more robust than conventional EELS imaging to variations in specimen thickness and can also provide higher spatial resolution. This raises the possibility of lattice resolution imaging of lighter elements or ionization edges previously considered unsuitable for EELS imaging.