Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 6 de 6
Filtrar
1.
Nat Biotechnol ; 24(9): 1115-22, 2006 Sep.
Artigo em Inglês | MEDLINE | ID: mdl-16964225

RESUMO

We have evaluated the performance characteristics of three quantitative gene expression technologies and correlated their expression measurements to those of five commercial microarray platforms, based on the MicroArray Quality Control (MAQC) data set. The limit of detection, assay range, precision, accuracy and fold-change correlations were assessed for 997 TaqMan Gene Expression Assays, 205 Standardized RT (Sta)RT-PCR assays and 244 QuantiGene assays. TaqMan is a registered trademark of Roche Molecular Systems, Inc. We observed high correlation between quantitative gene expression values and microarray platform results and found few discordant measurements among all platforms. The main cause of variability was differences in probe sequence and thus target location. A second source of variability was the limited and variable sensitivity of the different microarray platforms for detecting weakly expressed genes, which affected interplatform and intersite reproducibility of differentially expressed genes. From this analysis, we conclude that the MAQC microarray data set has been validated by alternative quantitative gene expression platforms thus supporting the use of microarray platforms for the quantitative characterization of gene expression.


Assuntos
Perfilação da Expressão Gênica/instrumentação , Análise de Sequência com Séries de Oligonucleotídeos/instrumentação , Garantia da Qualidade dos Cuidados de Saúde/métodos , Desenho de Equipamento , Análise de Falha de Equipamento , Perfilação da Expressão Gênica/métodos , Análise de Sequência com Séries de Oligonucleotídeos/métodos , Reprodutibilidade dos Testes , Sensibilidade e Especificidade
2.
Mol Neuropsychiatry ; 3(4): 197-213, 2018 May.
Artigo em Inglês | MEDLINE | ID: mdl-29888231

RESUMO

This study developed potential blood-based biomarker tests for diagnosing and differentiating schizophrenia (SZ), bipolar disorder type I (BD), and normal control (NC) subjects using mRNA gene expression signatures. A total of 90 subjects (n = 30 each for the three groups of subjects) provided blood samples at two visits. The Affymetrix exon microarray was used to profile the expression of over 1.4 million probesets. We selected potential biomarker panels using the temporal stability of the probesets and also back-tested them at two different visits for each subject. The 18-gene biomarker panels, using logistic regression modeling, correctly differentiated the three groups of subjects with high accuracy across the two different clinical visits (83-88% accuracy). The results are also consistent with the actual data and the "leave-one-out" analyses, indicating that the models should be predictive when applied to independent data cohorts. Many of the SZ and BD subjects were taking antipsychotic and mood stabilizer medications at the time of blood draw, raising the possibility that these drugs could have affected some of the differential transcription signatures. Using an independent Illumina data set of gene expression data from antipsychotic medication-free SZ subjects, the 18-gene biomarker panels produced a receiver operating characteristic curve accuracy greater than 0.866 in patients that were less than 30 years of age and medication free. We confirmed select transcripts by quantitative PCR and the nCounter® System. The episodic nature of psychiatric disorders might lead to highly variable results depending on when blood is collected in relation to the severity of the disease/symptoms. We have found stable trait gene panel markers for lifelong psychiatric disorders that may have diagnostic utility in younger undiagnosed subjects where there is a critical unmet need. The study requires replication in subjects for ultimate proof of the utility of the differential diagnosis.

3.
J Pediatr Pharmacol Ther ; 15(4): 274-81, 2010 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22477815

RESUMO

OBJECTIVE: Medication errors involving intravenous medications continue to be a significant problem, particularly in the pediatric population due to the high rate of point-of-care and weight-adjusted dosing. The pharmaceutical algorithm computerized calculator (pac2) assists in converting physician medication orders to correct volumes and rates of administration for intravenous medications. This study was designed to assess the efficacy of the pac2 in simulated clinical scenarios of point-of-care dosing. METHODS: The study design was a within-subject controlled study in which 33 nurses from pediatrics, pediatric critical care, or critical care (mean nursing experience of 10.9 years) carried out various point-of-care medication-dosing scenarios with and without the aid of the pac2. RESULTS: Use of the pac2 resulted in a significantly higher percentage (mean [95% CI]) of medication volumes calculated and drawn accurately (91% [87-95%] versus 61% [52-70%], p<0.0001), a higher percentage of correct recall of essential medication information (97% [95-99%] versus 45% [36-53%], p<0.0001), and better recognition of unsafe doses (93% [87-99%] versus 19% [12-27%], p<0.0001) as compared to usual practice. The pac2 also significantly reduced average medication calculation times (1.5 minutes [1.3-1.7 minutes] versus 1.9 minutes [1.6-2.2 minutes], p=0.0028) as compared to usual practice. CONCLUSIONS: The pac2 significantly improved the performance of drug calculations by pediatric and critical care nurses during simulated clinical scenarios designed to mimic point-of-care dosing. These results suggest that the pac2 addresses an area of safety vulnerability for point-of-care dosing practices and could be a useful addition to a hospital's overall program to minimize medication errors.

4.
Lancet Neurol ; 9(4): 373-80, 2010 Apr.
Artigo em Inglês | MEDLINE | ID: mdl-20206581

RESUMO

BACKGROUND: Preliminary work suggests that single-pulse transcranial magnetic stimulation (sTMS) could be effective as a treatment for migraine. We aimed to assess the efficacy and safety of a new portable sTMS device for acute treatment of migraine with aura. METHODS: We undertook a randomised, double-blind, parallel-group, two-phase, sham-controlled study at 18 centres in the USA. 267 adults aged 18-68 years were enrolled into phase one. All individuals had to meet international criteria for migraine with aura, with visual aura preceding at least 30% of migraines followed by moderate or severe headache in more than 90% of those attacks. 66 patients dropped out during phase one. In phase two, 201 individuals were randomly allocated by computer to either sham stimulation (n=99) or sTMS (n=102). We instructed participants to treat up to three attacks over 3 months while experiencing aura. The primary outcome was pain-free response 2 h after the first attack, and co-primary outcomes were non-inferiority at 2 h for nausea, photophobia, and phonophobia. Analyses were modified intention to treat and per protocol. This trial is registered with ClinicalTrials.gov, number NCT00449540. FINDINGS: 37 patients did not treat a migraine attack and were excluded from outcome analyses. 164 patients treated at least one attack with sTMS (n=82) or sham stimulation (n=82; modified intention-to-treat analysis set). Pain-free response rates after 2 h were significantly higher with sTMS (32/82 [39%]) than with sham stimulation (18/82 [22%]), for a therapeutic gain of 17% (95% CI 3-31%; p=0.0179). Sustained pain-free response rates significantly favoured sTMS at 24 h and 48 h post-treatment. Non-inferiority was shown for nausea, photophobia, and phonophobia. No device-related serious adverse events were recorded, and incidence and severity of adverse events were similar between sTMS and sham groups. INTERPRETATION: Early treatment of migraine with aura by sTMS resulted in increased freedom from pain at 2 h compared with sham stimulation, and absence of pain was sustained 24 h and 48 h after treatment. sTMS could be a promising acute treatment for some patients with migraine with aura. FUNDING: Neuralieve.


Assuntos
Enxaqueca com Aura/terapia , Estimulação Magnética Transcraniana/métodos , Adolescente , Adulto , Idoso , Método Duplo-Cego , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Manejo da Dor , Fatores de Tempo , Estimulação Magnética Transcraniana/efeitos adversos , Resultado do Tratamento , Estados Unidos , Percepção Visual , Adulto Jovem
5.
Cancer Res ; 69(22): 8629-35, 2009 Nov 15.
Artigo em Inglês | MEDLINE | ID: mdl-19887610

RESUMO

In previous studies, we reported that key antioxidant and DNA repair genes are regulated differently in normal bronchial epithelial cells of lung cancer cases compared with non-lung cancer controls. In an effort to develop a biomarker for lung cancer risk, we evaluated the transcript expressions of 14 antioxidant, DNA repair, and transcription factor genes in normal bronchial epithelial cells (HUGO names CAT, CEBPG, E2F1, ERCC4, ERCC5, GPX1, GPX3, GSTM3, GSTP1, GSTT1, GSTZ1, MGST1, SOD1, and XRCC1). A test comprising these 14 genes accurately identified the lung cancer cases in two case-control studies. The receiver operating characteristic-area under the curve was 0.82 (95% confidence intervals, 0.68-0.91) for the first case-control set (25 lung cancer cases and 24 controls), and 0.87 (95% confidence intervals, 0.73-0.96) for the second set (18 cases and 22 controls). For each gene included in the test, the key difference between cases and controls was altered distribution of transcript expression among cancer cases compared with controls, with more lung cancer cases expressing at both extremes among all genes (Kolmorogov-Smirnov test, D = 0.0795; P = 0.041). A novel statistical approach was used to identify the lower and upper boundaries of transcript expression that optimally classifies cases and controls for each gene. Based on the data presented here, there is an increased prevalence of lung cancer diagnosis among individuals that express a threshold number of key antioxidant, DNA repair, and transcription factor genes at either very high or very low levels in the normal airway epithelium.


Assuntos
Antioxidantes/fisiologia , Biomarcadores Tumorais/genética , Reparo do DNA/genética , Expressão Gênica , Predisposição Genética para Doença , Neoplasias Pulmonares/genética , Adulto , Idoso , Idoso de 80 Anos ou mais , Área Sob a Curva , Estudos de Casos e Controles , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Curva ROC , Mucosa Respiratória/fisiologia , Reação em Cadeia da Polimerase Via Transcriptase Reversa
6.
Clin Chem ; 53(6): 1030-7, 2007 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-17434908

RESUMO

BACKGROUND: Transcript abundance (TA) measurement in whole blood frequently is conducted to identify potential biomarkers for disease risk and to predict or monitor drug response. Potential biomarkers discovered in this way must be validated by quantitative technology. In this study we assessed the use of standardized reverse transcription PCR (StaRT-PCR) to validate potential biomarkers discovered through whole blood TA profiling. METHODS: For each of 15 healthy volunteers, 6 blood samples were obtained, including 3 samples at each of 2 separate visits. Total variation in TA for each gene was partitioned into replicate, sample, visit, study participant, and residual components. RESULTS: Variation originating from technical processing was <5% of total combined variation and was primarily preanalytical. Interindividual biological sample variation was larger than technical variation. For 12 of 19 tests, the distribution of measured values was gaussian (Shapiro-Wilks test). CONCLUSION: For control or diseased population groups with variation rates as low as those observed in this control group, 17 individuals per group would be required to detect 1 SD change with 80% power with a 2-sided alpha = 0.05 statistical test for mean differences.


Assuntos
Biomarcadores/sangue , Perfilação da Expressão Gênica/normas , Variação Genética , Técnicas de Diagnóstico Molecular/normas , Interpretação Estatística de Dados , Perfilação da Expressão Gênica/estatística & dados numéricos , Humanos , Técnicas de Diagnóstico Molecular/estatística & dados numéricos , Controle de Qualidade , Valores de Referência , Reação em Cadeia da Polimerase Via Transcriptase Reversa
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA