RESUMO
Primary aldosteronism (PA) is the leading secondary cause of hypertension. Determining whether one (unilateral) or both (bilateral) adrenal glands are the source of PA in a patient remains challenging, and yet it is a critical step in the decision whether to recommend potentially curative surgery (adrenalectomy) or lifelong medical therapy (typically requiring multiple drugs). Recently, we have developed a fluorine-18 radiopharmaceutical [18 F]CETO to permit greater access to PA molecular imaging. Herein, we report an automated synthesis of this radiotracer. To manufacture the radiopharmaceutical routinely for clinical PET studies, we implemented an automated radiosynthesis method on a Synthra RNplus© synthesiser for which Cl-tosyletomidate was used as the precursor for radiolabelling via nucleophilic [18 F]fluorination. [18 F]CETO was produced with 35 ± 1% (n = 7), decay corrected and 25 ± 4% (n = 7) non-decay corrected radiochemical yield with molar activities ranging from 150 to 400 GBq/µmol. The GMP compliant manufacturing process produces a sterile formulated [18 F]CETO injectable solution for human use as demonstrated by the results of quality control. Automation of the radiosynthesis of [18 F]CETO should facilitate uptake by other adrenal centres and increase access to molecular imaging in PA.
Assuntos
Radioisótopos de Flúor , Compostos Radiofarmacêuticos , Humanos , Radioisótopos de Flúor/química , Imagem Molecular , Glândulas Suprarrenais , Radioquímica/métodos , Tomografia por Emissão de Pósitrons/métodosRESUMO
Blood-based kinetic analysis of PET data relies on an accurate estimate of the arterial plasma input function (PIF). An alternative to invasive measurements from arterial sampling is an image-derived input function (IDIF). However, an IDIF provides the whole blood radioactivity concentration, rather than the required free tracer radioactivity concentration in plasma. To estimate the tracer PIF, we corrected an IDIF from the carotid artery with estimates of plasma parent fraction (PF) and plasma-to-whole blood (PWB) ratio obtained from five venous samples. We compared the combined IDIF+venous approach to gold standard data from arterial sampling in 10 healthy volunteers undergoing [18F]GE-179 brain PET imaging of the NMDA receptor. Arterial and venous PF and PWB ratio estimates determined from 7 patients with traumatic brain injury (TBI) were also compared to assess the potential effect of medication. There was high agreement between areas under the curves of the estimates of PF (r = 0.99, p<0.001), PWB ratio (r = 0.93, p<0.001), and the PIF (r = 0.92, p<0.001) as well as total distribution volume (VT) in 11 regions across the brain (r = 0.95, p<0.001). IDIF+venous VT had a mean bias of -1.7% and a comparable regional coefficient of variation (arterial: 21.3 ± 2.5%, IDIF+venous: 21.5 ± 2.0%). Simplification of the IDIF+venous method to use only one venous sample provided less accurate VT estimates (mean bias 9.9%; r = 0.71, p<0.001). A version of the method that avoids the need for blood sampling by combining the IDIF with population-based PF and PWB ratio estimates systematically underestimated VT (mean bias -20.9%), and produced VT estimates with a poor correlation to those obtained using arterial data (r = 0.45, p<0.001). Arterial and venous blood data from 7 TBI patients showed high correlations for PF (r = 0.92, p = 0.003) and PWB ratio (r = 0.93, p = 0.003). In conclusion, the IDIF+venous method with five venous samples provides a viable alternative to arterial sampling for quantification of [18F]GE-179 VT.
Assuntos
Lesões Encefálicas Traumáticas/metabolismo , Neuroimagem/normas , Tomografia por Emissão de Pósitrons/normas , Compostos Radiofarmacêuticos/farmacocinética , Receptores de N-Metil-D-Aspartato/metabolismo , Adulto , Lesões Encefálicas Traumáticas/diagnóstico por imagem , Feminino , Humanos , Masculino , Pessoa de Meia-Idade , Neuroimagem/métodos , Tomografia por Emissão de Pósitrons/métodos , Reprodutibilidade dos Testes , VeiasRESUMO
An automated radiosynthesis of carbon-11 positron emission tomography radiotracer [11 C]UCB-J for imaging the synaptic density biomarker synaptic vesicle glycoprotein SV2A was established using Synthra RNPlus synthesizer. Commercially available trifluoroborate UCB-J analogue was used as a radiolabelling precursor, and the desired radiolabelled product was isolated in 11 ± 2% (n = 7) nondecay corrected radiochemical yield and formulated as a 10% EtOH solution in saline with molar activities of 20 to 100 GBq/µmol. The method was based upon the palladium(0)-mediated Suzuki cross-coupling reaction and [11 C]CH3 I as a radiolabelling synthon. The isolated product was cGMP compliant as demonstrated by the results of quality control analysis.
Assuntos
Tomografia por Emissão de Pósitrons , Piridinas/síntese química , Pirrolidinonas/síntese química , Sinapses/metabolismo , Animais , Automação , Encéfalo/diagnóstico por imagem , Encéfalo/metabolismo , Técnicas de Química Sintética , Macaca mulatta , Paládio/química , Piridinas/química , Pirrolidinonas/química , RadioquímicaRESUMO
The performance of the charged aerosol detector (CAD) was investigated using a diverse set of 29 solutes, including acids, bases and neutrals, over a range of mobile phase compositions, particularly with regard to its suitability for use in hydrophilic interaction chromatography (HILIC). Flow injection analysis was employed as a rapid method to study detector performance. CAD response was 'quasi-universal', strong signals were observed for compounds that have low volatility at typical operating (room) temperature. For relatively involatile solutes, response was reasonably independent of solute chemistry, giving variation of 12-18% RSD from buffered 95% ACN (HILIC) to 10% ACN (RP). Somewhat higher response was obtained for basic compared with neutral solutes. For cationic basic solutes, use of anionic reagents of increasing size in the mobile phase (formic, trifluoroacetic and heptafluorobutyric acid) produced somewhat increased detector response, suggesting that salt formation with these reagents is contributory. However, the increase was not stoichiometric, pointing to a complex mechanism. In general, CAD response increased as the concentration of acetonitrile in the mobile phase was increased from highly aqueous (10% ACN) to values typical in the HILIC range (80-95% ACN), with signal to noise ratios about four times higher than those for the RP range. The response of the CAD is non-linear. Equations describing aerosol formation cannot entirely explain the shape of the plots. Limits of detection (determined with a column for solutes of low k) under HILIC conditions were of the order of 1-3ng on column, which compares favourably with other universal detectors. CAD response to inorganic anions allows observation of the independent movement through the column of the cationic and anionic constituents of basic drugs, which appear to be accompanied by mobile phase counterions, even at quite high solute concentrations.
Assuntos
Aerossóis/análise , Acetonitrilas , Soluções Tampão , Cromatografia Líquida de Alta Pressão/métodos , Concentração de Íons de Hidrogênio , Interações Hidrofóbicas e Hidrofílicas , Solventes , ÁguaRESUMO
The retention and peak shape of neutral, basic and acidic solutes was studied on hydrophilic interaction chromatography (HILIC) stationary phases that showed both strong and weak ionic retention characteristics, using aqueous-acetonitrile mobile phases containing either formic acid (FA), ammonium formate (AF) or phosphoric acid (PA). The effect of organic solvent concentration on the results was also studied. Peak shape was good for neutrals under most mobile phase conditions. However, peak shapes for ionised solutes, particularly for basic compounds, were considerably worse in FA than AF. Even neutral compounds showed deterioration in performance with FA when the mobile phase water concentration was reduced. The poor performance in FA cannot be entirely attributed to the negative impact of ionic retention on ionised silanols on the underlying silica base materials, as results using PA at lower pH (where their ionisation is suppressed) were inferior to those in AF. Besides the moderating influence of the salt cation on ionic retention, it is likely that salt buffers improve peak shape due to the increased ionic strength of the mobile phase and its impact on the formation of the water layer on the column surface.