Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 8 de 8
Filtrar
1.
Environ Res ; 178: 108721, 2019 11.
Artigo em Inglês | MEDLINE | ID: mdl-31541805

RESUMO

Legionella is the causative agent of Legionnaires' disease, a flu-like illness normally acquired following inhalation or aspiration of contaminated water aerosols. Our recent studies revealed that climatic parameters can increase the number of reported cases of community-acquired Legionnaires' disease. Here, we evaluated the presence of Legionella in water networks and the distribution of Legionnaires' disease cases associated with touristic-recreational facilities in the Apulia region (southern Italy) during the period 2001-2017 using geostatistical and climatic analyses. Geostatistical analysis data revealed that the area with the highest concentration of Legionella in water systems also had the greatest number of cases of Legionnaires' disease associated with touristic-recreational facilities. Climatic analysis showed that higher daily temperature excursion (difference between maximum and minimum temperature) on the day of sampling was more often associated with Legionella-positive samples than Legionella-negative samples. In addition, our data highlighted an increased risk of Legionnaires' disease with increases in precipitation and average temperature and with decreases in daily temperature excursion (difference between maximum and minimum temperature over the course of 24 h in the days of incubation period of disease) and minimum temperature. Healthcare professionals should be aware of this phenomenon and be particularly vigilant for cases of community-acquired pneumonia during such climatic conditions and among the tourist population. The innovative geo-statistical approach used in this study could be applied in other contexts when evaluating the effects of climatic conditions on the incidence of Legionella infections.


Assuntos
Exposição Ambiental/estatística & dados numéricos , Legionelose/epidemiologia , Clima , Humanos , Itália/epidemiologia , Legionella , Legionella pneumophila , Doença dos Legionários , Microbiologia da Água
2.
Environ Res ; 166: 55-60, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-29864633

RESUMO

Risk assessment, environmental monitoring, and the disinfection of water systems are the key elements in preventing legionellosis risk. The Italian Study Group of Hospital Hygiene of the Italian Society of Hygiene, Preventive Medicine, and Public Health and the Italian Multidisciplinary Society for the Prevention of Health Care-Associated Infections carried out a national cross-sectional survey to investigate the measures taken to prevent and control legionellosis in Italian hospitals. A multiple-choice questionnaire was developed, comprising 71 questions regarding hospital location, general characteristics, clinical and environmental surveillance, and control and preventive measures for legionellosis in 2015. Overall, 739 hospitals were enrolled from February to June 2017, and 178 anonymous questionnaires were correctly completed and evaluated (response rate: 24.1%). The survey was conducted using the SurveyMonkey® platform, and the data were analyzed using Stata 12 software. Of the participating hospitals, 63.2% reported at least one case of legionellosis, of which 28.2% were of proven nosocomial origin. The highest case numbers were reported in the Northern Italy, in hospitals with a pavilion structure or cooling towers, and in hospitals with higher numbers of beds, wards and operating theaters. Laboratory diagnosis was performed using urinary antigen testing alone (31.9%), both urinary antigen testing and single antibody titer (17.8%), or with seroconversion also added (21.5%). Culture-based or molecular investigations were performed in 28.8% and 22.1% of the clinical specimens, respectively. The water systems were routinely tested for Legionella in 97.4% of the hospitals, 62% of which detected a positive result (> 1000 cfu/L). Legionella pneumophila serogroup 2-15 was the most frequently isolated species (58.4%). The most common control measures were the disinfection of the water system (73.7%), mostly through thermal shock (37.4%) and chlorine dioxide (34.4%), and the replacement (69.7%) or cleaning (70.4%) of faucets and showerheads. A dedicated multidisciplinary team was present in 52.8% of the hospitals, and 73% of the hospitals performed risk assessment. Targeted training courses were organized in 36.5% of the hospitals, involving nurses (30.7%), physicians (28.8%), biologists (21.5%), technicians (26.4%), and cleaners (11%). Control and prevention measures for legionellosis are present in Italian hospitals, but some critical aspects should be improved. More appropriate risk assessment is necessary, especially in large facilities with a high number of hospitalizations. Moreover, more sensitive diagnostic tests should be used, and dedicated training courses should be implemented.


Assuntos
Controle de Infecções/métodos , Legionella pneumophila/isolamento & purificação , Legionelose/prevenção & controle , Abastecimento de Água , Infecção Hospitalar/epidemiologia , Infecção Hospitalar/prevenção & controle , Estudos Transversais , Desinfecção , Humanos , Itália/epidemiologia , Legionelose/epidemiologia , Inquéritos e Questionários , Microbiologia da Água
3.
Environ Res ; 142: 586-90, 2015 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-26298602

RESUMO

OBJECTIVES: The purpose of this study was to describe the susceptibility of environmental strains of Legionella spp. to 10 antimicrobials commonly used for legionellosis therapy. A study of environmental strains could be useful to timely predict the onset of antibiotic resistance in the environment before it is evidenced in clinical specimens. METHODS: The minimum inhibitory concentrations (MICs) of 100 environmental Legionella pneumophila (Lpn) strains belonging to serogroups (sgs) 1, 6, 8, and 10 were tested using the E-test methodology on buffered charcoal yeast extract agar supplemented with α-ketoglutarate. The most frequent sgs were selected from those obtained during microbiological surveillance conducted in 2014 in a hospital in Southern Italy. The MICs were read after 2 days of incubation at 35 °C in a humidified atmosphere without CO2. RESULTS: All isolates were inhibited by low concentrations of fluoroquinolones and macrolides. Rifampicin was the most active drug against the isolates in vitro. All Lpn isolates were inhibited by the following drugs (in decreasing order of their MICs): doxycycline>tigecycline>cefotaxime. The MICs of azithromycin, ciprofloxacin, levofloxacin, moxifloxacin, and tigecycline were significantly lower for Lpn non-sg 1 than Lpn sg 1 isolates. CONCLUSIONS: Susceptibility testing of Legionella strains to appropriate antibiotics should be performed often to evaluate the possible emergence of resistance, to improve the outcomes of patients, and to reduce the direct costs associated with hospitalization.


Assuntos
Antibacterianos/farmacologia , Hospitais , Legionella pneumophila/efeitos dos fármacos , Microbiologia da Água , Abastecimento de Água , Itália , Testes de Sensibilidade Microbiana
4.
Ann Ig ; 27(3): 590-4, 2015.
Artigo em Inglês | MEDLINE | ID: mdl-26152545

RESUMO

OBJECTIVE: Listeria monocytogenes is currently considered a relevant emerging food-borne pathogen. In particular, the European Centre for Disease Prevention and Control (ECDC) illustrates its widespread presence in different foods. In the present article, L. monocytogenes prevalence was estimated in cooked ready-to-eat foods sampled from a catering service in a Apulia city, southern Italy. METHODS: The study was carried out from January to June 2014 in according to Regulation (EC) No. 852/2004, and ISO 11290-1:1996/Amd.1:2004 methods. RESULTS: Listeria spp. was isolated in 8.3% of the samples: L. monocytogenes was identified with the highest prevalence in potato gateau (66.6%), followed by rice dishes (11.1%), Listeria innocua was isolated from potato purea (11.1%) and cooked vegetables (11.1%). CONCLUSIONS: These preliminary results confirm the diffusion of the microorganism in ready-to-eat products; therefore, strategies aimed at protecting the consumers should be adopted. First of all, correct hygiene procedures should be followed and then microbiological tests should be implemented in order to early detect Listeria spp. (not only LM) contamination in cooked foods.


Assuntos
Contaminação de Alimentos/análise , Microbiologia de Alimentos , Listeria monocytogenes/isolamento & purificação , Culinária , Humanos , Itália , Fatores de Tempo
5.
Artigo em Inglês | MEDLINE | ID: mdl-32252266

RESUMO

Food ice is used as an ingredient or as a coolant in drinks and in the storage of food, especially fishery products. Studies show that ice can be polluted both by chemical substances and by bacteria and fungi. In particular, the presence of fungi in these food matrices has acquired an important role in Public Health, as it can represent a risk factor for fungal complications in immunocompromised subjects. In the present study we evaluated the hygiene-sanitary quality of food ice from public and collective catering establishments in a large area of Southern Italy, investigating the mandatory parameters (Escherichia coli, coliform and Enterococci) and some accessory parameters (Staphylococcus aureus, Pseudomonas aeruginosa and fungi) provided for Italian Legislative Decree 31/01. Although 54.5% of samples were compliant, the results highlight a vast contamination of food ice by bacteria and fungi. In particular, 95.8% of samples were contaminated by fungi, stressing no difference between compliant and non-compliant samples. Their presence is generally attributable to the poor sanitation conditions in the production and/or administration phase and to the incorrect sanitization and ordinary maintenance procedures. It seems appropriate to suggest the need to carry out a specific risk assessment with respect to the self-control plans.


Assuntos
Contaminação de Alimentos , Microbiologia de Alimentos , Armazenamento de Alimentos , Gelo , Saúde Pública , Enterococcus , Humanos , Higiene , Itália
6.
Artigo em Inglês | MEDLINE | ID: mdl-31146343

RESUMO

Nosocomial infections cause significant morbidity and mortality worldwide, and the pathogenic organisms responsible for such infections can develop resistance to antimicrobial agents. Understanding the activity of disinfectants against clinical and environmental bacterial isolates is therefore crucial. We analysed the in vitro activity of five antimicrobial products (phenolic compounds, didecyldimethylammonium chloride (DDAC), sodium hypochlorite, isopropanol + ammonium compounds (IACs), hydrogen peroxide) against 187 bacterial strains comprising clinical isolates, as well as 30 environmental isolates of Pseudomonas aeruginosa from hospital water samples. Disk diffusion assays were employed to assess antimicrobial activity. Hydrogen peroxide was significantly more active (p < 0.0001) than the other disinfectants against all P. aeruginosa, Klebsiella pneumoniae, Enterococcus faecalis and Staphylococcus aureus strains. It was also the only disinfectant with activity against both clinical and environmental strains of P. aeruginosa. DDAC and IAC-based disinfectants were ineffective against Gram-negative strains, but showed significant activity (particularly IACs, p < 0.0001) against the Gram-positive strains. Compared with IACs, DDAC was significantly more active on E. faecalis and less active on S. aureus (p < 0.0001). Sodium hypochlorite and phenol compounds, by contrast, were inactive against all bacterial strains. The development of disinfection procedures that are effective against all microorganisms is essential for limiting the spread of nosocomial infections.


Assuntos
2-Propanol/farmacologia , Compostos de Amônio/farmacologia , Bactérias/efeitos dos fármacos , Desinfetantes/farmacologia , Peróxido de Hidrogênio/farmacologia , Fenóis/farmacologia , Hipoclorito de Sódio/farmacologia , Infecção Hospitalar/prevenção & controle , Hospitais , Microbiologia da Água , Abastecimento de Água
7.
Artigo em Inglês | MEDLINE | ID: mdl-31557819

RESUMO

Postoperative infections are a concern, especially in total knee and total hip arthroplasty. We evaluated the air quality in orthopaedic operating theatres in southeastern Italy to determine the level of bacterial contamination as a risk factor for postoperative infection. Thirty-five hospitals with operating theatres focused on total knee and total hip arthroplasty participated. We sampled the air passively and actively before surgeries began for the day (at rest) and 15 min after the surgical incision (in operation). We evaluated bacterial counts, particle size, mixed vs turbulent airflow systems, the number of doors, number of door openings during procedures and number of people in the operating theatre. We found no bacterial contamination at rest for all sampling methods, and significantly different contamination levels at rest vs in operation. We found no association between the number of people in the surgical team and bacteria counts for both mixed and turbulent airflow systems, and low bacterial loads, even when doors were always open. Overall, the air quality sampling method and type of ventilation system did not affect air quality.


Assuntos
Microbiologia do Ar , Poluição do Ar/estatística & dados numéricos , Salas Cirúrgicas/estatística & dados numéricos , Ar Condicionado , Poluição do Ar/análise , Artroplastia de Quadril , Artroplastia do Joelho , Carga Bacteriana , Hospitais , Humanos , Itália , Ortopedia , Ventilação/métodos
8.
J Med Microbiol ; 66(2): 213-216, 2017 03.
Artigo em Inglês | MEDLINE | ID: mdl-27959780

RESUMO

The antifungal susceptibilities of 598 isolates of Candida spp. (bloodstream and other sterile sites) to liposomal amphotericin B (L-AmB) versus amphotericin B (AmB) were determined. MICs were calculated using the Clinical and Laboratory Standards Institute broth microdilution (M27-A3) method for L-AmB and the Etest method for AmB. The MIC50/MIC90 (µg ml-1) values for L-AmB broth microdilution and AmB Etest were 0.25/1 and 0.19/0.5, respectively. The overall essential agreement (±2 dilutions) was 91.5 %, ranging from 37.5 % (Candida lusitaniae) to 100 % (Candida glabrata and Candida krusei). Categorical agreement between the two methods was categorized based on a previously published breakpoint (susceptible/resistant MIC cut-off of 1 µg ml-1). The overall categorical agreement at the 48 h reading was 97.3 %, ranging from 72.7 % (C. krusei) to 100 % (Candida albicans). Major and very major discrepancies occurred in 2.3 and 0.3 %, respectively. Spearman's ρ was 0.48 (P<0.0001). These results demonstrate the utility of the AmB Etest as a surrogate marker to predict the sensibility and resistance of Candida spp. to L-AmB and thus to support its use in antifungal treatment.


Assuntos
Anfotericina B/farmacologia , Candida/efeitos dos fármacos , Ácido Desoxicólico/farmacologia , Testes de Sensibilidade a Antimicrobianos por Disco-Difusão/métodos , Farmacorresistência Fúngica , Testes de Sensibilidade Microbiana , Antifúngicos/farmacologia , Candida/classificação , Candida albicans/efeitos dos fármacos , Candida glabrata/efeitos dos fármacos , Combinação de Medicamentos , Humanos
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA