Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 7 de 7
Filtrar
Mais filtros

Base de dados
Tipo de documento
Assunto da revista
País de afiliação
Intervalo de ano de publicação
1.
Anal Chem ; 95(19): 7458-7467, 2023 05 16.
Artigo em Inglês | MEDLINE | ID: mdl-37146167

RESUMO

Herein, we report a novel liquid chromatography coupled with tandem mass spectrometry method to characterize N-acetylneuraminic acid (Neu5Ac, Sa) linkage in N-linked glycans in glycopeptides with no sialic acid derivatization. First, we established a separation in reversed-phase high-performance liquid chromatography (HPLC) using a higher formic acid concentration in the mobile phases, which separated the N-glycopeptides depending on the Sa linkage. We also demonstrated a novel characterization method of Sa linkages in N-glycopeptides using electron-activated dissociation. We found that hot electron capture dissociation using an electron beam energy higher than 5 eV cleaved glycosidic bonds in glycopeptides, resulting in each glycosidic bond in the antennas being broken on both sides of the oxygen atom. Such glycosidic bond cleavage at the reducing end (C-type ion) showed the difference in Sa linkages between Sa-Gal, Gal-GlcNAc, and GlcNAc-Man. We proposed a rule to characterize the Sa linkages using the Sa-Gal products. This method was applied to N-glycopeptides in tryptic fetuin digest separated by an optimized reversed-phase HPLC. We successfully identified a number of isomeric glycoforms in the glycopeptides with different Sa links, whose peptide backbones were also simultaneously sequenced by hot ECD.


Assuntos
Glicopeptídeos , Ácido N-Acetilneuramínico , Humanos , Ácido N-Acetilneuramínico/química , Glicopeptídeos/análise , Elétrons , Cromatografia Líquida/métodos , Espectrometria de Massas em Tandem/métodos
2.
J Proteome Res ; 21(10): 2462-2471, 2022 Oct 07.
Artigo em Inglês | MEDLINE | ID: mdl-36074808

RESUMO

We describe a method to obtain a comprehensive profile of multiple glycosylations in glycopeptide isoforms. We detected a wide range of abundances of various O-glycoforms in isomeric glycopeptides using hot electron capture dissociation (hot ECD) in liquid chromatography-tandem mass spectrometry. To capture low abundant glycosylated species, a prototype of a ZenoTOF 7600 system incorporating an efficient electron-activated dissociation device to perform hot ECD was operated in targeted or scheduled high-resolution multiple reaction monitoring workflows. In addition, Zeno trap pulsing was activated to enhance the sensitivity of the time-of-flight mass spectrometer. Sixty-nine O-glycopeptides of the long O-glycopeptides in tryptic bovine fetuin digest were obtained with a relative abundance range from 100 to 0.2%, which included sialylated glycans with Neu5Ac and Neu5Gc.


Assuntos
Glicopeptídeos , Espectrometria de Massas em Tandem , Animais , Bovinos , Elétrons , Fetuínas , Glicopeptídeos/análise , Polissacarídeos/química , Isoformas de Proteínas , Espectrometria de Massas em Tandem/métodos
3.
Rapid Commun Mass Spectrom ; 35 Suppl 1: e8246, 2021 Jan.
Artigo em Inglês | MEDLINE | ID: mdl-30067883

RESUMO

RATIONALE: Liquid atmospheric pressure matrix-assisted laser desorption/ionisation (AP-MALDI) has been shown to enable the production of electrospray ionisation (ESI)-like multiply charged analyte ions with little sample consumption and long-lasting, robust ion yield for sensitive analysis by mass spectrometry (MS). Previous reports have focused on positive ion production. Here, we report an initial optimisation of liquid AP-MALDI for ESI-like negative ion production and its application to the analysis of peptides/proteins, DNA and lipids. METHODS: The instrumentation employed for this study is identical to that of earlier liquid AP-MALDI MS studies for positive analyte ion production with a simple non-commercial AP ion source that is attached to a Waters Synapt G2-Si mass spectrometer and incorporates a heated ion transfer tube. The preparation of liquid MALDI matrices is similar to positive ion mode analysis but has been adjusted for negative ion mode by changing the chromophore to 3-aminoquinoline and 9-aminoacridine for further improvements. RESULTS: For DNA, liquid AP-MALDI MS analysis benefited from switching to 9-aminoacridine-based MALDI samples and the negative ion mode, increasing the number of charges by up to a factor of 2 and the analyte ion signal intensities by more than 10-fold compared with the positive ion mode. The limit of detection was recorded at around 10 fmol for ATGCAT. For lipids, negative ion mode analysis provided a fully orthogonal set of detected lipids. CONCLUSIONS: Negative ion mode is a sensitive alternative to positive ion mode in liquid AP-MALDI MS analysis. In particular, the analysis of lipids and DNA benefited from the complementarity of the detected lipid species and the vastly greater DNA ion signal intensities in negative ion mode.

4.
Methods ; 104: 11-20, 2016 07 15.
Artigo em Inglês | MEDLINE | ID: mdl-26827934

RESUMO

Liquid matrix-assisted laser desorption/ionization (MALDI) allows the generation of predominantly multiply charged ions in atmospheric pressure (AP) MALDI ion sources for mass spectrometry (MS) analysis. The charge state distribution of the generated ions and the efficiency of the ion source in generating such ions crucially depend on the desolvation regime of the MALDI plume after desorption in the AP-to-vacuum inlet. Both high temperature and a flow regime with increased residence time of the desorbed plume in the desolvation region promote the generation of multiply charged ions. Without such measures the application of an electric ion extraction field significantly increases the ion signal intensity of singly charged species while the detection of multiply charged species is less dependent on the extraction field. In general, optimization of high temperature application facilitates the predominant formation and detection of multiply charged compared to singly charged ion species. In this study an experimental set-up and optimization strategy is described for liquid AP-MALDI MS which improves the ionization efficiency of selected ion species up to 14 times. In combination with ion mobility separation, the method allows the detection of multiply charged peptide and protein ions for analyte solution concentrations as low as 2fmol/µL (0.5µL, i.e. 1fmol, deposited on the target) with very low sample consumption in the low nL-range.


Assuntos
Peptídeos/isolamento & purificação , Proteínas/isolamento & purificação , Espectrometria de Massas por Ionização e Dessorção a Laser Assistida por Matriz/métodos , Pressão Atmosférica , Íons/química , Peptídeos/química , Proteínas/classificação
5.
J Am Soc Mass Spectrom ; 33(9): 1723-1732, 2022 Sep 07.
Artigo em Inglês | MEDLINE | ID: mdl-35948044

RESUMO

We report on the dissociation of singly protonated peptides by electrons using electron-activated dissociation (EAD), which comprises electron impact excitation of ions from organics (EIEIO), electronic-excitation dissociation (EED), and electron ionization dissociation (EIoD). Various singly protonated peptides were dissociated using a recently reported fast EAD device. The dissociation can be induced through two pathways: (i) vibrational dissociation similar to collision-activated dissociation (CAD, or collision-induced dissociation, CID) by relaxation from a molecular electronic excited state to high vibrational states; and (ii) radical-induced dissociation where molecular electronic excitation is followed by homolytic cleavage. EAD is complementary to CAD as additional molecular information can be obtained; e.g., fragile PTM moieties, such as glycosylation and sulfation, can be localized. Simultaneously, the energetic production of radical z• fragments enables Leu and Ile discrimination, like in a hot ECD process. Using the fast EAD device, LC-EIEIO-time-of-flight mass spectrometry was applied to a tryptic monoclonal antibody digest containing short singly protonated peptides.


Assuntos
Elétrons , Peptídeos , Íons/química , Espectrometria de Massas/métodos , Peptídeos/química , Processamento de Proteína Pós-Traducional
6.
J Am Soc Mass Spectrom ; 32(8): 1964-1975, 2021 Aug 04.
Artigo em Inglês | MEDLINE | ID: mdl-34080873

RESUMO

We report the progress on an electron-activated dissociation (EAD) device coupled to a quadrupole TOF mass spectrometer (QqTOF MS) developed in our group. This device features a new electron beam optics design allowing up to 100 times stronger electron currents in the reaction cell. The electron beam current reached the space-charge limit of 0.5 µA at near-zero electron kinetic energies. These advances enable fast and efficient dissociation of various analytes ranging from singly charged small molecules to multiply protonated proteins. Tunable electron energy provides access to different fragmentation regimes: ECD, hot ECD, and electron-impact excitation of ions from organics (EIEIO). The efficiency of the device was tested on a wide range of precursor charge states. The EAD device was installed in a QqTOF MS employing a novel trap-and-release strategy facilitating spatial mass focusing of ions at the center of the TOF accelerator. This technique increased the sensitivity 6-10 times and allows for the first time comprehensive structural lipidomics on an LC time scale. The system was evaluated for other compound classes such as intact proteins and glycopeptides. Application of hot ECD for the analysis of glycopeptides resulted in rich fragmentation with predominantly peptide backbone fragments; however, glycan fragments attributed to the ECD process were also observed. A standard small protein ubiquitin (8.6 kDa) was sequenced with 90% cleavage coverage at spectrum accumulation times of 100 ms and 98% at 800 ms. Comparable cleavage coverage for a medium-size protein (carbonic anhydrase: 29 kDa) could be achieved, albeit with longer accumulation times.


Assuntos
Glicopeptídeos/química , Proteínas/química , Espectrometria de Massas em Tandem/instrumentação , Espectrometria de Massas em Tandem/métodos , Produtos Biológicos/análise , Produtos Biológicos/química , Anidrase Carbônica II/química , Gema de Ovo/química , Elétrons , Desenho de Equipamento , Glicopeptídeos/análise , Íons/química , Fosfatidilcolinas/análise , Fosfatidilcolinas/química , Proteínas/análise , Sensibilidade e Especificidade , Soroalbumina Bovina/análise , Soroalbumina Bovina/química , Ubiquitina/química
7.
Anal Chim Acta ; 1013: 43-53, 2018 Jul 12.
Artigo em Inglês | MEDLINE | ID: mdl-29501091

RESUMO

New liquid atmospheric pressure (AP) matrix-assisted laser desorption/ionization (MALDI) matrices that produce predominantly multiply charged ions have been developed and evaluated with respect to their performance for peptide and protein analysis by mass spectrometry (MS). Both the chromophore and the viscous support liquid in these matrices were optimized for highest MS signal intensity, S/N values and maximum charge state. The best performance in both protein and peptide analysis was achieved employing light diols as matrix support liquids (e.g. ethylene glycol and propylene glycol). Investigating the influence of the chromophore, it was found that 2,5-dihydroxybenzoic acid resulted in a higher analyte ion signal intensity for the analysis of small peptides; however, larger molecules (>17 kDa) were undetectable. For larger molecules, a sample preparation based on α-cyano-4-hydroxycinnammic acid as the chromophore was developed and multiply protonated analytes with charge states of more than 50 were detected. Thus, for the first time it was possible to detect with MALDI MS proteins as large as ∼80 kDa with a high number of charge states, i.e. m/z values below 2000. Systematic investigations of various matrix support liquids have revealed a linear dependency between laser threshold energy and surface tension of the liquid MALDI sample.

SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA