Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 3 de 3
Filtrar
1.
Clin Biomech (Bristol, Avon) ; 102: 105889, 2023 02.
Artigo em Inglês | MEDLINE | ID: mdl-36774735

RESUMO

BACKGROUND: Patient-specific autonomous finite element analyses of femurs, based on clinical computed tomography scans may be used to monitor the progression of bone-related diseases. Some CT scan protocols provide lower resolution (slice thickness of 3 mm) that affects the accuracy. To investigate the impact of low-resolution scans on the CT-based finite element analyses results, identical CT raw data were reconstructed twice to generate a 1 mm ("gold standard") and a 3 mm slice thickness scans. METHODS: CT-based finite element analyses of twenty-four femurs (twelve patients) under stance and sideways fall loads were performed based on 1 and 3 mm slice thickness scans. Bone volume, load direction, and strains were extracted at different locations along the femurs and differences were evaluated. FINDINGS: Average differences in bone volume were 1.0 ± 1.5%. The largest average difference in strains in stance position was in the neck region (11.0 ± 13.4%), whereas in other regions these were much smaller. For sidewise fall loading, the average differences were at most 9.2 ± 16.0%. INTERPRETATION: Whole-body low dose CT scans (3 mm-slice thickness) are suboptimal for monitoring strain changes in patient's femurs but may allow longitudinal studies if larger than 5% in all areas and larger than 12% in the upper neck. CT-based finite element analyses with slice thickness of 3 mm may be used in clinical practice for patients with smoldering myeloma to associate changes in strains with progression to active myeloma if above ∼10%.


Assuntos
Fêmur , Tomografia Computadorizada por Raios X , Humanos , Análise de Elementos Finitos , Tomografia Computadorizada por Raios X/métodos , Acidentes por Quedas
2.
Hip Int ; 33(2): 241-246, 2023 Mar.
Artigo em Inglês | MEDLINE | ID: mdl-34784811

RESUMO

BACKGROUND: Femoral anteversion is a major contributor to functionality of the hip joint and is implicated in many joint pathologies. Accurate determination of component version intraoperatively is a technically challenging process that relies on the visual estimation of the surgeon. The following study aimed to examine whether the walls of the femoral neck can be used as appropriate landmarks to ensure appropriate femoral prosthesis version intraoperatively. METHODS: We conducted a retrospective study based on 32 patients (64 hips) admitted to our centre between July and September 2020 who had undergone a CT scan of their lower limbs. Through radiological imaging analysis, the following measurements were performed bilaterally for each patient: anterior wall version, posterior wall version, and mid-neck femoral version. Anterior and posterior wall version were compared and evaluated relative to mid-neck version, which represented the true version value. RESULTS: Mean anterior wall anteversion was 20° (95% CI, 17.6-22.8°) and mean posterior wall anteversion was -12° (95% CI, -15 to -9.7°). The anterior walls of the femoral neck had a constant of -7 and a coefficient of 0.9 (95% CI, -9.8 to -4.2; p < 0.0001; R2 0.77).The posterior walls of the femoral neck had a constant of 20 and a coefficient of 0.7 (95% CI, 17.8-22.5; p < 0.0001; R2 0.60). CONCLUSIONS: Surgeons can accurately obtain femoral anteversion by subtracting 7° from the angle taken between the anterior wall and the posterior femoral condyles or by adding 20° to the angle taken between the posterior wall and the posterior femoral condyles.


Assuntos
Artroplastia de Quadril , Prótese de Quadril , Humanos , Colo do Fêmur/diagnóstico por imagem , Colo do Fêmur/cirurgia , Artroplastia de Quadril/métodos , Estudos Retrospectivos , Fêmur/diagnóstico por imagem , Fêmur/cirurgia , Fêmur/patologia , Articulação do Quadril/cirurgia
3.
Front Immunol ; 11: 561294, 2020.
Artigo em Inglês | MEDLINE | ID: mdl-33193330

RESUMO

Immunotherapy with anti-CD20-specific antibodies (rituximab), has become the standard of care for B cell lymphoproliferative disorders and many autoimmune diseases. In rheumatological patients the effect of rituximab on bone mass yielded conflicting results, while in lymphoma patients it has not yet been described. Here, we used cross-sectional X-ray imaging (CT/PET-CT) to serially assess bone density in patients with follicular lymphoma receiving rituximab maintenance therapy. Remarkably, this treatment prevented the decline in bone mass observed in the control group of patients who did not receive active maintenance therapy. In accordance with these data, anti-CD20-mediated B cell depletion in normal C57BL/6J female mice led to a significant increase in bone mass, as reflected by a 7.7% increase in bone mineral density (whole femur), and a ~5% increase in cortical as well as trabecular tissue mineral density. Administration of anti-CD20 antibodies resulted in a significant decrease in osteoclastogenic signals, including RANKL, which correlated with a reduction in osteoclastogenic potential of bone marrow cells derived from B-cell-depleted animals. Taken together, our data suggest that in addition to its anti-tumor activity, anti-CD20 treatment has a favorable effect on bone mass. Our murine studies indicate that B cell depletion has a direct effect on bone remodeling.


Assuntos
Antígenos CD20/imunologia , Antineoplásicos Imunológicos/administração & dosagem , Linfócitos B/imunologia , Densidade Óssea/efeitos dos fármacos , Reabsorção Óssea/terapia , Imunoterapia/métodos , Depleção Linfocítica , Linfoma Folicular/terapia , Rituximab/administração & dosagem , Adulto , Idoso , Animais , Estudos Transversais , Feminino , Humanos , Masculino , Camundongos , Camundongos Endogâmicos C57BL , Pessoa de Meia-Idade , Tomografia por Emissão de Pósitrons combinada à Tomografia Computadorizada , Estudos Retrospectivos , Resultado do Tratamento
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA