Your browser doesn't support javascript.
loading
Mostrar: 20 | 50 | 100
Resultados 1 - 4 de 4
Filtrar
1.
Inhal Toxicol ; 23(8): 459-67, 2011 Jul.
Artigo em Inglês | MEDLINE | ID: mdl-21689007

RESUMO

CONTEXT: Prolonged exposure to ambient particles is associated with premature mortality due to cardio-respiratory diseases and lung cancer. The size and composition of these particles determine their toxicity, which is aggravated by their long-term retention in the lungs. OBJECTIVE: To compare the elemental profile of particles retained along the bronchial tree and lymph nodes by combining laser capture microdissection (LCM) and elemental composition analysis through energy dispersive x-ray (EDX) and scanning electron microscopy (SEM). MATERIAL AND METHODS: Twenty-four right lung middle lobes from autopsied cases were obtained from two cities with different pollution backgrounds. Lung samples were collected from three distinct sites within the lung at the time of autopsy: peribronchial tissue, peripheral parenchyma and hilar lymph nodes. Areas of potentially increased particle deposition were microdissected using LCM and analyzed for elemental composition through EDX "allied" with SEM. RESULTS: Elemental analyses of the particles retained along the bronchial tree showed two groups of distribution: peribronchiolar or lymph node deposition. The elemental profile of peribronchial areas were significantly different between the two cities and were better discriminators of past air pollution exposure. CONCLUSION: Our data suggest that particle uptake varies along the bronchial tree and human lung tissue retains particles indicative of regional air pollution background.


Assuntos
Poluentes Atmosféricos/toxicidade , Brônquios/efeitos dos fármacos , Exposição por Inalação/efeitos adversos , Linfonodos/efeitos dos fármacos , Metais/análise , Material Particulado/toxicidade , Adulto , Idoso , Idoso de 80 Anos ou mais , Poluentes Atmosféricos/análise , Brasil , Brônquios/química , Brônquios/ultraestrutura , Monitoramento Ambiental , Feminino , Humanos , Lasers , Linfonodos/química , Linfonodos/ultraestrutura , Masculino , Microdissecção , Microscopia Eletrônica de Varredura , Pessoa de Meia-Idade , Material Particulado/análise , Espectrometria por Raios X , Saúde da População Urbana
2.
Cancer Cytopathol ; 126(10): 846-852, 2018 10.
Artigo em Inglês | MEDLINE | ID: mdl-30317695

RESUMO

BACKGROUND: The impact of rapid on-site evaluation (ROSE) on thyroid aspirates has been a matter of extensive debate. In the current study, the authors reviewed all thyroid fine-needle aspiration biopsies (FNABs) performed in their service in recent years to evaluate the impact of ROSE on final adequacy and diagnostic rates. METHODS: All ultrasound-guided FNABs of the thyroid performed between July 2015 and July 2017 were included retrospectively. ROSE was performed by experienced cytopathologists, with production of Romanowsky-stained slides for immediate evaluation. When ROSE was not performed, a total of 3 needle passes were performed as the default. Final specimen adequacy and the risk of malignancy (ROM) of each The Bethesda System for Reporting Thyroid Cytopathology (TBSRTC) category were calculated in the 2 groups (ROSE and non-ROSE) and compared using the chi-square test. RESULTS: An initial search obtained 4649 cytology specimens, 3469 of which (74.6%) underwent ROSE and 1180 of which (25.4%) did not. Patients were predominantly female (85.4%), with a mean age of 53 years. Specimen adequacy was found to be significantly higher in the ROSE group (93.4% vs 69.4%; P<.0001), with a mean number of needle passes necessary for an adequate diagnosis of 1.48 ± 0.71 (median, 1.0 needle passes; range, 1-5 needle passes). No statistical difference was observed with regard to the ROM for each TBSRTC category when the 2 groups (ROSE and non-ROSE) were compared. CONCLUSIONS: The current study data support ROSE as a valuable technique in thyroid FNAB. It was proven to significantly improve specimen adequacy with a decreased mean number of needle passes necessary to achieve an adequate cytological diagnosis and no impact on the ROM for any TBSRTC category.


Assuntos
Citodiagnóstico/métodos , Biópsia Guiada por Imagem/métodos , Glândula Tireoide/patologia , Neoplasias da Glândula Tireoide/patologia , Nódulo da Glândula Tireoide/patologia , Biópsia por Agulha Fina , Estudos de Avaliação como Assunto , Feminino , Seguimentos , Humanos , Masculino , Pessoa de Meia-Idade , Prognóstico , Estudos Retrospectivos , Glândula Tireoide/diagnóstico por imagem , Glândula Tireoide/cirurgia , Neoplasias da Glândula Tireoide/diagnóstico por imagem , Neoplasias da Glândula Tireoide/cirurgia , Nódulo da Glândula Tireoide/diagnóstico por imagem , Nódulo da Glândula Tireoide/cirurgia , Ultrassonografia
3.
Cancer Cytopathol ; 125(S6): 455-464, 2017 Jun.
Artigo em Inglês | MEDLINE | ID: mdl-28609003

RESUMO

With increasing requests for the evaluation of prognostic and predictive molecular biomarkers, great attention must be paid to the preanalytical issues regarding sample quality and DNA/RNA yield from all different types of cytological preparations. The objectives of this review were: 1) to provide an update regarding the importance of specimen triage as well as specimen handling and collection; 2) to discuss the different cell preparations that can be used for molecular testing, their advantages and limitations; and 3) to highlight the strategies for biobanking cytology samples. Good-quality DNA/RNA can be harvested from fresh cells in cell suspensions, formalin-fixed paraffin-embedded cell blocks, archival stained smears, archival unstained cytospin preparations, liquid-based cytology slides, FTA cards, and cryopreserved cells. In contrast to formalin-fixed paraffin-embedded tissue specimens (small biopsies and surgical resections), the multitude of types of sample preparations as well as the diversity in sample collection and processing procedures make cytology an ideal specimen for most genomic platforms, with less DNA and RNA degradation and a purer sample, usually with a higher concentration of tumor cells. The broad incorporation of cytological specimens into clinical practice. A should increase the number of samples potentially available for molecular tests and avoid repeat invasive procedures for tissue procurement, thereby increasing patient safety. In this context, it is of utmost importance that cytopathologists become familiar with the variables that can affect test results and embrace the goal of excellence in sample quality. Cancer Cytopathol 2017;125(6 suppl):455-64. © 2017 American Cancer Society.


Assuntos
Técnicas de Diagnóstico Molecular/métodos , Neoplasias/genética , Manejo de Espécimes/métodos , Biópsia/métodos , Criopreservação , Humanos , Neoplasias/diagnóstico , Neoplasias/metabolismo , Neoplasias/patologia , Teste de Papanicolaou , Inclusão em Parafina , Análise de Sequência de DNA , Análise de Sequência de RNA , Triagem
4.
J Thorac Oncol ; 7(10): 1513-21, 2012 Oct.
Artigo em Inglês | MEDLINE | ID: mdl-22982652

RESUMO

INTRODUCTION: Phosphatase and tensin homolog (PTEN) has been established as a tumor suppressor gene with an important role in regulating the phosphatidylinositol-3-kinase/AKT antiapoptotic and survival pathway. The prognostic role of PTEN in non-small-cell lung carcinoma has not been evaluated completely in the context of other molecular information. METHODS: Tissue microarrays containing 152 resected non-small-cell lung cancer specimens were used to investigate PTEN and p53 by immunohistochemistry and PTEN by fluorescence in situ hybridization. DNA was isolated and subjected to mutational profiling using the Sequenom Oncocarta v1.0 panel. Clinicopathological features were correlated with PTEN expression, gene copy number, and mutation status. RESULTS: PTEN staining was absent in 63 (41.4%) of the cases. Significantly more squamous cell carcinomas compared with adenocarcinomas demonstrated loss of (negative) PTEN staining (26 of 44 [59%] versus 32 of 94 [34%]; p = 0.009). PTEN gene copy deletion was present in only seven of 124 evaluable cases (5.6%); all deleted cases were immunohistochemistry negative. In univariate and multivariate (MV) analyses adjusted for sex, age, histology, and stage, loss of PTEN protein expression was associated with significantly shorter disease-free survival (MV hazard ratio: 1.78, 95% confidence interval: 1.01-3.14, p = 0.048), whereas no significant associations were seen with p53 or KRAS and epidermal growth factor receptor (EGFR) mutation status. Importantly, the prognostic value of absent PTEN staining was limited to adenocarcinomas, with MV disease-free survival hazard ratio of 2.68 (95% confidence interval: 1.35-5.32, p = 0.005), whereas no such association was seen in squamous cell carcinomas. CONCLUSION: Absence of PTEN protein expression is an independent prognostic marker in early-stage resected lung adenocarcinoma.


Assuntos
Adenocarcinoma/mortalidade , Carcinoma Pulmonar de Células não Pequenas/mortalidade , Carcinoma de Células Escamosas/mortalidade , Neoplasias Pulmonares/mortalidade , PTEN Fosfo-Hidrolase/genética , Adenocarcinoma/genética , Adenocarcinoma/metabolismo , Adulto , Idoso , Idoso de 80 Anos ou mais , Carcinoma Pulmonar de Células não Pequenas/genética , Carcinoma Pulmonar de Células não Pequenas/metabolismo , Carcinoma de Células Escamosas/genética , Carcinoma de Células Escamosas/metabolismo , Receptores ErbB/genética , Feminino , Seguimentos , Dosagem de Genes , Humanos , Técnicas Imunoenzimáticas , Hibridização in Situ Fluorescente , Neoplasias Pulmonares/genética , Neoplasias Pulmonares/metabolismo , Masculino , Pessoa de Meia-Idade , Mutação/genética , Estadiamento de Neoplasias , Prognóstico , Proteínas Proto-Oncogênicas/genética , Proteínas Proto-Oncogênicas p21(ras) , Taxa de Sobrevida , Análise Serial de Tecidos , Proteína Supressora de Tumor p53/genética , Proteínas ras/genética
SELEÇÃO DE REFERÊNCIAS
DETALHE DA PESQUISA