RESUMO
OBJECTIVES: Blood-oxygen-level-dependent (BOLD) magnetic resonance imaging (MRI) facilitates the non-invasive in-vivo evaluation of placental oxygenation. The aims of this study were to identify and quantify a relative BOLD effect in response to hyperoxia in the human placenta and to compare it between pregnancies with and those without fetal growth restriction (FGR). METHODS: This was a prospective multicenter study (NCT02238301) of 19 pregnancies with FGR (estimated fetal weight (EFW) on ultrasound < 5th centile) and 75 non-FGR pregnancies (controls) recruited at two centers in Paris, France. Using a 1.5-Tesla MRI system, the same multi-echo gradient-recalled echo (GRE) sequences were performed at both centers to obtain placental T2* values at baseline and in hyperoxic conditions. The relative BOLD effect was calculated according to the equation 100 × (hyperoxic T2* - baseline T2*)/baseline T2*. Baseline T2* values and relative BOLD effect were compared according to EFW (FGR vs non-FGR), presence/absence of Doppler anomalies and birth weight (small-for-gestational age (SGA) vs non-SGA). RESULTS: We observed a relative BOLD effect in response to hyperoxia in the human placenta (median, 33.8% (interquartile range (IQR), 22.5-48.0%)). The relative BOLD effect did not differ significantly between pregnancies with and those without FGR (median, 34.4% (IQR, 24.1-48.5%) vs 33.7% (22.7-47.4%); P = 0.95). Baseline T2* Z-score adjusted for gestational age at MRI was significantly lower in FGR pregnancies compared with non-FGR pregnancies (median, -1.27 (IQR, -4.87 to -0.10) vs 0.33 (IQR, -0.81 to 1.02); P = 0.001). Baseline T2* Z-score was also significantly lower in those pregnancies that subsequently delivered a SGA neonate (n = 23) compared with those that delivered a non-SGA neonate (n = 62) (median, -0.75 (IQR, -3.48 to 0.29) vs 0.35 (IQR, -0.79 to 1.05); P = 0.01). CONCLUSIONS: Our study confirms a BOLD effect in the human placenta and that baseline T2* values are significantly lower in pregnancies with FGR. Further studies are needed to evaluate whether such parameters may detect placental insufficiency before it has a clinical impact on fetal growth. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
Assuntos
Hiperóxia , Placenta , Recém-Nascido , Gravidez , Feminino , Humanos , Placenta/diagnóstico por imagem , Estudos Prospectivos , Retardo do Crescimento Fetal/diagnóstico por imagem , Recém-Nascido Pequeno para a Idade Gestacional , Peso Fetal , Idade Gestacional , Ultrassonografia Pré-Natal/métodosRESUMO
OBJECTIVES: It has been suggested previously that the presence of Probst bundles (PB) in cases with a short corpus callosum (SCC) on diffusion tensor imaging (DTI) may help to differentiate between corpus callosal (CC) dysplasia and a variant of normal CC development. The objectives of this study were to compare DTI parameters between cases of SCC vs normal CC and between cases of SCC with PB (SCC-PB+) vs SCC without PB (SCC-PB-). METHODS: This was a retrospective study of patients referred to the Necker Hospital in Paris, France, for magnetic resonance imaging (MRI) evaluation of an apparently isolated SCC detected by sonography between November 2016 and December 2022 (IRB: 00011928). MRI was performed using a 1.5-Tesla Signa system. T2-weighted axial and sagittal sequences of the fetal brain were used to measure the length and thickness of the CC. 16-direction DTI axial brain sequences were performed to identify the presence of PB and to generate quantitative imaging parameters (fractional anisotropy (FA) and apparent diffusion coefficient (ADC)) of the entire CC, genu, body and splenium. Cases in which other associated brain abnormalities were detected on MRI were excluded. Cases were matched for fetal gender and gestational age with controls in a 1:3 ratio. Control cases were normal fetuses included in the LUMIERE on the FETUS trial (NCT04142606) that underwent the same DTI evaluation of the brain. Comparisons between SCC and normal CC cases, and between SCC-PB+ and SCC-PB- cases were performed using ANOVA and adjusted for potential confounders using ANCOVA. RESULTS: Twenty-two SCC cases were included and compared with 66 fetuses with a normal CC. In 10/22 (45.5%) cases of SCC, PB were identified. As expected, dimensions of the CC were significantly smaller in SCC compared with normal CC cases (all P < 0.01). In SCC-PB+ vs SCC-PB- cases, FA values were significantly lower in the entire CC (median, 0.21 (range, 0.19-0.24) vs 0.24 (range, 0.22-0.28); P < 0.01), genu (median, 0.21 (range, 0.15-0.29) vs 0.24 (range, 0.17-0.29); P = 0.04), body (median, 0.21 (range, 0.18-0.23) vs 0.23 (range, 0.21-0.27); P = 0.04) and splenium (median, 0.22 (range, 0.16-0.30) vs 0.25 (range, 0.20-0.29); P = 0.03). ADC values were significantly higher in the entire CC, genu and body in SCC-PB+ vs SCC-PB- cases (all P < 0.05). In SCC-PB+ cases, all FA values were significantly lower, and ADC values in the CC body were significantly higher compared with normal CC cases (all P < 0.05). In SCC-PB- cases, there was no significant difference in FA and ADC compared with normal CC cases (all P > 0.05). CONCLUSIONS: Fetal DTI evaluation of the CC showed that FA values were significantly lower and ADC values tended to be significantly higher in SCC-PB+ compared with normal CC cases. This may highlight alterations of the white matter microstructure in SCC-PB+. In contrast, isolated SCC-PB- did not demonstrate significant changes in DTI parameters, strengthening the possibility that this is a normal CC variant. © 2023 International Society of Ultrasound in Obstetrics and Gynecology.
Assuntos
Corpo Caloso , Imagem de Tensor de Difusão , Feminino , Humanos , Gravidez , Corpo Caloso/diagnóstico por imagem , Imageamento por Ressonância Magnética , Cuidado Pré-Natal , Estudos Retrospectivos , Ensaios Clínicos como AssuntoRESUMO
OBJECTIVES: T2*-weighted magnetic resonance imaging (MRI) sequences have been identified as non-invasive tools with which to study placental oxygenation in vivo. This study aimed to use these to investigate both static and dynamic responses to hyperoxia of the normal placenta across gestation. METHODS: We conducted a single-center prospective study including 52 uncomplicated pregnancies. Two T2*-weighted sequences (T2* relaxometry) were performed, one before and one after maternal hyperoxia. The distribution of placental T2* values was modeled by fitting a gamma probability density function (T2* ~ Γ α ß ), describing the structure of the histogram using the mean T2* value, the shape parameter (α) and the rate (ß). A dynamic acquisition (blood-oxygen-level-dependent (BOLD) MRI) was also performed before and during maternal oxygen supply, until placental oxygen saturation had been achieved. The signal change over time was modeled using a sigmoid function, to determine the intensity of enhancement (ΔBOLD (% with respect to baseline)), a temporal variation coefficient (λ (min-1), controlling the slope of the curve) and the maximum steepness (Vmax (% of placental enhancement/min)). RESULTS: The histogram analysis of the T2* values in normoxia showed a whole-placenta variation, with a decreasing linear trend in the mean T2* value (Pearson's correlation coefficient (R) = -0.83 (95% CI, -0.9 to -0.71), P < 0.001), along with an increasingly peaked and narrower distribution of T2* values with advancing gestation. After maternal hyperoxia, the mean T2* ratios (mean T2*hyperoxia/mean T2*baseline) were positively correlated with gestational age, while the other histogram parameters remained stable, suggesting a translation of the histogram towards higher values with a similar appearance after maternal hyperoxia. ΔBOLD showed a non-linear increase across gestation. Conversely, λ showed an inverted trend across gestation, with a weaker correlation (R = -0.33 (95% CI, -0.58 to -0.02), P = 0.04, R2 = 0.1). As a combination of ΔBOLD and λ, the changes in Vmax throughout gestation were influenced mainly by the changes in ΔBOLD and showed a positive non-linear correlation with gestational age. CONCLUSIONS: Our results suggest that the decrease in the T2* placental signal as gestation progresses does not reflect placental dysfunction. The BOLD dynamic signal change is representative of a free-diffusion model of oxygenation and highlights the increasing differences in oxygen saturation between mother and fetus as gestation progresses (ΔBOLD) and in the placental permeability to oxygen (λ). © 2024 International Society of Ultrasound in Obstetrics and Gynecology.
Assuntos
Hiperóxia , Imageamento por Ressonância Magnética , Placenta , Humanos , Feminino , Gravidez , Placenta/diagnóstico por imagem , Placenta/metabolismo , Hiperóxia/diagnóstico por imagem , Imageamento por Ressonância Magnética/métodos , Estudos Prospectivos , Adulto , Idade Gestacional , Oxigênio/metabolismoRESUMO
OBJECTIVE: To report our experience of fetal aortic valvuloplasty (FAV) for critical aortic stenosis (AS), with a focus on the postnatal evolution of the patients. METHODS: This was a retrospective study including all fetuses with critical AS which underwent FAV in a single center between January 2011 and June 2022. FAV was performed under ultrasound guidance. Technical success was based upon balloon inflation across the aortic valve and improvement of the antegrade aortic flow across the aortic valve. At birth, a biventricular circulation (BVC) strategy was decided assuming the left ventricular (LV) systolic and diastolic function would ensure the systemic circulation. RESULTS: Sixty-three FAV procedures were performed in 58 fetuses, at a median (range) gestational age of 26.2 (20.3-32.2) weeks. The procedure was technically successful in 50/58 (86.2%) fetuses. There were 11/58 (19.0%) cases of in-utero demise and 9/58 (15.5%) terminations of pregnancy. No patient was liveborn after an unsuccessful procedure. Thirty-eight (65.5%) infants were liveborn, at a median (range) gestational age of 38.1 (29.0-40.6) weeks, of whom 21 (55.3%) required prostaglandin treatment. Twenty-eight of the 38 (73.7%) liveborn children (48.3% of the study population) entered the BVC pathway at birth. Among them, 20 (71.4%) required an aortic valvuloplasty procedure at birth (11 (55.0%) percutaneous balloon, nine (45.0%) surgical) and eight (28.6%) did not require any treatment at birth, but, of these, five (62.5%) underwent surgical valvuloplasty between day 26 and day 1200 of age. Eleven (39.3%) of the infants with BVC at birth required a second intervention and four (14.3%) of them required a third intervention. Two (7.1%) infants who entered the BVC pathway at birth underwent conversion to univentricular circulation (UVC). None of the surviving children with BVC developed pulmonary hypertension. The overall survival rate in those with BVC at birth was 22/28 (78.6%) at a median (range) follow-up of 23.3 (2.0-112.6) months. Ten of the 58 (17.2%) patients had UVC at birth. Among these, six (60.0%) received compassionate care from birth and four (40.0%) underwent surgery. Three of the 10 patients who had UVC at birth were still alive at the latest follow-up assessment, at a median (range) gestational age of 24.3 (8.3-48.7) months. CONCLUSIONS: FAV for critical AS led to increase of antegrade aortic flow in 86.2% of fetuses, with BVC being achieved in 48.3% (73.7% of the liveborn cases). Among patients with BVC at birth, the rate of reintervention was high, but 78.6% of these children were alive at the latest evaluation. © 2024 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
Assuntos
Estenose da Valva Aórtica , Valvuloplastia com Balão , Idade Gestacional , Ultrassonografia Pré-Natal , Humanos , Feminino , Estudos Retrospectivos , Estenose da Valva Aórtica/cirurgia , Estenose da Valva Aórtica/embriologia , Estenose da Valva Aórtica/diagnóstico por imagem , Gravidez , Valvuloplastia com Balão/métodos , Recém-Nascido , Resultado do Tratamento , Valva Aórtica/diagnóstico por imagem , Valva Aórtica/cirurgia , Valva Aórtica/embriologia , Doenças Fetais/terapia , Doenças Fetais/cirurgiaRESUMO
OBJECTIVE: To identify prenatal predictors of poor perinatal outcome in fetuses with isolated sacrococcygeal teratoma (SCT). METHODS: This was a retrospective study of fetuses with isolated (non-syndromic) SCT managed at one of five pediatric surgery and/or fetal medicine centers between January 2007 and December 2017. The primary outcome was the occurrence of poor perinatal outcome, defined as prenatal death (including termination), or neonatal death or severe compromise (hemorrhagic shock). Data regarding prenatal diagnosis (sonographic features both at referral and at the last ultrasound examination before pregnancy outcome, assessment of SCT growth velocity), perinatal complications and outcome, and neonatal course were analyzed to determine prenatal SCT characteristics associated with adverse perinatal outcome. RESULTS: Fifty-five fetuses were included, diagnosed with isolated SCT at a median gestational age of 22 (interquartile range, 18-23) weeks. There was a poor perinatal outcome in 31% (n = 17) of these cases, including intrauterine fetal demise (4%, n = 2), pregnancy termination (13%, n = 7) and neonatal severe compromise (15%, n = 8), leading to neonatal death in five cases. The overall survival rate after prenatal diagnosis of isolated SCT was 75% (n = 41 of 55). Earlier gestational age at diagnosis (P = 0.02), large tumor volume at referral (P < 0.001), presence of one or more hemodynamic complications (P = 0.02), fast tumor growth velocity (P < 0.001) and high tumor grade (highest tumor grade ≥ 3) (P = 0.049) were associated with poor perinatal outcome on univariate analysis. On stepwise logistic regression analysis, tumor growth velocity was the only remaining independent factor associated with poor perinatal outcome (odds ratio (OR) (per 1-mm/week increase), 1.48 (95% CI, 1.22-1.97), P = 0.001). The best predictive cut-off of tumor growth velocity for poor perinatal outcome was 7 mm/week (OR, 25.7 (95% CI, 5.6-191.3), P < 0.001), yielding a sensitivity of 88% and a specificity of 77%. CONCLUSIONS: Approximately 30% of fetuses with a diagnosis of isolated SCT have poor perinatal outcome. Tumor growth velocity ≥ 7 mm/week appears to be an appropriate discriminative cut-off for poor perinatal outcome. These results could help to inform prenatal management and counseling of parents with an affected pregnancy. © 2024 The Author(s). Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
Assuntos
Idade Gestacional , Região Sacrococcígea , Teratoma , Ultrassonografia Pré-Natal , Humanos , Feminino , Teratoma/diagnóstico por imagem , Teratoma/embriologia , Teratoma/mortalidade , Gravidez , Estudos Retrospectivos , Região Sacrococcígea/diagnóstico por imagem , Região Sacrococcígea/embriologia , Recém-Nascido , Adulto , Resultado da Gravidez , Morte Fetal/etiologia , Mortalidade Perinatal , Morte Perinatal , Doenças Fetais/diagnóstico por imagem , Doenças Fetais/mortalidadeRESUMO
OBJECTIVES: Diffusion tensor imaging (DTI) of the fetal brain is a relatively new technique that allows evaluation of white matter tracts of the central nervous system throughout pregnancy, as well as in certain pathological conditions. The objectives of this study were to evaluate the feasibility of DTI of the spinal cord in utero and to examine gestational-age (GA)-related changes in DTI parameters during pregnancy. METHODS: This was a prospective study conducted between December 2021 and June 2022 in the LUMIERE Platform, Necker-Enfants Malades Hospital, Paris, France, as part of the LUMIERE SUR LE FETUS trial. Women with a pregnancy between 18 and 36 weeks of gestation without fetal or maternal abnormality were eligible for inclusion. Sagittal diffusion-weighted scans of the fetal spine were acquired, without sedation, using a 1.5-Tesla magnetic resonance imaging scanner. The imaging parameters were as follows: 15 non-collinear direction diffusion-weighted magnetic-pulsed gradients with a b-value 700 s/mm2 and one B0 image without diffusion-weighting; slice thickness, 3 mm; field of view (FOV), 36 mm; phase FOV, 1.00; voxel size, 4.5 × 2.8 × 3 mm3 ; number of slices, 7-10; repetition time, 2800 ms; echo time, minimum; and total acquisition time, 2.3 min. DTI parameters, including fractional anisotropy (FA) and apparent diffusion coefficient (ADC), were extracted at the cervical, upper thoracic, lower thoracic and lumbar levels of the spinal cord. Cases with motion degradation and those with aberrant reconstruction of the spinal cord on tractography were excluded. Pearson's correlation analysis was performed to evaluate GA-related changes of DTI parameters during pregnancy. RESULTS: During the study period, 42 pregnant women were included at a median GA of 29.3 (range, 22.0-35.7) weeks. Five (11.9%) patients were not included in the analysis because of fetal movement. Two (4.8%) patients with aberrant tractography reconstruction were also excluded from analysis. Acquisition of DTI parameters was feasible in all remaining cases (35/35). Increasing GA correlated with increasing FA averaged over the entire fetal spinal cord (r, 0.37; P < 0.01), as well as at the individual cervical (r, 0.519; P < 0.01), upper thoracic (r, 0.468; P < 0.01), lower thoracic (r, 0.425; P = 0.02) and lumbar (r, 0.427; P = 0.02) levels. There was no correlation between GA and ADC averaged over the entire spinal cord (r, 0.01; P = 0.99) or at the individual cervical (r, -0.109; P = 0.56), upper thoracic (r, -0.226; P = 0.22), lower thoracic (r, -0.052; P = 0.78) or lumbar (r, -0.11; P = 0.95) levels. CONCLUSIONS: This study shows that DTI of the spinal cord is feasible in normal fetuses in typical clinical practice and allows extraction of DTI parameters of the spinal cord. There is a significant GA-related change in FA in the fetal spinal cord during pregnancy, which may result from decreasing water content as observed during myelination of fiber tracts occurring in utero. This study may serve as a basis for further investigation of DTI in the fetus, including research into its potential in pathological conditions that impact spinal cord development. © 2023 International Society of Ultrasound in Obstetrics and Gynecology.
Assuntos
Imagem de Tensor de Difusão , Substância Branca , Humanos , Feminino , Gravidez , Imagem de Tensor de Difusão/métodos , Estudos Prospectivos , Estudos de Viabilidade , Medula Espinal/diagnóstico por imagem , Medula Espinal/patologiaRESUMO
OBJECTIVE: Adequate reference ranges of size of the corpus callosum (CC) are necessary to improve characterization of CC abnormalities and parental counseling. The objective of this study was to evaluate the methodology used in studies developing references charts for CC biometry. METHODS: We conducted a systematic review of studies on fetal CC biometry using a set of predefined quality criteria of study design, statistical analysis and reporting methods. We included observational studies whose primary aim was to create ultrasound or magnetic resonance imaging charts for CC size in a normal population of fetuses. Studies were scored against a predefined set of independently agreed methodological criteria, and an overall quality score was given for each study. RESULTS: Twelve studies met the inclusion criteria. Quality scores ranged between 17.4% and 95.7%. The greatest potential for bias was noted for the following items: sample selection and sample-size calculation, as only 17% of the studies were population-based and had consecutive or random recruitment of patients and with a justification of the sample size; number of measurements obtained for CC biometry, as only 17% of the studies performed more than one measurement per fetus and per scan; and description of characteristics of the study population, as only 8% of the studies clearly reported a minimum dataset of demographic characteristics. CONCLUSIONS: Our review demonstrates substantial heterogeneity in methods and final biometric values of the fetal CC across the evaluated studies. The use of uniform methodology of the highest quality is essential in order to define a 'short' CC and provide appropriate parental counseling. © 2023 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
Assuntos
Corpo Caloso , Ultrassonografia Pré-Natal , Gravidez , Feminino , Humanos , Corpo Caloso/diagnóstico por imagem , Idade Gestacional , Ultrassonografia Pré-Natal/métodos , Valores de Referência , Biometria/métodos , Feto/diagnóstico por imagemRESUMO
OBJECTIVES: The performance of non-invasive prenatal screening using cell-free DNA testing in maternal blood in twin pregnancies is still under-evaluated, while serum marker-based strategies yield poor results. This study aims at assessing the performance of non-invasive prenatal screening for trisomy 21 in twin pregnancies as a first-tier test. The secondary objectives were to assess the failure rate and associated factors. METHODS: This retrospective cohort study included twin pregnancies for which non-invasive prenatal screening using cell-free DNA was performed as the primary screening strategy between May 2017 and October 2019. We used the NIPT VeriSeq® test for in vitro diagnosis and set a fetal fraction cut-off of 4% for monochorionic pregnancies and 8% for dichorionic ones. Clinical data and pregnancy outcome was collected from either physicians or midwives through a questionnaire or were retrieved directly on site. We calculated the performance of non-invasive cell free DNA screening for trisomy 21 and analyzed failure rate and factors. RESULTS: We included 2577 multiple pregnancies among which 1885 (84.8%) were retained after excluding vanishing twins and pregnancies without follow-up. Overall, there were six confirmed trisomy 21 cases (0.32%). For trisomy 21, sensitivity was 100% (95% CI, 61-100%) and the false-positive rate 0.2% (95% CI, 0.07-0.6%). The primary failure rate was 4.6% with 4% due to insufficient fetal fraction. After a new blood draw (59.8% of failed cases), failure rate was only 1.5%. Body mass index and chorionicity were significantly correlated with the risk of failure. CONCLUSION: This study adds further evidence on the high performance of NIPS in twins, as part of the primary screening strategy for trisomy 21, at an extremely low false-positive rate. This article is protected by copyright. All rights reserved.
RESUMO
Human brain development is a complex process that begins in the third week of gestation. During early development, the fetal brain undergoes dynamic morphological changes. These changes result from events such as neurogenesis, neuronal migration, synapse formation, axonal growth and myelination. Disruption of any of these processes is thought to be responsible for a wide array of different pathologies. Recent advances in magnetic resonance imaging, especially diffusion-weighted imaging and diffusion tensor imaging (DTI), have enabled characterization and evaluation of brain development in utero. In this review, aimed at practitioners involved in fetal medicine and high-risk pregnancies, we provide a comprehensive overview of fetal DTI studies focusing on characterization of early normal brain development as well as evaluation of brain pathology in utero. We also discuss the reliability and limitations of fetal brain DTI. © 2022 International Society of Ultrasound in Obstetrics and Gynecology.
Assuntos
Encéfalo , Imagem de Tensor de Difusão , Encéfalo/diagnóstico por imagem , Imagem de Difusão por Ressonância Magnética , Imagem de Tensor de Difusão/métodos , Feminino , Humanos , Imageamento por Ressonância Magnética , Gravidez , Reprodutibilidade dos TestesRESUMO
OBJECTIVE: To evaluate the postnatal outcome of children with a prenatal diagnosis of apparently isolated agenesis of the septum pellucidum (ASP). METHODS: A retrospective cohort study of cases of prenatally diagnosed ASP followed in two tertiary centers and a meta-analysis combining data from the cohort study with data from published studies identified in a systematic review were carried out. Only cases with apparently isolated ASP on antenatal ultrasound and/or magnetic resonance imaging and with available postnatal follow-up data were considered eligible for inclusion. The following outcomes were analyzed: incidence of chromosomal anomalies, agreement between antenatal and postnatal findings, overall incidence of septo-optic dysplasia (SOD) and incidence of major neurological disability (motor, language, coordination or behavioral disorder or epilepsy) in non-SOD children. The incidence of SOD in infants with apparently normal optic pathways on antenatal imaging was also evaluated. RESULTS: Fifteen cases of isolated ASP, with median postnatal follow-up of 36 months (range, 12-60 months), were selected from the two centers. Six previously published studies met the inclusion criteria for the systematic review and a total of 78 cases were eligible for the analysis, including the 15 cases from our series. Genetic tests were carried out antenatally in 30 fetuses, of which two had an abnormal result (pooled proportion, 9.0% (95% CI, 1.8-20.7%); I2 = 0%). Additional or discordant imaging findings were noted postnatally in 9/70 (pooled proportion, 13.7% (95% CI, 3.5-29.0%); I2 = 63.9%) cases. Of all 78 neonates with available follow-up, SOD was diagnosed postnatally in 14 (pooled proportion, 19.4% (95% CI, 8.6-33.2%); I2 = 51.2%). In 60 cases, the optic pathways were considered to be normal on antenatal imaging, and six of these (pooled proportion, 9.1% (95% CI, 1.1-24.0%); I2 = 62.0%) were diagnosed postnatally with SOD. Of the 46 infants with available neurological follow-up who were not affected by SOD, a major neurological disability was diagnosed in three (pooled proportion, 6.5% (95% CI, 0.5-18.6%); I2 = 40.1%). CONCLUSIONS: In the vast majority of cases with a prenatal diagnosis of apparently isolated ASP, the prognosis is favorable. However, an additional anomaly is detected after birth in about 14% of cases and has a negative impact on clinical outcome. Detailed antenatal assessment of the brain and optic pathways is strongly recommended in order to identify the presence of associated anomalies. Antenatal visualization of apparently normal optic pathways does not rule out SOD. © 2021 International Society of Ultrasound in Obstetrics and Gynecology.
Assuntos
Diagnóstico Pré-Natal/métodos , Displasia Septo-Óptica/diagnóstico por imagem , Septo Pelúcido/anormalidades , Septo Pelúcido/diagnóstico por imagem , Estudos de Coortes , Feminino , Feto/diagnóstico por imagem , Humanos , Gravidez , Displasia Septo-Óptica/patologia , Ultrassonografia Pré-NatalRESUMO
OBJECTIVE: To evaluate the feasibility of amplification of the viral genome by polymerase chain reaction (PCR) analysis of trophoblast samples obtained by chorionic villus sampling (CVS) in cases of maternal primary infection (MPI) with cytomegalovirus (CMV) in early pregnancy. METHODS: This was a prospective study carried out at the Department of Obstetrics and Fetal Medicine, Hopital Necker-E.M., between October 2019 and October 2020. Following CMV serology screening in early pregnancy, CVS was offered to women at 11-14 weeks' gestation after CMV-MPI ≤ 10 weeks. Array-comparative genomic hybridization and amplification of the viral genome by PCR were performed on the trophoblasts obtained by CVS. All cases also underwent amniocentesis from 17 weeks onwards and PCR was performed on the amniotic fluid. Secondary prevention with valacyclovir was initiated as soon as MPI was diagnosed, to decrease the risk of vertical transmission. We evaluated the diagnostic performance of CMV-PCR of trophoblast obtained by CVS, using as the reference standard PCR of amniotic fluid obtained by amniocentesis. RESULTS: CVS was performed in 37 pregnancies, at a median (range) gestational age of 12.7 (11.3-14.4) weeks. CMV-PCR in chorionic villi was positive in three and negative in 34 cases. CMV-PCR following amniocentesis, performed at a median (range) gestational age of 17.6 (16.7-29.9) weeks, was positive for the three cases which were positive following CVS and, of the 34 patients with a negative finding following CVS, amniocentesis was negative in 31 and positive in three. The sensitivity of CMV-PCR analysis of trophoblast obtained by CVS for the diagnosis of CMV, using as the reference standard PCR analysis of amniotic fluid obtained by amniocentesis, was 50% (95% CI, 19-81%), specificity was 100% (95% CI, 89-100%), positive predictive value was 100% (95% CI, 44-100%) and negative predictive value was 91% (95% CI, 77-97%). CONCLUSIONS: Diagnosis of placental infection following MPI in early pregnancy can be achieved by PCR amplification of the CMV genome in chorionic villi. We propose that negative CMV-PCR in the trophoblast after 12 weeks could be used to exclude CMV-related embryopathy leading to sequelae. However, this needs to be confirmed through long-term follow-up evaluation. These findings could help to establish CVS as the diagnostic test of choice following maternal serology screening in early pregnancy. © 2021 International Society of Ultrasound in Obstetrics and Gynecology.
Assuntos
Infecções por Citomegalovirus/diagnóstico , Citomegalovirus/isolamento & purificação , Genoma Viral , Reação em Cadeia da Polimerase/métodos , Complicações Infecciosas na Gravidez/diagnóstico , Diagnóstico Pré-Natal/métodos , Adulto , Amniocentese , Líquido Amniótico/virologia , Vilosidades Coriônicas/virologia , Amostra da Vilosidade Coriônica/métodos , Infecções por Citomegalovirus/embriologia , Infecções por Citomegalovirus/transmissão , Estudos de Viabilidade , Feminino , Idade Gestacional , Humanos , Transmissão Vertical de Doenças Infecciosas/prevenção & controle , Gravidez , Complicações Infecciosas na Gravidez/virologia , Primeiro Trimestre da Gravidez , Estudos Prospectivos , Valores de Referência , Sensibilidade e EspecificidadeRESUMO
OBJECTIVE: Fetal anomalies of the corpus callosum (CC) have been reported in the prenatal imaging literature since 1985, and, especially when isolated, pose challenges for both the patient and fetal medicine specialist. The purpose of this study was to review systematically the literature on prenatally diagnosed abnormalities of the CC, focusing on the terminology used to describe abnormalities other than complete agenesis of the CC, and to assess the heterogeneity of the nomenclature and definitions used. METHODS: This study was conducted in accordance with the PRISMA statement for reporting systematic reviews. A literature search was performed to identify prospective or retrospective case series or cohort studies, published in English, French, Italian, German or Spanish, reporting fetal imaging findings and describing anomalies of the CC. Quality and risk of bias of the studies were evaluated using the Newcastle-Ottawa scale and a modification of the scale developed by Conde-Agudelo et al. for other fetal imaging studies. The data extracted included the number of patients, the number of different anomalies identified, the descriptive names of the anomalies, and, where applicable, the definitions of the anomalies, the number of cases of each type of anomaly and the biometric charts used. Secondary tests used to confirm the diagnosis, as well as the postnatal or post-termination tests used to ascertain the diagnosis, were also recorded. RESULTS: The search identified 998 records, and, after review of titles and abstracts and full review of 45 papers, 27 studies were included initially in the review, of which 24 were included in the final analysis. These 24 studies had a broad range of quality and risk of bias and represented 1135 cases of CC anomalies, of which 49% were complete agenesis and the remainder were described using the term partial agenesis or nine other terms, of which five had more than one definition. CONCLUSIONS: In comparison to the postnatal literature, in the prenatal literature there is much greater heterogeneity in the nomenclature and definition of CC anomalies other than complete agenesis. This heterogeneity and lack of standard definitions in the prenatal literature make it difficult to develop large multicenter pooled cohorts of patients who can be followed in order to develop a better understanding of the genetic associations and neurodevelopmental and psychological outcomes of patients with CC anomalies. As this information is important to improve counseling of these patients, a good first step towards this goal would be to develop a simpler categorization of prenatal CC anomalies that matches better the postnatal literature. © 2020 International Society of Ultrasound in Obstetrics and Gynecology.
Assuntos
Agenesia do Corpo Caloso/embriologia , Corpo Caloso/embriologia , Feto/diagnóstico por imagem , Diagnóstico Pré-Natal , Terminologia como Assunto , Agenesia do Corpo Caloso/diagnóstico por imagem , Corpo Caloso/diagnóstico por imagem , Feminino , Feto/embriologia , Humanos , Gravidez , Estudos Prospectivos , Estudos RetrospectivosRESUMO
OBJECTIVE: To report the outcome of fetuses with congenital cytomegalovirus (CMV) infection and normal ultrasound at the time of diagnosis, and to evaluate the rate of an additional anomaly detected only on magnetic resonance imaging (MRI). METHODS: Medline, EMBASE, CINAHL and Cochrane databases were searched for studies reporting on the outcome of fetuses with congenital CMV infection. Inclusion criteria were fetuses with confirmed CMV infection and normal ultrasound assessment at the time of the initial evaluation. The outcomes observed were an anomaly detected on a follow-up ultrasound scan, an anomaly detected on prenatal MRI but missed on ultrasound, an anomaly detected on postnatal assessment but missed prenatally, perinatal mortality, symptomatic infection at birth, neurodevelopmental outcome and hearing and visual deficits. Neurodevelopmental outcome was assessed only in cases of isolated CMV infection confirmed at birth. Subgroup analysis was performed according to the trimester in which maternal infection occurred. Random-effects meta-analysis of proportions was used to analyze the data. RESULTS: Twenty-six studies were included, comprising 2603 fetuses with congenital CMV infection, of which 1178 (45.3%) had normal ultrasound at the time of diagnosis and were included in the analysis. The overall rate of an associated central nervous system (CNS) anomaly detected on a follow-up ultrasound scan was 4.4% (95% CI, 1.4-8.8%) (32/523; 15 studies), while the rates of those detected exclusively on prenatal MRI or on postnatal imaging were 5.8% (95% CI, 1.9-11.5%) (19/357; 11 studies) and 3.2% (95% CI, 0.3-9.0%) (50/660; 17 studies), respectively. The rate of an associated extra-CNS anomaly detected on a follow-up ultrasound scan was 2.9% (95% CI, 0.8-6.3%) (19/523; 15 studies), while the rates of those detected exclusively on MRI or on postnatal imaging were 0% (95% CI, 0.0-1.7%) (0/357; 11 studies) and 0.9% (95% CI, 0.3-1.8%) (4/660; 17 studies), respectively. Intrauterine death and perinatal death each occurred in 0.7% (95% CI, 0.3-1.4%) (2/824; 23 studies) of cases. In cases without an associated anomaly detected pre- or postnatally, symptomatic infection was found in 1.5% (95% CI, 0.7-2.7%) (6/548; 19 studies) of infants, the overall rate of a neurodevelopmental anomaly was 3.1% (95% CI, 1.6-5.1%) (16/550; 19 studies), and hearing problems affected 6.5% (95% CI, 3.8-10.0%) (36/550; 19 studies) of children. Subanalyses according to the trimester in which maternal infection occurred were affected by the very small number of included cases and lack of comparison of the observed outcomes in the original studies. Compared with fetuses infected in the second or third trimester, those infected in the first trimester had a relatively higher risk of having an additional anomaly detected on follow-up ultrasound or MRI, abnormal neurodevelopmental outcome and hearing problems. CONCLUSIONS: In fetuses with congenital CMV infection in which no anomalies are detected on prenatal ultrasound or MRI, the risk of adverse postnatal outcome is lower than that reported previously in the published literature when not considering the role of antenatal imaging assessment. The results from this review also highlight the potential role of MRI, even in fetuses with no anomalies detected on ultrasound, as an anomaly can be detected exclusively on MRI in about 6% of cases. The findings from this study could enhance prenatal counseling of pregnancies with congenital CMV infection with normal prenatal imaging. © 2020 International Society of Ultrasound in Obstetrics and Gynecology.
Assuntos
Infecções por Citomegalovirus/embriologia , Feto/diagnóstico por imagem , Malformações do Sistema Nervoso/diagnóstico por imagem , Complicações Infecciosas na Gravidez/diagnóstico por imagem , Diagnóstico Pré-Natal/métodos , Adulto , Citomegalovirus , Infecções por Citomegalovirus/congênito , Feminino , Feto/virologia , Humanos , Imageamento por Ressonância Magnética , Malformações do Sistema Nervoso/embriologia , Malformações do Sistema Nervoso/virologia , Gravidez , Complicações Infecciosas na Gravidez/virologia , Resultado da Gravidez , Ultrassonografia Pré-NatalRESUMO
OBJECTIVE: To construct international ultrasound-based standards for fetal cerebellar growth and Sylvian fissure maturation. METHODS: Healthy, well nourished pregnant women, enrolled at < 14 weeks' gestation in the Fetal Growth Longitudinal Study (FGLS) of INTERGROWTH-21st , an international multicenter, population-based project, underwent serial three-dimensional (3D) fetal ultrasound scans every 5 ± 1 weeks until delivery in study sites located in Brazil, India, Italy, Kenya and the UK. In the present analysis, only those fetuses that underwent developmental assessment at 2 years of age were included. We measured the transcerebellar diameter and assessed Sylvian fissure maturation using two-dimensional ultrasound images extracted from available 3D fetal head volumes. The appropriateness of pooling data from the five sites was assessed using variance component analysis and standardized site differences. For each Sylvian fissure maturation score (left or right side), mean gestational age and 95% CI were calculated. Transcerebellar diameter was modeled using fractional polynomial regression, and goodness of fit was assessed. RESULTS: Of those children in the original FGLS cohort who had developmental assessment at 2 years of age, 1130 also had an available 3D ultrasound fetal head volume. The sociodemographic characteristics and pregnancy/perinatal outcomes of the study sample confirmed the health and low-risk status of the population studied. In addition, the fetuses had low morbidity and adequate growth and development at 2 years of age. In total, 3016 and 2359 individual volumes were available for transcerebellar-diameter and Sylvian-fissure analysis, respectively. Variance component analysis and standardized site differences showed that the five study populations were sufficiently similar on the basis of predefined criteria for the data to be pooled to produce international standards. A second-degree fractional polynomial provided the best fit for modeling transcerebellar diameter; we then estimated gestational-age-specific 3rd , 50th and 97th smoothed centiles. Goodness-of-fit analysis comparing empirical centiles with smoothed centile curves showed good agreement. The Sylvian fissure increased in maturation with advancing gestation, with complete overlap of the mean gestational age and 95% CIs between the sexes for each development score. No differences in Sylvian fissure maturation between the right and left hemispheres were observed. CONCLUSION: We present, for the first time, international standards for fetal cerebellar growth and Sylvian fissure maturation throughout pregnancy based on a healthy fetal population that exhibited adequate growth and development at 2 years of age. © 2020 The Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
Assuntos
Cerebelo/embriologia , Aqueduto do Mesencéfalo/embriologia , Desenvolvimento Fetal , Gráficos de Crescimento , Ultrassonografia Pré-Natal , Adulto , Brasil , Cerebelo/crescimento & desenvolvimento , Aqueduto do Mesencéfalo/crescimento & desenvolvimento , Pré-Escolar , Feminino , Idade Gestacional , Humanos , Índia , Lactente , Recém-Nascido , Itália , Quênia , Estudos Longitudinais , Masculino , Gravidez , Resultado da Gravidez , Padrões de Referência , Reino UnidoRESUMO
BACKGROUND: The impact of using the Intergrowth (IG) dating formulae in comparison to the commonly used Robinson dating on the evaluation of biometrics and estimated fetal weight (EFW) has not been evaluated. METHODS: Nationwide cross-sectional study of routine fetal ultrasound biometry in low-risk pregnant women whose gestational age (GA) had been previously assessed by a first trimester CRL measurement. We compared the CRL-based GA according to the Robinson formula and the IG formula. We evaluated the fetal biometric measurements as well as the EFW taken later in pregnancy depending on the dating formula used. Mean and standard deviation of the Z scores as well as the number and percentage of cases classified as <3rd, < 10th, >90th and > 97th percentile were compared. RESULTS: Three thousand five hundred twenty-two low-risk women with scans carried out after 18 weeks were included. There were differences of zero, one and 2 days in 642 (18.2%), 2700 (76.7%) and 180 (5%) when GA was estimated based on the Robinson or the IG formula, respectively. The biometry Z scores assessed later in pregnancy were all statistically significantly lower when the Intergrowth-based dating formula was used (p < 10- 4). Likewise, the number and percentage of foetuses classified as <3rd, < 10th, >90th and > 97th percentile demonstrated significant differences. As an example, the proportion of SGA foetuses varied from 3.46 to 4.57% (p = 0.02) and that of LGA foetuses from 17.86 to 13.4% (p < 10- 4). CONCLUSION: The dating formula used has a quite significant impact on the subsequent evaluation of biometry and EFW. We suggest that the combined and homogeneous use of a recent dating standard, together with prescriptive growth standards established on the same low-risk pregnancies, allows an optimal assessment of fetal growth.
Assuntos
Biometria/métodos , Desenvolvimento Fetal/fisiologia , Peso Fetal/fisiologia , Ultrassonografia Pré-Natal/métodos , Adulto , Peso ao Nascer/fisiologia , Estudos Transversais , Feminino , Humanos , Gravidez , Primeiro Trimestre da GravidezRESUMO
OBJECTIVES: Incompatibility between currently available fetoscopes and the anatomical constraints of the distended fetal bladder, with the resulting curvature around the bladder neck, account for most technical difficulties during fetal cystoscopy in lower urinary tract obstruction (LUTO). The aim of this anatomical study was to assess by magnetic resonance imaging (MRI) the variation in three bladder angles (bladder-neck angle (BNA), vesicourethral angle (VUA) and angle between bladder dome and posterior urethra (DUA)), according to gestational age (GA), bladder volume and the presence of LUTO. METHODS: From our fetal medicine database, we retrieved for review 46 MRI examinations of male fetuses between 2015 and 2019, including 17 with LUTO, examined at a mean GA of 28.1 (range, 17.3-35.0) weeks and 29 age-matched controls, examined at 29.9 (range, 21.9-35.0) weeks. We measured bladder volume, bladder-wall thickness and the three bladder angles, and used the Mann-Whitney U-test to compare values between groups. Variations according to GA and bladder volume were determined using analysis of variance (ANOVA). A reliability study was performed using the Bland-Altman method and Lin's correlation coefficient was calculated. RESULTS: Both bladder volume and bladder-wall thickness were significantly greater in the LUTO group (P < 0.01). BNA was significantly larger in LUTO compared with control fetuses: the mean (range) was 127.1° (101.6-161.6°) vs 111.2° (88.5-157.3°) (P < 0.01). DUA averaged 117° and showed no difference between the groups (P = 0.92). No statistical comparison was performed on VUA since this was not measurable in most control fetuses. ANOVA showed no variation of any angle with bladder volume in both LUTO fetuses and control fetuses. BNA in LUTO fetuses was the only angle to vary with GA, being larger after, compared with at or before, 25 weeks (P = 0.04). The reliability study showed an acceptable bias for both intra- and interobserver reproducibility for all three angles. CONCLUSION: The findings that BNA is increased by approximately 15° in fetuses with LUTO and DUA averages 117° could aid in development of a customized fetal cystoscope and help to overcome the current technical challenges of fetal cystoscopy. Copyright © 2019 ISUOG. Published by John Wiley & Sons Ltd.
Assuntos
Diagnóstico Pré-Natal , Obstrução do Colo da Bexiga Urinária/diagnóstico por imagem , Adulto , Biometria , Estudos de Casos e Controles , Cistoscopia/métodos , Feminino , Idade Gestacional , Humanos , Imageamento por Ressonância Magnética , Masculino , Gravidez , Estudos Retrospectivos , Ultrassonografia Pré-Natal , Obstrução do Colo da Bexiga Urinária/congênitoRESUMO
OBJECTIVE: To create prescriptive growth standards for five fetal brain structures, measured using ultrasound, in healthy, well-nourished women at low risk of impaired fetal growth and poor perinatal outcome, taking part in the Fetal Growth Longitudinal Study (FGLS) of the INTERGROWTH-21st Project. METHODS: This was a complementary analysis of a large, population-based, multicenter, longitudinal study. The sample analyzed was selected randomly from the overall FGLS population, ensuring an equal distribution among the eight diverse participating sites and of three-dimensional (3D) ultrasound volumes across pregnancy (range: 15-36 weeks' gestation). We measured, in planes reconstructed from 3D ultrasound volumes of the fetal head at different timepoints in pregnancy, the size of the parieto-occipital fissure (POF), Sylvian fissure (SF), anterior horn of the lateral ventricle, atrium of the posterior horn of the lateral ventricle (PV) and cisterna magna (CM). Fractional polynomials were used to construct the standards. Growth and development of the infants were assessed at 1 and 2 years of age to confirm their adequacy for constructing international standards. RESULTS: From the entire FGLS cohort of 4321 women, 451 (10.4%) were selected at random. After exclusions, 3D ultrasound volumes from 442 fetuses born without a congenital malformation were used to create the charts. The fetal brain structures of interest were identified in 90% of cases. All structures, except the PV, showed increasing size with gestational age, and the size of the POF, SF, PV and CM showed increasing variability. The 3rd , 5th , 50th , 95th and 97th smoothed centiles are presented. The 5th centiles for the POF and SF were 3.1 mm and 4.7 mm at 22 weeks' gestation and 4.6 mm and 9.9 mm at 32 weeks, respectively. The 95th centiles for the PV and CM were 8.5 mm and 7.5 mm at 22 weeks and 8.6 mm and 9.5 mm at 32 weeks, respectively. CONCLUSIONS: We have produced prescriptive size standards for fetal brain structures based on prospectively enrolled pregnancies at low risk of abnormal outcome. We recommend these as international standards for the assessment of measurements obtained using ultrasound from fetal brain structures. © 2020 Authors. Ultrasound in Obstetrics & Gynecology published by John Wiley & Sons Ltd on behalf of International Society of Ultrasound in Obstetrics and Gynecology.
Assuntos
Encéfalo/diagnóstico por imagem , Ultrassonografia Pré-Natal , Adulto , Encéfalo/crescimento & desenvolvimento , Cefalometria , Feminino , Desenvolvimento Fetal , Idade Gestacional , Saúde Global , Humanos , Estudos Longitudinais , Gravidez , Valores de ReferênciaRESUMO
OBJECTIVE: To investigate the obstetric outcome of women carriers of the oxidative phosphorylation (OXPHOS) disorder mutation. DESIGN: A retrospective cohort study in a single tertiary centre. SETTING: A review of the obstetric history of women referred for prenatal screening of a mitochondrial disorder was performed. POPULATION: Women were divided into three groups: (1) women carrying mitochondrial DNA (mtDNA) mutations; (2) healthy women with a family history of mtDNA-related OXPHOS disorder; and (3) healthy women carrying heterozygote nuclear DNA mutations. METHODS: Obstetric history and pregnancy complications were evaluated separately in the three groups and compared with the control group. MAIN OUTCOME MEASURES PREGNANCY COMPLICATIONS. RESULTS: Seventy-five women were included with 287 cumulative pregnancies. Groups 1 and 3 had a significantly greater proportion of terminations of pregnancy (20 and 13% versus 0.8%, P < 0.001), and a lower percentage of live births (52 and 72% versus 87%, P = 0.001), compared with controls. Apart from this, the rate of obstetric complications in group 3 did not differ from the controls. The obstetric history of women in group 1 was marked by higher rates of early miscarriages (26 versus 11%, P = 0.004), gestational diabetes (14 versus 3%, P = 0.02), intrauterine growth restriction (IUGR, 10 versus 1%, P = 0.008), and postpartum haemorrhage than were reported for controls (12 versus 2%, P = 0.01). CONCLUSION: Women who are heteroplasmic for OXPHOS mutations have a higher incidence of pregnancy losses, gestational diabetes, IUGR, and post postpartum haemorrhage. TWEETABLE ABSTRACT: Women heteroplasmic for mitochondrial DNA mutations have a higher incidence of obstetric complications, compared with the control group.